Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONVENTIONAL RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

SU-D-213-01: Transparent Photon Detector For The Online Monitoring Of IMRT Beams

Purpose: An innovative Transparent Detector for Radiotherapy (TraDeRa) has been developed. The detector aims at real-time monitoring of modulated beam ahead of the patient during delivery sessions, with a field cover up to 40×40 cm {sup 2}. Methods: TraDeRa consists in a pixelated matrix of ionization chambers with a patented electrodes design. An in-house designed specific integrated circuit allows to extract the signal and provides a real-time map of beam intensity and shape, at the linac pulse-scale. The measurements under irradiation are made with a 6 MV clinical X-Ray beam. Dose calculations are performed with the Monte Carlo code PENELOPE, modeling the full accelerator head and the TraDeRa detector. Results: A 2 % attenuation of the beam was measured in the presence of TraDeRa and the PENELOPE dosimetric study showed no significant modification of the photon beam properties. TraDeRa detects error leaf position as small as 1 mm compared to a reference field, for both static and modulated fields. In addition, measurements are accurate over a large dynamic range from low intensity signals, as inter-leaves leaks, to very high intensities as obtained on the medical line of the European Synchrotron Radiation Facility. The detector is fully operational for conventional and high dose rate beams as FFF modes (up to 2400 MU/min). Conclusion: The current version of TraDeRa shows promising results for IMRT quality assurance (QA), allowing pulse-scale monitoring of the beam and high sensitivity for errors detection. The attenuation is small enough not to hinder the irradiation while keeping the beam upstream of the patient under constant control. A final prototype under development will include 1600 independent electrodes, half of them with a high resolution centered on the beam axis. This compact detector provides an independent set of measurements for a better QA. Funding support : This work was supported by the LABEX PRIMES (ANR-11-LABX-0063) of Universite de Lyon, within the program “Investissements d’Avenir” (ANR-11-IDEX-0007) operated by the French National Research Agency (ANR) and within the project “INSPIRA” operated by the OSEO institution.

60 APPLIED LIFE SCIENCES↗

Non-Conventional Applications of Computerized Tomography: Analysis of Solid Dosage Forms Produced by Pharmaceutical Industry

X-ray computed tomography (CT) refers to the cross-sectional imaging of an object measuring the transmitted radiation at different directions. In this work, we describe a non-conventional application of computerized tomography: visualization and improvements in the understanding of some internal structural features of solid dosage forms. A micro-CT X-ray scanner, with a minimum resolution of 30 mum was used to characterize some pharmaceutical tablets, granules, controlled-release osmotic tablet and liquid-filled soft-gelatin capsules. The analysis presented in this work are essentially qualitative, but quantitative parameters, such as porosity, density distribution, tablets dimensions, etc. could also be obtained using the related CT techniques.

07 ISOTOPE AND RADIATION SOURCES↗

Modeling the X-rays from the central compact object PSR J1852+0040 in Kesteven 79: Evidence for a strongly magnetized neutron star

I present modeling of the X-ray pulsations from the central compact object (CCO) PSR J1852+0040 in the Galactic supernova remnant Kesteven 79. In the context of thermal surface radiation from a rotating neutron star (NS), a conventional polar cap model can reproduce the broad, large-amplitude X-ray pulse only with a 'pencil plus fan' beam emission pattern, which is characteristic of ≳ 10{sup 12} G NS atmospheres, much greater than the ∼10{sup 10} G external dipole field inferred from the pulsar spin-down rate. This discrepancy can be explained by an axially displaced dipole. For other beaming patterns, it is necessary to invoke high-aspect-ratio emitting regions that are greatly longitudinally elongated, possibly due to an extremely offset dipole. For all assumed emission models, the existence of strong internal magnetic fields (≳ 10{sup 14} G) that preferentially channel internal heat to only a portion of the exterior is required to account for the implied high-temperature contrast across the stellar surface. This lends further observational evidence in support of the 'hidden' strong magnetic field scenario, in which CCOs possess submerged magnetic fields that are substantially stronger than the external dipole field, presumably due to burial by fallback of supernova ejecta. I also conduct phase-resolved X-ray spectroscopy and find no evidence for prominent spin-phase-dependent absorption features that could be produced by cyclotron absorption/scattering.

