Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Surface albedo and reflectance: Review of definitions, angular and spectral effects, and intercomparison of major data sources in support of advanced solar irradiance modeling over the Americas

This study defines albedo and reflectance in the context of solar applications. It examines the main sources of surface albedo data that can be used to help solar irradiance modeling efforts, such as undertaken by the National Renewable Energy Laboratory (NREL) over the Americas, for instance, per the National Solar Radiation Database (NSRDB). The MODIS-based albedo database, as used as input to derive historical time series of solar irradiance in the current version of the NSRDB, is compared to other sources of global gridded data over the Americas in general and some specific areas in particular. The particular role of snow cover is analyzed. It is found that, in the current MODIS-based NSRDB implementation, snow-impacted areas have been assigned a too high albedo in general because of the lack of consideration for the antagonistic effect of surface roughness, among other factors. Other albedo databases, such as CMSAF, MINES-ParisTech or the ERA5 reanalysis, do not display such high albedos at latitudes above ~40 degrees N. The gap-free and snow-free MODIS MCD43GF product is found affected by a long-term downward trend over some areas and out-of-phase seasonal effects over other areas, in comparison with MERRA-2 reanalysis data in particular. Comparisons with actual albedo measurements at the arid Desert Rock site in Nevada also show that albedo data derived from land surface models are affected by systematic bias. Five albedo databases are intercompared for the area around Ivanpah Playa, California, which has great importance in both remote sensing and solar applications. Various aspects of the proper usage of albedo data in solar radiation modeling are discussed, regarding calculations of both the backscattering process and reflections on a tilted surface: spatial resolution, temporal resolution, angular effects, and spectral effects. An important distinction is made between the use of albedo data at ~4 km resolution for backscattering calculations and at ~10 m resolution for transposition calculations to tilted planes, which might additionally require spectral information for monofacial or bifacial PV applications. It is shown that the tilted calculations usually performed in solar resource assessments are far from realistic in the case of most large-scale PV applications, for which a more suitable methodological approach is described. For such needs, the limitations of the current sources of high-resolution reflectance data are discussed. The impact of surface albedo estimation errors on the estimation of backscattered irradiance over snowy areas is evaluated. It is found non-negligible, and even large under cloudy conditions.

14 SOLAR ENERGY↗

Inspection of commercial optical devices for data storage using a three Gaussian beam microscope interferometer

Recently, an interferometric profilometer based on the heterodyning of three Gaussian beams has been reported. This microscope interferometer, called a three Gaussian beam interferometer, has been used to profile high quality optical surfaces that exhibit constant reflectivity with high vertical resolution and lateral resolution near {lambda}. We report the use of this interferometer to measure the profiles of two commercially available optical surfaces for data storage, namely, the compact disk (CD-R) and the digital versatile disk (DVD-R). We include experimental results from a one-dimensional radial scan of these devices without data marks. The measurements are taken by placing the devices with the polycarbonate surface facing the probe beam of the interferometer. This microscope interferometer is unique when compared with other optical measuring instruments because it uses narrowband detection, filters out undesirable noisy signals, and because the amplitude of the output voltage signal is basically proportional to the local vertical height of the surface under test, thus detecting with high sensitivity. We show that the resulting profiles, measured with this interferometer across the polycarbonate layer, provide valuable information about the track profiles, making this interferometer a suitable tool for quality control of surface storage devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Soft X-ray flat-field VLS spectrographs

We have analysed the capabilities of flat-field spectrometers with concave VLS reflection gratings from the standpoint of spectral imaging in the soft X-ray range. Two types of such instruments are shown to exist: spectrographs with as flat as possible a portion of the focal surface (of Harada spectrograph type) and those with a nearly constant distance from the grating centre to the focal surface, which permits reaching a high spatial resolution with the use of a crossed focusing mirror (without a loss in spectral resolution). Three 0.25, 0.5, and 1.5-m long spectrographs of Harada type were calculated for operation in the ranges 90 – 250, 50 – 200, and 20−110 A-ring , respectively. We show that each of the calculated instruments may be converted to an instrument of the second type for operation in the second and fourth diffraction orders without significant changes in scheme geometry. In this case, the theoretical spatial resolution is equal to ∼10 μm throughout the optimisation range. (x-ray optics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of soft x-ray time-resolved photoemission spectroscopy system with a two-dimensional angle-resolved time-of-flight analyzer at SPring-8 BL07LSU

