In Situ Plasma processing of SRF cuperconducting cavities at JLAB, 2024 Update

Jefferson Lab has an ongoing R&D program in plasma processing. The experimental program investi-gated processing using argon/oxygen and heli-um/oxygen gas mixtures. Plasma processing is a com-mon technique where the free oxygen produced by the plasma breaks down and removes hydrocarbons from surfaces. This increases the work function and reduces the secondary emission coefficient. The initial focus of the effort was processing C100 cavities by injecting RF power into the high order mode (HOM) coupler ports. We also developed the methods for establishing a plasma in C75 cryomodules where the RF power is injected via the fundamental power-coupler. Four C100 cryomodules were in situ processed in the CE-BAF accelerator in May 2023 with the cryomodules returning to an operational status in Sept. 2023. The overall operational energy gain for the four cryomod-ules was 49 MeV. Methods, systems and results from processing cryomodules in the CEBAF accelerator and vertical test results are presented. Current status and future plans are discussed.

Powers, T.↗

New Progress with HF-free Chemical Finishing for Nb SRF Cavities

Jefferson Lab has implemented a bipolar pulsed electropolishing system for final chemical processing of niobium SRF cavities. This FARADAYIC bi-polar electropolishing (BPEP) has been applied to single cells, a 7-cell CEBAF C100 cavity, and to 9-cell TESLA-style cavities.* As a mechanistic characterization of the process emerges, the critical role played by the local current density during each cathodic pulse is becoming clear. This influences system and operational parameter refinement. We present current process parameters, removal characterization, and rf performance of the processed cavities. This is the fruit of collaborative work between Jefferson Lab and Faraday Technology, Inc. directed toward the routine commercialization and industrialization of niobium cavity processing. We also present supporting data from controlled-parameter coupon studies.

Tian, Hui↗

First SELAP Algorithm Operational Experience of the New LLRF 3.0 RF Control System

The JLAB LLRF 3.0 system has been developed and is replacing the 30-year-old LLRF systems in the CEBAF accelerator. The LLRF system builds upon 25 years of design and operational RF control experience (digital and analog), and our recent collaboration in the design of the LCLSII LLRF system. The new system also incorporates a cavity control algorithm using a fully functional phase and amplitude locked Self Exciting Loop (SELAP). The first system (controlling 8 cavities) was installed and commissioned in August of 2021. Since then the new LLRF system has been operating with cavity gradients up to 20 MV/m, and electron beam currents up to 350 uA. This paper discusses the operational experience of the LLRF 3.0 SELAP algorithm along with other software and firmware tools like cavity and klystron characterization and quench detection.

Plawski, T. E.↗

Interaction Region Magnets for Future Electron-Ion Collider ¿at Jefferson Lab

The Jefferson Lab Electron Ion Collider (JLEIC) is a pro-posed new machine for nuclear physics research. It uses the existing CEBAF accelerator as a full energy injector to deliver 3 to 12 GeV electrons into a new electron collider ring. An all new ion accelerator and collider complex will deliver up to 200 GeV protons. The machine has luminosity goals of 1034 cm-2 sec-1. The whole detector region including forward detection covers about 80 meters of the JLEIC complex. The interaction region design has recently been optimized to accommodate 200 GeV proton energy using conventional NbTi superconducting magnet technology. This paper will describe the requirements and preliminary designs for both the ion and electron beam magnets in the most complex 34.5 m long interaction region (IR) around the interaction point (IP). The interaction region has over thirty-four superconducting magnets operating at 4.5K; these include dipoles, quadrupoles, skew quadrupoles, solenoids, horizontal and vertical correctors and higher order multipole magnets. The paper will also dis-cuss the electromagnetic interaction between these magnets.

