Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building performance simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

A new surrogate modeling technique combining Kriging and polynomial chaos expansions – Application to uncertainty analysis in computational dosimetry

In numerical dosimetry, the recent advances in high performance computing led to a strong reduction of the required computational time to assess the specific absorption rate (SAR) characterizing the human exposure to electromagnetic waves. However, this procedure remains time-consuming and a single simulation can request several hours. As a consequence, the influence of uncertain input parameters on the SAR cannot be analyzed using crude Monte Carlo simulation. The solution presented here to perform such an analysis is surrogate modeling. This paper proposes a novel approach to build such a surrogate model from a design of experiments. Considering a sparse representation of the polynomial chaos expansions using least-angle regression as a selection algorithm to retain the most influential polynomials, this paper proposes to use the selected polynomials as regression functions for the universal Kriging model. The leave-one-out cross validation is used to select the optimal number of polynomials in the deterministic part of the Kriging model. The proposed approach, called LARS-Kriging-PC modeling, is applied to three benchmark examples and then to a full-scale metamodeling problem involving the exposure of a numerical fetus model to a femtocell device. The performances of the LARS-Kriging-PC are compared to an ordinary Kriging model and to a classical sparse polynomial chaos expansion. The LARS-Kriging-PC appears to have better performances than the two other approaches. A significant accuracy improvement is observed compared to the ordinary Kriging or to the sparse polynomial chaos depending on the studied case. This approach seems to be an optimal solution between the two other classical approaches. A global sensitivity analysis is finally performed on the LARS-Kriging-PC model of the fetus exposure problem.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Final Energy Savings Analysis of the Proposed NYStretch-Energy Code 2018

In 2017, New York State Energy Research and Development Authority (NYSERDA) developed its 2016 Stretch Code Supplement to the 2016 New York State Energy Conservation Construction Code. Since2017, NYSERDA has continued to develop the 2018 edition, as part of the efforts to achieve a statewide Net Zero Energy Code by 2028. To support this effort, Pacific Northwest National Laboratory (PNNL)conducted energy simulation analysis to quantify the energy savings of proposed commercial provisions of the NYStretch-Energy Code 2018 compared to ANSI/ASHRAE/IES1 Standard 90.1-2013. Specifically, PNNL collaborated with New Buildings Institute (NBI), and developed energy-efficiency measures (EEMs) from national model codes and standards, high-performance building codes and standards, regional energy codes, and measures being proposed as part of the ongoing NYStretch-Energy code development process. PNNL analyzed these measures using whole building energy simulation for selected prototype commercial and multifamily buildings representing buildings in New York State.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Final Energy Savings Analysis of the Proposed NYStretch-Energy Code 2018

In 2017, New York State Energy Research and Development Authority (NYSERDA) developed its 2016 Stretch Code Supplement to the 2016 New York State Energy Conservation Construction Code. Since 2017, NYSERDA has continued to develop the 2018 edition, as part of the efforts to achieve a statewide Net Zero Energy Code by 2028. To support this effort, Pacific Northwest National Laboratory (PNNL) conducted energy simulation analysis to quantify the energy savings of proposed commercial provisions of the NYStretch-Energy Code 2018 compared to ANSI/ASHRAE/IES1 Standard 90.1-2013. Specifically, PNNL collaborated with New Buildings Institute (NBI), and developed energy-efficiency measures (EEMs) from national model codes and standards, high-performance building codes and standards, regional energy codes, and measures being proposed as part of the ongoing NYStretch-Energy code development process. PNNL analyzed these measures using whole building energy simulation for selected prototype commercial and multifamily buildings representing buildings in New York State. This report describes the analysis methodology, explains detailed specifications of the EEMs, and summarizes the results of individual EEMs and EEM bundles by building type and climate zone. As shown in Figure ES.1, significant energy saving could be achieved by adopting the NYStretch-Energy Code 2018.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Micro-Environmental Control System (Final Report)

