Search NASA⌕ Search

SEARCH · Search NASA

Results for “test protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Mission perspectives

Handling the Martian samples by requiring that they be subjected to a complex protocol designed to detect life, which, if present, will then be assessed for its effects on terrestrial life forms is addressed. Sample testing must be performed within facilities that ensure that such Martian organisms cannot be accidentally introduced to Earth's biosphere during the assessment process. An Orbiting Quarantine Facility (OQF) designed to permit the detection and characterization of Martian life forms, while affording the Earth and its inhabitants the maximum level of protection, is analyzed and described.

Source record↗

Achieving dependability throughout the development process - A distributed software experiment

Distributed software engineering techniques and methods for improving the specification and testing phases are considered. With multiversion development, multiple implementations allow the use of an automated approach to testing called back-to-back (B/B) testing in which the outputs are compared to detect any discrepancies. However, a specification defect may lead to similar errors in the multiple versions and the underlying fault may not be detected with a B/B testing approach. The use of diverse formal specifications has been proposed as a solution to this problem, since defects in independently written specifications are likely to be different. To examine these issues, an experiment was performed using the design diversity approach in the specification, design, implementation, and testing of distributed software. In the experiment, three diverse formal specifications were used to produce multiple independent implementations of a distributed communication protocol in Ada. The problems encountered in building complex concurrent processing systems in Ada were also studied. Many pitfalls were discovered in mapping the formal specifications into Ada implementations.

Kelly, John P. J.↗

Design optimization of a brush turbine with a cleaner/water based solution

Recently, a fluid turbine which has a brush attached to it has been designed and tested with water as fluid. The purpose of the turbine-brush is to clean up fouling in a tube. The Montreal Protocol prohibits the use of CFC products from refrigeration industry or from industry in general as a cleanser in 1996. Alternatives for the cleansers, devices or a combination of alternative devices with a cleanser should be found. One of the methods is to develop a device which cleans fouling with a cleaning medium. In this paper, we describe a turbine connected with a brush. However, the turbine with the brush should be simple and easy to install. This device is a combined small liquid turbine with a brush. The turbine is activated by the liquid flowing through the tube. Then the turbine turns the brush cleaning fouling along the tube. Based on the energy conservation and the Bernoulli equation along with an empirical relationship of drag force obtained from an experimental apparatus, a relationship of the rotational speed, the number of blades, and geometric variables of the turbine-brush was obtained. The predicted rotational speeds were compared with the experimental observations. Further work was recommended for improvements.

Kim, Rhyn H.↗

Proceedings of the Second NASA Formal Methods Symposium

This publication contains the proceedings of the Second NASA Formal Methods Symposium sponsored by the National Aeronautics and Space Administration and held in Washington D.C. April 13-15, 2010. Topics covered include: Decision Engines for Software Analysis using Satisfiability Modulo Theories Solvers; Verification and Validation of Flight-Critical Systems; Formal Methods at Intel -- An Overview; Automatic Review of Abstract State Machines by Meta Property Verification; Hardware-independent Proofs of Numerical Programs; Slice-based Formal Specification Measures -- Mapping Coupling and Cohesion Measures to Formal Z; How Formal Methods Impels Discovery: A Short History of an Air Traffic Management Project; A Machine-Checked Proof of A State-Space Construction Algorithm; Automated Assume-Guarantee Reasoning for Omega-Regular Systems and Specifications; Modeling Regular Replacement for String Constraint Solving; Using Integer Clocks to Verify the Timing-Sync Sensor Network Protocol; Can Regulatory Bodies Expect Efficient Help from Formal Methods?; Synthesis of Greedy Algorithms Using Dominance Relations; A New Method for Incremental Testing of Finite State Machines; Verification of Faulty Message Passing Systems with Continuous State Space in PVS; Phase Two Feasibility Study for Software Safety Requirements Analysis Using Model Checking; A Prototype Embedding of Bluespec System Verilog in the PVS Theorem Prover; SimCheck: An Expressive Type System for Simulink; Coverage Metrics for Requirements-Based Testing: Evaluation of Effectiveness; Software Model Checking of ARINC-653 Flight Code with MCP; Evaluation of a Guideline by Formal Modelling of Cruise Control System in Event-B; Formal Verification of Large Software Systems; Symbolic Computation of Strongly Connected Components Using Saturation; Towards the Formal Verification of a Distributed Real-Time Automotive System; Slicing AADL Specifications for Model Checking; Model Checking with Edge-valued Decision Diagrams; and Data-flow based Model Analysis.