Rajput-Ghoshal, Renuka↗

JLab New Injector Cryomodule Design, Fabrication and Testing

A new Injector Cryomodule (INJ CM) aimed to replace the existing Quarter Cryomodule in the CEBAF tunnel has been developed at Jefferson Lab (JLab). It is scheduled to be first tested in the Cryomodule Test Facility (CMTF) for module performance then the Upgraded Injector Test Facility (UITF) with electron beam. This new cryomodule, hosting a 2-cell and 7-cell cavity, is designed to boost the electron energy from 200 keV to 5 MeV and permit 380 ?A ? 1.0 mA of beam current. The 2-cell cavity is a new design whereas the 7-cell cavity is refurbished from a low loss cavity from the retired JLab Renascence Cryomodule. The INJ CM adopts quite a few designs from the JLab 12 GeV Upgrade Cryomodule (C100). Examples of this include having the cold mass hung from a spaceframe structure by use of axial and transverse Nitronic rods, cavities to be tuned by scissor-jack style tuners and the end cans are actually modified from C100 style end cans. However, this new INJ CM is not a quarter of the C100 Cryomodule. This paper focuses on the major design features, fabrication and alignment process and testing of the module and its components.

Cheng, Guangfeng↗

Pansophy enhancements for SRF through collecting and analyzing inputs/outputs to further project efficiency in reporting and performance

SRF cavity and Cryomodule testing and production requires a consistent means of collecting and analyzing data against quality and production parameters. JLab's engineering data management system, Pansophy, is utilized to assist project leaders and subject matter experts (SMEs) with such tasks, by providing a means to data mine key parameter indicators (KPI) and production planning and status data. Recent enhancements to reporting and trending have been utilized for the LCLS-II and CEBAF 12GeV upgrade projects. Further enhancements are being planned for future projects, like SNS-PPU, such as KPI trending, KPI quality, vendor quality, production timelines and user defined queries. Being able to understand past trends will assist with enhancements to future projects.

Bookwalter, Valerie D.↗

Automation of particulate characterization

Foreign particles residing on the field carrying surface of accelerator cavities are a known mechanism for field emission. Developing the methods and tools for collecting and characterizing particles found in an accelerator enables process development towards field emission free SRF cavities. Methods are presented for sampling assemblies, components, processes, and environmental conditions utilizing forensic techniques with specialized tooling. Sampling activities to date have produced an inventory of over 850 GSR spindles. Traditional SEM + EDS analysis of this volume of spindles is challenged by labor investment, spindle sampling methods, and the subsequent data pipeline which ultimately results in a statically inadequate dataset for any particulate distribution characterization. A complete systematic analysis of the spindles is enabled by third party software controlling SEM automation for EDS data acquisition. Details of spindle creation, collection equipment, component sampling, automating particle assessment, and data analysis used to characterize samples from beamline elements in CEBAF are presented.

Spradlin, Josh↗

In Situ Plasma Processing of Superconducting Cavities at Jefferson Lab

Jef­fer­son Lab began a plasma pro­cess­ing pro­gram start­ing in the spring of 2019. Plasma pro­cess­ing is a com­mon tech­nique for re­mov­ing hy­dro­car­bons from sur­faces, which in­creases the work func­tion and re­duces the sec­ondary emis­sion co­ef­fi­cient. Un­like he­lium pro­cess­ing which re­lies on ion bom­bard­ment of the field emit­ters, plasma pro­cess­ing uses free oxy­gen pro­duced in the plasma to break down the hy­dro­car­bons on the sur­face of the cav­ity. The resid­u­als of the hy­dro­car­bons in the form of water, car­bon monox­ide and car­bon diox­ide are re­moved from the cry­omod­ule as part of the process gas flow. The ini­tial focus of the ef­fort is pro­cess­ing C100 cav­i­ties by in­ject­ing RF power into the HOM cou­pler ports. We will then start in­ves­ti­gat­ing pro­cess­ing of C50 cav­i­ties by in­tro­duc­ing RF into the fun­da­men­tal power cou­pler. The plan is to start pro­cess­ing cry­omod­ules in the CEBAF tun­nel in the mid-term fu­ture, with a goal of im­prov­ing the op­er­a­tional gra­di­ents and the en­ergy mar­gin of the linacs. This work will de­scribe the sys­tems and meth­ods used at JLAB for pro­cess­ing cav­i­ties using an argon oxy­gen gas mix­ture. Be­fore and after plasma pro­cess­ing re­sults will also be pre­sented.