This project developed an innovative micro-environmental control system (µX) that enables office buildings to reduce energy used for heating and cooling by 15% or more. The µX is a compact, quiet, and ergonomic device that is designed to be installed under an office workstation; it is designed to maintain occupant comfort when room thermostat setpoints are incremented by 4°F or more (warmer in the summer and cooler in the winter) to save energy. When ambient room temperatures are outside of the usual comfort range, the µX maintains occupant comfort by delivering personalized cooling or heating locally to each office worker. The µX provides personalized cooling using a micro vapor compression system that includes a new high-performance micro-scroll compressor and a novel thermal storage unit. The vapor compression system operates at night to freeze a phase-change material (PCM). During the workday, the cooling stored in the PCM is released as a cool breeze of air to make occupants more comfortable. The micro-scroll compressor was developed specifically for this application; it is smaller than any of its type, minimizing the amount of power needed. In heating mode, the µX maintains occupant comfort using a foot heating mat with an infrared reflective box. The µX R&D project was conducted by Syracuse University in collaboration with United Technologies Research Center, Air Innovations, Bush Technical, and Cornell University. Over the course of the initial three-year project, the team developed and evaluated four versions of the unit, advancing the concept to Technology Readiness Level 6. The capabilities of individual proof-of-concept prototypes were verified in tests that were conducted with: 1) units in psychrometric chambers, 2) an instrumented manikin in a laboratory, and 3) human subjects in laboratories that simulate office environments. The tests verified that the µX prototypes met or exceeded all performance targets required to enable office buildings to reduce energy used for heating and cooling by 15% or more by maintaining occupant comfort when thermostat setpoints are incremented by 4°F or more.

25 ENERGY STORAGE↗

Scenario Analysis of Peak Demand Savings for Commercial Buildings with Thermal Mass in California

This paper reports on the potential impact of demand response (DR) strategies in commercial buildings in California based on the Demand Response Quick Assessment Tool (DRQAT), which uses EnergyPlus simulation prototypes for office and retail buildings. The study describes the potential impact of building size, thermal mass, climate, and DR strategies on demand savings in commercial buildings. Sensitivity analyses are performed to evaluate how these factors influence the demand shift and shed during the peak period. The whole-building peak demand of a commercial building with high thermal mass in a hot climate zone can be reduced by 30percent using an optimized demand response strategy. Results are summarized for various simulation scenarios designed to help owners and managers understand the potential savings for demand response deployment. Simulated demand savings under various scenarios were compared to field-measured data in numerous climate zones, allowing calibration of the prototype models. The simulation results are compared to the peak demand data from the Commercial End-Use Survey for commercial buildings in California. On the economic side, a set of electricity rates are used to evaluate the impact of the DR strategies on economic savings for different thermal mass and climate conditions. Our comparison of recent simulation to field test results provides an understanding of the DR potential in commercial buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spawn v.0.5.0 Released 12.15.2023 [SWR-SWR-20-10]

Spawn is a software package for performing co-simulations involving NREL's EnergyPlus™ tool and Modelica. This package bundles the following items in one self-contained package. 1. A method for connecting EnergyPlus models to Modelica 2. A Modelica compiler toolchain for compiling and running Modelica models 3. Modelica libraries and content, including the Modelica Buildings Library (MBL) and the Modelica Standard Library. The Spawn installation package is fully self-contained, and there are no external third-party dependencies. Together the capabilities in this package provide a single integrated environment for performing hybrid Modelica and EnergyPlus simulations. The primary entry point is the Spawn command line interface.

Li, Yanfei↗

IoT-based retrofit information diffusion in future smart communities

Community-scale building retrofits are not merely scaled-up versions of single-building retrofits. They involve complex challenges, such as reconciling individual interests with collective goals and managing the dynamic interplay between buildings through mechanisms like power grids and social connections. Internet of Things (IoT) connectivity holds the potential to leverage these interplays to balance individual and collective interests effectively in smart communities. One critical aspect of this interplay is information diffusion, which shapes how retrofit decisions spread among neighbors, influencing individual choices and ultimately impacting community-level retrofit outcomes. In other words, IoT-based smart devices automatically push tailored retrofit notifications to homeowners, which completely changes the format of information diffusion in the future. To investigate this influence by such information diffusion, the study used CityBES to simulate energy performance for different retrofits and applied an information diffusion model to analyze how decisions spread in a networked community of 192 buildings. The diffusion process was modeled on a weighted, directed network, capturing the dynamics of information flow and decision-making across 16 scenarios. Individual retrofit benefits were evaluated through payback years, while community-level retrofit outcomes were assessed using greenhouse gas (GHG) emission reductions. The results demonstrate that easier information diffusion among neighbors encourages households to prioritize retrofit measures that align with the majority’s optimal choices, even at the expense of individual financial benefits. In this case, such collective prioritization enhanced community-level retrofit performance, increasing GHG emission reductions by up to 29.4 %. However, this improvement came with trade-offs, as the average payback period for households extended by approximately 1.74 years. These findings highlight the potential of IoT-based information diffusion in future smart communities to coordinate individual interests with collective goals, ultimately accelerating community-level building retrofits.