Munoz, Cesar↗

Performance Characterization and Simulation of Amine-Based Vacuum Swing Adsorption Units for Spacesuit Carbon Dioxide and Humidity Control

Controlling carbon dioxide (CO2) and water (H2O) concentrations in the vapor phase of a space suit is critical to ensuring an astronauts safety, comfortability, and capability to perform extra-vehicular activity (EVA) tasks. Historically, this has been accomplished using lithium hydroxide (LiOH) and metal oxides (MetOx). Lithium hydroxide is a consumable material and requires priming with water before it becomes effective at removing carbon dioxide. MetOx is regenerable through a power-intensive thermal cycle but is significantly heavier on a volume basis than LiOH. As an alternative, amine-based vacuum swing beds are under aggressive development for EVA applications which control atmospheric concentrations of both CO2 and H2O through a fully-regenerative process. The current concept, referred to as the rapid cycle amine (RCA), has resulted in numerous laboratory prototypes. Performance of these prototypes have been assessed and documented from experimental and theoretical perspectives. To support developmental efforts, a first principles model has also been established for the vacuum swing adsorption technology. The efforts documented herein summarize performance characterization and simulation results for several variable metabolic profiles subjected to the RCA. Furthermore, a variety of control methods are explored including timed swing cycles, instantaneous CO2 feedback control, and time-averaged CO2 feedback control. A variety of off-nominal tests are also explored including high/low suit temperatures, increasingly high humidity cases, and dynamic pressure cases simulating the suit pre-breathe protocol. Consequently, this work builds on efforts previous efforts to fully bound the performance of the rapid cycle amine under a variety of nominal and off-nominal conditions.

Swickrath, Michael J.↗

The Use of Dynamic Visual Acuity as a Functional Test of Gaze Stabilization Following Space Flight

After prolonged exposure to a given gravitational environment the transition to another is accompanied by adaptations in the sensorimotor subsystems, including the vestibular system. Variation in the adaptation time course of these subsystems, and the functional redundancies that exist between them make it difficult to accurately assess the functional capacity and physical limitations of astro/cosmonauts using tests on individual subsystems. While isolated tests of subsystem performance may be the only means to address where interventions are required, direct measures of performance may be more suitable for assessing the operational consequences of incomplete adaptation to changes in the gravitational environment. A test of dynamic visual acuity (DVA) is currently being used in the JSC Neurosciences Laboratory as part of a series of measures to assess the efficacy of a countermeasure to mitigate postflight locomotor dysfunction. In the current protocol, subjects visual acuity is determined using Landolt ring optotypes presented sequentially on a computer display. Visual acuity assessments are made both while standing and while walking at 1.8 m/s on a motorized treadmill. The use of a psychophysical threshold detection algorithm reduces the required number of optotype presentations and the results can be presented immediately after the test. The difference between the walking and standing acuity measures provides a metric of the change in the subject s ability to maintain gaze fixation on the visual target while walking. This functional consequence is observable regardless of the underlying subsystem most responsible for the change. Data from 15 cosmo/astronauts have been collected following long-duration (approx. 6 months) stays in space using a visual target viewing distance of 4.0 meters. An investigation of the group mean shows a change in DVA soon after the flight that asymptotes back to baseline approximately one week following their return to earth. The performance of some subjects nicely parallels the stereotypical recovery curve observed in the group mean data. Others show dramatic changes in DVA from one test day to another. These changes may be indicative of a re-adaptation process that is not characterized by a steady improvement with the passage of time, but is instead a dynamic search for appropriate coordinative strategy to achieve the desired gaze stabilization goal. Ground-based data have been collected in our lab using DVA with one of the goals being to improve the DVA test itself. In one of these studies, the DVA test was repeated using a visual target viewing distance of 0.5 meters. While walking, the relative contributions of the otoliths and semi-circular canals that are required to stabilize gaze are affected by visual target viewing distance. It may be possible to exploit this using the current treadmill DVA test to differentially assess changes in these vestibular subsystems. The postflight DVA evaluations currently used have been augmented to include the near target version of the test. Preliminary results from these assessments, as well as the results from the ground-based tests will also be reported. DVA provides a direct measure of a subject's ability to see clearly in the presence of self-motion. The use of the current tests for providing a functionally relevant metric is evident. However, it is possible to expand the scope of DVA testing to include scenarios other than walking. A facility for measuring DVA in the presence of passive movements is being created. Using a mechanized platform to provide the perturbation, it should be possible to simulate aircraft and automobile vibration profiles. Used in conjunction with the far and near visual displays this facility should be able to assess a subject s ability to clearly see distant objects as well as those that appear on the dashboard or instrument control panel during functionally relevant situations.

