Search NASA⌕ Search

SEARCH · Search NASA

Results for “variable flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Constraints on flows in Horava-Lifshitz gravity by classical solutions

We find exact static stringy solutions of Horava-Lifshitz gravity with the projectability condition but imposing the detailed balance condition near the UV fixed point, and propose a method on constraining the possible pattern of flows in Horava-Lifshitz gravity by using the obtained classical solutions. In the obtained vacuum solutions, the parameters related to the speed of the graviton and the coefficients of quartic spatial derivative terms lead to intriguing effects: the change of graviton speed yields a surplus angle and the quartic derivatives make the square of effective electric charge negative. The result of a few tests based on the geometries of a cone, an excess cone, a black string, and a charged (black) string seems suggestive. For example, the flow of constant graviton speed and variable Newton's coupling can be favored in the vicinity of an IR fixed point, but the conclusion is indistinct and far from definite yet. Together with the numerous classical solutions, static or time dependent, which have already been found, the accumulated data from various future tests will give some hints in constraining the flow patterns more deterministic.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Understanding Spatial and Spectral Morphologies of Ultracompact H II Regions

The spatial morphology, spectral characteristics, and time variability of ultracompact H II regions provide strong constraints on the process of massive star formation. We have performed simulations of the gravitational collapse of rotating molecular cloud cores, including treatments of the propagation of ionizing and non-ionizing radiation. We here present synthetic radio continuum observations of H II regions from our collapse simulations, to investigate how well they agree with observation, and what we can learn about how massive star formation proceeds. We find that intermittent shielding by dense filaments in the gravitationally unstable accretion flow around the massive star leads to highly variable H II regions that do not grow monotonically, but rather flicker, growing and shrinking repeatedly. This behavior appears able to resolve the well-known lifetime problem. We find that multiple ionizing sources generally form, resulting in groups of ultracompact H II regions, consistent with observations. We confirm that our model reproduces the qualitative H II region morphologies found in surveys, with generally consistent relative frequencies. We also find that simulated spectral energy distributions (SEDs) from our model are consistent with the range of observed H II region SEDs, including both regions showing a normal transition from optically thick to optically thin emission, and those with intermediate spectral slopes. In our models, anomalous slopes are solely produced by inhomogeneities in the H II region, with no contribution from dust emission at millimeter or submillimeter wavelengths. We conclude that many observed characteristics of ultracompact H II regions appear consistent with massive star formation in fast, gravitationally unstable, accretion flows.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lessons Learned in the Update of a Safety Limit for the High Flux Isotope Reactor

A recent unreviewed safety question (USQ) regarding a portion of the High Flux Isotope Reactor (HFIR) transient decay heat removal analysis focused on applicability of a heat transfer correlation at the low flow end of reactor operations. During resolution of this issue, review of the correlations used to establish the safety limit (SL) on reactor flux-to-flow ratio revealed the need to change the magnitude of the SL at the low flow end of reactor operations and the need to update the hot spot fuel damage criteria to incorporate current knowledge involving parallel channel flow stability. Because of the original safety design strategy for the reactor, resolution of the issues for the flux-to-flow ratio involved reevaluation of all key process variable SLs and limiting control settings (LCSs) using the current version of the heat transfer analysis code for the reactor. Goals of the work involved updating and upgrading the SL analysis where necessary, while preserving the safety design strategy for the reactor. Changes made include revisions to the safety design criteria at low flows to address the USQ, update of the process- and analysis input-variable uncertainty considerations, and upgrade of the safety design criteria at high flow. The challenges faced during update/upgrade of this SL and LCS are typical of the problems found in the integration of safety into the design process for a complex facility. In particular, the problems addressed in the area of instrument uncertainties provide valuable lessons learned for establishment and configuration control of SLs for large facilities.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Systems Modeling, Simulation and Material Operating Requirements for Chemical Hydride Based Hydrogen Storage

