Search NASA⌕ Search

SEARCH · Search NASA

Results for “variable generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31

Numerical Methods to Evaluate Hyperelastic Transducers: Hexagonal Distributed Embedded Energy Converters

Hexagonal distributed embedded energy converters, also known as hexDEECs, are centimeter-scale energy transducers that leverage variable capacitance to generate electricity when their hyperelastic structure is dynamically deformed. To better understand, characterize, and optimize hexDEEC designs, a series of numerical methods and techniques were developed to model the hyperelastic mechanics of hexDEECs, electrostatic properties, and electricity generation characteristics. The numerical methods developed for the hyperelastic structural analysis were corroborated by empirical results from another study, and the models and equations for capacitance, electrostatic forces, and electrical potential energy were derived from fundamental electrostatic equations. These methods and techniques were implemented within the STAR-CCM+ multiphysics software Version 2020.3 (15.06.008) environment. Results from this analysis revealed methodologies and techniques necessary to model the energy converters, which will enable future exploration and optimization of more specific designs and corresponding applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Industrial Energy Storage Review

As the United States moves to net-zero carbon emission by 2050, a transition to renewable energy generation is required. However, the variable nature of renewable energy generation at high penetrations can cause imbalances in generation and transmission of electricity. These imbalances can be circumvented by the deployment of energy storage. Global industrial energy storage is projected to grow 2.6 times in the coming decades, from just over 60 GWh to 167 GWh in 2030. The challenge is to balance energy storage capabilities with the power and energy needs for particular industrial applications. Energy storage technologies can be classified by the form of the stored energy. The most common forms include thermal, chemical, electrochemical, and mechanical storage technologies. The most appropriate storage technology will depend on the unique energy needs of the industrial application. The purpose of this report is to provide a review of energy storage technologies relevant to the U.S. industrial sector, highlighting the applications in industry that will benefit from increased integration of energy storage, as well as the respective challenges and opportunities unique to integrating different storage technologies.

25 ENERGY STORAGE↗

Development of a 95-Year Solar Dataset for Resource Adequacy Studies

Long-term high-resolution solar data provides enhanced understanding of variability of solar generation and enhances our ability to develop strategies for a resilient and reliable electric grid under high deployment of solar energy. Therefore, it is important to develop long-term synthetic datasets that can provide multiple occurrences of various severe weather scenarios that are expected to test the limits of resource adequacy under scenarios contain various energy generation sources. Examples of such scenarios could be long periods of high temperatures when demand for electricity is high or periods where high winds could lead to a shut-down of transmission lines for long periods of time to ensure fire safety. NREL has developed the first version of such a dataset covering a 95-year period covering 2006-2100 at a 4km hourly resolution. This dataset contains all variables necessary to calculate solar generation. During development of this dataset, we focused on creating unbiased, high-resolution solar irradiance through statistical downscaling methods, using Regional Climate Model (RCM) simulations from the North American Coordinated Regional Climate Downscaling Experiment (NA-CORDEX) as input. The National Solar Radiation Database (NSRDB) containing over 25 years of observations was used to calibrate the statistical downscaling models. This presentation will outline the primary steps in developing this dataset, including (1) regridding RCM data to a common grid at 20-km resolution, (2) correcting RCM biases with NSRDB, (3) applying temporal and spatial downscaling methods to generate high-resolution (4-km, hourly) solar and ancillary data. Additionally, we will present an evaluation of the downscaled data against the NSRDB across various zones in the CONUS. Lastly, we will present a user guide for accessing the datasets.

14 SOLAR ENERGY↗

Variability of interconnected wind plants: correlation length and its dependence on variability time scale