We have developed a soft x-ray time-resolved photoemission spectroscopy system using synchrotron radiation (SR) at SPring-8 BL07LSU and an ultrashort pulse laser system. Two-dimensional angle-resolved measurements were performed with a time-of-flight-type analyzer. The photoemission spectroscopy system is synchronized to light pulses of SR and laser using a time control unit. The performance of the instrument is demonstrated by mapping the band structure of a Si(111) crystal over the surface Brillouin zones and observing relaxation of the surface photo-voltage effect using the pump (laser) and probe (SR) method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement Quality Objective Considerations for Residual Alpha Surface Radioactivity Measurements at Remediation Sites - 16522

Surveys for residual alpha surface radioactivity on materials, equipment, and other non-porous surfaces are most-commonly performed using the traditional 'best available' equipment. The best available equipment for measuring alpha surface radioactivity includes portable gas-flow proportional or scintillation detectors with active surface areas typically ranging from 50 to 800 square centimeters (cm{sup 2}). The measurement equipment is offered by numerous service providers and instrument vendors applying basic detection principles that date back to the early-Atomic Age. The detector face is held as close to the surface as possible and scanned at a typical rate of 2 to 5 centimeters per second (cm/s). Any audible or visual indication of elevated alpha activity would result in a more careful assessment of the possible 'hot spot'. Modern surface contamination surveys continue to employ these best available technologies while endeavoring to achieve ever more restrictive measurement quality objectives and screening or release criteria. This paper considers the possibly unforeseen consequences to sensitivity and precision as scanning speeds are reduced to meet constraining measurement quality objectives. Sensitivity calculations are conducted to demonstrate how application of real-world efficiencies and the most common survey approaches are inadequate to meet sensitivity objectives based on American National Standard N13.12-2013, Surface and Volume Radioactivity Standards for Clearance screening criteria. Alternate data collection and assessment methodologies are offered to enhance the defensibility of collected data with stakeholders. Limitations of available or applied alpha survey technologies should be considered when establishing survey programs at project sites where alpha-emitting radionuclides are expected to contribute to residual surface radioactivity. These include but are not limited to nuclear fuel-cycle sites, military/weapons/energy research and production facilities, and 19.-20. Century-era commercial/ industrial/research/medical facilities where radioactive materials were handled. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rapid Fabrication of High Frame Rate Multichannel FTIR Spectrometers

Spectrally resolved signals in the short- to mid-wave infrared (SWIR/MWIR) bands at high-temporal resolution are critical for many national security remote sensing missions. Currently available off the shelf technology can achieve either high temporal resolution or high spectral resolution, but rugged instruments that can achieve both simultaneously remain mostly in the realm of one-off R&D projects. This report documents efforts to demonstrate a new technique for designing and building high resolution, high framerate multichannel FTIR (MC-FTIR) spectrometers that operate in the SWIR/MWIR bands. The core optical element in a MC-FTIR spectrometer is an array of statically-tuned lamellar grating interferometers (LGI). In the original MC-FTIR work these arrays were fabricated using a synchrotron x-ray lithography method. We proposed to instead fabricate these LGI arrays using multiphoton lithography (MPL), a 3D printing technique that can fabricate meso-scale structures with sub-micron precision. Although we were able to fabricate LGI arrays of sufficient size using MPL, the realized optical surfaces had unsuitably high optical form errors, precluding their use in a fieldable instrument. Further advancement in MPL technology may eventually enable fabrication of interferometer-grade LGI arrays.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase I (Final Report)

