Search NASA⌕ Search

SEARCH · Search NASA

Results for “3D Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

SU-E-J-237: Real-Time 3D Anatomy Estimation From Undersampled MR Acquisitions

Recent developments made MRI guided radiotherapy feasible. Performing simultaneous imaging during fractions can provide information about changing anatomy by means of deformable image registration for either immediate plan adaptations or accurate dose accumulation on the changing anatomy. In 3D MRI, however, acquisition time is considerable and scales with resolution. Furthermore, intra-scan motion degrades image quality.In this work, we investigate the sensitivity of registration quality on imageresolution: potentially, by employing spatial undersampling, the acquisition timeof MR images for the purpose of deformable image registration can be reducedsignificantly.On a volunteer, 3D-MR imaging data was sampled in a navigator-gated manner, acquiring one axial volume (360×260×100mm{sup 3}) per 3s during exhale phase. A T1-weighted FFE sequence was used with an acquired voxel size of (2.5mm{sup 3}) for a duration of 17min. Deformation vector fields were evaluated for 100 imaging cycles with respect to the initial anatomy using deformable image registration based on optical flow. Subsequently, the imaging data was downsampled by a factor of 2, simulating a fourfold acquisition speed. Displacements of the downsampled volumes were then calculated by the same process.In kidneyliver boundaries and the region around stomach/duodenum, prominent organ drifts could be observed in both the original and the downsampled imaging data. An increasing displacement of approximately 2mm was observed for the kidney, while an area around the stomach showed sudden displacements of 4mm. Comparison of the motile points over time showed high reproducibility between the displacements of high-resolution and downsampled volumes: over a 17min acquisition, the componentwise RMS error was not more than 0.38mm.Based on the synthetic experiments, 3D nonrigid image registration shows little sensitivity to image resolution and the displacement information is preserved even when halving the resolution. This can be employed to greatly reduce image acquisition times for interventional applications in real-time. This work was funded by the SoRTS consortium, which includes the industry partners Elekta, Philips and Technolution.

60 APPLIED LIFE SCIENCES↗

The simulation of 3D microcalcification clusters in 2D digital mammography and breast tomosynthesis

Purpose: This work proposes a new method of building 3D models of microcalcification clusters and describes the validation of their realistic appearance when simulated into 2D digital mammograms and into breast tomosynthesis images. Methods: A micro-CT unit was used to scan 23 breast biopsy specimens of microcalcification clusters with malignant and benign characteristics and their 3D reconstructed datasets were segmented to obtain 3D models of microcalcification clusters. These models were then adjusted for the x-ray spectrum used and for the system resolution and simulated into 2D projection images to obtain mammograms after image processing and into tomographic sequences of projection images, which were then reconstructed to form 3D tomosynthesis datasets. Six radiologists were asked to distinguish between 40 real and 40 simulated clusters of microcalcifications in two separate studies on 2D mammography and tomosynthesis datasets. Receiver operating characteristic (ROC) analysis was used to test the ability of each observer to distinguish between simulated and real microcalcification clusters. The kappa statistic was applied to assess how often the individual simulated and real microcalcification clusters had received similar scores (''agreement'') on their realistic appearance in both modalities. This analysis was performed for all readers and for the real and the simulated group of microcalcification clusters separately. ''Poor'' agreement would reflect radiologists' confusion between simulated and real clusters, i.e., lesions not systematically evaluated in both modalities as either simulated or real, and would therefore be interpreted as a success of the present models. Results: The area under the ROC curve, averaged over the observers, was 0.55 (95% confidence interval [0.44, 0.66]) for the 2D study, and 0.46 (95% confidence interval [0.29, 0.64]) for the tomosynthesis study, indicating no statistically significant difference between real and simulated lesions (p > 0.05). Agreement between allocated lesion scores for 2D mammography and those for the tomosynthesis series was poor. Conclusions: The realistic appearance of the 3D models of microcalcification clusters, whether malignant or benign clusters, was confirmed for 2D digital mammography images and the breast tomosynthesis datasets; this database of clusters is suitable for use in future observer performance studies related to the detectability of microcalcification clusters. Such studies include comparing 2D digital mammography to breast tomosynthesis and comparing different reconstruction algorithms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Flexible drift-compensation system for precise 3D force mapping in severe drift environments