The variability in wind-generated electricity complicates the integration of this electricity into the electrical grid. This challenge steepens as the percentage of renewably-generated electricity on the grid grows, but variability can be reduced by exploiting geographic diversity: correlations between wind farms decrease as the separation between wind farms increases. However, how far is far enough to reduce variability? Grid management requires balancing production on various timescales, and so consideration of correlations reflective of those timescales can guide the appropriate spatial scales of geographic diversity grid integration. To answer 'how far is far enough,' we investigate the universal behavior of geographic diversity by exploring wind-speed correlations using three extensive datasets spanning continents, durations and time resolution. First, one year of five-minute wind power generation data from 29 wind farms span 1270 km across Southeastern Australia (Australian Energy Market Operator). Second, 45 years of hourly 10 m wind-speeds from 117 stations span 5000 km across Canada (National Climate Data Archive of Environment Canada). Finally, four years of five-minute wind-speeds from 14 meteorological towers span 350 km of the Northwestern US (Bonneville Power Administration). After removing diurnal cycles and seasonal trends from all datasets, we investigate dependence of correlation length on time scale by digitally high-pass filtering the data on 0.25–2000 h timescales and calculating correlations between sites for each high-pass filter cut-off. Correlations fall to zero with increasing station separation distance, but the characteristic correlation length varies with the high-pass filter applied: the higher the cut-off frequency, the smaller the station separation required to achieve de-correlation. Remarkable similarities between these three datasets reveal behavior that, if universal, could be particularly useful for grid management. For high-pass filter time constants shorter than about τ = 38 h, all datasets exhibit a correlation length $\xi $ that falls at least as fast as ${{\tau }^{-1}}$ . Since the inter-site separation needed for statistical independence falls for shorter time scales, higher-rate fluctuations can be effectively smoothed by aggregating wind plants over areas smaller than otherwise estimated.

17 WIND ENERGY↗

An experimental setup to study the expansion dynamics of laser blow-off plasma plume in variable transverse magnetic field

In the present work we report generation of uniform and variable pulsed magnetic field in synchronization with pulsed plasma for the study of the expansion dynamics of laser blow-off (LBO) plasma plume. The experimental procedure for optimizing various parameters of the setup, e.g., the production of pulsed field and its synchronization with pulsed plasma and diagnostics system, is also reported. Until now the effect of magnetic field was studied using fixed field. The present setup, however, provides variable and uniform field in synchronization with the setup. A low cost time sequencing control module has been developed for the above purpose. Although the main emphasis is on the technical aspect of the setup, salient features of the effect of transverse magnetic field on the evolution features of the neutral and ionic species are also reported briefly. It is observed that LBO generated plume have a stronger correlation with the magnetic field in comparison to the conventional laser produced plasma experiments as reported earlier.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic parameter estimation of generators

Various examples are provided for parameter estimation of generators. In one example, among others, a method includes collecting data corresponding to a generator using a phasor management unit (PMU) and estimating dynamic parameters of the generator using extended Kalman filtering (EKF) and the collected PMU data. In another example, a system includes at least one application executable in a processing device that obtains operational data corresponding to a generator and estimates a dynamic parameter of the generator using EKF and the operational data. In another example, an EKF estimator includes a dynamics estimator configured to estimate a state variable of a generator, a geometry estimator configured to estimate phasor values associated with the generator, and a Kalman filter gain configured to determine a correction to the state variable.

Miao, Zhixin↗

Experimental Comparison of PV-Smoothing Controllers using Distributed Generators

The power output variability of photovoltaic systems can affect local electrical grids in locations with high renewable energy penetrations or weak distribution or transmission systems. In those rare cases, quick controllable generators (e.g., energy storage systems) or loads can counteract the destabilizing effects by compensating for the power fluctuations. Previously, control algorithms for coordinated and uncoordinated operation of a small natural gas engine-generator (genset) and a battery for smoothing PV plant output were optimized using MATLAB/Simulink simulations. The simulations demonstrated that a traditional generation resource such as a natural gas genset in combination with a battery would smooth the photovoltaic output while using a smaller battery state of charge (SOC) range and extending the life of the battery. This paper reports on the experimental implementation of the coordinated and uncoordinated controllers to verify the simulations and determine the differences in the controllers. The experiments were performed with the PNM PV and energy storage Prosperity site and a gas engine-generator located at the Aperture Center at Mesa Del Sol in Albuquerque, New Mexico. Two field demonstrations were performed to compare the different PV smoothing control algorithms: (1) implementing the coordinated and uncoordinated controls while switching off a subsection of the PV array at precise times on successive clear days, and (2) comparing the results of the battery and genset outputs for the coordinated control on a high variability day with simulations of the coordinated and uncoordinated controls. It was found that for certain PV power profiles the SOC range of the battery may be larger with the coordinated control, but the total amp-hours through the battery-which approximates battery wear-will always be smaller with the coordinated control.

