Search NASA⌕ Search

SEARCH · Search NASA

Results for “Application Tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Smart Sensor Demonstration Payload

Sensors are a critical element to any monitoring, control, and evaluation processes such as those needed to support ground based testing for rocket engine test. Sensor applications involve tens to thousands of sensors; their reliable performance is critical to achieving overall system goals. Many figures of merit are used to describe and evaluate sensor characteristics; for example, sensitivity and linearity. In addition, sensor selection must satisfy many trade-offs among system engineering (SE) requirements to best integrate sensors into complex systems [1]. These SE trades include the familiar constraints of power, signal conditioning, cabling, reliability, and mass, and now include considerations such as spectrum allocation and interference for wireless sensors. Our group at NASA s John C. Stennis Space Center (SSC) works in the broad area of integrated systems health management (ISHM). Core ISHM technologies include smart and intelligent sensors, anomaly detection, root cause analysis, prognosis, and interfaces to operators and other system elements [2]. Sensor technologies are the base fabric that feed data and health information to higher layers. Cost-effective operation of the complement of test stands benefits from technologies and methodologies that contribute to reductions in labor costs, improvements in efficiency, reductions in turn-around times, improved reliability, and other measures. ISHM is an active area of development at SSC because it offers the potential to achieve many of those operational goals [3-5].

Schmalzel, John↗

Interior noise control ground test studies for advanced turboprop aircraft applications

The measurement and analysis procedures are documented, and the results of interior noise control ground tests conducted on a DC-9 aircraft test section are summarized. The objectives of these tests were to study the fuselage response characteristics of treated and untreated aircraft with aft-mount advanced turboprop engines and to analyze the effectiveness of selected noise control treatments in reducing passenger cabin noise on these aircraft. The results of fuselage structural mode surveys, cabin cavity surveys and sound intensity surveys are presented. The performance of various structural and cabin sidewall treatments is assessed, based on measurements of the resulting interior noise levels under simulated advanced turboprop excitation.

Simpson, Myles A.↗

Comparison of toughened composite laminates using NASA standard damage tolerance tests

The proposed application of composite materials to transport wing and fuselage structures prompted the search for tougher materials having improved resistance to impact damage and delamination. Several resin/graphite fiber composite materials were subjected to standard damage tolerance tests and the results were compared to ascertain which materials have superior toughness. In addition, test results from various company and NASA laboratories were compared for repeatability.

Williams, J. G.↗

The 1991 AVIRIS/POLDER experiment in Camargue, France

Airborne campaigns during the eighties provided high spectral resolution data, collected with imaging instruments such as AIS, AVIRIS, FLI, CAESI, and ISM, in order to investigate the relationship with canopy biophysical characteristics. The statistical approaches used to analyze these data do not allow investigation of the causality and the applicability of the observed correlations. Further, statistical studies demonstrated the high degree of redundancy of the spectral information amongst many others. And for retrieving vegetation biophysical characteristics, few results demonstrate the real information gain attributable to the high spectral resolution capability as compared to the use of a few wide wavelength bands. With several new imaging spectrophotometers scheduled for launch during the next 10 years (MERIS, MODIS, HIRIS), progress in the description and understanding of the mechanisms that drive the spectral variation of canopy reflectance is required. Most of these new sensor systems will also have the capability to observe the target under differing view directions. The problem of the combination and the use of the synergy between both the spectral and the directional sources of canopy reflectance variations has to be addressed. Apart from the atmospheric effects, the spectral variation of the light reflected by canopies originates from the leaves, the soil or the other vegetation elements such as branches and fruits. At leaf level, both diffuse reflectance and transmittance may be simulated by simple models, although no accurate information exists on the absorption features of the biochemicals (except water) in the 900-2500nm wavelength range. Many models mimic the directional variability of canopy reflectance at a given wavelength. Combining a leaf spectral model with a canopy directional model provides a powerful tool to analyze this problem. Some of us have initiated such a study, but our approach and theory remain to be tested using canopy data with their complexity, associated experimental error, and atmospheric effects. The main objective of the 1990 POLDER/AVIRIS experiment in Camargue was to provide a consistent data set over various canopies in order to test the applicability of the theory. The experiment, part of the 1991 MAC Europe experiment, involved simultaneous data collection using two sensors: AVIRIS and POLDER which measures the bidirectional and polarization properties of the targets at 670 and 880nm wavebands.

