Search NASA⌕ Search

SEARCH · Search NASA

Results for “Algorithm Development and Nuclear Data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Detailed modeling of fission with F R E Y A

For many years, the state of the art for treating fission in radiation transport codes has involved sampling from average distributions. However, such “average” fission models have limited interaction-by-interaction capabilities. Energy is not explicitly conserved and no correlations are available because all particles are emitted isotropically and independently. However, in a true fission event, the energies, momenta and multiplicities of emitted particles are correlated. Such correlations are interesting for many modern applications, including detector development and detection of small amounts of special material. Recently, several Monte Carlo codes have become available that calculate complete fission events. Event-by-event techniques are particularly useful because it is possible to obtain the fission products as well as the prompt neutrons and photons emitted during an individual fission process, all with complete kinematic information. It is therefore possible to extract any desired correlation observables. Such codes, when included in broader Monte Carlo transport codes, such as MCNP, can be made broadly available to the community. One such code, FREYA (Fission Reaction Event Yield Algorithm), is particularly fast and can readily generate large samples of complete fission events. We briefly describe here the physics in FREYA and compare our results with relevant available data on prompt neutron and photon emission. We discuss correlated measurements in particular for validation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Se-SAD serial femtosecond crystallography datasets from selenobiotinyl-streptavidin

We provide a detailed description of selenobiotinyl-streptavidin (Se-B SA) co-crystal datasets recorded using the Coherent X-ray Imaging (CXI) instrument at the Linac Coherent Light Source (LCLS) for selenium single-wavelength anomalous diffraction (Se-SAD) structure determination. Se-B SA was chosen as the model system for its high affinity between biotin and streptavidin where the sulfur atom in the biotin molecule (C 10 H 16 N 2 O 3 S) is substituted with selenium. The dataset was collected at three different transmissions (100, 50, and 10%) using a serial sample chamber setup which allows for two sample chambers, a front chamber and a back chamber, to operate simultaneously. Diffraction patterns from Se-B SA were recorded to a resolution of 1.9 Å. The dataset is publicly available through the Coherent X-ray Imaging Data Bank (CXIDB) and also on LCLS compute nodes as a resource for research and algorithm development.

36 MATERIALS SCIENCE↗

Coherent soft X-ray diffraction imaging of coliphage PR772 at the Linac coherent light source

Single-particle diffraction from X-ray Free Electron Lasers offers the potential for molecular structure determination without the need for crystallization. In an effort to further develop the technique, we present a dataset of coherent soft X-ray diffraction images of Coliphage PR772 virus, collected at the Atomic Molecular Optics (AMO) beamline with pnCCD detectors in the LAMP instrument at the Linac Coherent Light Source. The diameter of PR772 ranges from 65–70 nm, which is considerably smaller than the previously reported ~600 nm diameter Mimivirus. This reflects continued progress in XFEL-based single-particle imaging towards the single molecular imaging regime. As a result, the data set contains significantly more single particle hits than collected in previous experiments, enabling the development of improved statistical analysis, reconstruction algorithms, and quantitative metrics to determine resolution and self-consistency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Utilizing the Dynamic Networks Data Processing and Analysis Experiment (DNE18) to Establish Methodologies for the Comparison of Automatic Infrasonic Signal Detectors

The Dynamic Networks Experiment 2018 (DNE18) was a collaborative effort between Los Alamos National Laboratory (LANL), Sandia National Laboratories (SNL), Lawrence Livermore National Laboratory (LLNL) and Pacific Northwest National Laboratory (PNNL) designed to evaluate methodologies for multi-modal data ingestion and processing. One component of this virtual experiment was a quantitative assessment of current capabilities for infrasound data processing, beginning with the establishment of a baseline for infrasound signal detection. To produce such baselines, SNL and LANL exploited a common dataset of infrasound data recorded across a regional network in Utah from December 2010 through February 2011. We utilize two automated signal detectors, the Adaptive F-Detector (AFD) and the Multivariate Adaptive Learning Detector (MALD) to produce automated signal detection catalogs and an analyst-produced catalog. Comparisons indicate that automatic detectors may be able to identify small amplitude, low SNR events that cannot be identified by analyst review. We document detector performance in terms of precision and recall, demonstrating that the AFD is more precise, but the MALD has higher recall. We use a synthetic dataset of signals embedded in pink noise in order to highlight shortcomings in assessing detection algorithms for low signal to noise ratio signals which are commonly of interest to the nuclear monitoring community. For comparisons utilizing the synthetic dataset, the AFD has higher recall while precision is equal for both detectors. These results indicate that both detectors perform well across a variety of background noise environments; however, both detectors fail to identify repetitive, short duration signals arriving from similar backazimuths. These failures represent specific scenarios that could be targeted for further detector development.