The focus of this proposal was the development of a new instrument capable of in-situ, spatially resolved, measurement of the energy spectra of ions in the edge of a tokamak plasma. The energy spectra of the ions determines the rates of sputtering and erosion of the plasma facing surfaces. The ion spectra in the edge is not easily determined spectroscopically and must be measured in situ since the ions are confined by the strong magnetic fields of the tokamak. Conventional energy analyzers are too large and expensive to install in multiple locations around the tokamak torus. The probes to be developed in this project are compact, low cost, and small enough to be placed inside of specially prepared wall tiles – essentially creating a “smart” plasma facing surface in a tokamak. Phase 1 of this project successfully demonstrated that two key elements of the instrument, the collimator and the energy analyzer, could be fabricated on a single silicon wafer and the combination functioned as designed when tested with an electron beam.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Eddy Correlation Flux Measurement System (ECOR) Instrument Handbook

The eddy correlation (ECOR) flux measurement system provides in situ, half-hour measurements of surface turbulent fluxes of momentum, sensible heat, latent heat, and carbon dioxide (CO 2 ) at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) User Facility sites. ARM’s ECORs also historically measured methane fluxes at Utqiaġvik and Oliktok Point, Alaska. The fluxes are obtained with the eddy covariance technique, which involves correlation of the vertical wind component with the horizontal wind component, the air temperature, the water vapor density, and the CO 2 concentration.

54 ENVIRONMENTAL SCIENCES↗

A high sensitivity momentum flux measuring instrument for plasma thruster exhausts and diffusive plasmas

A high sensitivity momentum flux measuring instrument based on a compound pendulum has been developed for use with electric propulsion devices and radio frequency driven plasmas. A laser displacement system, which builds upon techniques used by the materials science community for surface stress measurements, is used to measure with high sensitivity the displacement of a target plate placed in a plasma thruster exhaust. The instrument has been installed inside a vacuum chamber and calibrated via two different methods and is able to measure forces in the range of 0.02-0.5 mN with a resolution of 15 {mu}N. Measurements have been made of the force produced from the cold gas flow and with a discharge ignited using argon propellant. The plasma is generated using a Helicon Double Layer Thruster prototype. The instrument target is placed about 1 mean free path for ion-neutral charge exchange collisions downstream of the thruster exit. At this position, the plasma consists of a low density ion beam (10%) and a much larger downstream component (90%). The results are in good agreement with those determined from the plasma parameters measured with diagnostic probes. Measurements at various flow rates show that variations in ion beam velocity and plasma density and the resulting momentum flux can be measured with this instrument. The instrument target is a simple, low cost device, and since the laser displacement system used is located outside the vacuum chamber, the measurement technique is free from radio frequency interference and thermal effects. It could be used to measure the thrust in the exhaust of other electric propulsion devices and the momentum flux of ion beams formed by expanding plasmas or fusion experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BerkSEL: A scale-invariant laser beyond the Schawlow-Townes two-mirror strategy

I argue that a surface emitting laser that remains single mode irrespective of its size, a scale-invariant laser, should of necessity also waste light at the edge. This is a fundamental departure from the Schawlow-Townes two-mirror strategy that keeps light away from mirrors and edges to preserve gain and minimize loss. The strategy was implemented in the recent discovery of the Berkeley Surface Emitting Laser (BerkSEL).

47 OTHER INSTRUMENTATION↗

Status of IceCube and Future Plans

The IceCube detector, located near the geographic South Pole, is now the largest neutrino telescope in the world, with sensitivity in the TeV--PeV range. When complete, IceCube will consist of at least 70 in-ice strings and 140 surface tanks, and IceCube's predecessor, the AMANDA detector. Radio and acoustic instrumentation is also being deployed in the IceCube footprint to search for neutrinos in the PeV-EeV energy range. I will review the status and latest results from IceCube and physics prospects for the complete detector and radio/acoustic extensions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extra Dimensions: 3D in PDF Documentation

