Search NASA⌕ Search

SEARCH · Search NASA

Results for “Advanced Signal Processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Ionospheric Specifications for SAR Interferometry (ISSI)

The ISSI software package is designed to image the ionosphere from space by calibrating and processing polarimetric synthetic aperture radar (PolSAR) data collected from low Earth orbit satellites. Signals transmitted and received by a PolSAR are subject to the Faraday rotation effect as they traverse the magnetized ionosphere. The ISSI algorithms combine the horizontally and vertically polarized (with respect to the radar system) SAR signals to estimate Faraday rotation and ionospheric total electron content (TEC) with spatial resolutions of sub-kilometers to kilometers, and to derive radar system calibration parameters. The ISSI software package has been designed and developed to integrate the algorithms, process PolSAR data, and image as well as visualize the ionospheric measurements. A number of tests have been conducted using ISSI with PolSAR data collected from various latitude regions using the phase array-type L-band synthetic aperture radar (PALSAR) onboard Japan Aerospace Exploration Agency's Advanced Land Observing Satellite mission, and also with Global Positioning System data. These tests have demonstrated and validated SAR-derived ionospheric images and data correction algorithms.

Pi, Xiaoqing↗

Exhibition of Stochastic Resonance in Vestibular Perception

Astronauts experience sensorimotor changes during spaceflight, particularly during G-transitions. Post flight sensorimotor changes include spatial disorientation, along with postural and gait instability that may degrade operational capabilities of the astronauts and endanger the crew. A sensorimotor countermeasure that mitigates these effects would improve crewmember safety and decrease risk. The goal of this research is to investigate the potential use of stochastic vestibular stimulation (SVS) as a technology to improve sensorimotor function. We hypothesize that low levels of SVS will improve sensorimotor perception through the phenomenon of stochastic resonance (SR), when the response of a nonlinear system to a weak input signal is enhanced by the application of a particular nonzero level of noise. This study aims to advance the development of SVS as a potential countermeasure by 1) demonstrating the exhibition of stochastic resonance in vestibular perception, a vital component of sensorimotor function, 2) investigating the repeatability of SR exhibition, and 3) determining the relative contribution of the semicircular canals (SCC) and otolith (OTO) organs to vestibular perceptual SR. A constant current stimulator was used to deliver bilateral bipolar SVS via electrodes placed on each of the mastoid processes, as previously done. Vestibular perceptual motion recognition thresholds were measured using a 6-degree of freedom MOOG platform and a 150 trial 3-down/1-up staircase procedure. In the first test session, we measured vestibular perceptual thresholds in upright roll-tilt at 0.2 Hz (SCC+OTO) with SVS ranging from 0-700 μA. In a second test session a week later, we re-measured roll-tilt thresholds with 0, optimal (from test session 1), and 1500 μA SVS levels. A subset of these subjects, plus naive subjects, participated in two additional test sessions in which we measured thresholds in supine roll-rotation at 0.2 Hz (SCC) and upright y-translation at 1 Hz (OTO) with SVS up to 700 μA. A sinusoidal galvanic vestibular stimulation (GVS) perceptual threshold was also measured on each test day and used to normalize the SVS levels across subjects. In roll-tilt thresholds with SVS, the characteristic SR curve was qualitatively exhibited in 10 of 12 subjects, and the improvement in motion threshold was significant in 6 subjects, indicating that optimal SVS improved passive body motion perception in a way that is consistent with classical SR theory. A probabilistic comparison to numeric simulations further validated these experimental results. On the second test session, 4 out of the 10 SR exhibitors showed repeated improvement with SVS compared to the no SVS condition. Data collection is ongoing for the last two test sessions in which SCC and OTO only perceptual motion recognition thresholds are being measured with SVS. The final results of these test sessions will give insight into whether vestibular perceptual SR can occur when only one type of vestibular sensor is sensing motion or if it is more evident when sensory integration between the SCC and OTO is occurring during the motion. The overall purpose of this research is to further quantify the effects of SVS on various sensorimotor tasks and to gain a more fundamental understanding of how SVS causes SR in the vestibular system. In the context of human space flight, results from this research will help in understanding how SVS may be practically implemented in the future as a component of a comprehensive countermeasure plan for G-transition adaptation.