14 SOLAR ENERGY↗

FAST VARIABILITY AND MILLIMETER/IR FLARES IN GRMHD MODELS OF Sgr A* FROM STRONG-FIELD GRAVITATIONAL LENSING

We explore the variability properties of long, high-cadence general relativistic magnetohydrodynamic (GRMHD) simulations across the electromagnetic spectrum using an efficient, GPU-based radiative transfer algorithm. We focus on both standard and normal evolution (SANE) and magnetically arrested disk (MAD) simulations with parameters that successfully reproduce the time-averaged spectral properties of Sgr A* and the size of its image at 1.3 mm. We find that the SANE models produce short-timescale variability with amplitudes and power spectra that closely resemble those inferred observationally. In contrast, MAD models generate only slow variability at lower flux levels. Neither set of models shows any X-ray flares, which most likely indicates that additional physics, such as particle acceleration mechanisms, need to be incorporated into the GRMHD simulations to account for them. The SANE models show strong, short-lived millimeter/infrared (IR) flares, with short (≲1 hr) time lags between the millimeter and IR wavelengths, that arise from the combination of short-lived magnetic flux tubes and strong-field gravitational lensing near the horizon. Such events provide a natural explanation for the observed IR flares with no X-ray counterparts.

79 ASTRONOMY AND ASTROPHYSICS↗

Project 57 Air Monitoring Report: October 1, 2013, through December 31, 2014

On April 24, 1957, the Atomic Energy Commission (AEC, now the Department of Energy [DOE]) conducted the Project 57 safety experiment in western Emigrant Valley north east of the Nevada National Security Site (NNSS, formerly the Nevada Test Site) on lands withdrawn by the Department of Defense (DoD) for the Nevada Test and Training Range (NTTR). The test was undertaken to develop (1) a means of estimating plutonium distribution resulting from a nonnuclear detonation; (2) biomedical evaluation techniques for use in plutonium-laden environments; (3) methods of surface decontamination; and (4) instruments and field procedures for prompt estimation of alpha contamination (Shreve, 1958). Although the test did not result in the fission of nuclear materials, it did disseminate plutonium across the land surface. Following the experiment, the AEC fenced the contaminated area and returned control of the surrounding land to the DoD. Various radiological surveys have been performed in the area and in 2007, the DOE expanded the demarked contamination area by posting signs 200 to 400 feet (60 to 120 meters) outside of the original fence. Plutonium in soil is thought to attach preferentially to smaller particles. Therefore, redistribution of soil particulates by wind (dust) is the mechanism most likely to transport plutonium beyond the boundary of the Project 57 contamination area. In 2011, DRI installed two instrumentation towers to measure radiological, meteorological, and dust conditions. The monitoring activity was implemented to determine if radionuclide contamination was detectable in samples of airborne dust and characterize meteorological and environmental parameters that influence dust transport. Collected data also permits comparison of radiological conditions at the Project 57 monitoring stations to conditions observed at Community Environmental Monitoring Program (CEMP) stations around the NTTR. Biweekly samples of airborne particulates are submitted for laboratory assessment of gross alpha and gross beta radioactivity and for determination of gamma-emitting radionuclides. Annual average gross alpha values at the Project 57 monitoring stations are in the same range as the highest two values reported for the CEMP stations surrounding the NTTR. Annual average gross beta values at the Project 57 monitoring stations are slightly higher than the lowest value reported for the CEMP stations surrounding the NTTR. Gamma spectroscopy analyses on samples collected from the Project 57 stations identified only naturally occurring radionuclides. No manmade radionuclides were detected. Thermoluminescent dosimeters (TLDs) indicated that the average annual radioactivity dose at the monitoring stations is higher than the dose determined at surrounding CEMP stations but approximately half of the estimated national average dose received by the general public as a result of exposure to natural sources. The TLDs at the Project 57 monitoring stations are exposed to both natural sources (terrestrial and cosmic) and radioactive releases from the Project 57 contamination area. These comparisons show that the gross alpha, gross beta, and gamma spectroscopy levels at the Project 57 monitoring stations are similar to levels observed at the CEMP stations but that the average annual dose rate is higher than at the CEMP stations. Winds in excess of approximately 15 mph begin to generate dust movement by saltation (migration of sand at the ground surface) or direct suspension in the air. Saltated sand, PM10 (inhalable) dust, and PM2.5 (fine particulate dust) exhibit an approximately exponential increase with increasing wind speed. The greatest concentrations of dust occur for winds exceeding 20 mph. During the reporting period, winds in excess of 20 mph occurred approximately 1.6 percent of the time. Preliminary assessment of individual wind events suggests that dust generation is highly variable likely because of the influence of other meteorological and environmental parameters. Although winds sufficient to generate significant amounts of dust occur at the Project 57 site, they are infrequent and of short duration. Additionally, the potential for wind transport of dust is dependent on other parameters whose influence have not yet been assessed.