Research on ammonia borane (AB, NH3BH3) has shown it to be a promising material for chemical hydride based hydrogen storage. AB was selected by DOE's Hydrogen Storage Engineering Center of Excellence (HSECoE) as the initial chemical hydride of study because of its high hydrogen storage capacity (up to 19.6% by weight for the release of {approx}2.5 molar equivalents of hydrogen gas) and its stability under typical ambient conditions. A new systems concept based on augers, ballast tank, hydrogen heat exchanger and H2 burner was designed and implemented in simulation. In this design, the chemical hydride material was assumed to produce H2 on the augers itself, thus minimizing the size of ballast tank and reactor. One dimensional models based on conservation of mass, species and energy were used to predict important state variables such as reactant and product concentrations, temperatures of various components, flow rates, along with pressure, in various components of the storage system. Various subsystem components in the models were coded as C language S-functions and implemented in Matlab/Simulink environment. The control variable AB (or alane) flow rate was determined through a simple expression based on the ballast tank pressure, H2 demand from the fuel cell and hydrogen production from AB (or alane) in the reactor. System simulation results for solid AB, liquid AB and alane for both steady state and transient drive cycle cases indicate the usefulness of the model for further analysis and prototype development.

08 HYDROGEN↗

THE TEMPERATURE OF HOT GAS HALOS OF EARLY-TYPE GALAXIES

Recently, the temperature T and the luminosity L{sub X} of the hot gas halos of early-type galaxies have been derived, with unprecedented accuracy, from Chandra data for a sample of 30 galaxies, covering a wider range of galactic luminosity (and central velocity dispersion {sigma}{sub c}) than before. This work investigates the origin of the observed temperatures by examining the relationship between them and the galaxy structure, the gas heating due to Type ia supernovae (SNe ia) and the gravitational potential, and the dynamical status of the gas flow. In galaxies with {sigma}{sub c} {approx}< 200 km s{sup -1}, the T's are close to a fiducial average temperature of gas in outflow; at 200 < {sigma}{sub c} (km s{sup -1}) < 250, the T's are generally lower than this and unrelated to {sigma}{sub c}, which requires a more complex gas flow status; at larger {sigma}{sub c}, the T's may increase as {sigma}{sup 2}{sub c}, as expected for infall heating, though heating from SNe ia, that is independent of {sigma}{sub c}, should be dominant. All observed T's are larger than the virial temperature, by up to {approx}0.5 keV. The additional heating can be provided in the X-ray brightest galaxies by SNe ia and infall heating, with an SN ia energy input even lower than in standard assumptions; in the X-ray fainter ones it can be provided by SNe ia, whose energy input would be required to be close to the full standard value at the largest {sigma}{sub c}. This same energy input, though, would produce temperatures larger than observed at low {sigma}{sub c} if entirely thermalized. The values of the observed T's increase from outflows to inflows; the gas is relatively hotter in outflows, however, if the T's are rescaled by the virial temperature. For 200 < {sigma}{sub c}(km s{sup -1}) < 250, lower L{sub X} values tend to correspond to lower T's, a result that deserves further investigation.

79 ASTRONOMY AND ASTROPHYSICS↗

Ecosystem warming increases sap flow rates of northern red oak trees

Abstract Over the next century, air temperature increases up to 5°C are projected for the northeastern United States. As evapotranspiration strongly influences water loss from terrestrial ecosystems, the ecophysiological response of trees to warming will have important consequences for forest water budgets. We measured growing season sap flow rates in mature northern red oak ( Quercus rubra L.) trees in a combined air (up to 5.5°C above ambient) and soil (up to 1.85°C above ambient at 6‐cm depth) warming experiment at Harvard Forest, Massachusetts, United States. Through principal components analysis, we found air and soil temperatures explained the largest amount of variance in environmental variables associated with rates of sap flow, with relative humidity, photosynthetically active radiation and vapor pressure deficit having significant, but smaller, effects. On average, each 1°C increase in temperature increased sap flow rates by approximately 1100 kg H 2 O m −2 sapwood area day −1 throughout the growing season and by 1200 kg H 2 O m −2 sapwood area day −1 during the early growing season. Reductions in the number of cold winter days correlated positively with increased sap flow during the early growing season (a decrease in 100 heating‐degree days was associated with a sapflow increase in approximately 5 kg H 2 O m −2 sapwood area day −1 ). Soil moisture declined with increased treatment temperatures, and each soil moisture percentage decrease resulted in a decrease in sap flow of approximately 360 kg H 2 O m −2 sapwood area day −1 . At night, soil moisture correlated positively with sap flow. These results demonstrate that warmer air and soil temperatures in winter and throughout the growing season lead to increased sap flow rates, which could affect forest water budgets throughout the year.