Shu, Lei↗

Analyzing the Life Cycle Energy Savings of DOE Supported Buildings Technologies

This report examines the factors that would potentially help determine an appropriate analytical timeframe for measuring the U.S. Department of Energy's Building Technology (BT) benefits and presents a summary-level analysis of the life cycle savings for BT’s Commercial Buildings Integration (CBI) R&D program. The energy savings for three hypothetical building designs are projected over a 100-year period using Building Energy Analysis and Modeling System (BEAMS) to illustrate the resulting energy and carbon savings associated with the hypothetical aging buildings. The report identifies the tasks required to develop a long-term analytical and modeling framework, and discusses the potential analytical gains and losses by extending an analysis into the “long-term.”

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

AerChemMIP: Quantifying the effects of chemistry and aerosols in CMIP6

The Aerosol Chemistry Model Intercomparison Project (AerChemMIP) is endorsed by the Coupled-Model Intercomparison Project 6 (CMIP6) and is designed to quantify the climate and air quality impacts of aerosols and chemically reactive gases. These are specifically near-term climate forcers (NTCFs: methane, tropospheric ozone and aerosols, and their precursors), nitrous oxide and ozone-depleting halocarbons. The aim of AerChemMIP is to answer four scientific questions. 1. How have anthropogenic emissions contributed to global radiative forcing and affected regional climate over the historical period? 2. How might future policies (on climate, air quality and land use) affect the abundances of NTCFs and their climate impacts? 3.How do uncertainties in historical NTCF emissions affect radiative forcing estimates? 4. How important are climate feedbacks to natural NTCF emissions, atmospheric composition, and radiative effects? These questions will be addressed through targeted simulations with CMIP6 climate models that include an interactive representation of tropospheric aerosols and atmospheric chemistry. These simulations build on the CMIP6 Diagnostic, Evaluation and Characterization of Klima (DECK) experiments, the CMIP6 historical simulations, and future projections performed elsewhere in CMIP6, allowing the contributions from aerosols and/or chemistry to be quantified. As a result, specific diagnostics are requested as part of the CMIP6 data request to highlight the chemical composition of the atmosphere, to evaluate the performance of the models, and to understand differences in behaviour between them.

54 ENVIRONMENTAL SCIENCES↗

Cloud-Based Model Calibration Using OpenStudio: Preprint

OpenStudio is a free, open source Software Development Kit (SDK) and application suite for performing building energy modeling and analysis. The OpenStudio Parametric Analysis Tool has been extended to allow cloud-based simulation of multiple OpenStudio models parametrically related to a baseline model. This paper describes the new cloud-based simulation functionality and presents a model cali-bration case study. Calibration is initiated by entering actual monthly utility bill data into the baseline model. Multiple parameters are then varied over multiple iterations to reduce the difference between actual energy consumption and model simulation results, as calculated and visualized by billing period and by fuel type. Simulations are per-formed in parallel using the Amazon Elastic Cloud service. This paper highlights model parameterizations (measures) used for calibration, but the same multi-nodal computing architecture is available for other purposes, for example, recommending combinations of retrofit energy saving measures using the calibrated model as the new baseline.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CLIMATE-SPECIFIC MODELING AND ANALYSIS FOR BEST-PRACTICE INDIAN OFFICE BUILDINGS

This paper describes the methodology and results of building energy modeling to validate and quantify the energy savings from conservation measures in medium-sized office buildings in four different climate zones in India. We present the different energy measures and their expected and simulated performances and discuss the results and the influence of climate.

Singh, Reshma↗

OpenStudio® Energy Rating Index (ERI) Workflow (SWR-18-72)

The OpenStudio®-ERI project allows calculating an Energy Rating Index (ERI) using the Department of Energy's open-source OpenStudio®/EnergyPlus® simulation platform. The building description is provided in an HPXML file format. The project supports: - ANSI/RESNET/ICC 301© Standard for the Calculation and Labeling of the Energy Performance of Dwelling and Sleeping Units using an Energy Rating Index - ENERGY STAR Certification System for Homes and Apartments Using an ERI Compliance Path - IECC ERI Compliance Alternative (Section R406) - DOE ZERH Certification Using an ERI Compliance Path For more information on running simulations, generating HPXML files, etc., please visit the documentation at https://openstudio-eri.readthedocs.io/en/latest/

Horowitz, Scott↗

OpenStudio®-ERI (Energy Rating Index (ERI) Workflow) [SWR-18-72] 1.7.0 Released 12/14/2023