Peters, B. T.↗

A Remote, Human-in-the-Loop Evaluation of a Multiple-Drone Delivery Operation

Over time, advances in unmanned aircraft systems (UAS) have enabled a shift in the operational paradigm from one operator managing one aircraft to that of multiple operators working together to manage multiple aircraft. This shift has highlighted the need for effective human-autonomy teaming methods to maintain manageable workload levels for operators as well as high standards of system performance and safety. This paper presents a study aimed at evaluating whether automation can help operators manage workload during small UAS (sUAS) package delivery scenarios featuring contingency situations. These contingency situations, resulting from unplanned UAS Volume Reservations (UVRs), required flight path reroutes for multiple aircraft simultaneously. The study manipulated the number of aircraft affected by the UVRs and the level of automation support. The presence of terrain conflicts was also controlled within each scenario. Due to the COVID-19 pandemic, subjects were not able to gain direct access to the Ground Control System (GCS). Therefore, the study was conducted using a subject-surrogate paradigm that required subjects to relay commands through a verbal protocol from remote locations outside of the lab to a researcher surrogate who had direct control of the GCS interfaces at the lab location. Results show that the automated support condition was associated with faster reroute response times, more efficient reroute maneuvers, and significantly lower levels of perceived workload than the manual reroute condition. However, the automation support level did not significantly impact pilots’ ability to avoid the UVR successfully; pilots were overwhelmingly capable of avoiding the UVR in all conditions. The presence of terrain conflicts primarily impacted pilot performance by leading to multiple uploads per vehicle, which was not typically required when pilots only needed to maneuver laterally. Although subjects did not have direct control over the GCS, subjective ratings indicate that the displays under test provided them with sufficient information to manage their aircraft and promptly respond to the unplanned UVRs. Overall, the objective and subjective data strongly suggest that the verbal protocol and subject-surrogate paradigm were effective methods for collecting data remotely amid the COVID-19 pandemic.

multi-UAS↗

Can Cell to Cell Thermal Runaway Propagation be Prevented in a Li-ion Battery Module?