Baret, F.↗

Elevated Temperature Ballistic Impact Testing of PBO and Kevlar Fabrics for Application in Supersonic Jet Engine Fan Containment Systems

Ballistic impact tests were conducted on fabric made from both Poly(phenylene benzobizoxazole) (PBO) and Kevlar 29 which were selected to be similar in weave pattern, areal density, and fiber denier. The projectiles were 2.54-cm- (1-in.-) long aluminum cylinders with a diameter of 1.27 cm (0.5 in.). The fabric specimens were clamped on four sides in a 30.5-cm- (12-in.-) square frame. Tests on PBO were conducted at room temperature and at 260 C (500 F). A number of PBO specimens were aged in air at 204 and 260 C (400 and 500 F) before impact testing. Kevlar specimens were tested only at room temperature and with no aging. The PBO absorbed significantly more energy than the Kevlar at both room and elevated temperatures. However, after aging at temperatures of 204 C (400 F) and above, the PBO fabric lost almost all of its energy absorbing ability. It was concluded that PBO fabric is not a feasible candidate for fan containment system applications in supersonic jet engines where operating temperatures exceed this level.

Pereira, J. Michael↗

The Genesis Non-flight Implant Sample Archive

Introduction: For the past 20 years the Genesis science community has been analyzing solar wind captured in sample collectors now curated at Johnson Space Center (JSC). Non-flown flight like collector materials (non-flight) considered reference material was always allocated by the JSC Genesis team for testing experimental procedures. However, to expedite Genesis science, distribution of non-flown reference materials were also provided by, D. S. Burnett (Genesis PI, Caltech) and A. J. G. Jurewicz (ASU) who were funded to aid all Genesis PIs by providing engineering test materials archived at Caltech pre-flight as well as ion implants into these materials [1]. Implanted materials (non-flight reference, flight-like semiconductor materials, and NIST SRM glass) received from the Caltech collection during a pilot project are being used to develop an accession procedure for the purpose of making these materials available to researchers in the future. These implant samples are important because they can be utilized as measurement standards [2]. This is a work in progress and this work reports progress in documentation and imaging. The pilot program received 63 implanted reference materials with known implanted ions. Genesis Non-Flight Database: The existing non-flight material database was modified to allow for the description of implant sessions and to allow correlation of the implant information to individual specimens. An implant session has three main components: a known ion, a known dose (ion/cm2), and a known energy (keV). Procedure: Laboratory Procedure. Upon receiving non-flight analytical standards (independently calibrated implants), or implant samples (nominally calibrated implants), they will be imaged in their current containers to capture any information written before being brought into the Genesis Sample Laboratory. Documentation is provided by the donor and used for correlating the data between the implant sessions and implant samples. This information is not verified by Genesis Curation. The microscope used to image samples in the laboratory has an automated stage with a stainless-steel plate to hold samples and a camera that utilizes the software Surveyor to take photomosaic images of the implant samples. The camera attached to the microscope is a QICAM High Performance IEEE 1394 FireWire Digital CCD Camera. This setup, shown in Fig. 1, allows for photomosaics of small-scale samples with a 10x objective or 25x objective. Examples of images taken with this microscope setup are shown in Fig.2 and Fig. 3. After imaging, samples get stored in a clean fluoroware container or polypropylene vial depending on sample size for long term storage. Database Procedure. The Genesis Non-Flight Database currently allows for the addition of implant sessions. The required fields for adding an implant session are the implant session ion, the implant session dose, and the implant session energy. There are also fields for the date and vendor of the sessions as well as a field for if the session was calibrated or not. Once an implant session has been inserted into the database, additional documentation from the session can be attached. The database will automatically assign an Implant Session Number. After inserting an implant session, the implanted samples can be inserted. The fields required for an implant sample are the material of the sample and the size of the sample. The Generic name for the implant sample with be automatically generated by the database once it has been inserted. Implant sample numbers begin with 3X to distinguish from flown Genesis sample numbers. There are also fields for processors to add the location (room, cabinet, tray) and container type (fluoroware, polypropylene vial). Once an implant session and an associated sample(s) have been inserted into the database the sample can be then tied to all associated implant sessions. An implant sample can be tied to multiple implant sessions. Future work: For curation, future work consists of creating an online catalogue for implant samples as well as updating the database with more samples as we receive them. For the scientific community these implant samples have many potential uses. For Genesis research, they are directly applicable for testing and, in some cases, as analytical standards. For non-Genesis research, implants (especially calibrated implants) could be used for calibrating other, unique planetary materials [1].

C D Calva↗

Training manuals for nondestructive testing using magnetic particles

Training manuals containing the fundamentals of nondestructive testing using magnetic particle as detection media are used by metal parts inspectors and quality assurance specialists. Magnetic particle testing involves magnetization of the test specimen, application of the magnetic particle and interpretation of the patterns formed.

Source record↗

Solid propellant engineering

Surface temperature relations for ignition material deflagration onset, and static tests of Applications Technology Satellite motor

Source record↗