79 ASTRONOMY AND ASTROPHYSICS↗

MO-C-18A-01: Advances in Model-Based 3D Image Reconstruction

Recent years have seen the emergence of CT image reconstruction techniques that exploit physical models of the imaging system, photon statistics, and even the patient to achieve improved 3D image quality and/or reduction of radiation dose. With numerous advantages in comparison to conventional 3D filtered backprojection, such techniques bring a variety of challenges as well, including: a demanding computational load associated with sophisticated forward models and iterative optimization methods; nonlinearity and nonstationarity in image quality characteristics; a complex dependency on multiple free parameters; and the need to understand how best to incorporate prior information (including patient-specific prior images) within the reconstruction process. The advantages, however, are even greater – for example: improved image quality; reduced dose; robustness to noise and artifacts; task-specific reconstruction protocols; suitability to novel CT imaging platforms and noncircular orbits; and incorporation of known characteristics of the imager and patient that are conventionally discarded. This symposium features experts in 3D image reconstruction, image quality assessment, and the translation of such methods to emerging clinical applications. Dr. Chen will address novel methods for the incorporation of prior information in 3D and 4D CT reconstruction techniques. Dr. Pan will show recent advances in optimization-based reconstruction that enable potential reduction of dose and sampling requirements. Dr. Stayman will describe a “task-based imaging” approach that leverages models of the imaging system and patient in combination with a specification of the imaging task to optimize both the acquisition and reconstruction process. Dr. Samei will describe the development of methods for image quality assessment in such nonlinear reconstruction techniques and the use of these methods to characterize and optimize image quality and dose in a spectrum of clinical applications. Learning Objectives: Learn the general methodologies associated with model-based 3D image reconstruction. Learn the potential advantages in image quality and dose associated with model-based image reconstruction. Learn the challenges associated with computational load and image quality assessment for such reconstruction methods. Learn how imaging task can be incorporated as a means to drive optimal image acquisition and reconstruction techniques. Learn how model-based reconstruction methods can incorporate prior information to improve image quality, ease sampling requirements, and reduce dose.

60 APPLIED LIFE SCIENCES↗

Laboratory Study of Nonlinear QED in Intense Laser-Matter Interactions

The goal of the project was to investigate the interaction of powerful laser light with matter, which is of fundamental interest to electrodynamics, thermonuclear fusion plasmas, and high-energy-density physics for DOE. Experiments on highly nonlinear relativistic interactions were performed using the state-of-the-art DIOCLES laser at the Extreme Light Laboratory of the University of Nebraska–Lincoln (UNL). We have demonstrated a novel testbed for laser-plasma interactions in which laser pulses collided in plasma with femtosecond and micron-scale accuracy under extreme experiment conditions. This capability is crucial for future radiation reaction experiments and nonlinear QED studies. Moreover, this is also a milestone towards the efficient generation of GeV electron beams via travelling wave laser wakefield accelerator. We proposed a novel idea for measuring the radiation reaction process using travelling wave Thomson scattering, which was studied in numerical simulations. This method allows unambiguous measurement of radiation reaction in a single shot, therefore, surpassing the conventional methods, which suffer severely from the shot-to-shot fluctuations, due to the instability of laser wavefield acceleration.

74 ATOMIC AND MOLECULAR PHYSICS↗

Risk of Hypogonadism From Scatter Radiation During Pelvic Radiation in Male Patients With Rectal Cancer