Powers, T.↗

PRESERVATION OF THE HIGH QUALITY FACTOR AND ACCELERATING GRADIENT OF Nb3Sn-COATED CAVITY DURING PAIR ASSEMBLY

Two CEBAF 5-cell accelerator cavities have been coated with Nb3Sn film using the vapor diffusion technique. One cavity was coated in the Jefferson Lab Nb3Sn cavity coating system, and the other in the Fermilab Nb3Sn coating system. Both cavities were measured at 4 K and 2 K in the vertical dewar test in each lab and then assembled into a cavity pair at Jefferson Lab. Previous attempts to assemble Nb3Sn cavities into a cavity pair degraded the superconducting properties of Nb3Sn-coated cavities. This contribution discusses the efforts to identify and mitigate the pair assembly challenges and will present the results of the vertical tests before and after pair assembly. Notably, one of the cavities reached the highest gradient above 80 mT in the vertical test after the pair assembly.

Eremeev, G.V.↗

Proceedings of RIKEN BNL Research Center Workshop: Brookhaven Summer Program on Nucleon Spin Physics

Understanding the structure of the nucleon is of fundamental importance in sub-atomic physics. Already the experimental studies on the electro-magnetic form factors in the 1950s showed that the nucleon has a nontrivial internal structure, and the deep inelastic scattering experiments in the 1970s revealed the partonic substructure of the nucleon. Modern research focuses in particular on the spin and the gluonic structure of the nucleon. Experiments using deep inelastic scattering or polarized p-p collisions are carried out in the US at the CEBAF and RHIC facilities, respectively, and there are other experimental facilities around the world. More than twenty years ago, the European Muon Collaboration published their first experimental results on the proton spin structure as revealed in polarized deep inelastic lepton-nucleon scattering, and concluded that quarks contribute very little to the proton's spin. With additional experimental and theoretical investigations and progress in the following years, it is now established that, contrary to naive quark model expectations, quarks and anti-quarks carry only about 30% of the total spin of the proton. Twenty years later, the discovery from the polarized hadron collider at RHIC was equally surprising. For the phase space probed by existing RHIC experiments, gluons do not seem to contribute any to the proton's spin. To find out what carries the remaining part of proton's spin is a key focus in current hadronic physics and also a major driving force for the new generation of spin experiments at RHIC and Jefferson Lab and at a future Electron Ion Collider. It is therefore very important and timely to organize a series of annual spin physics meetings to summarize the status of proton spin physics, to focus the effort, and to layout the future perspectives. This summer program on 'Nucleon Spin Physics' held at Brookhaven National Laboratory (BNL) on July 14-27, 2010 [http://www.bnl.gov/spnsp/] is the second one following the Berkeley Summer Program taken place in June of 2009. This program at BNL focused on theory and had many presentations on a wide range of theoretical aspects on nucleon spin, from perturbative-QCD calculations to models, and to the first principle lattice calculation. It also had a good number of summary talks from all major experimental collaborations on spin physics. The program facilitated many discussions between theorists as well as experimentalists. With five transparencies from each presentation at the Summer Program, this proceedings provides a valuable summary on the status and progress, as well as the future prospects of spin physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Application of Chebyshev Formalism to Identify Nonlinear Magnetic Field Components in Beam Transport Systems