97 MATHEMATICS AND COMPUTING↗

OpenCV and TYZX : video surveillance for tracking.

As part of the National Security Engineering Institute (NSEI) project, several sensors were developed in conjunction with an assessment algorithm. A camera system was developed in-house to track the locations of personnel within a secure room. In addition, a commercial, off-the-shelf (COTS) tracking system developed by TYZX was examined. TYZX is a Bay Area start-up that has developed its own tracking hardware and software which we use as COTS support for robust tracking. This report discusses the pros and cons of each camera system, how they work, a proposed data fusion method, and some visual results. Distributed, embedded image processing solutions show the most promise in their ability to track multiple targets in complex environments and in real-time. Future work on the camera system may include three-dimensional volumetric tracking by using multiple simple cameras, Kalman or particle filtering, automated camera calibration and registration, and gesture or path recognition.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

LDRD Abbreviated report: High-Order General-Discrete-Ordinates Method Enabling Efficient Deterministic Transport in Hydrodynamic Simulations

Deterministic transport simulations for national-security and energy applications often operate in high-dimensional phase-space, where accuracy and cost both become major challenges. A common numerical artifact in such problems is the “ray-effect,” which appears as unphysical streaks. Beyond misinterpretation, these artifacts can contaminate tightly coupled physics, such as fluid dynamics, radiation-hydrodynamics, and laser-plasma interactions, eroding the predictive capability of entire multiphysics workflows. Our objective was to make high-dimension studies practical on modern hardware while mitigating the ray-effect without relying on prohibitively expensive sampling approaches such as Monte Carlo methods. We developed the Generic Discretization Library (GenDiL), a Graphics Processing Unit (GPU)-first framework that uses high-order Discontinuous Galerkin (DG) methods and matrix-free algorithms to reduce memory usage and improve computational efficiency, critical for phase-space simulations. GenDiL supports phase-space adaptivity in both mesh size and polynomial order (hp-adaptivity) to place resolution only where it is needed. A central capability is Local Dimensional Refinement (LDR), which couples lower-dimension continuum models to higher-dimension kinetic models through stable and conservative interfaces, so that high-fidelity physics is applied only in regions where it is essential. Building on the GenDiL framework, we developed the General SN (GSN) family of algorithms as a true generalization of the polar SN approach (discrete ordinates, often denoted SN). Rather than tying discrete ordinates to a specific polar change of coordinates, GSN formulates transport on an arbitrary change of coordinates chosen to reduce ray-effect. We studied two complementary variants: an analytic variant, where the coordinate map is prescribed in advance by a closed-form function; and a data-driven variant, where a quantity of interest, such as the net flux, guides the coordinate system. GenDiL provides the library infrastructure for efficient GPU execution, but the GSN concept is algorithmic and independent of any one library. Across representative high-dimension tests, including non-symmetric solutions, both variants delivered strong ray-effect mitigation at practical cost, moving four- to six-dimensional analysis toward repeatable, routine studies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-J-11: A New Optical Method to Register Patient External Motion