Purpose: Recent studies have reported fluctuations in sex hormones during pelvic irradiation. The objective of this study was to observe the effects of radiation on hormonal profiles for two treatment modalities: conventional external beam radiotherapy (EBRT) and high-dose-rate brachytherapy (HDRBT) given neoadjuvantly for patients with rectal cancer. Methods and Materials: Routine serum follicle stimulating hormone (FSH), luteinizing hormone (LH), and testosterone levels were collected from 119 consecutive male patients receiving either EBRT, using 45.0-50.4 Gy in 25-28 fractions with concurrent 5-fluorouracil chemotherapy or HDRBT using 26 Gy in 4 fractions. Results: Thirty patients with initially abnormal profiles were excluded. Profiles included in this study were collected from 51 patients treated with EBRT and 38 patients treated with HDRBT, all of whom had normal hormonal profiles before treatment. Mean follow-up times were 17 months for the entire patient cohort-14 and 20 months, respectively-for the EBRT and HDRBT arms. Dosimetry results revealed a mean cumulative testicular dose of 1.24 Gy received in EBRT patients compared with 0.27 Gy in the HDRBT group. After treatment, FSH and LH were elevated in all patients but were more pronounced in the EBRT group. The testosterone-to-LH ratio was significantly lower (p = 0.0036) in EBRT patients for tumors in the lower third of the rectum. The 2-year hypogonadism rate observed was 2.6% for HDRBT compared with 17.6% for EBRT (p = 0.09) for tumors in the lower two thirds of the rectum. Conclusion: HDRBT allows better hormonal sparing than EBRT during neoadjuvant treatment of patients with rectal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-R-48: Early Prediction of Pathological Response of Locally Advanced Rectal Cancer Using Perfusion CT:A Prospective Clinical Study

Purpose: To prospectively evaluate the tumor vascularity assessed by perfusion CT for prediction of chemo-radiation treatment (CRT) response in locally advanced rectal cancer (LARC). Methods: Eighteen consecutive patients (61.9±8.8 years, from March–June 2015) diagnosed with LARC who underwent 6–8 weeks CRT followed by surgery were included. The pre-treatment perfusion CT was acquired after a 5s delay of contrast agent injection for 45s with 1s interval. A total of 7-cm craniocaudal range covered the tumor region with 3-mm slice thickness. The effective radiation dose is around 15mSv, which is about 1.5 the conventional abdomen/pelvis CT dose. The parametric map of blood flow (BF), blood volume (BV), mean transit time (MTT), permeability (PMB), and maximum intensity map (MIP) were obtained from commercial software (Syngo-CT 2011A, Siemens). An experienced radiation oncologist outlined the tumor based on the pre-operative MR and pathologic residual region, but was blinded with regards to pathological tumor stage. The perfusion parameters were compared to histopathological response quantified by tumor regression grade as good-responder (GR, TRG 0-1) vs. non-good responder (non-GR). Furthermore, the predictive value for pathological complete response (pCR) was also investigated. Results: Both BV (p=0.02) and MTT (P=0.02) was significantly higher and permeambility was lower (p=0.004) in the good responders. The BF was higher in GR group but not statistically significant. Regarding the discrimination of pCR vs non-pCR, the BF was higher in the pCR group (p=0.08) but none of those parameters showed statistically significant differences. Conclusion: BV and MTT can discriminate patients with a favorable response from those that fail to respond well, potentially selecting high-risk patients with resistant tumors that may benefit from an aggressive preoperative treatment approach. However, future studies with more patient data are needed to verify the prognostic value of perfusion CT especially for pCR prediction. This work is supported by the National High-tech R&D program for Young Scientists by the Ministry of Science and Technology of China (Grant No. 2015AA020917), Natural Science Foundation of China (NSFC Grant No. 81201091).

60 APPLIED LIFE SCIENCES↗

Thermoacoustic imaging over large field of view for three-dimensional breast tumor localization: A phantom study

Purpose: Previous studies demonstrated that thermoacoustic imaging (TAI) has great potential for breast tumor detection. However, large field of view (FOV) imaging remains a long-standing challenge for three-dimensional (3D) breast tumor localization. Here, the authors propose a practical TAI system for noninvasive 3D localization of breast tumors with large FOV through the use of ultrashort microwave pulse (USMP). Methods: A USMP generator was employed for TAI. The energy density required for quality imaging and the corresponding microwave-to-acoustic conversion efficiency were compared with that of conventional TAI. The microwave energy distribution, imaging depth, resolution, and 3D imaging capabilities were then investigated. Finally, a breast phantom embedded with a laboratory-grown tumor was imaged to evaluate the FOV performance of the USMP TAI system, under a simulated clinical situation. Results: A radiation energy density equivalent to just 1.6%–2.2% of that for conventional submicrosecond microwave TAI was sufficient to obtain a thermoacoustic signal with the required signal-to-noise ratio. This result clearly demonstrated a significantly higher microwave-to-acoustic conversion efficiency of USMP TAI compared to that of conventional TAI. The USMP TAI system achieved 61 mm imaging depth and 12 × 12 cm{sup 2} microwave radiation area. The volumetric image of a copper target measured at depth of 4–6 cm matched well with the actual shape and the resolution reaches 230 μm. The TAI of the breast phantom was precisely localized to an accuracy of 0.1 cm over an 8 × 8 cm{sup 2} FOV. Conclusions: The experimental results demonstrated that the USMP TAI system offered significant potential for noninvasive clinical detection and 3D localization of deep breast tumors, with low microwave radiation dose and high spatial resolution over a sufficiently large FOV.