Galvan-Garza, R. C.↗

A laser ultrasonics-based approach for rapid screening of high entropy alloys

This project demonstrates a laser ultrasonics-based characterization methodology for rapid metallic materials design and discovery via in situ determination of phases, microstructures and elastic properties with respect to temperature. Ultrasonic waves are strongly affected by material microstructure, and therefore serve as a facile means to probe elastic properties, phase content and their size distributions and volume fractions. In this study, a laser ultrasonic technique is used to systematically study the evolution of properties in a set of interrelated simple binary alloys and high entropy alloys (HEA). Phase transformations and microstructural changes inferred from the ultrasonic signals will be correlated with electron microscopy data and predictions using calculations of phase diagrams (CALPHAD). The non-contact and non-destructive ultrasonic testing approach developed in this study could overcome several limitations associated with current material characterization methods for materials discovery. It is expected that laser ultrasonics-based methodology developed in this work will be utilized to evaluate novel graded composition HEAs currently being developed at the Idaho National Laboratory (INL) using advanced manufacturing methods based on direct energy deposition and spark plasma sintering processes, and contribute to accelerate the discovery of HEAs.

36 MATERIALS SCIENCE↗

Integrated Advanced Microwave Sounding Unit-A(AMSU-A). Performance Verification Report: METSAT AMSU-A2 Receiver Assembly, (P/N 1356441-1, S.N F04) S/N 107

The AMSU-A receiver subsystem comprises two separated receiver assemblies; AMSU-Al and AMSU-A2(PN1356441-1). The AMSU-A1 receiver contains 13 channels and the AMSU-A2 receiver 2 channels. The AMSU-AL receiver assembly is further divided into two parts; AMSU-A 1-1 (P/N 1356429-1) and AMSU-A 1-2 (P/N 1356409-1), which contain 9 and 4 channels, respectively. The AMSU-A receiver subsystem stands in between the antenna and signal processing subsystems of the AMSU-A instrument and comprises the RF and IF components from RF isolators to IF attenuators. It receives the RF signals from the antenna subsystem, down-converts the RF signals to IF signals, amplifies and defines the IF signals to proper power level and frequency bandwidth as specified for each channel, and inputs the IF signals to the signal processing subsystem. The test reports for the METSAT AMSU-A receiver subsystem are prepared separately for the A1 and A2 receivers so that each receiver stands alone during integration of instruments into the spacecraft. This test report presents the test data of the METSAT AMSU-A2 Flight Model No.4 (FM4) receiver. The tests are performed per the Acceptance Test Procedure for the AMSU-A Receiver Subsystem, AE-26002/6A. The functional performance tests are conducted either at the component or subsystem level. While the component-level tests are performed over the entire operating temperature range predicted by thermal analysis, the subsystem-level tests are conducted at ambient temperature only.

Kapper, R.↗

Charge Transfer Processes in OPV Materials as Revealed by EPR Spectroscopy

Understanding charge separation and charge transport at a molecular level is crucial for improving the efficiency of organic photovoltaic (OPV) cells. Under illumination of Bulk Heterojunction (BHJ) blends of polymers and fullerenes, various paramagnetic species are formed including polymer and fullerene radicals, radical pairs, and photoexcited triplet states. Light-induced Electron Paramagnetic Resonance (EPR) spectroscopy is ideally suited to study these states in BHJ due to its selectivity in probing the paramagnetic intermediates. Some advanced EPR techniques like light-induced ENDOR spectroscopy and pulsed techniques allow the determination of hyperfine coupling tensors, while high-frequency EPR allows the EPR signals of the individual species to be resolved and their g-tensors to be determined. In these magnetic resonance parameters reveal details about the delocalization of the positive polaron on the various polymer donors which is important for the efficient charge separation in BHJ systems. Time-resolved EPR can contribute to the study of the dynamics of charge separation, charge transfer and recombination in BHJ by probing the unique spectral signatures of charge transfer and triplet states. Furthermore, the potential of the EPR also allows characterization of the intermediates and products of BHJ degradation.