The OpenStudio®-ERI project allows calculating an Energy Rating Index (ERI) using the Department of Energy's open-source OpenStudio®/EnergyPlus® simulation platform. The building description is provided in an HPXML file format. The project supports: - ANSI/RESNET/ICC 301© Standard for the Calculation and Labeling of the Energy Performance of Dwelling and Sleeping Units using an Energy Rating Index - ENERGY STAR Certification System for Homes and Apartments Using an ERI Compliance Path - IECC ERI Compliance Alternative (Section R406) - DOE ZERH Certification Using an ERI Compliance Path For more information on running simulations, generating HPXML files, etc., please visit the documentation at https://openstudio-eri.readthedocs.io/en/latest/

Horowitz, Scott↗

Building envelope anomaly characterization and simulation using drone time-lapse thermography

Defects in building envelopes deteriorate over time without being visible to the human eye, while significantly impacting energy performance due to unaccounted heat transfer. Defects can be characterized in the infrared (IR) spectrum. However, IR readings are typically recorded at singular points in time, when in several cases anomalies can only be revealed at specific times of the day, possibly in different seasons of the year. This paper presents a novel workflow for 3D envelope defect characterization and modeling using aerial time-lapse IR data collection using drones. A comprehensive envelope thermal profile is developed for a case study building employing the photogrammetry software Agisoft Photoscan, which generates temporal IR inspections of building skins using multiple thermography orthomosaics. Point-cloud data is then translated into a CAD model and thermal zones for whole Building Energy Modeling (BEM) using Honeybee as a frontend to EnergyPlus to showcase the potential of inclusion of detailed 4D data. Envelope contributions in this case study’s anomalies showed heat losses of 6447.6 kWh, and Energy Use Intensity (EUI) differences of ~2 kWh/m 2 /year from the baseline. Finally, why there is currently little translation of this work in BEM software is discussed, while identifying limitations and future research in the employment of time-lapse thermography using drones for more accurate building envelope inspection and modeling.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficiency of Distributed Environmental Control Systems

In this report, we present an analytical evaluation of the potential of occupant-regulated distributed environmental control systems (DECS) to enhance individual occupant thermal comfort in an office building with no increase, and possibly even a decrease in annual energy consumption. To this end we developed and applied several analytical models that allowed us to optimize comfort and energy consumption in partitioned office buildings equipped with either conventional central HVAC systems or occupant-regulated DECS. Our approach involved the following interrelated components: 1. Development of a simplified lumped-parameter thermal circuit model to compute the annual energy consumption. This was necessitated by the need to perform tens of thousands of optimization calculations involving different US climatic regions, and different occupant thermal preferences of a population of ~50 office occupants. Yearly transient simulations using TRNSYS, a time-dependent building energy modeling program, were run to determine the robustness of the simplified approach against time-dependent simulations. The simplified model predicts yearly energy consumption within approximately 0.6% of an equivalent transient simulation. Simulations of building energy usage were run for a wide variety of climatic regions and control scenarios, including traditional “one-size-fits-all” (OSFA) control; providing a uniform temperature to the entire building, and occupant-selected “have-it-your-way” (HIYW) control with a thermostat at each workstation. The thermal model shows that, un-optimized, DECS would lead to an increase in building energy consumption between 3-16% compared to the conventional approach depending on the climate regional and personal preferences of building occupants. Variations in building shape had little impact in the relative energy usage. 2. Development of a gradient-based optimization method to minimize energy consumption of DECS while keeping each occupant’s thermal dissatisfaction below a given threshold. The DECS energy usage was calculated using the simplified thermal model. OSFA control; providing a uniform temperature to the entire building, and occupant-selected HIYW control with a thermostat at each workstation were implemented for 3 cities representing 3 different climatic regions and control scenarios. It is shown that optimization allows DECS to deliver a higher level of individual and population thermal comfort while achieving annual energy savings between 14 and 26% compared to OSFA. The optimization model also allowed us to study the influence of the partitions’ thermal resistance and the variability of internal loads at each office. These influences didn’t make significant changes in the optimized energy consumption relative to OSFA. The results show that it is possible to provide thermal comfort for each occupant while saving energy compared to OSFA Furthermore, to simplify the implementation of this approach, a fuzzy logic system has been developed to generalize the overall optimization strategy. Its performance was almost as good as the gradient system. The fuzzy system provided thermal comfort to each occupant and saved energy compared to OSFA. The energy savings of the fuzzy system were not as high as for the gradient-optimized system, but the fuzzy system avoided complete connectivity, and the optimization did not have to be repeated for each population. 3. We employed a detailed CFD model of adjacent occupied cubicles to extend the thermal-circuit model in three significant ways: (a) relax the “office wall” requirement by allowing energy to flow between zones via advection as well as conduction, (b) improve the comfort model to account both for radiation as well as convection heat transfer, and (c) support ventilation systems in which the temperature is stratified, such as in underfloor air distribution systems. Initially, three-dimensional CFD simulations of several cubicle configurations, with an adjoining corridor, were performed both to understand the advection between cubicles and the resulting temperature stratification. These simulations showed that the advective flow between cubicles is very significant and severely limits the occupants’ ability to control the personal micro-environments by simply controlling the temperature of the incoming air. Subsequently, the existing thermal-circuit model was extended to include the phenomena described above. The modifications to the thermal-circuit model, which were incorporated such that the simulation time was only slightly impacted, showed that accounting for room stratification resulting from the use of floor swirl diffusers could lead to 10%-26% reduction in the annual energy consumed for HVAC in non-temperate climates. This trend was evident in both OSFA and HIYW scenarios. However, the ratio of energy usage in the two scenarios was little affected by the enhancements in the thermal model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cutting the Deployment Costs of Physics-Based MPC in Buildings by Simulation-Based Imitation Learning