60 APPLIED LIFE SCIENCES↗

Developing a Radar Signal Simulator for the Community Radiative Transfer Model

Active radar instruments provide vertically resolved clouds and precipitation measurements that cannot be provided by the passive instruments. These active measurements are not conventionally assimilated into the data assimilation systems because of the lack of fast forward radiative transfer models and also difficulties in the error modelling of the measurements. This paper describes the development, evaluation, and sensitivity analysis for a forward radar model implemented in the Community Radiative Transfer Model (CRTM). The scattering properties required by the forward model are provided by the hydrometeor lookup tables that were generated using the discrete dipole approximation. The model is able to calculate both the reflectivity and the attenuated reflectivity for any given radar instrument at any given zenith angles as long as CRTM instrument specific coefficients are available. The evaluation using CloudSat measurements shows a very good agreement between the simulations and measurements as long as the input profiles of hydrometeors are consistent with the measured reflectivity profiles. Major sources contributing to the differences between the measured and simulated reflectivities are input hydrometeor profiles, scattering lookup tables, lack of melting layer in the forward model, CRTM scattering solvers, and attenuation calculations. In addition to the forward model, both Tangent Linear and Adjoint of the model are also implemented and tested within CRTM. These components may be required by some data assimilation systems for the assimilation of radar measurements.

radar↗

Ultrafast Imaging of Laser Driven Shock Waves using Betatron X-rays from a Laser Wakefield Accelerator

Abstract Betatron radiation from laser wakefield accelerators is an ultrashort pulsed source of hard, synchrotron-like x-ray radiation. It emanates from a centimetre scale plasma accelerator producing GeV level electron beams. In recent years betatron radiation has been developed as a unique source capable of producing high resolution x-ray images in compact geometries. However, until now, the short pulse nature of this radiation has not been exploited. This report details the first experiment to utilize betatron radiation to image a rapidly evolving phenomenon by using it to radiograph a laser driven shock wave in a silicon target. The spatial resolution of the image is comparable to what has been achieved in similar experiments at conventional synchrotron light sources. The intrinsic temporal resolution of betatron radiation is below 100 fs, indicating that significantly faster processes could be probed in future without compromising spatial resolution. Quantitative measurements of the shock velocity and material density were made from the radiographs recorded during shock compression and were consistent with the established shock response of silicon, as determined with traditional velocimetry approaches. This suggests that future compact betatron imaging beamlines could be useful in the imaging and diagnosis of high-energy-density physics experiments.

43 PARTICLE ACCELERATORS↗

Defect-Mediated Anisotropic Lattice Expansion in Ceramics as Evidence for Nonthermal Coupling between Electromagnetic Fields and Matter

Electromagnetic (EM) fields can trigger a range of surprising responses in materials. Microwave radiation (MWR), a type of EM field in the frequency range of 0.3–300GHz, can lower the synthesis temperature required for ceramics such as TiO2 and induces mixed amorphous–crystalline phase compositions. To better understand the effects of MWR on matter, structural changes during microwave heating and MWR-assisted synthesis using in situ synchrotron X-ray diffraction are studied. Anisotropic expansion–contraction of lattice parameters under microwave-radiation is observed, which contradicts the results from conventional thermal heating. When as-received TiO2 powders are heated with MWR, an instantaneous decrease in the intensities of diffraction peaks indicates decrystallization/amorphization. High resolution electron microscopy supports these observations. Raman spectroscopy and X-ray photoemission spectroscopy indicate increased defect-generation under microwave exposure. Molecular dynamics simulations on the anatase phase of TiO2 suggests that introducing an oxygen vacancy can lead to the formation of an interstitial–vacancy pair resulting in anisotropic expansion–contraction of the lattice. These unique responses of ceramics under externally applied fields provide direct evidence for nonthermal coupling between EM fields and matter. Understanding such nonthermal, field-driven processes has implications in engineering low-temperature processes for integrating ceramics with polymers for flexible electronics, energy harnessing, and storage applications.