36 MATERIALS SCIENCE↗

Characterization of laboratory-scale hydraulic fracturing for EGS

To investigate the impact of reservoir stimulation by hydraulic fracturing, a series of advanced lab-scale block tests were conducted with multiple measurement methods to characterize the fracture and to assess the operation and the performance of an enhanced or engineered geothermal system (EGS). The stimulation test samples were 330-mm cubic blocks of Sierra White granite with one injection well and four producers drilled into it. Acoustic emissions generated during the fracture initiation and propagation were monitored with twenty AE sensors mounted on all sides of the block to help characterize the fracture initiation and propagation process. The recorded AE signals were analyzed to obtain the event location and the failure mechanism. The localized AE events shows that due to the low viscosity of the fracturing fluid (water), the fracture propagated rapidly and took only about 1.4 s to reach near the block surface. During the fracturing phase, about 47 percent of the events were determined to be shear/mixed mode failure events, 28 percent tensile failure events, and 25 percent compressional failure events. Just after the simulation, a step-rate (constant flowrate) injection test was carried out to investigate the reservoir injectivity enhancement. During this phase additional compressional failure events were observed and the percentages of tensile failure and shear/mixed mode failure decreased. The dramatic increase of the injection rate with small increments of the injection pressure demonstrates the nonlinear response of the fracture to effective normal stress variation with much higher fracture opening increase during the low effective normal stress interval. Hydraulic fracturing tests under different stress levels show that more AE hits/events are recorded when the rock block is under higher applied stress. The reconstructed 3D fracture geometry shows good agreement with the AE monitoring results. After fracturing, a tracer test was carried out and the fracture aperture was estimated to be around 139 μm. The tracer recovery curve shows two linear portions of the tracer tail on a semi-log plot similar to that observed in some field data and predicted by numerical modeling. Laser scanning of the fracture surfaces indicates that the induced fracture has a rough surface with a joint roughness coefficient (JRC) of 12.98 and tortuosity of 1.10, both of which are slightly larger than that from the Brazilian test fracture on the same rock. The thin section and SEM observations show that the fracture follows the weak boundaries between the Quartz and Albite grains or the weak beddings in the grains.

58 GEOSCIENCES↗

Capturing the microbial volatilome: an oft overlooked 'ome'

Among the diverse metabolites produced by microbial communities, some are volatile. Volatile organic compounds (VOCs) are vigorously cycled by microbes as metabolic substrates and products and as signaling molecules. Yet, current microbial metabolomic studies predominantly focus on nonvolatile metabolites and overlook VOCs, which therefore represent a missing component of the metabolome. Advances in VOC detection now allow simultaneous observation of the numerous VOCs constituting the ‘volatilome’ of microbial systems. Here, we present a roadmap for integrating and advancing VOC and other ‘omics approaches and highlight the potential for realtime VOC measurements to help overcome limitations in discrete ‘omics sampling. Including volatile metabolites in metabolomics, both conceptually and in practice, will build a more comprehensive understanding of microbial processes across ecological communities.

59 BASIC BIOLOGICAL SCIENCES↗

Reconfigurable, Cognitive Software-Defined Radio

Software-defined radio (SDR) technology allows radios to be reconfigured to perform different communication functions without using multiple radios to accomplish each task. Intelligent Automation, Inc., has developed SDR platforms that switch adaptively between different operation modes. The innovation works by modifying both transmit waveforms and receiver signal processing tasks. In Phase I of the project, the company developed SDR cognitive capabilities, including adaptive modulation and coding (AMC), automatic modulation recognition (AMR), and spectrum sensing. In Phase II, these capabilities were integrated into SDR platforms. The reconfigurable transceiver design employs high-speed field-programmable gate arrays, enabling multimode operation and scalable architecture. Designs are based on commercial off-the-shelf (COTS) components and are modular in nature, making it easier to upgrade individual components rather than redesigning the entire SDR platform as technology advances.

Bhat, Arvind↗

Recent Advancements in Tomographic Gamma Scanning for Non- Destructive Assay - 17321

Canberra Industries has recently designed and built a Tomographic Gamma Scanning (TGS) system for the deployment in a nuclear facility. The TGS technique combines high-resolution gamma spectroscopy with low spatial resolution 3- dimensional image reconstruction to provide increased accuracy over traditional approaches for the assay of non-uniform source distributions in low-to medium-density containers. The TGS system has been optimized to measure 120 liter drums and has the capability to measure containers of various sizes. Canberra has incorporated numerous enhancements and improvements to the latest system in both its hardware and software components. The signal processing chain and data analysis software have been configured to use either an electronic pulser or digital signal processing (DSP) electronics for dead time corrections. In the case of using the DSP electronics, the need to calibrate and maintain a pulser can be eliminated without sacrificing any performance. For the 120 liter container, the TGS system has been calibrated and validated with three different spatial resolutions, using two collimator aperture sizes, measuring 2.54 and 1.27 cm in width. The system has also been supplied and calibrated with a wide, rectangular collimator (25.4 cm W x 10.2 cm H) for scanning containers solely in the vertical axis. The TGS system also has an automated attenuator assembly, which has the capability to use a combination of attenuators to reduce the count rate for high activity samples. An extensive measurement campaign was performed in addition to the calibration verification to evaluate the accuracy of the system using rod sources, point sources, and a variety of matrices and source distributions. Improvements to the evaluation of the total measurement uncertainty based upon these studies have been incorporated into the analysis software package. Finally, the performance of this new TGS system will be demonstrated in the context of Canberra's previous TGS systems, including several 208 liter-based systems and a smaller, 20 liter container TGS system. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A study of 'onboard' data processing for typical astrophysics payloads