Increasing cell spacing decreased adjacent cell damage center dotElectrically connected adjacent cells drained more than physically adjacent cells center dotRadiant barrier prevents propagation when fully installed between BP cells center dotBP cells vent rapidly and expel contents at 100% SOC -Slower vent with flame/smoke at 50% -Thermal runaway event typically occurs at 160 degC center dotLG cells vent but do not expel contents -Thermal runaway event typically occurs at 200 degC center dotSKC LFP modules did not propagate; fuses on negative terminal of cell may provide a benefit in reducing cell to cell damage propagation. New requirement in NASA-Battery Safety Requirements document: JSC 20793 Rev C 5.1.5.1 Requirements - Thermal Runaway Propagation a. For battery designs greater than a 80-Wh energy employing high specific energy cells (greater than 80 watt-hours/kg, for example, lithium-ion chemistries) with catastrophic failure modes, the battery shall be evaluated to ascertain the severity of a worst-case single-cell thermal runaway event and the propensity of the design to demonstrate cell-to-cell propagation in the intended application and environment. NASA has traditionally addressed the threat of thermal runaway incidents in its battery deployments through comprehensive prevention protocols. This prevention-centered approach has included extensive screening for manufacturing defects, as well as robust battery management controls that prevent abuse-induced runaway even in the face of multiple system failures. This focused strategy has made the likelihood of occurrence of such an event highly improbable. b. The evaluation shall include all necessary analysis and test to quantify the severity (consequence) of the event in the intended application and environment as well as to identify design modifications to the battery or the system that could appreciably reduce that severity. In addition to prevention protocols, programs developing battery designs with catastrophic failure modes should take the steps necessary to assess the severity of a possible thermal runaway event. Programs should assess whether there are reasonable design changes that could appreciably affect the severity of the outcome. Evaluation should include environmental effects to surrounding hardware (i.e., temperature, pressure, shock), contamination effects due to any expelled contaminates, and venting propulsive effects when venting overboard.

Jeevarajan, Judith↗

Intrapericardial denervation - Radial artery blood flow and heart rate responses to LBNP

The effects of intrapericardial denervation on the radial artery blood flow velocity (RABFV) and heart rate (HR) responses to LBNP in rhesus monkeys were investigated by measuring the RABFV transcutaneously by a continuous-wave Doppler ultrasonic flowmeter in order to derive an index of forearm blood flow response to low (0 to -20 mm Hg) and high (0 to -60 mm Hg) ramp exposures during supine LBNP. Four of the eight subjects were subjected to efferent and afferent cardiac denervation. It was found that, during low levels of LBNP, monkeys with cardiac denervation exhibited no cardiopulmonary baroreceptor-mediated change in the RABFV or HR, unlike the intact animals, which showed steady decreases in RABFV during both high- and low-pressure protocols. It is suggested that forearm blood flow and HR responses to low-level LBNP, along with pharmacological challenge, are viable physiological tests for verifying the completeness of atrial and cardiopulmonary baroreceptor denervation.

Mckeever, Kenneth H.↗

Exercise performance, core temperature, and metabolism after prolonged restricted activity and retraining in dogs

Physiological effects of restricted activity (RA) and subsequent retraining have been studied. Ten male mongrel dogs performed a submaximal exercise endurance test on a treadmill during kennel control, after 8 weeks of cage confinement and after eight weeks of retraining using the same treadmill protocol 1 h/d for 6 d/week. Data obtained show that RA reduces exercise endurance, the effectiveness of exercise thermoregulation, muscle glycogen stores, and the lipolytic response to exercise and to noradrenaline stimulation.

Nazar, K.↗

NASA Tech Briefs, January 2004

Topics covered include: Multisensor Instrument for Real-Time Biological Monitoring; Sensor for Monitoring Nanodevice-Fabrication Plasmas; Backed Bending Actuator; Compact Optoelectronic Compass; Micro Sun Sensor for Spacecraft; Passive IFF: Autonomous Nonintrusive Rapid Identification of Friendly Assets; Finned-Ladder Slow-Wave Circuit for a TWT; Directional Radio-Frequency Identification Tag Reader; Integrated Solar-Energy-Harvesting and -Storage Device; Event-Driven Random-Access-Windowing CCD Imaging System; Stroboscope Controller for Imaging Helicopter Rotors; Software for Checking State-charts; Program Predicts Broadband Noise from a Turbofan Engine; Protocol for a Delay-Tolerant Data-Communication Network; Software Implements a Space-Mission File-Transfer Protocol; Making Carbon-Nanotube Arrays Using Block Copolymers: Part 2; Modular Rake of Pitot Probes; Preloading To Accelerate Slow-Crack-Growth Testing; Miniature Blimps for Surveillance and Collection of Samples; Hybrid Automotive Engine Using Ethanol-Burning Miller Cycle; Fabricating Blazed Diffraction Gratings by X-Ray Lithography; Freeze-Tolerant Condensers; The StarLight Space Interferometer; Champagne Heat Pump; Controllable Sonar Lenses and Prisms Based on ERFs; Measuring Gravitation Using Polarization Spectroscopy; Serial-Turbo-Trellis-Coded Modulation with Rate-1 Inner Code; Enhanced Software for Scheduling Space-Shuttle Processing; Bayesian-Augmented Identification of Stars in a Narrow View; Spacecraft Orbits for Earth/Mars-Lander Radio Relay; and Self-Inflatable/Self-Rigidizable Reflectarray Antenna.