The acquisition of dense 3D data sets is of great importance, but also a challenge for scanning probe microscopy (SPM). Thermal drift often induces severe distortions in the data, which usually constrains the acquisition of dense data sets to experiments under ultra-high vacuum and low-temperature conditions. Atom tracking is an elegant approach to compensate for thermal drift and to position the microscope tip with highest precision. Here, we present a flexible drift compensation system which can easily be connected to existing SPM hardware. Furthermore, we describe a 3D data acquisition and position correction protocol, which is capable of handling large and non-linear drift as typically present in room temperature measurements. This protocol is based on atom-tracking for precise positioning of the tip and we are able to acquire dense 3D data sets over several hours at room temperature. The performance of the protocol is demonstrated by presenting 3D data taken on a CaCO{sub 3}(1014) surface with the data density being as large as 85x85x500 pixel.

36 MATERIALS SCIENCE↗

Differences in Effective Target Volume Between Various Techniques of Accelerated Partial Breast Irradiation

Purpose: Different cavity expansions are used to define the clinical target volume (CTV) for accelerated partial breast irradiation (APBI) delivered via balloon brachytherapy (1 cm) vs. three-dimensional conformal radiotherapy (3D-CRT) (1.5 cm). Previous studies have argued that the CTVs generated by these different margins are effectively equivalent. In this study, we use deformable registration to assess the effective CTV treated by balloon brachytherapy on clinically representative 3D-CRT planning images. Methods and Materials: Ten patients previously treated with the MammoSite were studied. Each patient had two computed tomography (CT) scans, one acquired before and one after balloon implantation. In-house deformable registration software was used to deform the MammoSite CTV onto the balloonless CT set. The deformed CTV was validated using anatomical landmarks common to both CT scans. Results: The effective CTV treated by the MammoSite was on average 7% {+-} 10% larger and 38% {+-} 4% smaller than 3D-CRT CTVs created using uniform expansions of 1 and 1.5 cm, respectively. The average effective CTV margin was 1.0 cm, the same as the actual MammoSite CTV margin. However, the effective CTV margin was nonuniform and could range from 5 to 15 mm in any given direction. Effective margins <1 cm were attributable to poor cavity-balloon conformance. Balloon size relative to the cavity did not significantly correlate with the effective margin. Conclusion: In this study, the 1.0-cm MammoSite CTV margin treated an effective volume that was significantly smaller than the 3D-CRT CTV based on a 1.5-cm margin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantitative three-dimensional characterization of block copolymer directed self-assembly on combined chemical and topographical prepatterned templates

Characterization of the three-dimensional (3D) structure in directed self-assembly (DSA) of block copolymers is crucial for understanding the complex relationships between the guiding template and the resulting polymer structure so DSA could be successfully implemented for advanced lithography applications. Here, we combined scanning transmission electron microscopy (STEM) tomography and coarse-grain simulations to probe the 3D structure of P2VP- b -PS- b -P2VP assembled on prepatterned templates using solvent vapor annealing. The templates consisted of nonpreferential background and raised guiding stripes that had PS-preferential top surfaces and P2VP-preferential sidewalls. The full 3D characterization allowed us to quantify the shape of the polymer domains and the interface between domains as a function of depth in the film and template geometry and offered important insights that were not accessible with 2D metrology. Sidewall guiding was advantageous in promoting the alignment and lowering the roughness of the P2VP domains over the sidewalls, but incommensurate confinement from the increased topography could cause roughness and intermittent dislocations in domains over the background region at the bottom of the film. The 3D characterization of bridge structures between domains over the background and breaks within domains on guiding lines sheds light on possible origins of common DSA defects. The positional fluctuations of the PS/P2VP interface between domains showed a depth-dependent behavior, with high levels of fluctuations near both the free surface of the film and the substrate and lower fluctuation levels in the middle of the film. As a result, this research demonstrates how 3D characterization offers a better understanding of DSA processes, leading to better design and fabrication of directing templates.