An experiment was conducted at Jefferson Lab's Continuous Electron Beam Accelerator Facility to develop a beam-based technique for characterizing the extent of the nonlinearity of the magnetic fields of a beam transport system. Horizontally and vertically oriented pairs of air-core kicker magnets were simultaneously driven at two different frequencies to provide a time-dependent transverse modulation of the beam orbit relative to the unperturbed reference orbit. Fourier decomposition of the position data at eight different points along the beamline was then used to measure the amplitude of these frequencies. For a purely linear transport system one expects to find solely the frequencies that were applied to the kickers with amplitudes that depend on the phase advance of the lattice. In the presence of nonlinear fields one expects to also find harmonics of the driving frequencies that depend on the order of the nonlinearity. Chebyshev polynomials and their unique properties allow one to directly quantify the magnitude of the nonlinearity with the minimum error. A calibration standard was developed using one of the sextupole magnets in a CEBAF beamline. The technique was then applied to a pair of Arc 1 dipoles and then to the magnets in the Transport Recombiner beamline to measure their multipole content as a function of transverse position within the magnets.

43 PARTICLE ACCELERATORS↗

Measurement of Single Spin Asymmetries in Semi-Inclusive Deep Inelastic Scattering Reaction n ↑ (e, e'π + ) X at Jefferson Lab

What constitutes the spin of the nucleon? The answer to this question is still not completely understood. Although we know the longitudinal quark spin content very well, the data on the transverse quark spin content of the nucleon is still very sparse. Semi-inclusive Deep Inelastic Scattering (SIDIS) using transversely polarized targets provide crucial information on this aspect. The data that is currently available was taken with proton and deuteron targets. The E06-010 experiment was performed at Jefferson Lab in Hall-A to measure the single spin asymmetries in the SIDIS reaction n ↑ (e, e'π ± /K ± )X using transversely polarized 3 He target. The experiment used the continuous electron beam provided by the CEBAF accelerator with a beam energy of 5.9 GeV. Hadrons were detected in a high-resolution spectrometer in coincidence with the scattered electrons detected by the BigBite spectrometer. The kinematic coverage focuses on the valence quark region, x = 0.19 to 0.34, at Q 2 = 1.77 to 2.73 (GeV/c) 2 . This is the first measurement on a neutron target. The data from this experiment, when combined with the world data on the proton and the deuteron, will provide constraints on the transversity and Sivers distribution functions on both the u and d-quarks in the valence region. In this work we report on the single spin asymmetries in the SIDIS n ↑ (e, e'π + )X reaction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beam Size Measurement by Optical Diffraction Radiation and Laser System for Compton Polarimeter

Beam diagnostics is an essential constituent of any accelerator, so that it is named as "organs of sense" or "eyes of the accelerator." Beam diagnostics is a rich field. A great variety of physical effects or physical principles are made use of in this field. Some devices are based on electro-magnetic influence by moving charges, such as faraday cups, beam transformers, pick-ups; Some are related to Coulomb interaction of charged particles with matter, such as scintillators, viewing screens, ionization chambers; Nuclear or elementary particle physics interactions happen in some other devices, like beam loss monitors, polarimeters, luminosity monitors; Some measure photons emitted by moving charges, such as transition radiation, synchrotron radiation monitors and diffraction radiation-which is the topic of the first part of this thesis; Also, some make use of interaction of particles with photons, such as laser wire and Compton polarimeters-which is the second part of my thesis. Diagnostics let us perceive what properties a beam has and how it behaves in a machine, give us guideline for commissioning, controlling the machine and indispensable parameters vital to physics experiments. In the next two decades, the research highlight will be colliders (TESLA, CLIC, JLC) and fourth-generation light sources (TESLA FEL, LCLS, Spring 8 FEL) based on linear accelerator. These machines require a new generation of accelerator with smaller beam, better stability and greater efficiency. Compared with those existing linear accelerators, the performance of next generation linear accelerator will be doubled in all aspects, such as 10 times smaller horizontal beam size, more than 10 times smaller vertical beam size and a few or more times higher peak power. Furthermore, some special positions in the accelerator have even more stringent requirements, such as the interaction point of colliders and wigglor of free electron lasers. Higher performance of these accelerators increases the difficulty of diagnostics. For most cases, intercepting measurements are no longer acceptable, and nonintercepting method like synchrotron radiation monitor can not be applied to linear accelerators. The development of accelerator technology asks for simutanous diagnostics innovations, to expand the performance of diagnostic tools to meet the requirements of the next generation accelerators. Diffraction radiation and inverse Compton scattering are two of the most promising techniques, their nonintercepting nature avoids perturbance to the beam and damage to the instrumentation. This thesis is divided into two parts, beam size measurement by optical diffraction radiation and Laser system for Compton polarimeter. Diffraction radiation, produced by the interaction between the electric field of charged particles and the target, is related to transition radiation. Even though the theory of diffraction radiation has been discussed since 1960s, there are only a few experimental studies in recent years. The successful beam size measurement by optical diffraction radiation at CEBAF machine is a milestone: First of all, we have successfully demonstrated diffraction radiation as an effective nonintercepting diagnostics; Secondly, the simple linear relationship between the diffraction radiation image size and the actual beam size improves the reliability of ODR measurements; And, we measured the polarized components of diffraction radiation for the first time and I analyzed the contribution from edge radiation to diffraction radiation.

