Search NASA⌕ Search

SEARCH · Search NASA

Results for “CALIBRATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Absolute radiometric calibration of advanced remote sensing systems

The distinction between the uses of relative and absolute spectroradiometric calibration of remote sensing systems is discussed. The advantages of detector-based absolute calibration are described, and the categories of relative and absolute system calibrations are listed. The limitations and problems associated with three common methods used for the absolute calibration of remote sensing systems are addressed. Two methods are proposed for the in-flight absolute calibration of advanced multispectral linear array systems. One makes use of a sun-illuminated panel in front of the sensor, the radiance of which is monitored by a spectrally flat pyroelectric radiometer. The other uses a large, uniform, high-radiance reference ground surface. The ground and atmospheric measurements required as input to a radiative transfer program to predict the radiance level at the entrance pupil of the orbital sensor are discussed, and the ground instrumentation is described. Previously announced in STAR as N83-28544

Slater, P. N.↗

Results of the first complete static calibration of the RSRA rotor-load-measurement system

The compound Rotor System Research Aircraft (RSRA) is designed to make high-accuracy, simultaneous measurements of all rotor forces and moments in flight. Physical calibration of the rotor force- and moment-measurement system when installed in the aircraft is required to account for known errors and to ensure that measurement-system accuracy is traceable to the National Bureau of Standards. The first static calibration and associated analysis have been completed with good results. Hysteresis was a potential cause of static calibration errors, but was found to be negligible in flight compared to full-scale loads, and analytical methods have been devised to eliminate hysteresis effects on calibration data. Flight tests confirmed that the calibrated rotor-load-measurement system performs as expected in flight and that it can dependably make direct measurements of fuselage vertical drag in hover.

Acree, C. W., Jr.↗

Information for space radar designers: Required dynamic range vs resolution and antenna calibration using the Amazon rain forest

Calibration of the vertical pattern of the antennas for the SEASAT scatterometer was accomplished using the nearly-uniform radar return from the Amazon rain forest. A similar calibration will be attempted for the SIR-B antenna. Thick calibration is important to establish the radiometric calibration across the swath of the SIR-B, and the developed methodology will provide an important tool in the evaluation of future spaceborne imaging radars. This calibration was made by the very-wide-beam SEASAT scatterometer antennas because at 14.65 GHz the scattering coefficient of the rain forest is almost independent of angle of incidence. It is expected that the variation in scattering coefficient for the rain forest across the relatively narrow vertical beam of the SIR-B will be very small; even at L band the forest should be essentially impenetrable for radar signals, the volume scatter from the treetops will predominate as at higher frequencies. The basic research elements include: (1) examination of SIR-B images over the rain forest to establish the variability of the scattering coefficient at finer resolutions than that of the SEASAT scatterometer; (2) analysis of the variability of SIR-B data detected prior to processing for either azimuth compression or; possibly, range compression so that averages over relatively large footprints can be used; (3) processing of data of the form of (2) using algorithms that can recover the vertical pattern of the antenna.

Moore, R. K.↗

LANDSAT-4 Thematic Mapper Calibration and Atmospheric Correction

The LANDSAT-4 thematic mapper, with its wide spectral coverage and digitization to 8 bits per word, is a large step forward in the direction of quantitative radiometry from the multispectral scanner (MSS). In order to utilize the quantitative accuracy built into the thematic mapper effectively, more attention must be paid to calibration before launch, changes of calibration with time in orbit, and atmospheric interference with the measurements, especially in the 450 to 520 nanometer band. Experience with the coastal zone color scanner (CZCS) program led to procedures wherein Rayleigh correction factors can be generated utilizing simultaneous surface truth data that empirically give correct upwelled surface radiances, despite errors in sensor calibration, solar spectral irradiance measurements, and reported values of Rayleigh optical depth. These techniques offer sensitive tests for change in calibration, especially at shorter wavelengths. Instruments, such as the CZCS, have shown that calibration changes first, and to the largest degree, at the shorter wavelengths, with lesser changes as wavelength increases. These techniques are utilized to calculate a Rayleigh correction factor that, together with geometric terms, should give an accurate correction for this portion of the atmospheric contribution to the signal.

Hovis, W. A.↗

A review of some radiometric calibration problems and methods

The in-flight radiometric calibration instrumentation and procedures of the Landsat Thematic Mapper and the high-resolution visible-range instruments of SPOT are illustrated with drawings and diagrams, characterized, and compared. Problems encountered in the laboratory calibration process, minimizing the temporal instability of the systems, identifying anomalies in the electronics in flight, and rechecking the calibration are examined, and it is pointed out that the stability of the calibration systems is less than that of the instruments themselves. The use of carefully measured ground-site data and atmospheric parameters in combination with radiative-transfer models for periodic calibration is recommended.