36 MATERIALS SCIENCE↗

Synchrotron micro-computed tomography analysis of neutron-irradiated U-Mo fuel

The three-dimensional (3D) microstructure of neutron-irradiated uranium-10 wt.% molybdenum (U-10Mo) fuel with a burn-up of 9.8 × 10 21 fissions/cm 3 was characterized using a novel, multi-modal synchrotron micro-computed tomography approach combining propagation-based phase-contrast enhanced and absorption contrast techniques. The porosity development, porosity interconnectedness, swelling, composition, local thickness of the zirconium (Zr) diffusion barrier, and the influence of the fuel–cladding interaction on the local composition and pore morphology, were uniquely determined in 3D. Two cuboids were produced using a focused ion beam-scanning electron microscope at the Zr diffusion barrier–fuel interface and in the bulk fuel. The bulk fuel sample swelled by 53.3 [+9.7/−3.1]%, while the fuel near the Zr–fuel interface swelled by 63.3 [+14.7/−7.2]%. The average local thickness of the Zr diffusion barrier decreased by 53 %, compared to the expected pre-irradiated thickness. Four pore morphology regions were identified initiating parallel to the fuel–Zr interaction region: (1) an interaction layer of suppressed porosity, (2) a layer of elongated and interconnected porosity, (3) a transition zone of low porosity, and (4) a layer of unoriented porosity representative of the bulk fuel behavior. The increase in porosity near the diffusion barrier corresponded to a higher U concentration compared to that in the bulk fuel. The interconnected porosity in the fuel near the diffusion barrier was extensive and oriented parallel to the diffusion barrier, while the bulk fuel had more compact and isolated pore networks. The interaction layer, despite having suppressed porosity, was nearly 100 wt.% U. Porosity suppression at the diffusion barrier corresponds to the expected reduction in radiation-driven diffusion of Xe at the interface despite the anticipated increase in fission product nucleation originating from a higher U concentration. In conclusion, the novel 3D insights of the porosity, swelling, and compositional variations characterized herein can improve the fidelity of fuel performance codes for proliferation-resistant fuels for research and test reactors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An Evaluation of Two Internal Surrogates for Determining the Three-Dimensional Position of Peripheral Lung Tumors

Purpose: Both carina and diaphragm positions have been used as surrogates during respiratory-gated radiotherapy. We studied the correlation of both surrogates with three-dimensional (3D) tumor position. Methods and Materials: A total of 59 repeat artifact-free four-dimensional (4D) computed tomography (CT) scans, acquired during uncoached breathing, were identified in 23 patients with Stage I lung cancer. Repeat scans were co-registered to the initial 4D CT scan, and tumor, carina, and ipsilateral diaphragm were manually contoured in all phases of each 4D CT data set. Correlation between positions of carina and diaphragm with 3D tumor position was studied by use of log-likelihood ratio statistics. Models to predict 3D tumor position from internal surrogates at end inspiration (EI) and end expiration (EE) were developed, and model accuracy was tested by calculating SDs of differences between predicted and actual tumor positions. Results: Motion of both the carina and diaphragm significantly correlated with tumor motion, but log-likelihood ratios indicated that the carina was more predictive for tumor position. When craniocaudal tumor position was predicted by use of craniocaudal carina positions, the SDs of the differences between the predicted and observed positions were 2.2 mm and 2.4 mm at EI and EE, respectively. The corresponding SDs derived with the diaphragm positions were 3.7 mm and 3.9 mm at EI and EE, respectively. Prediction errors in the other directions were comparable. Prediction accuracy was similar at EI and EE. Conclusions: The carina is a better surrogate of 3D tumor position than diaphragm position. Because residual prediction errors were observed in this analysis, additional studies will be performed using audio-coached scans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Enthalpy Testing to Validate Simulation of an Aerosol Capture Probe