43 PARTICLE ACCELERATORS↗

Investigation of high-precision Λ hypernuclear spectroscopy via the (e,e'K + ) reaction

The study of Λ hypernuclear structure is very interesting in point of the understanding of the interaction between Λ and nucleon (Λ-N interaction) and its strange structure itself due to the containment of a Λ hyperon which has a strangeness as a new degree of freedom. In the several way to study the Lamda hypernuclei, the (e,e&#x27;K + ) reaction spectroscopy is a powerful tool for the precise investigation of Λ hypernuclear structure. The purpose of the preset thesis is the establishment of the experimental design with the efficient data analysis method for the (e,e&#x27;K + ) hypernuclear spectroscopic experiment in the wide mass region (from A=7 to A=52). It is very challenging to perform the (e,e&#x27;K + ) spectroscopic experiment with such a heavy target, because of the huge electron background due to the bremsstrahlung process. In the experiment, it is required to obtain the necessary hypernuclear yield, suppressing the background event ratio. We achieved these requirements by newly constructing the high resolution electron spectrometer (HES) and splitter magnet (SPL) dedicated to the (e,e&#x27;K + ) spectroscopic experiment. The HES consists of two quadrupole magnets and a dipole magnets (Q-Q-D) with a momentum resolution of dp/p = 3x10 -4 at p = 0.84 GeV/c. It was used being vertically tilted by 6.5 degree so as to optimize signal to noise ratio and hypernuclear yield. The SPL is a dipole magnet. The experimental target was placed at the entrance of this magnet. The role of the SPL is to separate four kind of particles; scattered kaons, photons created by the bremsstrahlung, the post beam and scattered electrons. In addition, since the SPL is a part of the kaon and electron spectrometers. We designed the magnet shape carefully considering these points. The experiment was performed with 2.344 GeV/c electron beam from CEBAF at Jefferson Lab. The experimental setup consists of the HES, SPL and HKS (high momentum resolution kaon spectrometer). The HKS is also a Q-Q-D type spectrometer with the momentum resolution of dp/p = 2x10 -4 at p = 1.2 GeV/c. In the data analysis, the particle momentum calibration was the most important procedure. At the initial point, the particle momentum was obtained from the calculated magnetic field map of the spectrometer whose accuracy is an order of 10 -2 . The initial momentum was calibrated by two step, the the magnetic field map improvement and the calibration with known masses of Λ/σ 0 which were observed by the CH 2 target data. As a result of the calibration, the momentum resolutions of HKS and HES were estimated as 4x10 -4 and 6x10 -4 , respectively. Though these values are the double of the designed value, it was achieved to obtain the Λ/σ 0 peaks with the same order of the designed energy from the original calculated magnetic field. The cross section was calculated with the several estimated factors. The averaged p(γ*, K + )Λ cross section in the HKS acceptance, (0.90 < cos(θ^CM_K + ) < 1.0) was calculated as 227 ± 12 ±26 [nb/sr], which is consistent within the error bar with the other experiment results of p(γ, K + )Λ. The obtained yield of the peak was almost same as the designed value with the considered detector efficiencies. The observed hypernuclear spectrum of 12 Λ B was also consistent with the other experimental results. These analysis result represents that the experimental setup including the newly constructed HES and SPL worked and the calibration procedure of this unique experimental setup is basically established.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of the Two-pion Photoproduction on the Deuteron