54 ENVIRONMENTAL SCIENCES↗

A novel conditional generative model for efficient ensemble forecasts of state variables in large-scale geological carbon storage

Integrating monitoring data to efficiently update reservoir pressure and CO 2 plume distribution forecasts presents a significant challenge in geological carbon storage (GCS) applications. Inverse modeling techniques are commonly used to fuse observational data and refine reservoir model parameters, thereby improving state variable forecasts. However, these techniques often rely on linear or Gaussian assumptions, which can limit their effectiveness in accurately predicting state variables. Moreover, simulating large-scale three-dimensional (3D) GCS problems is computationally expensive, making iterative runs in inverse problems prohibitive. To address these challenges, we propose a conditional generative model utilizing the score-based diffusion method for real-time 3D pressure and saturation field distribution predictions. Our approach involves solving the score function with a mini-batch-based Monte Carlo estimator to generate labeled data. This data is subsequently employed to train a fully connected neural network, enabling it to learn the conditional sample generator within a supervised learning framework. This method enables the rapid generation of a large ensemble of predictions, facilitating comprehensive uncertainty quantification of state variables. Here we applied our method to forecast the dynamic 3D distributions of pressure and saturation fields over a 30-year injection period. The statistical assessment with low root mean square error (RMSE) values demonstrates that our method can accurately predict the spatiotemporal distributions of both pressure and saturation fields. Moreover, the developed conditional generative model shows high computational efficiency by generating 100 ensemble forecasts of 3D state variables in less than 10 min. The consistency between ensemble averages and ground truth values further illustrates the model’s capability to capture state variable dynamics during the CO 2 plume injection process. Notably, the ground truth values fall within the ensemble forecasts, indicating that our uncertainty quantification effectively captures variability and potential noise in the observations. Thus, the developed conditional generative model proves to be a more efficient, accurate, and practical tool for GCS applications, facilitating timely risk analysis and informed decision-making.

58 GEOSCIENCES↗

Wind/PV Generation for Frequency Regulation and Oscillation Damping in the Eastern Interconnection

This report presents the control of renewable energy sources, including the variable-speed wind generators and solar photovoltaic (PV) generators, for frequency regulation and inter-area oscillation damping in the U.S. Eastern Interconnection (EI). In this report, based on the user-defined wind/PV generator electrical control model and the 16,000-bus Eastern Interconnection dynamic model, the additional controllers for frequency regulation and inter-area oscillation damping are developed and incorporated and the potential contributions of renewable energy sources to the EI system frequency regulation and inter-area oscillation damping are evaluated.

14 SOLAR ENERGY↗

Clustering representative days for power systems generation expansion planning: Capturing the effects of variable renewables and energy storage

Decision makers rely on models to make important regulatory, policy, and investment decisions. For power systems, these models must capture (i) the future challenges introduced by the integration of large quantities of variable renewable energy sources and (ii) the role that energy storage technologies should play. In this paper, we explore several different approaches to selecting representative days for generation expansion planning models, focusing on capturing these dynamics. Further, we propose a new methodology for adjusting the outputs of clustering algorithms that provides three advantages: the targeted level of net demand is captured, the underlying net demand shapes that define ramping challenges are accurately represented, and the relationship between annual energy and peak demand is captured. This weighting methodology reduces the magnitude of the error in the representative day based generation expansion planning models estimation of costs by 61% on average. The results also demonstrate the importance of carefully performing the clustering of representative days for both system costs and technology mix. In most cases improvements to the total cost of different representative day based expansion plans are realised where conventional generation capacity is substituted for energy storage. Based on the energy storage technology selected we conclude this capacity is being used to address ramping challenges as opposed to shifting renewable generation from off to on peak periods, reinforcing the importance of capturing detailed intraday dynamics in the representative day selection process.