AERACEPT (Aerosol Rapid Analysis Combined Entry Probe/sonde Technology) is a developing technology enabling in-situ aerosol particle sampling and analysis in a small spacecraft mission envelope. It integrates a passive aerosol sample collection system into a probe’s thermal protection system (TPS) to remove the need for heat shield separation and active descent control (parachutes, gliders, etc.). AERACEPT is being validated against the requirements of the Nephele mission concept, which targets the middle and lower Venus cloud layers. The proposed technology employs 3D Carbon-Carbon (3D-CC) at the probe’s nose to withstand the extreme environments encountered in a Venus entry without producing pyrolysis gases that would contaminate the mission sample collection. Any shape change of this 3D-CC sample inlet will affect airflow through the sampling system, thereby impacting aerosol sample collection bias and efficiency. Accurate prediction of the nose’s material response during entry is there-fore of fundamental importance to the development and practical use of this technology. As a result, the AERACEPT project is planning a test campaign in the newly built PlasmatronX facility with a novel “Open Iso-Q” test article to validate state-of-the-art material response tools for a simulated Venus entry. The PlasmatronX is a 350 kW inductively-coupled plasma facility developed and run by the Center for Hypersonics and Entry Systems Studies at the University of Illinois at Urbana-Champaign. The facility can support ground testing for a variety of planetary destinations by simulating entry conditions in Nitrogen, Air, and Carbon Dioxide. To best simulate the Venus atmosphere and match flight-like recession, the planned AERACEPT test campaign will use Carbon Dioxide as its test gas. AERACEPT has designed two test articles for this campaign: 1) a standard test article whose curved surface approximates a constant applied heat flux (“Closed Iso-Q” model) and 2) a novel inlet test article with a through-hole at the stagnation point (“Open Iso-Q” model). Both article types consist of a 3D-CC sample bonded to a graphite fixture. All articles will be laser scanned before and after testing to estimate shape change and recession, and the “Closed Iso-Q” articles will be instrumented with thermocouples to provide temperature histories. The test article temperatures and inlet shape change will be compared against simulations run with the Porous material Analysis Toolbox based on OpenFOAM (PATO) to validate the AERACEPT 3D-CC material response model. Due to the high thermal conductivity of 3D-CC, multidimensional effects have a large influence on the test article temperature and the standard 1-D material response tools are not sufficient for test planning. The test campaign features (e.g. article design, run duration, heat fluxes) are therefore informed by a series of 3-D simulations using state-of-the-art material response tools such as PATO. The test campaign is scheduled for spring of 2024. Expected results include 1) Key drivers of selected test conditions (e.g. matching mission flight atmosphere & recession), 2) Simulation results that informed test article design, 3) Acquired test data such as recession measurements, temperature histories, and photos, and 4) Comparisons between test results and simulation predictions.

AERACEPT↗

High-Enthalpy Testing to Validate Simulation of an Aerosol Capture Probe

AERACEPT (Aerosol Rapid Analysis Combined Entry Probe/sonde Technology) is a developing technology enabling in-situ aerosol particle sampling and analysis in a small spacecraft mission envelope. It integrates a passive aerosol sample collection system into a probe’s thermal protection system (TPS) to remove the need for heat shield separation and active descent control (parachutes, gliders, etc.). AERACEPT is being validated against the requirements of the Nephele mission concept, which targets the middle and lower Venus cloud layers. The proposed technology employs 3D Carbon-Carbon (3D-CC) at the probe’s nose to withstand the extreme environments encountered in a Venus entry without producing pyrolysis gases that would contaminate the mission sample collection. Any shape change of this 3D-CC sample inlet will affect airflow through the sampling system, thereby impacting aerosol sample collection bias and efficiency. Accurate prediction of the nose’s material response during entry is there-fore of fundamental importance to the development and practical use of this technology. As a result, the AERACEPT project is planning a test campaign in the newly built PlasmatronX facility with a novel “Open Iso-Q” test article to validate state-of-the-art material response tools for a simulated Venus entry. The PlasmatronX is a 350 kW inductively-coupled plasma facility developed and run by the Center for Hypersonics and Entry Systems Studies at the University of Illinois at Urbana-Champaign. The facility can support ground testing for a variety of planetary destinations by simulating entry conditions in Nitrogen, Air, and Carbon Dioxide. To best simulate the Venus atmosphere and match flight-like recession, the planned AERACEPT test campaign will use Carbon Dioxide as its test gas. AERACEPT has designed two test articles for this campaign: 1) a standard test article whose curved surface approximates a constant applied heat flux (“Closed Iso-Q” model) and 2) a novel inlet test article with a through-hole at the stagnation point (“Open Iso-Q” model). Both article types consist of a 3D-CC sample bonded to a graphite fixture. All articles will be laser scanned before and after testing to estimate shape change and recession, and the “Closed Iso-Q” articles will be instrumented with thermocouples to provide temperature histories. The test article temperatures and inlet shape change will be compared against simulations run with the Porous material Analysis Toolbox based on OpenFOAM (PATO) to validate the AERACEPT 3D-CC material response model. Due to the high thermal conductivity of 3D-CC, multidimensional effects have a large influence on the test article temperature and the standard 1-D material response tools are not sufficient for test planning. The test campaign features (e.g. article design, run duration, heat fluxes) are therefore informed by a series of 3-D simulations using state-of-the-art material response tools such as PATO. The test campaign is scheduled for spring of 2024. Expected results include 1) Key drivers of selected test conditions (e.g. matching mission flight atmosphere & recession), 2) Simulation results that informed test article design, 3) Acquired test data such as recession measurements, temperature histories, and photos, and 4) Comparisons between test results and simulation predictions.