The data, signal flow, and ground processing requirements for a typical set of X-ray and gamma-ray experiments were examined. A set of algorithms for ground processing were derived and these were taken as requirements imposed on 'onboard' spacecraft computers. Five types of CPU microprocessors were evaluated and compared with one another to determine the degree to which the data processing could be performed onboard the spacecraft. These included the NASA Standard Spacecraft Computer (NSSC-1), the Z-80, a Z-80 augmented with an auxiliary fast multiply chip, and an advanced augmented Z-80 with virtually unlimited memory. These CPU were investigated when used in a centralized mode, an experiment dedicated mode, and a hybrid of the first two modes. It was found that the use of onboard processing can significantly reduce downlink data rates for typical payloads, and may lead to greater efficiency of operation. Quantitative data for gamma-ray and X-ray payloads will be presented, and the results of the analysis discussed.

Stout, C. M.↗

System identification methods for aircraft flight control development and validation

System-identification methods compose a mathematical model, or series of models, from measurements of inputs and outputs of dynamic systems. The extracted models allow the characterization of the response of the overall aircraft or component subsystem behavior, such as actuators and on-board signal processing algorithms. This paper discusses the use of frequency-domain system-identification methods for the development and integration of aircraft flight-control systems. The extraction and analysis of models of varying complexity from nonparametric frequency-responses to transfer-functions and high-order state-space representations is illustrated using the Comprehensive Identification from FrEquency Responses (CIFER) system-identification facility. Results are presented for test data of numerous flight and simulation programs at the Ames Research Center including rotorcraft, fixed-wing aircraft, advanced short takeoff and vertical landing (ASTOVL), vertical/short takeoff and landing (V/STOL), tiltrotor aircraft, and rotor experiments in the wind tunnel. Excellent system characterization and dynamic response prediction is achieved for this wide class of systems. Examples illustrate the role of system-identification technology in providing an integrated flow of dynamic response data around the entire life-cycle of aircraft development from initial specifications, through simulation and bench testing, and into flight-test optimization.

Tischler, Mark B.↗

A pulsed eddy current probe for inspection of support plates from within Alloy-800 steam generator tubes

Support plate degradation and fouling in nuclear steam generators (SGs) can lead to SG tube corrosion and loss of efficiency. Inspection and monitoring of these conditions can be integrated with preventive maintenance programs, thereby advancing station-life management processes. A prototype pulsed eddy current (PEC) probe, targeting inspection issues associated with SG tubes in SS410 tube support plate structures, has been developed using commercial finite element (FE) software. FE modeling was used to identify appropriate driver and pickup coil configurations for optimum sensitivity to changes in gap and offset for Alloy-800 SG tubes passing through 25 mm thick SS410 support plates. Experimental measurements using a probe that was manufactured based on the modeled configuration, were used to confirm the sensitivity of differential PEC signals to changes in relative position of the tube within the tube support plate holes. Models investigated the effect of shift and tilt of tube with respect to hole centers. Near hole centers and for small shifts, modeled signal amplitudes from the differentially connected coil pairs were observed to change linearly with tube shift. This was in agreement with experimentally measured TEC coil response. The work paves the way for development of a system targeting the inspection and evaluation of support plate structures in steam generators.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NASA's next generation all-digital deep space network breadboard receiver

This paper describes the breadboard advanced receiver (ARX) that is currently being built for future use in NASA's deep space network (DSN). This receiver has unique requirements in having to operate with very weak signals from deep space probes and provide high quality telemetry and tracking data. The hybrid analog/digital receiver performs multiple functions including carrier, subcarrier and symbol synchronization. Tracking can be achieved for either residual, suppressed or hybrid carriers and for both sinusoidal and square wave subcarriers. System requirements are specified and a functional description of the ARX is presented. The various digital signal processing algorithms used are also discussed and illustrated with block diagrams. Other functions such as time tagged Doppler extraction and monitor/control are also discussed including acquisition algorithms and lock detection schemes.