Understanding the structure of baryons in terms of the fundamental interaction of the constituent quarks and gluons is one of the primary challenges in strong interaction physics. This interaction is governed by Quantum Chromodynamics (QCD), which is a theory for understanding the dynamics of strong. QCD displays the asymptotic freedom of hadrons at very short distances and also the confinement of quarks and gluons inside hadrons. However, solutions of this QCD theory in the non-perturbative domain of the interaction are extremely difficult to achieve, mainly because confinement happens on the hadronic scale on which the coupling constant is large and prevents any perturbative approach. Thus leaving us with strategies such as lattice QCD or formulating QCD sum rules to get around this problem. In exclusive hadron production the yN interaction is recognized for being a powerful method for investigating hadrons and the mysteries that still exist within the strong interaction. From reactions with the nucleon, the strong interaction can be investigated through the transition amplitudes to the N and Delta resonances. More specifically, if an electromagnetic interaction is well known then the intermediate resonance states may be evaluated through meson photoproduction. To gain more detailed insight into this interaction, we look to probe the baryon structure of the nucleon and the photo-excited resonance decays through photon scattering off a deuteron producing two pions in the final state. This photoproduction process off the deuteron will be used to investigate known baryon resonances in the two pion channel. The two pion final state will be investigated for unraveling new information into the photo-coupling strengths. We want to explore final state interactions, search for properties of known resonances, and to explore the possibility of seeing missing states that are predicted by quark models but have not yet been found experimentally. Using the CEBAF Large Acceptance Spectrometer (CLAS), the hadronic products are detected in coincidence with the incident scattered photon on a deuterium target. This makes it possible to measure the single differential cross sections and the decay angular distributions for the production of two pion final states. The measured cross sections will contribute significantly to a better understanding of the coupling strengths that govern the baryonic and mesonic resonances which will push the knowledge of the strong interaction to a next level. We use CLAS to study the two pion channel from the eg3 data set, for resonance production, specifically investigating the exclusive reaction of yd --> p pi^+pi^?n, and comparing the relevant cross sections to already existing data sets. The eg3 data set provided an excellent data set for investigating photo-induced baryonic and mesonic resonances. It contains a large photon tagging range from 1.1 to 5.5 GeV in the study of photo-coupling strengths, as well as an available two pion reaction channel for resonant decay study. These measurements provide unique and coherent results from tagged photons over a broad range of energy, and represent the only two pion production data above 5 GeV at this present time. We found that the data produced good comparable single-differentials cross sections to other existing CLAS (gll dataset) two pion differential cross sections, and an excellent comparable total cross section to published (ELSA and ABBHHM) two pion total cross sections.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of a Positron Source for JLab at the IAC

We report on the research performed towards the development of a positron sour for Jefferson Lab's (JLab) Continuous Electron Beam Accelerator Facility (CEBAF) in Newport News, VA. The first year of work was used to benchmark the predictions of our current simulation with positron production efficiency measurements at the IAC. The second year used the benchmarked simulation to design a beam line configuration which optimized positron production efficiency while minimizing radioactive waste as well as design and construct a positron converter target. The final year quantified the performance of the positron source. This joint research and development project brought together the experiences of both electron accelerator facilities. Our intention is to use the project as a spring board towards developing a program of accelerator based research and education which will train students to meet the needs of both facilities as well as provide a pool of trained scientists.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pulsed-focusing recirculating linacs for muon acceleration