AERACEPT↗

Few-view computed tomography reconstruction using deep neural network inference

A system for generating 2D slices of a 3D image of a target volume is provided. The system receives a target sinogram collected during a computed tomography scan of the target volume. The system inputs the target sinogram to a convolutional neural network (CNN) to generate predicted 2D slices of the 3D image. The CNN is trained using training 2D slices of training 3D images. The system initializes 2D slices to the predicted 2D slices. The system reconstructs 2D slices of the 3D image from the target sinogram and the initialized 2D slices.

Kim, Hyojin↗

An integrated two-dimensional modeling method for predicting ductility of thin-walled die cast magnesium

In this paper, a two-dimensional (2D) microstructure-based modeling method is developed in order to predict the ductility of a thin-walled high pressure die cast magnesium (Mg) by considering the three-dimensional (3D) thru-thickness pore distributions. For this purpose, a series of 3D synthetic microstructure-based finite element models and the corresponding 2D models are first generated with various pore volume fractions, pore size distributions and pore shapes. The input material properties for the 2D models are determined based on the 3D cubic model with a spherical pore and the generalized Neuber’s rule. Based on the resulting ductility of the 3D and 2D models, a 3D/2D ductility correlation curve is developed as a function of the characteristics/shape of the input fracture strain curve used in the 3D model. The validity of the ductility correlation curve is examined with casting samples with actual microstructures. Here, the results show that the suggested 2D modeling methodology can be used together with the ductility correlation curve in predicting the ductility of thin-walled Mg castings.

36 MATERIALS SCIENCE↗

Thresholding Analysis and Feature Extraction from 3D Ground Penetrating Radar Data for Noninvasive Assessment of Peanut Yield

This study explores the efficacy of utilizing a novel ground penetrating radar (GPR) acquisition platform and data analysis methods to quantify peanut yield for breeding selection, agronomic research, and producer management and harvest applications. Sixty plots comprising different peanut market types were scanned with a multichannel, air-launched GPR antenna. Image thresholding analysis was performed on 3D GPR data from four of the channels to extract features that were correlated to peanut yield with the objective of developing a noninvasive high-throughput peanut phenotyping and yield-monitoring methodology. Plot-level GPR data were summarized using mean, standard deviation, sum, and the number of nonzero values (counts) below or above different percentile threshold values. Best results were obtained for data below the percentile threshold for mean, standard deviation and sum. Data both below and above the percentile threshold generated good correlations for count. Correlating individual GPR features to yield generated correlations of up to 39% explained variability, while combining GPR features in multiple linear regression models generated up to 51% explained variability. The correlations increased when regression models were developed separately for each peanut type. This research demonstrates that a systematic search of thresholding range, analysis window size, and data summary statistics is necessary for successful application of this type of analysis. The results also establish that thresholding analysis of GPR data is an appropriate methodology for noninvasive assessment of peanut yield, which could be further developed for high-throughput phenotyping and yield-monitoring, adding a new sensor and new capabilities to the growing set of digital agriculture technologies.