Hinedi, Sami↗

Circadian regulation of human sleep and age-related changes in its timing, consolidation and EEG characteristics

The light-entrainable circadian pacemaker located in the suprachiasmatic nucleus of the hypothalamus regulates the timing and consolidation of sleep by generating a paradoxical rhythm of sleep propensity; the circadian drive for wakefulness peaks at the end of the day spent awake, ie close to the onset of melatonin secretion at 21.00-22.00 h and the circadian drive for sleep crests shortly before habitual waking-up time. With advancing age, ie after early adulthood, sleep consolidation declines, and time of awakening and the rhythms of body temperature, plasma melatonin and cortisol shift to an earlier clock hour. The variability of the phase relationship between the sleep-wake cycle and circadian rhythms increases, and in old age sleep is more susceptible to internal arousing stimuli associated with circadian misalignment. The propensity to awaken from sleep advances relative to the body temperature nadir in older people, a change that is opposite to the phase delay of awakening relative to internal circadian rhythms associated with morningness in young people. Age-related changes do not appear to be associated with a shortening of the circadian period or a reduction of the circadian drive for wake maintenance. These changes may be related to changes in the sleep process itself, such as reductions in slow-wave sleep and sleep spindles as well as a reduced strength of the circadian signal promoting sleep in the early morning hours. Putative mediators and modulators of circadian sleep regulation are discussed.

Review, Tutorial↗

Advanced Signal Conditioners for Data-Acquisition Systems

Signal conditioners embodying advanced concepts in analog and digital electronic circuitry and software have been developed for use in data-acquisition systems that are required to be compact and lightweight, to utilize electric energy efficiently, and to operate with high reliability, high accuracy, and high power efficiency, without intervention by human technicians. These signal conditioners were originally intended for use aboard spacecraft. There are also numerous potential terrestrial uses - especially in the fields of aeronautics and medicine, wherein it is necessary to monitor critical functions. Going beyond the usual analog and digital signal-processing functions of prior signal conditioners, the new signal conditioner performs the following additional functions: It continuously diagnoses its own electronic circuitry, so that it can detect failures and repair itself (as described below) within seconds. It continuously calibrates itself on the basis of a highly accurate and stable voltage reference, so that it can continue to generate accurate measurement data, even under extreme environmental conditions. It repairs itself in the sense that it contains a micro-controller that reroutes signals among redundant components as needed to maintain the ability to perform accurate and stable measurements. It detects deterioration of components, predicts future failures, and/or detects imminent failures by means of a real-time analysis in which, among other things, data on its present state are continuously compared with locally stored historical data. It minimizes unnecessary consumption of electric energy. The design architecture divides the signal conditioner into three main sections: an analog signal section, a digital module, and a power-management section. The design of the analog signal section does not follow the traditional approach of ensuring reliability through total redundancy of hardware: Instead, following an approach called spare parts tool box, the reliability of each component is assessed in terms of such considerations as risks of damage, mean times between failures, and the effects of certain failures on the performance of the signal conditioner as a whole system. Then, fewer or more spares are assigned for each affected component, pursuant to the results of this analysis, in order to obtain the required degree of reliability of the signal conditioner as a whole system. The digital module comprises one or more processors and field-programmable gate arrays, the number of each depending on the results of the aforementioned analysis. The digital module provides redundant control, monitoring, and processing of several analog signals. It is designed to minimize unnecessary consumption of electric energy, including, when possible, going into a low-power "sleep" mode that is implemented in firmware. The digital module communicates with external equipment via a personal-computer serial port. The digital module monitors the "health" of the rest of the signal conditioner by processing defined measurements and/or trends. It automatically makes adjustments to respond to channel failures, compensate for effects of temperature, and maintain calibration.

Lucena, Angel↗

The ACCP Inclined Orbit Project: Enabling New and Synergistic Aerosol Remote Sensing Inversions