Purpose: To devise and implement a new system to measure and register the patient motion during radiotherapy treatments. Methods: The system can obtain the position of several points in the 3D-space, through their projections in the 2D-images recorded by two cameras. The algorithm needs a series of constants, that are obtained using the images of a calibrated phantom.To test the system, some adhesive labels were placed on the surface of an object. Two cameras recorded the moving object over time. An in-house developed software localized the labels in each image. In the first pair of images, the program used a first approximation given by the user. In the subsequent images, it used the last position as an approximate location. The final exact coordinates of the point were obtained in a two-step process using the contrast of the images. From the 2D-positions of the point in each frame, the 3D-trajectories of each of these marks were obtained.The system was tested with linear displacements, oscillations of a mechanical oscillator, circular trajectories of a rotating disk, and with respiratory motion of a volunteer. Results: Trajectories of several points were reproduced with sub-millimeter accuracy in the three directions of the space. The system was able to follow periodic motion with amplitudes lower than 0.5mm; and trajectories of rotating points at speeds up to 200mm/s. The software could also track accurately the respiration motion of a person. Conclusion: A new, inexpensive optical tracking system for patient motion has been demonstrated. The system detects motion with high accuracy. Installation and calibration of the system is simple and quick. Data collection is not expected to involve any discomfort for the patient, nor any delay for the treatment. The system could be also used as a method of warning for patient movements, and for gating. We acknowledge financial support from Fundacion Mutua Madrilena, Madrid, Spain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

IBEX: An open infrastructure software platform to facilitate collaborative work in radiomics

Purpose: Radiomics, which is the high-throughput extraction and analysis of quantitative image features, has been shown to have considerable potential to quantify the tumor phenotype. However, at present, a lack of software infrastructure has impeded the development of radiomics and its applications. Therefore, the authors developed the imaging biomarker explorer (IBEX), an open infrastructure software platform that flexibly supports common radiomics workflow tasks such as multimodality image data import and review, development of feature extraction algorithms, model validation, and consistent data sharing among multiple institutions. Methods: The IBEX software package was developed using the MATLAB and C/C++ programming languages. The software architecture deploys the modern model-view-controller, unit testing, and function handle programming concepts to isolate each quantitative imaging analysis task, to validate if their relevant data and algorithms are fit for use, and to plug in new modules. On one hand, IBEX is self-contained and ready to use: it has implemented common data importers, common image filters, and common feature extraction algorithms. On the other hand, IBEX provides an integrated development environment on top of MATLAB and C/C++, so users are not limited to its built-in functions. In the IBEX developer studio, users can plug in, debug, and test new algorithms, extending IBEX’s functionality. IBEX also supports quality assurance for data and feature algorithms: image data, regions of interest, and feature algorithm-related data can be reviewed, validated, and/or modified. More importantly, two key elements in collaborative workflows, the consistency of data sharing and the reproducibility of calculation result, are embedded in the IBEX workflow: image data, feature algorithms, and model validation including newly developed ones from different users can be easily and consistently shared so that results can be more easily reproduced between institutions. Results: Researchers with a variety of technical skill levels, including radiation oncologists, physicists, and computer scientists, have found the IBEX software to be intuitive, powerful, and easy to use. IBEX can be run at any computer with the windows operating system and 1GB RAM. The authors fully validated the implementation of all importers, preprocessing algorithms, and feature extraction algorithms. Windows version 1.0 beta of stand-alone IBEX and IBEX’s source code can be downloaded. Conclusions: The authors successfully implemented IBEX, an open infrastructure software platform that streamlines common radiomics workflow tasks. Its transparency, flexibility, and portability can greatly accelerate the pace of radiomics research and pave the way toward successful clinical translation.

60 APPLIED LIFE SCIENCES↗

FY23 Progress Report: SRNL Analysis of ICCWR LCM and WAMS data for Corrosion and Cracking

Algorithms for Machine Learning (ML) and data analysis for the 3013 Surveillance Program have been developed in an ongoing collaborative effort by the Savannah River National Laboratory (SRNL) and the University of South Carolina (USC). The objective of the algorithms is to automate the identification of corrosion and crack formation in the Inner Container Closure Weld Region (ICCWR) of the canister system used to store Pu-bearing material. Data for corrosion and cracking is collected from large binary files generated by a Laser Confocal Microscope (LCM), the Wide Area 3D Measurement System (WAMS), and in a recent proposal, by a Scanning Electron Microscope (SEM). The ML software uses the physical attributes in the data files (e.g., one or all of: height, color, and grayscale values as functions of position in a plane projection) to detect the presence of surface corrosion and cracking after being trained on similar data with the features to be detected labeled.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Unsupervised Learning for Improved Gamma-Ray Spectrometry in Pixelated Cadmium Zinc Telluride (CZT) Detectors