Source record↗

JAXA-NASA Interoperability Demonstration for Application of DTN Under Simulated Rain Attenuation

As is well known, K-band or higher band communications in space link segment often experience intermittent disruptions caused by heavy rainfall. In view of keeping data integrity and establishing autonomous operations under such situation, it is important to consider introducing a tolerance mechanism such as Delay/Disruption Tolerant Networking (DTN). The Consultative Committee for Space Data Systems (CCSDS) is studying DTN as part of the standardization activities for space data systems. As a contribution to CCSDS and a feasibility study for future utilization of DTN, Japan Aerospace Exploration Agency (JAXA) and National Aeronautics and Space Administration (NASA) conducted an interoperability demonstration for confirming its tolerance mechanism and capability of automatic operation using Data Relay Test Satellite (DRTS) space link and its ground terminals. Both parties used the Interplanetary Overlay Network (ION) open source software, including the Bundle Protocol, the Licklider Transmission Protocol, and Contact Graph Routing. This paper introduces the contents of the interoperability demonstration and its results.

Suzuki, Kiyoshisa↗

Use of IPsec by Manned Space Missions

NASA's Constellation Program is developing its next generation manned space systems for missions to the International Space Station (ISS) and the Moon. The Program is embarking on a path towards standards based Internet Protocol (IP) networking for space systems communication. The IP based communications will be paired with industry standard security mechanisms such as Internet Protocol Security (IPsec) to ensure the integrity of information exchanges and prevent unauthorized release of sensitive information in-transit. IPsec has been tested in simulations on the ground and on at least one Earth orbiting satellite, but the technology is still unproven in manned space mission situations and significant obstacles remain.

Pajevski, Michael J.↗

Bone Loss During Spaceflight: Available Models and Counter-Measures

There is ongoing concern for human health during spaceflights. Of particular interest is the uncoupling of bone remodeling and its resultant effect on calcium metabolism and bone loss. The calculated average loss of bone mineral density (BMD) is approximately 1-1.5% per month of spaceflight. The effect of decreased BMD on associated fractures in astronauts is not known. Currently on the International Space Station (ISS), bone loss is managed through dietary supplements and modifications and resistance exercise regimen. As the duration of space flights increases, a review of the current methods available for the prevention of bone loss is warranted. The goal of this project is to review and summarize recent studies that have focused on maintaining BMD during exposure to microgravity. Interventions were divided into physical (Table 1), nutritional (Table 2), or pharmacologic (Table 3) categories. Physical modalities included resistance exercise, low level vibration, and low intensity pulsed ultrasound. Nutritional interventions included altering protein, salt, and fat intake; and vitamin D supplementation. Pharmacologic interventions included the use of bisphosphonates and beta blockers. Studies reported outcomes based on bone density determined by DXA bone scan, micro-architecture of histology and microCT, and serum and urine markers of bone turnover. The ground analog models utilized to approximate osseous physiology in microgravity included human patients previously paralyzed or subjects confined to bedrest. Ground analog animal models include paralysis, immobilization and ovariectomies. As a result of the extensive research performed there is a multi-modality approach available for the management of BMD during spaceflight that includes resistance training, nutrition and dietary supplements. However, there is a paucity of literature describing a formalized tiered protocol to guide investigators through the progression from animal models to human patient ground analogs to experiments on the ISS. With regards to testing, further evaluation to determine the association between non-invasive tests and fracture during and after spaceflight needs to be performed.