54 ENVIRONMENTAL SCIENCES↗

Improving air leakage prediction of buildings using the fan pressurization method with the Weighted Line of Organic Correlation

In many countries, the fan pressurization method is the most frequently chosen approach for measuring the air leakage of houses. The measurements are usually performed at pressures that far exceed pressures to which buildings are exposed to under normal conditions. A fit of these tests to the power-law formulation allows an extrapolation to data points outside the measured pressure range. With the Ordinary Least Square (OLS) fitting method, the pressure exponent and flow coefficient can be determined. However, the measurement results are highly sensitive to uncertainties induced by external factors like changing wind conditions during the tests, which is neglected by OLS. This may lead to errors in the prediction of flows at lower pressures. The Weighted Line of Organic Correlation (WLOC) is an alternative approach and takes measurement uncertainty into account. In this paper, a statistical analysis of an extensive data set of pressurization measurements has been performed. Both regression techniques have been compared for almost 7500 fan pressurization measurements of six houses in 109 different house leak configurations. The variability in predicting pressure exponent and flow coefficient for both WLOC and OLS regression was analyzed using probability density functions. It was found that the Weighted Line of Organic Correlation significantly decreases the uncertainty in predicting pressure exponent, flow coefficient, and other low-pressure air leakage metrics compared to the Ordinary Least Square fitting. Here, the authors highly recommend the implementation of WLOC in current measurement standards and test equipment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Phase-change valves and related methods

Valves may include an opening sized and shaped to permit a subject fluid to flow through the opening when the opening is unobstructed. A heat exchange element may be located proximate to the opening, the heat exchange element positioned and configured to induce a localized phase change in the subject fluid to form and unform a solid plug from the subject fluid around at least a portion of the heat exchange element. A heat transfer rate of the heat exchange element may be variable to control a rate of flow of the subject fluid through the valve by controlling a size of the solid plug from the subject fluid.

Sabharwall, Piyush↗

Effects of Atwood and Reynolds numbers on the evolution of buoyancy-driven homogeneous variable-density turbulence

The evolution of buoyancy-driven homogeneous variable-density turbulence (HVDT) at Atwood numbers up to 0.75 and large Reynolds numbers is studied by using high-resolution direct numerical simulations. To help understand the highly non-equilibrium nature of buoyancy-driven HVDT, the flow evolution is divided into four different regimes based on the behaviour of turbulent kinetic energy derivatives. The results show that each regime has a unique type of dependence on both Atwood and Reynolds numbers. It is found that the local statistics of the flow based on the flow composition are more sensitive to Atwood and Reynolds numbers compared to those based on the entire flow. It is also observed that, at higher Atwood numbers, different flow features reach their asymptotic Reynolds-number behaviour at different times. The energy spectrum defined based on the Favre fluctuations momentum has less large-scale contamination from viscous effects for variable-density flows with constant properties, compared to other forms used previously. The evolution of the energy spectrum highlights distinct dynamical features of the four flow regimes. Thus, the slope of the energy spectrum at intermediate to large scales evolves from -7/3 to -1 , as a function of the production-to-dissipation ratio. The classical Kolmogorov spectrum emerges at intermediate to high scales at the highest Reynolds numbers examined, after the turbulence starts to decay. Finally, the similarities and differences between buoyancy-driven HVDT and the more conventional stationary turbulence are discussed and new strategies and tools for analysis are proposed.