anisotropic lattice expansion↗

Reduced Energetic Disorders in Dion–Jacobson Perovskites for Efficient and Spectral Stable Blue LEDs

Metal halide perovskites have witnessed great success in green, red, and near-infrared light-emitting diodes (LEDs), yet blue LEDs still lag behind. Reducing undesired energetic disorders – broad n -phases and halide segregation – is considered as the most critical strategy to further improve the performances. Here, the study reports a newly designed and synthesized di-ammonium ligand with rigid π -conjugated rings and additional methyl groups to construct Dion–Jacobson (DJ) structure. Augmented coordination from the extra ammonium site and increased effective bulkiness from methyl groups lead to better distribution control over conventional mono-ammonium ligands. This enhances the radiative recombination of blue emissions in the film with homogeneous energy landscape and improved surface morphology, as evidenced by a series of imaging and mapping techniques. As a result, it demonstrates DJ perovskite LEDs (PeLEDs) with peak external quantum efficiencies of ≈4% at 484 nm and ≈11% at 494 nm, which are among the top reported for pure DJ phase-based PeLEDs in the corresponding wavelength regions. The results deepen the understanding of regulating energetic disorders in perovskite materials via molecular engineering.

36 MATERIALS SCIENCE↗

The Table of Standard Atomic Weights—an exercise in consensus

The present Table of Standard Atomic Weights (TSAW) of the elements is perhaps one of the most familiar datasets in science. Unlike most parameters in physical science whose values and uncertainties are evaluated using the “Guidelines for Uncertainty in Measurement” (GUM), the majority of standard atomic-weight values and their uncertainties are consensus values, not GUM-evaluated values. The Commission on Isotopic Abundances and Atomic Weights of the International Union of Pure and Applied Chemistry (IUPAC) regularly evaluates the literature for new isotopic-abundance measurements that can lead to revised standard atomic-weight values, A r (E) for element E. The Commission strives to provide utmost clarity in products it disseminates, namely the TSAW and the Table of Isotopic Compositions of the Elements (TICE). In 2016, it was recognized by the Commission that a guideline recommending expression of uncertainty listed in parentheses following the standard atomic-weight value, e.g. A r (Se) = 78.971(8), is not in accord with the GUM, which suggests that this parenthetic notation be reserved to express standard uncertainty, not the expanded uncertainty used in the TSAW and TICE. In 2017, to eliminate this noncompliance with the GUM, a new format was adopted in which the uncertainty value is specified by the plus-minus symbol, e.g. A r (Se) = 78.971 ± 0.008. To clarify the definition of uncertainty, a new footnote has been added to the TSAW. This footnote emphasizes that an atomic-weight uncertainty is a consensus (decisional) uncertainty. Not only has the Commission shielded users of the TSAW and TICE from unreliable measurements that appear in the literature as a result of unduly small uncertainties, but the aim of IUPAC has been fulfilled by which any scientist, taking any natural sample from commerce or research, can expect their sample atomic weight to lie within A r (E) ± its uncertainty almost all of the time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cost-Effectiveness Analysis of Stereotactic Body Radiotherapy and Radiofrequency Ablation for Medically Inoperable, Early-Stage Non-Small Cell Lung Cancer