Slater, P. N.↗

Absolute calibration of photometry at 1 through 5 microns

The solar-analog method is used to determine the absolute calibration of photometry in the J, H, K, L, and M bands to an accuracy of 3 percent, (5 percent at M). This calibration agrees well with the direct calibration obtained by Blackwell et al. (1983); this agreement gives confidence that the calibration is known to an accuracy of 2 percent to 3 percent. The agreement also implies that the behavior of solar type stars is well understood in the infrared and that such stars make reliable standards for calibration of nonstandard photometric bands and for planetary reflectance studies. Both methods indicate that Vega is slightly brighter than indicated by atmospheric models.

Campins, H.↗

Lidar aerosol backscatter measurements - Systematic, modeling, and calibration error considerations

Sources of systematic, modeling, and calibration errors that affect the interpretation and calibration of lidar aerosol backscatter data are discussed. The treatment pertains primarily to ground-based pulsed CO2 lidars that probe the troposphere and are calibrated using hard calibration targets. However, a large part of the analysis is relevant to other types of lidar system such as lidars operating at other wavelengths; CW focused lidars; airborne or earth-orbiting lidars; lidars measuring other regions of the atmosphere; lidars measuring nonaerosol elastic or inelastic backscatter; and lidars employing other calibration techniques.

Kavaya, M. J.↗

Calibration of satellite sensors after launch

A simple and accurate method for the postflight calibration of satellite Visible Infrared Spin-Scan Radiometers (VISSR) is presented, and the results of inflight testing are reported. The calibration source for the VISSR with its effective wavelength of 610 nm is the radiance of sunlight, measured in calibrated reflectance units, scattered by the atmospheric gas above ocean which is far from land. Only the lowest 20 percent of the full-scale VISSR response is calibrated. VISSR testing aboard two geostationary operational evironmental satellites between 1980 and 1983 showed significant calibration coefficient variations of only + or - 12 percent and + or - 2 percent. Good agreement was found between values of aerosol optical thickness measured by VISSR and those measured from the ground.

Fraser, R. S.↗

Supplementary calibration test of the tip-aerodynamics- and acoustics-test pressure transducers

A calibration test is described that was performed to supplement the normal calibration of the 188 pressure transducers used in the Tip Aerodynamics and Acoustics Test. This calibration led to the identification of 15 transducers which had a slope change of greater than 7% from the initial calibration. The calibration procedure is described and the results presented. The effect of the slope changes on the pressure distributions are described, followed by a method to compensate for these changes.

Watts, M. E.↗

Calibration and comparison of the NASA Lewis free-piston Stirling engine model predictions with RE-1000 test data

A free-piston Stirling engine performance code is being upgraded and validated at the NASA Lewis Research Center under an interagency agreement between the Department of Energy's Oak Ridge National Laboratory and NASA Lewis. Many modifications were made to the free-piston code in an attempt to decrease the calibration effort. A procedure was developed that made the code calibration process more systematic. Engine-specific calibration parameters are often used to bring predictions and experimental data into better agreement. The code was calibrated to a matrix of six experimental data points. Predictions of the calibrated free-piston code are compared with RE-1000 free-piston Stirling engine sensitivity test data taken at NASA Lewis. Resonable agreement was obtained between the code predictions and the experimental data over a wide range of engine operating conditions.

Geng, Steven M.↗

Microhardness and lattice parameter calibrations of the oxygen solid solutions of unalloyed alpha-titanium and Ti-6Al-2Sn-4Zr-2Mo

Standards were prepared for calibrating microanalyses of dissolved oxygen in unalloyed alpha-Ti and Ti-6Al-2Sn-4Zr-2Mo. Foils of both of these materials were homogenized for 120 hours in vacuum at 871 C following short exposures to the ambient atmosphere at 854 C that had partially oxidized the foils. The variation of Knoop microhardness with oxygen content was calibrated for both materials using 15-g and 5-g indentor loads. The unit-cell lattice parameters were calibrated for the unalloyed alpha-Ti. Example analyses demonstrate the usefulness of these calibrations and support an explanation of an anomaly in the lattice parameter variation. The results of the calibrations have been tabulated and summarized using predictive equations.

Wiedemann, K. E.↗

Automatic calibration of space based manipulators and mechanisms

Four tasks in manipulator kinematic calibration are summarized. Calibration of a seven degree of freedom manipulator was simulated. A calibration model is presented that can be applied on a closed-loop robot. It is an expansion of open-loop kinematic calibration algorithms subject to constraints. A closed-loop robot with a five-bar linkage transmission was tested. Results show that the algorithm converges within a few iterations. The concept of model differences is formalized. Differences are categorized as structural and numerical, with emphasis on the structural. The work demonstrates that geometric manipulators can be visualized as points in a vector space with the dimension of the space depending solely on the number and type of manipulator joint. Visualizing parameters in a kinematic model as the coordinates locating the manipulator in vector space enables a standard evaluation of the models. Key results include a derivation of the maximum number of parameters necessary for models, a formal discussion on the inclusion of extra parameters, and a method to predetermine a minimum model structure for a kinematic manipulator. A technique is presented that enables single point sensors to gather sufficient information to complete a calibration.