42 ENGINEERING↗

A Data-Driven Approach to Dynamic Var Compensator Placement for Local Voltage Stabilization on Feeders with High PV Penetration

Distribution feeders with a high penetration of distributed photovoltaic (PV) systems can experience voltage variability caused by the changing load flow injections corresponding to the availability of the solar resource. The rapid, uncontrolled voltage range fluctuations can affect the system. Tap-changing voltage regulators, switched capacitors, and smart inverter functions have been used to stabilize voltage. However, in some cases, when these options are insufficient or unavailable, dedicated reactive power control devices such as dynamic var compensators (DVCs) can be used for local voltage stabilization. This paper introduces a statistical framework to characterize voltage variability and stabilization, proposes a data-driven approach to DVC placement, and presents the results of a planning study on a real feeder using real data.

Reiman, Andrew P.↗

Neutron Imaging Calibration to Measure Void Fraction

Void fraction is an intuitive parameter that describes the fraction of vapor in a two-phase flow. It appears as a key variable in most heat transfer and pressure drop correlations used to design evaporating and condensing heat exchangers, as well as determining charge inventory in refrigeration systems. Void fraction measurement is not straightforward, however, and assumptions on the invasiveness of the measuring technique must be made. Neutron radiography or neutron imaging has the potential to be a truly non-invasive void fraction measuring technique but has until recently only offered qualitative descriptions of two-phase flow, in terms of flow maldistributions, for example. This paper describes the calibration approach necessary to employ neutron imaging to measure steady-state void fraction. Experiments were conducted at the High Flux Isotope Reactor (HFIR) Cold Guide 1D neutron imaging facility at Oak Ridge National Laboratory (ORNL), Oak Ridge, TN, USA.

42 ENGINEERING↗

Understanding the compound flood risk along the coast of the contiguous United States

Abstract. Compound flooding is a type of flood event caused by multiple flood drivers. The associated risk has usually been assessed using statistics-based analyses or hydrodynamics-based numerical models. This study proposes a compound flood (CF) risk assessment (CFRA) framework for coastal regions in the contiguous United States (CONUS). In this framework, a large-scale river model is coupled with a global ocean reanalysis dataset to (a) evaluate the CF exposure related to the coastal backwater effects on river basins, and (b) generate spatially distributed data for analyzing the CF hazard using a bivariate statistical model of river discharge and storm surge. The two kinds of risk are also combined to achieve a holistic understanding of the continental-scale CF risk. The estimated CF risk shows remarkable inter- and intra-basin variabilities along the CONUS coast with more variabilities in the CF hazard over the US west and Gulf coastal basins. Different risk assessment methods present significantly different patterns in a few key regions such as the San Francisco Bay area, the lower Mississippi River, and Puget Sound. Our results highlight the need to weigh different CF risk measures and avoid using single statistics-based or hydrodynamics-based CFRAs. Uncertainty sources in these CFRAs include the use of gauge observations, which cannot account for the flow physics or resolve the spatial variability of risks, and underestimations of the flood extremes and the dependence of CF drivers in large-scale models, highlighting the importance of understanding the CF risks for developing a more robust CFRA.

54 ENVIRONMENTAL SCIENCES↗

Variable High Order Multiblock Overlapping Grid Methods for Mixed Steady and Unsteady Multiscale Viscous Flows

Flows containing steady or nearly steady strong shocks in parts of the flow field, and unsteady turbulence with shocklets on other parts of the flow field are difficult to capture accurately and efficiently employing the same numerical scheme even under the multiblock grid or adaptive grid refinement framework. On one hand, sixth-order or higher shock-capturing methods are appropriate for unsteady turbulence with shocklets. On the other hand, lower order shock-capturing methods are more effective for strong steady shocks in terms of convergence. In order to minimize the shortcomings of low order and high order shock-capturing schemes for the subject flows, a multi-block overlapping grid with different orders of accuracy on different blocks is proposed. Test cases to illustrate the performance of the new solver are included.