Machine learning has been found to be ubiquitously useful across many industries, presenting an opportunity to improve radiation detection performance using data-driven algorithms. Improved detector resolution can aid in the detection, identification, and quantification of radionuclides. Here, in this work, a novel, data-driven, unsupervised learning approach is developed to improve detector spectral characteristics by learning, and subsequently rejecting, poorly performing regions of the pixelated detector. Feature engineering is used to fit individual characteristic photo peaks to a Doniach lineshape with a linear background model. Then, principal component analysis is used to learn a lower-dimension latent space representation of each photo peak where the pixels are clustered, and subsequently ranked, based on the cluster mean distance to an optimal point. Pixels within the worst cluster(s) are rejected to improve the full-width at half-maximum (FWHM) by 10% to 15% (relative to the bulk detector) at 50% net efficiency when applied to training data obtained from measurements of a 100 μCi 154 Eu source using a H3D M400i pixelated cadmium zinc telluride detector. These results compare well with, but do not outperform, a greedy algorithm that accumulates pixels in order of FWHM from lowest to highest used as a benchmark. In the future, this approach can be extended to include the detector energy and angular response. Finally, the model is applied to newly seen natural and enriched uranium spectra relevant for nuclear safeguards applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New approach to terahertz diagnostics of human psychoemotional state

A new approach to terahertz (THz) diagnostics of the human psychoemotional state is proposed, based on the analysis of the THz contribution to the total signal while simultaneously recording the IR and THz emissions from the human body (hereinafter referred to as the IR – THz image). The developed image-processing algorithm allows extraction of the informative contribution determined by the THz radiation from the total signal perceived by the recording system. Simultaneous registration of the IR – THz images of the human face and the psychophysiological indicators are carried out in situations of physical stress (short-term intense physical exercise – squats functional test), electrical stimulation, and information stress (cognitive load – simple arithmetic mental calculations). The obtained data are compared with those of similar measurements at rest. It is shown that using cluster analysis of IR – THz images it is possible to divide the test subjects into classes according to the type of reaction of the circulatory system under stressful conditions. (paper)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

DETECTION OF FAST TRANSIENTS WITH RADIO INTERFEROMETRIC ARRAYS

Next-generation radio arrays, including the Square Kilometre Array (SKA) and its pathfinders, will open up new avenues for exciting transient science at radio wavelengths. Their innovative designs, comprising a large number of small elements, pose several challenges in digital processing and optimal observing strategies. The Giant Metre-wave Radio Telescope (GMRT) presents an excellent test-bed for developing and validating suitable observing modes and strategies for transient experiments with future arrays. Here we describe the first phase of the ongoing development of a transient detection system for GMRT that is planned to eventually function in a commensal mode with other observing programs. It capitalizes on the GMRT's interferometric and sub-array capabilities, and the versatility of a new software backend. We outline considerations in the plan and design of transient exploration programs with interferometric arrays, and describe a pilot survey that was undertaken to aid in the development of algorithms and associated analysis software. This survey was conducted at 325 and 610 MHz, and covered 360 deg{sup 2} of the sky with short dwell times. It provides large volumes of real data that can be used to test the efficacies of various algorithms and observing strategies applicable for transient detection. We present examples that illustrate the methodologies of detecting short-duration transients, including the use of sub-arrays for higher resilience to spurious events of terrestrial origin, localization of candidate events via imaging, and the use of a phased array for improved signal detection and confirmation. In addition to demonstrating applications of interferometric arrays for fast transient exploration, our efforts mark important steps in the roadmap toward SKA-era science.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Continuous and fast calibration of the CMS experiment: design of the automated workflows and operational experience