Clustering↗

Thermal Energy Storage and its Potential Applications in Solar Thermal Power Plants and Electricity Storage

With the rapid growth of renewable power generation, economically storing large quantities of solar- and wind-generated electricity may become as important as renewable power itself. The combination of renewable power generation and energy storage can overcome the variability of renewable power generation alone and create the opportunity for renewable generation to provide base-load electricity.For peak power usage, the integration of renewable power and storage of excess electricity has several significant and positive impacts: expanding the renewable energy portion of total electricity generation, improving the peak-load response, and coordinating the electricity supply and demand over the grid. Several energy storage approaches exist, with mechanical, chemical, and electricalmethods either in use now or being developed. Comparing their efficiencies as well as their economic uses for different scales and applications helps determine the right technology for the right purpose. This paper will study the possibility of using thermal energy storage as a means for electricity storage, and compare it to other energy storage methods including batteries, flywheels, compressed air, and pumped hydropower.

14 SOLAR ENERGY↗

Using Electric Vehicles to Meet Balancing Requirements Associated with Wind Power

Many states are deploying renewable generation sources at a significant rate to meet renewable portfolio standards. As part of this drive to meet renewable generation levels, significant additions of wind generation are planned. Due to the highly variable nature of wind generation, significant energy imbalances on the power system can be created and need to be handled. This report examines the impact on the Northwest Power Pool (NWPP) region for a 2019 expected wind scenario. One method for mitigating these imbalances is to utilize plug-in hybrid electric vehicles (PHEVs) or battery electric vehicles (BEVs) as assets to the grid. PHEVs and BEVs have the potential to meet this demand through both charging and discharging strategies. This report explores the usage of two different charging schemes: V2GHalf and V2GFull. In V2GHalf, PHEV/BEV charging is varied to absorb the additional imbalance from the wind generation, but never feeds power back into the grid. This scenario is highly desirable to automotive manufacturers, who harbor great concerns about battery warranty if vehicle-to-grid discharging is allowed. The second strategy, V2GFull, varies not only the charging of the vehicle battery, but also can vary the discharging of the battery back into the power grid. This scenario is currently less desirable to automotive manufacturers, but provides an additional resource benefit to PHEV/BEVs in meeting the additional imbalance imposed by wind. Key findings in the report relate to the PHEV/BEV population required to meet the additional imbalance when comparing V2GHalf to V2GFull populations, and when comparing home-only-charging and work-and-home-charging scenarios. Utilizing V2GFull strategies over V2GHalf resulted in a nearly 33% reduction in the number of vehicles required. This reduction indicates fewer vehicles are needed to meet the unhandled energy, but they would utilize discharging of the vehicle battery into the grid. This practice currently results in the voiding of automotive manufacturer's battery warranty, and is not feasible for many customers. The second key finding is the change in the required population when PHEV/BEV charging is available at both home and work. Allowing 10% of the vehicle population access to work charging resulted in nearly 80% of the grid benefit. Home-only charging requires, at best, 94% of the current NWPP light duty vehicle fleet to be a PHEV or BEV. With the introduction of full work charging availability, only 8% of the NWPP light duty vehicle fleet is required. Work charging has primarily been associated with mitigating range anxiety in new electric vehicle owners, but these studies indicate they have significant potential for improving grid reliability. The V2GHalf and V2GFull charging strategies of the report utilize grid frequency as an indication of the imbalance requirements. The introduction of public charging stations, as well as the potential for PHEV/BEVs to be used as a resource for renewable generation integration, creates conditions for additional products into the ancillary services market. In the United Kingdom, such a capability would be bid as a frequency product in the ancillary services market. Such a market could create the need for larger, third-party aggregators or services to manage the use of electric vehicles as a grid resource. Ultimately, customer adoption, usage patterns and habits, and feedback from the power and automotive industries will drive the need.