99 GENERAL AND MISCELLANEOUS↗

Multi-material incompressible flow simulation using the moment-of-fluid method

The Moment-of-Fluid interface reconstruction technique is implemented in a second order accurate, unstructured finite element variable density incompressible Navier-Stokes solver. For flows with multiple materials, MOF significantly outperforms existing first and second order interface reconstruction techniques. For two material flows, the performance of MOF is similar to other interface reconstruction techniques. For strongly driven bouyant flows, the errors in the flow solution dominate and all the interface reconstruction techniques perform similarly.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Status Update: Uranyl Nitrate Calibration Loop Equipment (UNCLE) at ORNL

The successful completion of a field trial of safeguards monitoring equipment at a natural uranium conversion plant (NUCP) demonstrated the need for a facility in which to perform full-scale equipment testing under controlled conditions prior to field deployment of safeguards systems at additional plants. Oak Ridge National Laboratory has developed a Uranyl Nitrate Calibration Loop Equipment (UNCLE) facility to simulate the full-scale operating conditions for a purified uranium-bearing aqueous stream exiting the solvent extraction process conducted in an NUCP. In addition to calibrating instruments such as the neutron detector developed at Los Alamos National Laboratory, UNCLE will be used to test other in-line instruments (mass and volumetric flowmeters, spectrophotometers, etc.). UNCLE will be able to test commercially available equipment, such as the Endress+Hauser Promass 83F Coriolis meter that was used in the field test and other equipment that is presently under development. UNCLE is designed to accommodate different pipe sizes, flow rates, solution concentrations, and other variables of interest. Construction is expected to be completed by the end of September 2008 with initial testing beginning later that year. The design and current status of UNCLE will be presented, along with the capabilities of the facility and the proposed test plans.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Warming of the lower Columbia River , 1853 to 2018

Abstract Water temperature is a critical ecological indicator; however, few studies have statistically modeled century‐scale trends in riverine or estuarine water temperature, or their cause. Here, we recover, digitize, and analyze archival temperature measurements from the 1850s onward to investigate how and why water temperatures in the lower Columbia River are changing. To infill data gaps and explore changes, we develop regression models of daily historical Columbia River water temperature using time‐lagged river flow and air temperature as the independent variables. Models were developed for three time periods (mid‐19th, mid‐20th, and early 21st century), using archival and modern measurements (1854–1876; 1938–present). Daily and monthly averaged root‐mean‐square errors overall are 0.89°C and 0.77°C, respectively for the 1938–2018 period. Results suggest that annual averaged water temperature increased by 2.2°C ± 0.2°C since the 1850s, a rate of 1.3°C ± 0.1°C/century. Increased water temperatures are seasonally dependent. An increase of approximately 2.0°C ± 0.2°C/century occurs in the July–Dec time‐frame, while springtime trends are statistically insignificant. Rising temperatures change the probability of exceeding ecologically important thresholds; since the 1850s, the number of days with water temperatures over 20°C increased from ~5 to 60 per year, while the number below 2°C decreased from ~10 to 0 days/per year. Overall, the modern system is warmer, but exhibits less temperature variability. The reservoir system reduces sensitivity to short‐term atmospheric forcing. Statistical experiments within our modeling framework suggest that increased water temperature is driven by warming air temperatures (~29%), altered river flow (~14%), and water resources management (~57%).

54 ENVIRONMENTAL SCIENCES↗

Hierarchical Krylov and nested Krylov methods for extreme-scale computing

The solution of large, sparse linear systems is typically a dominant phase of computation for simulations based on partial differential equations, which are ubiquitous in scientific and engineering applications. While preconditioned Krylov methods are widely used and provide many advantages for solving sparse linear systems that do not have highly convergent, geometric multigrid solvers or specialized fast solvers, Krylov methods encounter well-known scaling difficulties for over 10,000 processor cores because each iteration requires at least one vector inner product, which in turn requires a global synchronization that scales poorly because of internode latency. To aid in overcoming these difficulties, we have developed hierarchical Krylov methods and nested Krylov methods in the PETSc library that reduce the number of global inner products required across the entire system (where they are expensive), though freely allow vector inner products across smaller subsets of the entire system (where they are inexpensive) or use inner iterations that do not invoke vector inner products at all. Nested Krylov methods are a generalization of inner-outer iterative methods with two or more layers. Hierarchical Krylov methods are a generalization of block Jacobi and overlapping additive Schwarz methods, where each block itself is solved by Krylov methods on smaller blocks. Conceptually, the hierarchy can continue recursively to an arbitrary number of levels of smaller and smaller blocks. As a specific case, we introduce the hierarchical FGMRES method, or h-FGMRES, and we demonstrate the impact of two-level h-FGMRES with a variable preconditioner on the PFLOTRAN subsurface flow application. We also demonstrate the impact of nested FGMRES, BiCGStab and Chebyshev methods. These hierarchical Krylov methods and nested Krylov methods significantly reduced overall PFLOTRAN simulation time on the Cray XK6 when using 10,000 through 224,000 cores through the combined effects of reduced global synchronization due to fewer global inner products and stronger inner hierarchical or nested preconditioners.