The exploitation of the full physics potential of the LHC experiments requires fast and efficient processing of the largest possible dataset with the most refined understanding of the detector conditions. To face this challenge, the CMS collaboration has setup an infrastructure for the continuous unattended computation of the alignment and calibration constants, allowing for a refined knowledge of the most time-critical parameters already a few hours after the data have been saved to disk. This is the prompt calibration framework which, since the beginning of the LHC Run-I, enables the analysis and the High Level Trigger of the experiment to consume the most up-to-date conditions optimizing the performance of the physics objects. In the Run-II this setup has been further expanded to include even more complex calibration algorithms requiring higher statistics to reach the needed precision. This imposed the introduction of a new paradigm in the creation of the calibration datasets for unattended workflows and opened the door to a further step in performance. The paper reviews the design of these automated calibration workflows, the operational experience in the Run-II and the monitoring infrastructure developed to ensure the reliability of the service.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Global Event-identifier Module: A distributed digital approach to event-of-interest identification logic for physics experiments

The demands from current data acquisition systems are to acquire data from a large number of detectors (or signals) while providing a high throughput. This can be achieved by having some preprocessing capability in the data acquisition system so that it can identify the events of interest. Precise selection of events with minimal time for identification and preprocessing is an experimental challenge. To address this challenge, we have developed a ''Global Event-identifier Module'' (GEM) on the CAMAC platform, which can flexibly adapt to the experimental requirements and validate an event with minimal time. GEM is a single width CAMAC module capable of operating in a ''distributed'' data acquisition environment where multiple CAMAC crates (each with one GEM module) can be used to collect synchronized data from all the crates. Event-of-interest decision can be made on signals connected to different crates. Inter-GEM communication is via the ubiquitous ethernet (unshielded twisted pair, CAT5) cable. The event of interest is decided within 32 ns (excluding cable delay). Implementation is accomplished using field programmable gate array which enables greater flexibility for algorithm modifications and updates without hardware changes. GEM supports unified, distributed, and multi-strobe data acquisition, enabling higher throughput, with data collection from a large number of signals by selective reads of events of interest as determined by the experimenter while providing timestamped data of each event.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Benchmarking of Different Inverse Point Kinetics Implementations for an Autocorrected Reactimeter Algorithm

In November 2017, the Transient Reactor Test Facility returned to operation. Since that time, many transient test series have been completed; each has provided valuable data for materials performance, reactor safety that can be applied in future designs. During each experimental series, detector count rates provided important information on the core behavior during transients. However, a limitation of these data is that variations in the neutron distribution during experiments cause errors when attempting to infer reactivity evolution from detector signals. Neutron physics codes can be used to compute the flux shape variations. However, this is a poor solution when the experimental data is used to do verification, validation and uncertainty quantification (VVUQ) on codes. Indeed, if the output of the code is used both as a reference and to correct what the reference is compared to, the circular dependency limits the quality of the VVUQ approach. To overcome this problem, an Autocorrected Reactimeter Algorithm (ACRA) has been developed. This approach infers time-dependent reactivity evolution by testing different spatial corrections and selecting the one that minimizes reactivity variations when the core is in a frozen configuration (i.e. when there is no variation in parameters affecting reactivity). However, the scope of this method was limited to transients where there were negligible thermal feedback. Indeed, the core is never in a frozen configuration when the fuel temperature varies during the whole transient. This is our motivation for the development of an improved version of the ACRA which does not require frozen configurations

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A data-driven framework for error estimation and mesh-model optimization in system-level thermal-hydraulic simulation