Morris, Jonathan↗

Calibration and Validation of a Finite ELement Model of THor-K Anthropomorphic Test Device for Aerospace Safety Applications

The THOR anthropomorphic test device (ATD) has been developed and continuously improved by the National Highway Traffic Safety Administration to provide automotive manufacturers an advanced tool that can be used to assess the injury risk of vehicle occupants in crash tests. Recently, a series of modifications were completed to improve the biofidelity of THOR ATD [1]. The updated THOR Modification Kit (THOR-K) ATD was employed at Wright-Patterson Air Base in 22 impact tests in three configurations: vertical, lateral, and spinal [2]. Although a computational finite element (FE) model of the THOR had been previously developed [3], updates to the model were needed to incorporate the recent changes in the modification kit. The main goal of this study was to develop and validate a FE model of the THOR-K ATD. The CAD drawings of the THOR-K ATD were reviewed and FE models were developed for the updated parts. For example, the head-skin geometry was found to change significantly, so its model was re-meshed (Fig. 1a). A protocol was developed to calibrate each component identified as key to the kinematic and kinetic response of the THOR-K head/neck ATD FE model (Fig. 1b). The available ATD tests were divided in two groups: a) calibration tests where the unknown material parameters of deformable parts (e.g., head skin, pelvis foam) were optimized to match the data and b) validation tests where the model response was only compared with test data by calculating their score using CORrelation and Analysis (CORA) rating system. Finally, the whole ATD model was validated under horizontal-, vertical-, and lateral-loading conditions against data recorded in the Wright Patterson tests [2]. Overall, the final THOR-K ATD model developed in this study is shown to respond similarly to the ATD in all validation tests. This good performance indicates that the optimization performed during calibration by using the CORA score as objective function is not test specific. Therefore confidence is provided in the ATD model for uses in predicting response in test conditions not performed in this study such those observed in the spacecraft landing. Comparison studies with ATD and human models may also be performed to contribute to future changes in THOR ATD design in an effort to improve its biofidelity, which has been traditionally based on post-mortem human subject testing and designer experience.

Putnam, J. B.↗

Advanced Cardiac Life Support (ACLS) utilizing Man-Tended Capability (MTC) hardware onboard Space Station Freedom

Because of the time and distance involved in returning a patient from space to a definitive medical care facility, the capability for Advanced Cardiac Life Support (ACLS) exists onboard Space Station Freedom. Methods: In order to evaluate the effectiveness of terrestrial ACLS protocols in microgravity, a medical team conducted simulations during parabolic flights onboard the KC-135 aircraft. The hardware planned for use during the MTC phase of the space station was utilized to increase the fidelity of the scenario and to evaluate the prototype equipment. Based on initial KC-135 testing of CPR and ACLS, changes were made to the ventricular fibrillation algorithm in order to accommodate the space environment. Other constraints to delivery of ACLS onboard the space station include crew size, minimum training, crew deconditioning, and limited supplies and equipment. Results: The delivery of ACLS in microgravity is hindered by the environment, but should be adequate. Factors specific to microgravity were identified for inclusion in the protocol including immediate restraint of the patient and early intubation to insure airway. External cardiac compressions of adequate force and frequency were administered using various methods. The more significant limiting factors appear to be crew training, crew size, and limited supplies. Conclusions: Although ACLS is possible in the microgravity environment, future evaluations are necessary to further refine the protocols. Proper patient and medical officer restraint is crucial prior to advanced procedures. Also emphasis should be placed on early intubation for airway management and drug administration. Preliminary results and further testing will be utilized in the design of medical hardware, determination of crew training, and medical operations for space station and beyond.