Experimental science is replete with multi-dimensional information which is often poorly represented by the two dimensions of presentation slides and print media. Past efforts to disseminate such information to a wider audience have failed for a number of reasons, including a lack of standards which are easy to implement and have broad support. Adobe's Portable Document Format (PDF) has in recent years become the de facto standard for secure, dependable electronic information exchange. It has done so by creating an open format, providing support for multiple platforms and being reliable and extensible. By providing support for the ECMA standard Universal 3D (U3D) and the ISO PRC file format in its free Adobe Reader software, Adobe has made it easy to distribute and interact with 3D content. Until recently, Adobe's Acrobat software was also capable of incorporating 3D content into PDF files from a variety of 3D file formats, including proprietary CAD formats. Furthermore, this functionality is no longer available in Acrobat X, having been spun off to a separate company. Incorporating 3D content now requires the additional purchase of a separate plug-in. In this talk we present alternatives based on open source libraries which allow the programmatic creation of 3D content in PDF format. While not providing the same level of access to CAD files as the commercial software, it does provide physicists with an alternative path to incorporate 3D content into PDF files from such disparate applications as detector geometries from Geant4, 3D data sets, mathematical surfaces or tesselated volumes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gravitational wave signatures of the absence of an event horizon. II. Extreme mass ratio inspirals in the spacetime of a thin-shell gravastar

We study gravitational wave emission from the quasicircular, extreme mass ratio inspiral of compact objects of mass m{sub 0} into massive objects of mass M>>m{sub 0} whose external metric is identical to the Schwarzschild metric, except for the absence of an event horizon. To be specific we consider one of the simplest realizations of such an object: a nonrotating thin-shell gravastar. The power radiated in gravitational waves during the inspiral shows distinctive peaks corresponding to the excitation of the polar oscillation modes of the gravastar. For ultracompact gravastars the frequency of these peaks depends mildly on the gravastar compactness. For masses M{approx}10{sup 6}M{sub {center_dot}}the peaks typically lie within the optimal sensitivity bandwidth of the Laser Interferometer Space Antenna, potentially providing a unique signature of the horizonless nature of the central object. For relatively modest values of the gravastar compactness the radiated power has even more peculiar features, carrying the signature of the microscopic properties of the physical surface replacing the event horizon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microstrain and Grain-Size Analysis From Diffraction Peak Width and Graphical Derivation of High-Pressure Thermomechanics

An analytical method is presented for deriving the thermomechanical properties of polycrystalline materials under high-pressure (P) and high-temperature (T) conditions. This method deals with non-uniform stress among heterogeneous crystal grains and surface strain in nanocrystalline materials by examining peak-width variation under different P-T conditions. Because the method deals directly with lattice d spacing and local deformation caused by stress, it can be applied to process any diffraction profile, independent of detection mode. In addition, a correction routine is developed using diffraction elastic ratios to deal with severe surface strain and/or strain anisotropy effects related to nano-scale grain sizes, so that significant data scatter can be reduced in a physically meaningful way. Graphical illustration of the resultant microstrain analysis can identify micro/local yields at the grain-to-grain interactions resulting from high stress concentration, and macro/bulk yield of the plastic deformation over the entire sample. This simple and straightforward approach is capable of revealing the corresponding micro and/or macro yield stresses, grain crushing or growth, work hardening or softening, and thermal relaxation under high-P-T conditions, as well as the intrinsic residual strain and/or surface strain in the polycrystalline bulk. In addition, this approach allows the instrumental contribution to be illustrated and subtracted in a straightforward manner, thus avoiding the potential complexities and errors resulting from instrument correction. Applications of the method are demonstrated by studies of [alpha]-SiC (6H, moissanite) and of micro- and nanocrystalline nickel by synchrotron X-ray and time-of-flight neutron diffraction.