17 WIND ENERGY↗

Review of Test Procedure for Determining HSPFs of Residential Variable-Speed Heat Pumps

This report reviews the suitability of the existing Heating Seasonal Performance Factor (HSPF) ratings and testing requirements for the current generation of variable-speed (VS) air-source heat pumps. Recent field test results indicate larger discrepancies between rated HSPF and field-observed HSPF for VS models than for single-speed models in the same houses. These findings suggest that the heating season test and ratings procedure should be revisited for VS heat pumps. The ratings and testing procedures are described in ANSI/AHRI 210/240 (2008) for single-speed, two-capacity, and variable-speed units. Analysis of manufacturer and independent test performance data on VS units reveals why the current VS testing/ratings procedure results in overly optimistic HSPF ratings for some VS units relative to other types of heat pumps. This is due to a combination of extrapolation of low speed test data beyond the originally anticipated ambient temperature operating range and the constraints of unit controls, which prevent low speed operation over the range of ambient temperatures assumed in the procedure for low speed. As a result, the HSPFs of such units are being overpredicted relative to those for single- and two-capacity designs. This overprediction has been found to be significantly reduced by use in the HSPF ratings procedure of an alternative higher-load heating load line, described in a companion report (Rice et al., 2015).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dosimetric Changes Resulting From Patient Rotational Setup Errors in Proton Therapy Prostate Plans

Purpose: To evaluate the dose changes to the target and critical structures from rotational setup errors in prostate cancer patients treated with proton therapy. Methods and Materials: A total of 70 plans were analyzed for 10 patients treated with parallel-opposed proton beams to a dose of 7,600 {sup 60}Co-cGy-equivalent (CcGE) in 200 CcGE fractions to the clinical target volume (i.e., prostate and proximal seminal vesicles). Rotational setup errors of +3{sup o}, -3 deg., +5 deg., and -5 deg. (to simulate pelvic tilt) were generated by adjusting the gantry. Horizontal couch shifts of +3 deg. and -3 deg. (to simulate longitudinal setup variability) were also generated. Verification plans were recomputed, keeping the same treatment parameters as the control. Results: All changes shown are for 38 fractions. The mean clinical target volume dose was 7,780 CcGE. The mean change in the clinical target volume dose in the worse case scenario for all shifts was 2 CcGE (absolute range in worst case scenario, 7,729-7,848 CcGE). The mean changes in the critical organ dose in the worst case scenario was 6 CcGE (bladder), 18 CcGE (rectum), 36 CcGE (anterior rectal wall), and 141 CcGE (femoral heads) for all plans. In general, the percentage of change in the worse case scenario for all shifts to the critical structures was <5%. Deviations in the absolute percentage of volume of organ receiving 45 and 70 Gy for the bladder and rectum were <2% for all plans. Conclusion: Patient rotational movements of 3 deg. and 5 deg. and horizontal couch shifts of 3 deg. in prostate proton planning did not confer clinically significant dose changes to the target volumes or critical structures00.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Entropy removal of medical diagnostics

Shannon entropy is a core concept in machine learning and information theory, particularly in decision tree modeling. To date, no studies have extensively and quantitatively applied Shannon entropy in a systematic way to quantify the entropy of clinical situations using diagnostic variables (true and false positives and negatives, respectively). Decision tree representations of medical decision-making tools can be generated using diagnostic variables found in literature and entropy removal can be calculated for these tools. This concept of clinical entropy removal has significant potential for further use to bring forth healthcare innovation, such as quantifying the impact of clinical guidelines and value of care and applications to Emergency Medicine scenarios where diagnostic accuracy in a limited time window is paramount. This analysis was done for 623 diagnostic tools and provided unique insights into their utility. For studies that provided detailed data on medical decision-making algorithms, bootstrapped datasets were generated from source data to perform comprehensive machine learning analysis on these algorithms and their constituent steps, which revealed a novel and thorough evaluation of medical diagnostic algorithms.

97 MATHEMATICS AND COMPUTING↗

Development of the Second-Generation Oscillating Surge Wave Energy Converter with Variable Geometry

This study investigates the effect of design changes on the hydrodynamics of a novel oscillating surge wave energy converter being developed at the National Renewable Energy Laboratory. The design utilizes controllable geometry features to shed structural loads while maintaining a rated power over a greater number of sea states. The second-generation design will seek to provide a more refined control of performance because the first-generation design demonstrated performance reductions considered too large for smooth power output. Performance is evaluated using frequency domain analysis with consideration of a nonideal power-take-off system, with respect to power absorption, foundation loads, and power-take-off torque.

16 TIDAL AND WAVE POWER↗