Purpose: The standard management of medically inoperable Stage I non-small-cell lung cancer (NSCLC) conventionally has been fractionated three-dimensional conformal radiation therapy (3D-CRT). The relatively poor local control rate and inconvenience associated with this therapy have prompted the development of stereotactic body radiotherapy (SBRT), a technique that delivers very high doses of irradiation typically over 3 to 5 sessions. Radiofrequency ablation (RFA) has also been investigated as a less costly, single-day therapy that thermally ablates small, peripheral tumors. The cost-effectiveness of these three techniques has never been compared. Methods and Materials: We developed a Markov model to describe health states of 65-year-old men with medically inoperable NSCLC after treatment with 3D-CRT, SBRT, and RFA. Given their frail state, patients were assumed to receive supportive care after recurrence. Utility values, recurrence risks, and costs were adapted from the literature. Sensitivity analyses were performed to model uncertainty in these parameters. Results: The incremental cost-effectiveness ratio for SBRT over 3D-CRT was $6,000/quality-adjusted life-year, and the incremental cost-effectiveness ratio for SBRT over RFA was $14,100/quality-adjusted life-year. One-way sensitivity analysis showed that the results were robust across a range of tumor sizes, patient utility values, and costs. This result was confirmed with probabilistic sensitivity analyses that varied local control rates and utilities. Conclusion: In comparison to 3D-CRT and RFA, SBRT was the most cost-effective treatment for medically inoperable NSCLC over a wide range of treatment and disease assumptions. On the basis of efficacy and cost, SBRT should be the primary treatment approach for this disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparative study of bulk and nano-structured mesoporous SnO 2 electrodes on the electrochemical performances for next generation Li rechargeable batteries

For next generation Li-ion batteries, advanced electrode materials with high energy densities are mightily important issue. Since the partial oxidation of Sn with Li 2 O to form SnO x was demonstrated upon delithiation in SnO 2 anode, the additional conversion reaction has contributed that the theoretical capacity of SnO 2 can be extended from 783 to 1494 mAh g -1 . Herein, with the design of additional conversion reaction, we discuss key factors for high electrochemical performances of the SnO 2 anodes through comparative analysis between nano-structured mesoporous SnO 2 and conventional bulk SnO 2 , based on synchrotron radiation-based techniques, quantitative analysis of extended X-ray absorption fine structure spectra, and bond strength calculation. In this way, we demonstrate that the mesoporous SnO 2 has a nano-engineering structure, inducing the facilitated electrochemical reaction and the weak Sn-O bond strength that would have an advantage in the additional conversion reaction as well as a void structure, relieving the severe volume changes during lithiation/delithiation. Consequently, excellent electrochemical performance is obtained in the mesoporous SnO 2 . Furthermore, insight from this research enables important advance in the development of metal oxide-based anode materials by making irreversible reaction reversible, providing a realizable strategy for the design and creation of high-energy storage devices.

25 ENERGY STORAGE↗

Open data set of live cyanobacterial cells imaged using an X-ray laser

Structural studies on living cells by conventional methods are limited to low resolution because radiation damage kills cells long before the necessary dose for high resolution can be delivered. X-ray free-electron lasers circumvent this problem by outrunning key damage processes with an ultra-short and extremely bright coherent X-ray pulse. Diffraction-before-destruction experiments provide high-resolution data from cells that are alive when the femtosecond X-ray pulse traverses the sample. This paper presents two data sets from micron-sized cyanobacteria obtained at the Linac Coherent Light Source, containing a total of 199,000 diffraction patterns. Utilizing this type of diffraction data will require the development of new analysis methods and algorithms for studying structure and structural variability in large populations of cells and to create abstract models. Such studies will allow us to understand living cells and populations of cells in new ways. New X-ray lasers, like the European XFEL, will produce billions of pulses per day, and could open new areas in structural sciences.

59 BASIC BIOLOGICAL SCIENCES↗

NAIS: Nuclear activation-based imaging spectroscopy

In recent years, the development of high power laser systems led to focussed intensities of more than 10{sup 22} W/cm{sup 2} at high pulse energies. Furthermore, both, the advanced high power lasers and the development of sophisticated laser particle acceleration mechanisms facilitate the generation of high energetic particle beams at high fluxes. The challenge of imaging detector systems is to acquire the properties of the high flux beam spatially and spectrally resolved. The limitations of most detector systems are saturation effects. These conventional detectors are based on scintillators, semiconductors, or radiation sensitive films. We present a nuclear activation-based imaging spectroscopy method, which is called NAIS, for the characterization of laser accelerated proton beams. The offline detector system is a combination of stacked metal foils and imaging plates (IP). After the irradiation of the stacked foils they become activated by nuclear reactions, emitting gamma decay radiation. In the next step, an autoradiography of the activated foils using IPs and an analysis routine lead to a spectrally and spatially resolved beam profile. In addition, we present an absolute calibration method for IPs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