43 PARTICLE ACCELERATORS↗

Enabling Re-executable Workflows with Near-realtime Visualization, Provenance Capture and Advanced Querying for Mass Spectrometry Data

Mass spectrometry imaging (MSI) enables simultaneous spatially-resolved analysis of numerous ionizable molecules on a sample surface. The current analysis pipeline involves analyzing the data coming off the instrument using a tool called MSI Quickview and saving the results onto a storage drive before moving on to the next experiment. While this works well for single datasets, there is a demand for more scalable, flexible workflows that are re-executable across datasets, support extensive querying and ease collaboration. Here, we present a workflow that moves data analysis from a mere desktop application for single experiments to a more general capability

Re-executable workflow↗

Coastal Sea Level Observations Record the Twentieth-Century Enhancement of Decadal Climate Variability

Changes in the amplitude of decadal climate variability over the twentieth century have been noted, with most evidence derived from tropical Pacific sea surface temperature records. However, the length, spatial coverage, and stability of most instrumental records are insufficient to robustly identify such nonstationarity, or resolve its global spatial structure. Here, it is found that the long-term, stable, observing platform provided by tide gauges reveals a dramatic increase in the amplitude and spatial coherence of decadal (11–14-yr period) coastal sea level (ζ) variability between 1960 and 2000. During this epoch, western North American ζ was approximately out of phase with ζ in Sydney, Australia, and led northeastern U.S. ζ by approximately 1–2 years. The amplitude and timing of changes in decadal ζ variability in these regions are consistent with changes in atmospheric variability. Specifically, central equatorial Pacific wind stress and Labrador Sea heat flux are highly coherent and exhibit contemporaneous, order-of-magnitude increases in decadal power. These statistical relationships have a mechanistic underpinning: Along the western North American coastline, equatorial winds are known to drive rapidly propagating ζ signals along equatorial and coastal waveguides, while a 1–2-yr lag between Labrador Sea heat fluxes and northeastern United States ζ is consistent with a remotely forced, buoyancy-driven, mechanism. Tide gauges thus provide strong independent support for an increase in interbasin coherence on decadal time scales over the second half of the twentieth century, with implications for both the interpretation and prediction of climate and sea level variability.

54 ENVIRONMENTAL SCIENCES↗

Temperature Inversions below 1 km from a V-Band Scanning Radiometer at the North Slope of Alaska

A single-channel (56.7 GHz) scanning radiometer was deployed in August 2022 at the Atmospheric Radiation Measurement (ARM) North Slope of Alaska site near Utqiaġvik. The radiometer is designed to provide temperature profiles between 0 and 1 km every 5 min. Averaging kernels show that this single-channel radiometer, taking observations at 10 discrete elevation angles, yields approximately the same information as a seven-channel V-band radiometer scanning three elevation angles. The instrument is able to reproduce the occurrence of temperature inversions between the surface and 1 km and their strength showing a correlation of 0.85, bias of −0.6 K, and slope of 1.04 with respect to radiosondes. Uncertainty in the inversion base height varies from 50 m near the surface to ∼300 m above 0.4 km when compared with radiosondes. Conversely, the inversion top height is overestimated and has higher uncertainty due to the degrading effects of the averaging kernels on the vertical resolution of the retrievals. Thanks to the high temporal resolution of the retrievals, the diurnal cycle of boundary layer temperature was evaluated showing that the radiometer can capture some aspects of the boundary layer thermal structure. The present analysis provides an overview of the capabilities of this simple observing configuration for selected applications.

Atmospheric profilers↗

Semiconductor detectors with proximity signal readout

Semiconductor-based radiation detectors are routinely used for the detection, imaging, and spectroscopy of x-rays, gamma rays, and charged particles for applications in the areas of nuclear and medical physics, astrophysics, environmental remediation, nuclear nonproliferation, and homeland security. Detectors used for imaging and particle tracking are more complex in that they typically must also measure the location of the radiation interaction in addition to the deposited energy. In such detectors, the position measurement is often achieved by dividing or segmenting the electrodes into many strips or pixels and then reading out the signals from all of the electrode segments. Fine electrode segmentation is problematic for many of the standard semiconductor detector technologies. Clearly there is a need for a semiconductor-based radiation detector technology that can achieve fine position resolution while maintaining the excellent energy resolution intrinsic to semiconductor detectors, can be fabricated through simple processes, does not require complex electrical interconnections to the detector, and can reduce the number of required channels of readout electronics. Proximity electrode signal readout (PESR), in which the electrodes are not in physical contact with the detector surface, satisfies this need.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