It has been shown that model predictive control (MPC) is a promising solution for energy-efficient building operations. However, the deployment of MPC in a large portion of the building stock has not been possible partially because of high installation costs. Every building is unique and requires a tailored MPC solution. The best performing solutions are often based on physics-based modeling, which is, however, computationally expensive and requires dedicated software. A promising direction that tackles this problem is to train a neural network-based optimal control policy to imitate the behavior of physics-based MPC from the simulation data generated offline. The neural networks give control actions that closely approximate those produced by physics-based MPC, but with a fraction of the computational and memory requirements and without the need for licensed software. The main advantage of the proposed approach stems from simple evaluation at execution time, leading to low computational footprints and easy deployment on embedded HW platforms. In the case study, we present the energy savings potential of physics-based MPC applied to an office building in Belgium. We demonstrate how neural network approximators can be used to cut the implementation and maintenance costs of MPC deployment without compromising performance. We also critically assess the presented approach by pointing out the remaining challenges and open research questions.

Drgona, Jan↗

Simulated Performance of the Integrated PNAR and SINRD Detector Designed for Spent Fuel Measurements at the Fugen Reactor in Japan

Objective is to investigate the use of Passive Neutron Albedo Reactivity (PNAR) and Self-Interrogation Neutron Resonance Densitometry (SINRD) to quantify fissile content in FUGEN spent fuel assemblies (FAs). Methodology used is: (1) Detector was designed using fission chambers (FCs); (2) Optimized design via MCNPX simulations; and (3) Plan to build and field test instrument in FY13. Significance was to improve safeguards verification of spent fuel assemblies in water and increase sensitivity to partial defects. MCNPX simulations were performed to optimize the design of the SINRD+PNAR detector. PNAR ratio was less sensitive to FA positioning than SINRD and SINRD ratio was more sensitive to Pu fissile mass than PNAR. Significance was that the integration of these techniques can be used to improve verification of spent fuel assemblies in water.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Making inertial confinement fusion models more predictive

Computer models of inertial confinement fusion (ICF) implosions play an essential role in experimental design and interpretation as well as our understanding of fundamental physics under the most extreme conditions that can be reached in the laboratory. Building truly predictive models is a significant challenge, with the potential to greatly accelerate progress to high yield and ignition. One path to more predictive models is to use experimental data to update the underlying physics in a way that can be extrapolated to new experiments and regimes. We describe a statistical framework for the calibration of ICF simulations using data collected at the National Ignition Facility (NIF). We perform Bayesian inferences for a series of laser shots using an approach that is designed to respect the physics simulation as much as possible and then build a second model that links the individual-shot inferences together. We show that this approach is able to match multiple X-ray and neutron diagnostics for a whole series of NIF “BigFoot” shots. Within the context of 2D radiation hydrodynamic simulations, our inference strongly favors a significant reduction in fuel compression over other known degradation mechanisms (namely, hohlraum issues and engineering perturbations). This analysis is expanded using a multifidelity technique to pick fuel-ablator mix from several candidate causes of the degraded fuel compression (including X-ray preheat and shock timing errors). Finally, we use our globally calibrated model to investigate the extra laser drive energy that would be required to overcome the inferred fuel compression issues in NIF BigFoot implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