97 MATHEMATICS AND COMPUTING↗

Evolution of chemical conditions and estimated solubility controls on radionuclides in the residual waste layer during post-closure aging of high-level waste tanks

This document provides information specific to H-Area waste tanks that enables a flow and transport model with limited chemical capabilities to account for varying waste release from the tanks through time. The basis for varying waste release is solubilities of radionuclides that change as pore fluids passing through the waste change in composition. Pore fluid compositions in various stages were generated by simulations of tank grout degradation. The first part of the document describes simulations of the degradation of the reducing grout in post-closure tanks. These simulations assume flow is predominantly through a water saturated porous medium. The infiltrating fluid that reacts with the grout is assumed to be fluid that has passed through the closure cap and into the tank. The results are three stages of degradation referred to as Reduced Region II, Oxidized Region II, and Oxidized Region III. A reaction path model was used so that the transitions between each stage are noted by numbers of pore volumes of infiltrating fluid reacted. The number of pore volumes to each transition can then be converted to time within a flow and transport model. The bottoms of some tanks in H-Area are below the water table requiring a different conceptual model for grout degradation. For these simulations the reacting fluid was assumed to be 10% infiltrate through the closure cap and 90% groundwater. These simulations produce an additional four pore fluid compositions referred to as Conditions A through D and were intended to simulate varying degrees of groundwater influence. The most probable degradation path for the submerged tanks is Condition C to Condition D to Oxidized Region III and eventually to Condition A. Solubilities for Condition A are estimated in the text for use in sensitivity analyses if needed. However, the grout degradation simulations did not include sufficient pore volumes of infiltrating fluid for the grout to evolve to Condition A. Solubility controls for use in a flow and transport model were estimated for 27 elements in each of the chemical stages generated in the grout simulations plus local groundwater. The grout simulations were run with the initial infiltrating fluid in equilibrium with atmospheric oxygen to account for degradation of the reduction capacity of the grout. However, a lower Eh was used in pore fluids in the oxidizing conditions used to estimate solubilities to be more consistent with measured Eh values and natural systems. Solubilities of plutonium are affected by this decision, but those of other elements are not. In addition, the baseline for H-Area tanks is that they will be washed with oxalic acid prior to being filled with grout. Hence, oxalate was included in the pore fluids by assuming equilibrium with calcium oxalate. Solubility estimates were done by equilibrating a solubility controlling phase for each element with the pore fluid compositions using The Geochemist’s Workbench®. Condition B pore fluids are similar to Condition D. Therefore, solubilities for Condition B were not estimated, but assumed to be the same as in Condition D. In general solubility controlling phases were selected to bias solubilities to higher values. Several elements had no solubility controls and solubility estimates for other elements were omitted because the elements had short half-lives or were present in residual waste in very low amounts. For these it is recommended that release from the tank be instantaneous when the tank liner is breached. There is considerable uncertainty in this approach to enabling a flow and transport model to account for variable waste release. Yet, it is also flexible and requires much less computing time than a fully coupled reactive transport model. This allows some of the uncertainty to be addressed by multiple flow and transport sensitivity cases. Some of the uncertainties are addressed within this document. These include uncertainty in infiltrate composition, grout mineralogy, and disposition of certain components during the simulations. Uncertainty in the solubility estimates is addressed in part by examining sensitivity of solubilities for four key elements to uncertainty in thermodynamic data, pH, Eh, total inorganic carbon concentration, and oxalate concentration. In addition, the solubilities for the elements estimated here are compared to two other compilations of solubilities in cementitious materials.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