Atmospheric aerosols have high spatiotemporal variations due to their diverse sources including windblown dust, wildfires, volcanic eruptions, and anthropogenic emissions. These aerosols also have strong diurnal emission characteristics that influence long-range transport, air quality, Earth’s radiation budget, biogeochemical cycles, and weather forecasting. While current sensors can measure the steady-state of global 3D cloud and aerosol properties, we lack the observational datasets to discover the diurnal variability of aerosols, even at seasonal and regional scales, because these missions utilize sun synchronous orbits. An Aerosols and Clouds, Convection and Precipitation (ACCP) observing system has been established as part of NASA’s new Earth System Observatory (ESO) to fulfill the science needs presented in the 2017 Earth Science Decadal Survey. The selected ACCP architecture encompasses sensors in two orbit planes, one of which utilizes an inclined orbit (nominally ~55 degrees at a 407 km altitude) to advance our understanding of aerosol and cloud properties and target the dynamics of the cloud and aerosol processes on sub-daily time scales. The anticipated instrumentation suite for the ACCP Inclined Orbit Project is a Stereo Camera System, Polarimeter, Microwave Radiometer, Two-Frequency Radar, and Backscatter Lidar. The polarimeter is expected to have multiple wavelength bands and viewing angles to enable accurate retrievals of aerosol microphysical and optical properties. The backscatter lidar will provide vertical profiles of attenuated backscatter and depolarization ratio at two wavelengths, with better daytime signal-to-noise ratio than previous space-based lidar systems to improve aerosol detection/typing and estimates of aerosol optical properties. The stereo camera system, while designed primarily for clouds, will also provide aerosol plume heights and air motions at the plume heights. This invited presentation will provide (1) an overview of the ACCP Inclined Orbit Project, (2) a description of the new sensor capabilities and orbital characteristics, and (3) a preview of the potential for new synergistic aerosol inversion techniques.

John E Yorks↗

Advances in measuring techniques for turbine cooling test rigs

Surface temperature distribution measurements for turbine vanes and blades were obtained by measuring the infrared energy emitted by the airfoil. The IR distribution can be related to temperature distribution by suitable calibration methods and the data presented in the form of isotherm maps. Both IR photographic and real time electro-optical methods are being investigated. The methods can be adapted to rotating as well as stationary targets, and both methods can utilize computer processing. Pressure measurements on rotating components are made with a rotating system incorporating 10 miniature transducers. A mercury wetted slip ring assembly was used to supply excitation power and as a signal transfer device. The system was successfully tested up to speeds of 9000 rpm and is now being adapted to measure rotating blade airflow quantities in a spin rig and a research engine.

Pollack, F. G.↗

Entangled Photon Spectroscopy

Conspectus The enhanced interest in quantum-related phenomena has provided new opportunities for chemists to push the limits of detection and analysis of chemical processes. As some have called this the second quantum revolution, a time has come to apply the rules learned from previous research in quantum phenomena toward new methods and technologies important to chemists. While there has been great interest recently in quantum information science (QIS), the quest to understand how nonclassical states of light interact with matter has been ongoing for more than two decades. Our entry into this field started around this time with the use of materials to produce nonclassical states of light. Here, the process of multiphoton absorption led to photon-number squeezed states of light, where the photon statistics are sub-Poissonian. In addition to the great interest in generating squeezed states of light, there was also interest in the formation of entangled states of light. While much of the effort is still in foundational physics, there are numerous new avenues as to how quantum entanglement can be applied to spectroscopy, imaging, and sensing. These opportunities could have a large impact on the chemical community for a broad spectrum of applications. Here, we discuss the use of entangled (or quantum) light for spectroscopy as well as applications in microscopy and interferometry. The potential benefits of the use of quantum light are discussed in detail. From the first experiments in porphyrin dendrimer systems by Dr. Dong-Ik Lee in our group to the measurements of the entangled two photon absorption cross sections of biological systems such as flavoproteins, the usefulness of entangled light for spectroscopy has been illustrated. These early measurements led the way to more advanced measurements of the unique characteristics of both entangled light and the entangled photon absorption cross-section, which provides new control knobs for manipulating excited states in molecules. The first reports of fluorescence-induced entangled processes were in organic chromophores where the entangled photon cross-section was measured. These results would later have widespread impact in applications such as entangled two-photon microscopy. From our design, construction and implementation of a quantum entangled photon excited microscope, important imaging capabilities were achieved at an unprecedented low excitation intensity of 10 7 photons/s, which is 6 orders of magnitude lower than the excitation level for the classical two-photon image. New reports have also illustrated an advantage of nonclassical light in Raman imaging as well. From a standpoint of more precise measurements, the use of entangled photons in quantum interferometry may offer new opportunities for chemistry research. Experiments that combine molecular spectroscopy and quantum interferometry, by utilizing the correlations of entangled photons in a Hong–Ou–Mandel (HOM) interferometer, have been carried out. The initial experiment showed that the HOM signal is sensitive to the presence of a resonant organic sample placed in one arm of the interferometer. In addition, parameters such as the dephasing time have been obtained with the opportunity for even more advanced phenomenology in the future.

36 MATERIALS SCIENCE↗