Everett, Louis J.↗

Calibration and comparison of the NASA Lewis free-piston Stirling engine model predictions with RE-1000 test data

A free-piston Stirling engine performance code is being upgraded and validated at the NASA Lewis Research Center under an interagency agreement between the Department of Energy's Oak Ridge National Laboratory and NASA Lewis. Many modifications were made to the free-piston code in an attempt to decrease the calibration effort. A procedure was developed that made the code calibration process more systematic. Engine-specific calibration parameters are often used to bring predictions and experimental data into better agreement. The code was calibrated to a matrix of six experimental data points. Predictions of the calibrated free-piston code are compared with RE-1000 free-piston Stirling engine sensitivity test data taken at NASA Lewis. Reasonable agreement was obtained between the code prediction and the experimental data over a wide range of engine operating conditions.

Geng, Steven M.↗

Radiometric calibration of IR Fourier transform spectrometers - Solution to a problem with the High-Resolution Interferometer Sounder

A calibrated Fourier transform spectrometer, known as the High-Resolution Interferometer Sounder (HIS), has been flown on the NASA U-2 research aircraft to measure the infrared emission spectrum of the earth. The primary use - atmospheric temperature and humidity sounding - requires high radiometric precision and accuracy (of the order of 0.1 and 1 C, respectively). To meet these requirements, the HIS instruments, the HIS instrument performs inflight radiometric calibration, using observations of hot and cold blackbody reference sources as the basis for two-point calibrations at each wavenumber. Initially, laboratory tests revealed a calibration problem with brightness temperature errors as large as 15 C between 600 and 900/cm. The symptom of the problem, which occurred in one of the three spectral bands of HIS, was a source-dependent phase response. Minor changes to the calibration equations completely eliminated the anomalous errors. The new analysis properly accounts for the situation in which the phase response for radiance from the instrument itself differs from that for radiance from an external source. The mechanism responsible for the dual phase response of the HIS instrument is identified as emission from the interferometer beam splitter.

Revercomb, Henry E.↗

Sensitivity of satellite-derived net shortwave irradiance at the Earth's surface to radiometric calibration

The effect of radiometric calibration uncertainties on satellite-derived net shortwave irradiance at the Earth's surface was examined. Net shortwave irradiance sensitivity to calibration is expressed as a function of two basic components that depend on surface and cloud albedo sensitivities, respectively. The analysis of these sensitivities for a wide range of atmospheric and surface conditions, as well as radiation geometries, shows that a 10 percent uncertainty in the calibration induces up to 40 W/sqm errors in instantaneous net shortwave irradiance (negative when the calibration uncertainty is positive). The maximum relative errors are obtained in overcast conditions when cloud albedos are high. On a monthly time scale, the induced error becomes typically 13 W/sqm in the tropics and 16 W/sqm in higher latitude regions during summer. The error almost vanishes at high latitudes during winter. A 10 percent positive uncertainty in the calibration gives a net shortwave irradiance error similar to that induced by the 3 hr sampling of the ISCCP Project.

Gautier, C.↗

The optical field angle distortion calibration feasibility study for the Hubble Space Telescope fine guidance sensors

The results of an analytical study to investigate the feasibility of calibrating the Hubble Space Telescope's (HST's) fine guidance sensors (FGSs) within HST mission accuracy limits are presented. The study has two purposes: (1) to determine the mathematical feasibility of the optical field angle distortion (OFAD) calibration algorithm and (2) to confirm that the OFAD, plate scale, and FGS-to-FGS alignment calibration algorithms produced a calibration of the FGSs that satisfied mission requirements. The study concluded that the mathematical specification of the OFAD algorithm is adequate and permits a determination of the FGS calibration parameters (accurate to better than 0.003 arc-second) sufficient to meet the mission requirements. The algorithms implemented, the characteristics of the simulated data and procedures for data analysis, and the study's results are discussed. In addition, several useful techniques for improving the stability and accuracy of the OFAD solution are outlined.

Luchetti, K.↗

Calibration of polarimetric radar systems with good polarization isolation

A practical technique is proposed for calibrating single-antenna polarimetric radar systems using a metal sphere plus any second target with a strong cross-polarized radar cross section. This technique assumes perfect isolation between antenna ports. It is shown that all magnitudes and phases (relative to one of the like-polarized linear polarization configurations) of the radar transfer function can be calibrated without knowledge of the scattering matrix of the second target. Comparison of the values measured (using this calibration technique) for a tilted cylinder at X-band with theoretical values shows agreement within + or - 0.3 dB in magnitude and + or - 5 degrees in phase. The radar overall cross-polarization isolation was 25 dB. The technique is particularly useful for calibrating a radar under field conditions, because it does not require the careful alignment of calibration targets.

Sarabandi, Kamal↗

Airborne Calibration Of An Orbiting Radiometer

Experiment demonstrates feasibility of using recently calibrated airborne radiometer to calibrate satellite-borne radiometer monitoring Earth and not calibrated since before launch. Calibration technique helps to assure Earth scientists of accuracy of satellite radiometric measurements taken during long time. Optical train of orbiting radiometer degraded slowly and sensitivities of detectors and gains of amplifiers changed slowly in outer-space environment, but frequent calibrations by airborne-radiometer technique make it possible to compensate for these changes.

Smith, Gilbert R.↗