Smith, M.↗

In-Depth Analysis of Subject Functional Performance and Subjective Feedback Data for Evaluating Argos Simulation Quality

Mechanical offloading systems such as the Active Response Gravity Offload System (ARGOS) at NASA Johnson Space Center (JSC) are used to simulate various partial gravity environments. ARGOS offloads pressurized suited subjects through a gimbaling pivot point system attached to a volumetric Portable Life Support System (PLSS). The pivot point can be configured to multiple locations with respect to the human-suit system center of gravity (CG). Previous work has tested and documented the interaction between different pivot point locations and measured CG. Observations indicated that small changes in pivot point location substantially affect the stability and functional performance (simulation quality) of a subject. This led to the development of a standardized gimbal assessment protocol to assess the functional performance of a pressurized suited subject as a function of the pivot point location, using the data obtained from a variety of planetary suit mobility tasks. As a result, an expansive repository of CG-related task metrics was generated from numerous ARGOS spacesuit test events, for different gimbal configurations and different test subjects. Based on the evaluation metrics and observed trends, several pivot point locations were iteratively identified to determine an “appropriate/optimal” configuration. This study thus describes the in-depth analysis of the CG evaluation metrics to better quantify trends and determine if specific factors are strongly associated with appropriate/optimal configurations. Quantitative and qualitative variables relating to subject task performance, subjective feedback, and anthropometry will be evaluated via probabilistic methods. The results from this study are expected to improve our understanding of optimal ARGOS gimbal settings, which will better inform the gimbal configuration identification process and improve simulation quality for extravehicular activity (EVA) training.

Joseph Yao↗

WISE-2005: LBNP/Treadmill and Resistive Exercise Countermeasures Maintain Aerobic Capacity during a 60-d Bed Rest

We have previously documented that supine treadmill exercise within lower body negative pressure (LBNPex) performed 6 sessions (raised dot) wk(sup -1) during 15- and 30-day bed rests (BR) maintained upright aerobic capacity (VO2pk). In the present study, ure are evaluating whether aerobic capacity is maintained during a 60-d BR when the LBNPex frequency is reduced to 2-4 sessions (raised dot) wk(sup -1) and resistance exercise (REX) is added 2-3 sessions (raised dot) wk(sup -1). Eight healthy women (32 plus or minus 4 yrs; 56.4 plus or minus 3.6 kg; 164 plus or minus 8 cm; mean plus or minus SD) performed maximal-exertion, graded treadmill tests before and 3 days after a 60-d, 6 deg. head-down tilt BR. (Earliest day the medical monitors would permit a maximal exercise test post-BR). During BR, four subjects performed no exercise (CON), while four other subjects (EX) performed LBNPex and REX on separate days. The LBNPex countermeasure employed an intermittent (40-80% pre-BR VO2pk), 40-min protocol against an LBNP pressure (-49 plus or minus 3 mmHg) applied to provide a footward force equivalent to 1.0-1.2 body weight. REX consisted of maximal concentric and eccentric supine leg press and heel raise exercises using a gravity-independent flywheel ergometer. Comparisons were performed using paired (within-group) or non-paired (between-group) t-tests. Three days post-BR, VO2pk of the CON group was reduced significantly from pre-BR (Pre:37.2 plus or minus 1.2, Post: 29.4 plus or minus 2 ml (raised dot) kg(sup -1) (raised dot) min(sup -1), P less than 0.05), while the VO2pk of the EX group was not significantly reduced (Pre: 39.6 plus or minus 1.9, Post: 38.0 plus or minus 0.6 ml (raised dot) kg(sup -1) (raised dot) min(sup -1)). Peak heart rate, ventilation, rating of perceived exertion, and respiratory exchange ratio were not significantly different between the two groups pre- and post-BR. These preliminary results suggest that the combined LBNPex and REX countermeasures may be sufficient to maintain upright aerobic capacity after long-duration space flights.

Schneider, Suzanne M.↗