54 ENVIRONMENTAL SCIENCES↗

A dual-view digital tomosynthesis imaging technique for improved chest imaging

Purpose: Digital tomosynthesis (DTS) has been shown to be useful for reducing the overlapping of abnormalities with anatomical structures at various depth levels along the posterior–anterior (PA) direction in chest radiography. However, DTS provides crude three-dimensional (3D) images that have poor resolution in the lateral view and can only be displayed with reasonable quality in the PA view. Furthermore, the spillover of high-contrast objects from off-fulcrum planes generates artifacts that may impede the diagnostic use of the DTS images. In this paper, the authors describe and demonstrate the use of a dual-view DTS technique to improve the accuracy of the reconstructed volume image data for more accurate rendition of the anatomy and slice images with improved resolution and reduced artifacts, thus allowing the 3D image data to be viewed in views other than the PA view. Methods: With the dual-view DTS technique, limited angle scans are performed and projection images are acquired in two orthogonal views: PA and lateral. The dual-view projection data are used together to reconstruct 3D images using the maximum likelihood expectation maximization iterative algorithm. In this study, projection images were simulated or experimentally acquired over 360° using the scanning geometry for cone beam computed tomography (CBCT). While all projections were used to reconstruct CBCT images, selected projections were extracted and used to reconstruct single- and dual-view DTS images for comparison with the CBCT images. For realistic demonstration and comparison, a digital chest phantom derived from clinical CT images was used for the simulation study. An anthropomorphic chest phantom was imaged for the experimental study. The resultant dual-view DTS images were visually compared with the single-view DTS images and CBCT images for the presence of image artifacts and accuracy of CT numbers and anatomy and quantitatively compared with root-mean-square-deviation (RMSD) values computed using the digital chest phantom or the CBCT images as the reference in the simulation and experimental study, respectively. High-contrast wires with vertical, oblique, and horizontal orientations in a PA view plane were also imaged to investigate the spatial resolutions and how the wire signals spread in the PA view and lateral view slice images. Results: Both the digital phantom images (simulated) and the anthropomorphic phantom images (experimentally generated) demonstrated that the dual-view DTS technique resulted in improved spatial resolution in the depth (PA) direction, more accurate representation of the anatomy, and significantly reduced artifacts. The RMSD values corroborate well with visual observations with substantially lower RMSD values measured for the dual-view DTS images as compared to those measured for the single-view DTS images. The imaging experiment with the high-contrast wires shows that while the vertical and oblique wires could be resolved in the lateral view in both single- and dual-view DTS images, the horizontal wire could only be resolved in the dual-view DTS images. This indicates that with single-view DTS, the wire signals spread liberally to off-fulcrum planes and generated wire shadow there. Conclusions: The authors have demonstrated both visually and quantitatively that the dual-view DTS technique can be used to achieve more accurate rendition of the anatomy and to obtain slice images with improved resolution and reduced artifacts as compared to the single-view DTS technique, thus allowing the 3D image data to be viewed in views other than the PA view. These advantages could make the dual-view DTS technique useful in situations where better separation of the objects-of-interest from the off-fulcrum structures or more accurate 3D rendition of the anatomy are required while a regular CT examination is undesirable due to radiation dose considerations.

60 APPLIED LIFE SCIENCES↗

Dynamic compressed sensing for real-time tomographic reconstruction

Electron tomography has achieved higher resolution and quality at reduced doses with recent advances in compressed sensing. Compressed sensing (CS) exploits the inherent sparse signal structure to efficiently reconstruct three-dimensional (3D) volumes at the nanoscale from undersampled measurements. However, the process bottlenecks 3D reconstruction with computation times that run from hours to days. Here we demonstrate a framework for dynamic compressed sensing that produces a 3D specimen structure that updates in real-time as new specimen projections are collected. Researchers can begin interpreting 3D specimens as data is collected to facilitate high-throughput and interactive analysis. Using scanning transmission electron microscopy (STEM), we show that dynamic compressed sensing accelerates the convergence speed by ~3-fold while also reducing its error by 27% for a Au/SrTiO 3 nanoparticle specimen. Before a tomography experiment is completed, the 3D tomogram has interpretable structure within ~33% of completion and fine details are visible as early as ~66%. Upon completion of an experiment, a high-fidelity 3D visualization is produced without further delay. Additionally, we report reconstruction parameters that tune data fidelity can be manipulated throughout the computation without re-running the entire process.

47 OTHER INSTRUMENTATION↗

3-D MAPPING TECHNOLOGIES FOR HIGH LEVEL WASTE TANKS

This research investigated four techniques that could be applicable for mapping of solids remaining in radioactive waste tanks at the Savannah River Site: stereo vision, LIDAR, flash LIDAR, and Structure from Motion (SfM). Stereo vision is the least appropriate technique for the solids mapping application. Although the equipment cost is low and repackaging would be fairly simple, the algorithms to create a 3D image from stereo vision would require significant further development and may not even be applicable since stereo vision works by finding disparity in feature point locations from the images taken by the cameras. When minimal variation in visual texture exists for an area of interest, it becomes difficult for the software to detect correspondences for that object. SfM appears to be appropriate for solids mapping in waste tanks. However, equipment development would be required for positioning and movement of the camera in the tank space to enable capturing a sequence of images of the scene. Since SfM requires the identification of distinctive features and associates those features to their corresponding instantiations in the other image frames, mockup testing would be required to determine the applicability of SfM technology for mapping of waste in tanks. There may be too few features to track between image frame sequences to employ the SfM technology since uniform appearance may exist when viewing the remaining solids in the interior of the waste tanks. Although scanning LIDAR appears to be an adequate solution, the expense of the equipment ($80,000-$120,000) and the need for further development to allow tank deployment may prohibit utilizing this technology. The development would include repackaging of equipment to permit deployment through the 4-inch access ports and to keep the equipment relatively uncontaminated to allow use in additional tanks. 3D flash LIDAR has a number of advantages over stereo vision, scanning LIDAR, and SfM, including full frame time-of-flight data (3D image) collected with a single laser pulse, high frame rates, direct calculation of range, blur-free images without motion distortion, no need for precision scanning mechanisms, ability to combine 3D flash LIDAR with 2D cameras for 2D texture over 3D depth, and no moving parts. The major disadvantage of the 3D flash LIDAR camera is the cost of approximately $150,000, not including the software development time and repackaging of the camera for deployment in the waste tanks.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-J-55: End-To-End Effectiveness Analysis of 3D Surface Image Guided Voluntary Breath-Holding Radiotherapy for Left Breast