Since the muon has a short lifetime, fast acceleration is essential for high-energy applications such as muon colliders, Higgs factories, or neutrino factories. The best one can do is to make a linear accelerator with the highest possible accelerating gradient to make the accelerating time as short as possible. However, the cost of such a single linear accelerator is prohibitively large due to expensive power sources, cavities, tunnels, and related infrastructure. As was demonstrated in the Thomas Jefferson Accelerator Facility (Jefferson Lab) Continuous Electron Beam Accelerator Facility (CEBAF), an elegant solution to reduce cost is to use magnetic return arcs to recirculate the beam through the accelerating RF cavities many times, where they gain energy on each pass. In such a Recirculating Linear Accelerator (RLA), the magnetic focusing strength diminishes as the beam energy increases in a conventional linac that has constant strength quadrupoles. After some number of passes the focusing strength is insufficient to keep the beam from going unstable and being lost. In this project, the use of fast pulsed quadrupoles in the linac sections was considered for stronger focusing as a function of time to allow more successive passes of a muon beam in a recirculating linear accelerator. In one simulation, it was shown that the number of passes could be increased from 8 to 12 using pulsed magnet designs that have been developed and tested. This could reduce the cost of linac sections of a muon RLA by 8/12, where more improvement is still possible. The expense of a greater number of passes and corresponding number of return arcs was also addressed in this project by exploring the use of ramped or FFAG-style magnets in the return arcs. A better solution, invented in this project, is to use combined-function dipole-quadrupole magnets to simultaneously transport two beams of different energies through one magnet string to reduce costs of return arcs by almost a factor of two. A patent application was filed for this invention and a detailed report published in Physical Review Special Topics. A scaled model using an electron beam was developed and proposed to test the concept of a dog bone RLA with combined-function return arcs. The efforts supported by this grant were reported in a series of contributions to particle accelerator conferences that are reproduced in the appendices and summarized in the body of this report.

43 PARTICLE ACCELERATORS↗

Improved DC Gun and Insulator Assembly

Many user facilities such as synchrotron radiation light sources and free electron lasers rely on DC high voltage photoguns with internal field gradients as high as 10 to 15 MV/m. These high gradients often lead to field emission which poses serious problems for the photocathode used to generate the electron beam and the ceramic insulators used to bias the photocathode at high voltage. Ceramic insulators are difficult to manufacture, require long commissioning times, and have poor reliability, in part because energetic electrons bury themselves in the ceramic causing a buildup of charge and eventual puncture, and also because large diameter ceramics are difficult to braze reliably. The lifetimes of photo cathodes inside high current DC guns exhibiting field emission are limited to less than a hundred hours. Reducing the surface gradients on the metals reduces the field emission, which serves to maintain the required ultrahigh vacuum condition. A novel gun design with gradients around 5 MV/m and operating at 350 kV, a major improvement over existing designs, was proposed that allows for the in-situ replacement of photo cathodes in axially symmetric designs using inverted ceramics. In this project, the existing JLAB CEBAF asymmetric gun design with an inverted ceramic support was modeled and the beam dynamics characterized. An improved structure was designed that reduces the surface gradients and improves the beam optics. To minimize the surface gradients, a number of electrostatic gun designs were studied to determine the optimum configuration of the critical electrodes within the gun structure. Coating experiments were carried out to create a charge dissipative coating for cylindrical ceramics. The phase II proposal, which was not granted, included the design and fabrication of an axially symmetric DC Gun with an inverted ceramic that would operate with less than 5 MV/m at 350 kV and would be designed with an in-situ replaceable photo-cathode.

43 PARTICLE ACCELERATORS↗