We report over the past decades, several computer codes have been developed for simulation and analysis of thermal-hydraulics and system response in nuclear reactors under operating, abnormal transient, and accident conditions. However, simulation errors and uncertainties still inevitably exist even while these codes have been extensively assessed and used. In this work, a data-driven framework (Optimal Mesh/Model Information System, OMIS) is formulated and demonstrated to estimate simulation error and suggest optimal selection of computational mesh size (i.e., nodalization) and constitutive correlations (e.g., wall functions and turbulence models) for low-fidelity, coarse-mesh thermal-hydraulic simulation, in order to achieve accuracy comparable to that of high-fidelity simulation. Using results from high-fidelity simulations and experimental data with many fast-running low-fidelity simulations, an error database is built and used to train a machine learning model that can determine the relationship between local simulation error and local physical features. This machine learning model is then used to generate insight and help correct low-fidelity simulations for similar physical conditions. The OMIS framework is designed as a modularized six-step procedure and accomplished with state-of-the-art methods and algorithms. A mixed-convection case study was performed to illustrate the entire framework.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Advanced Fuel Cycle Cost Basis Report: Module D1-7 Contact-Handled Pelletized Pressurized Heavy Water (PHWR) UOX Fuel Fabrication (Rev.1)

In addition to literature-based pressurized heavy-water reactor (PHWR) fuel price information in the 2017 AFC-CBR, the what-it-takes (WIT) unit cost data in this update is informed by new analysis and escalation of the 1978 PHWR-UOX fuel life cycle cost (LCC) data from ORNL reports prepared for the 1977–1980 Nonproliferation Alternative Systems Assessment Program (NASAP). (These reports are referenced and summarized in detail in Module D1-PR.) The PHWR fuel fabrication LCC data in these reports is scaled from a bottom-up cost estimate for a reference technology pressurized-water reactor (PWR)—uranium oxide (UOX) fuel fabrication plant by using algorithms that consider the manufacturing process complexity, fuel design complexity, plant floor space requirements, and the radiation and health, safety, and environmental (HS&E) regulatory environment of PHWR-UOX fuel production vis-à-vis light-water reactor (LWR)-UOX production (PWR fuel in this case). The module name has been changed from “Canadian Deuterium Uranium (CANDU)” to the more generic PHWR fuel fabrication in recognition that not all power reactors that might use this fuel type are considered. Unfortunately, the detailed algorithms and their design bases were not archived at the end of the NASAP effort of the commercial CANDU concept specifically developed in the middle of the last century by Atomic Energy of Canada Limited (AECL).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Optimizing Long-term Monitoring of Radiation Air Dose Rates - 19169

Radiation air dose rates near the Fukushima Daiichi Nuclear Power Plant (NPP) have been steadily decreasing over the past seven years since the accident in March 2011. After seven years, the radiation monitoring program is expected to transition from short-term emergency responses to long-term monitoring. The objectives of long-term monitoring are often different from early emergency responses, since extensive data accumulation has led to an understanding of contaminant distributions and mobility. The main long-term monitoring objectives are (1) to confirm system stability and the continuing reduction of contaminant and hazard levels, (2) to provide assurance for the public, (3) to accumulate the basic datasets for scientific knowledge and future preparation, and (4) to detect changes or anomalies in contaminant mobility (if they occur), or any unexpected processes or events. In this work, we have developed a methodology for optimizing the sampling locations of radiation air dose-rate monitoring. Three steps are taken in order to determine sampling locations in a systematic manner: (1) prioritizing the critical locations, such as schools or regulatory requirement locations, (2) diversifying locations across the key environmental controls that are known to influence contaminant mobility and distributions, and (3) capturing the heterogeneity of radiation air dose rates across the domain. In the second step, we use a Gaussian mixture model to identify the representative locations in multiple environmental variables, such as elevation and land-cover types. In the third step, we use a Gaussian process model to capture and estimate the heterogeneity of air dose rates across the domain. We use the integrated dose-rate map from the Bayesian geostatistical method as the reference map and distribute the sampling in such a way as to capture the heterogeneity of the reference map. Although we assume hypothetical sets of measurement locations to evaluate the performance of the methodology and algorithms, we have demonstrated this approach using real, spatially extensive datasets, including the integrated air-dose-rate map of 2016. Our results have shown that this approach allows us to add sampling locations in a systematic manner. Increasing the number of sampling locations can better capture the heterogeneity of dose rates, although the estimation error does not decrease further after a certain number of samples. We have also found that when there are restrictions such as pre-existing monitoring locations or the ones along roads, the spatial estimation becomes poor even with the same number of monitoring locations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