Purpose To evaluate the effectiveness of using 3D-surface-image to guide breath-holding (BH) left-side breast treatment. Methods Two 3D surface image guided BH procedures were implemented and evaluated: normal-BH, taking BH at a comfortable level, and deep-inspiration-breath-holding (DIBH). A total of 20 patients (10 Normal-BH and 10 DIBH) were recruited. Patients received a BH evaluation using a commercialized 3D-surface- tracking-system (VisionRT, London, UK) to quantify the reproducibility of BH positions prior to CT scan. Tangential 3D/IMRT plans were conducted. Patients were initially setup under free-breathing (FB) condition using the FB surface obtained from the untaged CT to ensure a correct patient position. Patients were then guided to reach the planned BH position using the BH surface obtained from the BH CT. Action-levels were set at each phase of treatment process based on the information provided by the 3D-surface-tracking-system for proper interventions (eliminate/re-setup/ re-coaching). We reviewed the frequency of interventions to evaluate its effectiveness. The FB-CBCT and port-film were utilized to evaluate the accuracy of 3D-surface-guided setups. Results 25% of BH candidates with BH positioning uncertainty > 2mm are eliminated prior to CT scan. For >90% of fractions, based on the setup deltas from3D-surface-trackingsystem, adjustments of patient setup are needed after the initial-setup using laser. 3D-surface-guided-setup accuracy is comparable as CBCT. For the BH guidance, frequency of interventions (a re-coaching/re-setup) is 40%(Normal-BH)/91%(DIBH) of treatments for the first 5-fractions and then drops to 16%(Normal-BH)/46%(DIBH). The necessity of re-setup is highly patient-specific for Normal-BH but highly random among patients for DIBH. Overall, a −0.8±2.4 mm accuracy of the anterior pericardial shadow position was achieved. Conclusion 3D-surface-image technology provides effective intervention to the treatment process and ensures favorable day-to-day setup accuracy. DIBH setup appears to be more uncertain and this would be the patient group who will definitely benefit from the extra information of 3D surface setup.

60 APPLIED LIFE SCIENCES↗

Design and performance of a combined secondary ion mass spectrometry-scanning probe microscopy instrument for high sensitivity and high-resolution elemental three-dimensional analysis

State-of-the-art secondary ion mass spectrometry (SIMS) instruments allow producing 3D chemical mappings with excellent sensitivity and spatial resolution. Several important artifacts however arise from the fact that SIMS 3D mapping does not take into account the surface topography of the sample. In order to correct these artifacts, we have integrated a specially developed scanning probe microscopy (SPM) system into a commercial Cameca NanoSIMS 50 instrument. This new SPM module, which was designed as a DN200CF flange-mounted bolt-on accessory, includes a new high-precision sample stage, a scanner with a range of 100 {mu}m in x and y direction, and a dedicated SPM head which can be operated in the atomic force microscopy (AFM) and Kelvin probe force microscopy modes. Topographical information gained from AFM measurements taken before, during, and after SIMS analysis as well as the SIMS data are automatically compiled into an accurate 3D reconstruction using the software program 'SARINA,' which was developed for this first combined SIMS-SPM instrument. The achievable lateral resolutions are 6 nm in the SPM mode and 45 nm in the SIMS mode. Elemental 3D images obtained with our integrated SIMS-SPM instrument on Al/Cu and polystyrene/poly(methyl methacrylate) samples demonstrate the advantages of the combined SIMS-SPM approach.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