Search NASA⌕ Search

SEARCH · Search NASA

Results for “Capacity Loss”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Effect of temperature on microstructure and mechanical properties of ECAPed (TiB + La2O3)/Ti-6Al-4V composites

Highlights: • Dynamic recrystallization resulted in ultrafine grains near TiB interface region. • Tensile strength of ECAPed composites increased by up to 18%. • The average aspect ratio of TiB reduced with increasing ECAP temperature. • Interface debonding of TiB led to crack propagation and low ductility. TiB short fibers and La{sub 2}O{sub 3} particles reinforced titanium matrix composites (TMCs) were successfully equal-channel angular pressed (ECAPed) at 600 °C–900 °C. The effect of ECAP temperature on the microstructure and mechanical properties of the TMCs was investigated. The results indicated that dislocation tangling formed cell structures in matrix at lower ECAP temperature. In contrast, continuous dynamic recrystallization occurred at higher ECAP temperature, and promoted the formation of numerous new ultrafine grains. The average aspect ratio of TiB short fibers decreased with increasing ECAP temperature, which induced interfacial debonding. The tensile strength of TMCs ECAPed at 800 °C was up to 1128 MPa, which was 18% higher than the as-received composites. Interfacial debonding led TiB short fibers in low aspect ratios disabled to bear load, while the formation of ultrafine grains increased the strength of TMCs. The coupling of these two factors resulted in little effect of ECAP temperature on the tensile strength. However, the elongation of ECAPed TMCs generally decreased due to the loss of strain hardening capacity. Stress concentration tended to occur around the tips of TiB short fibers due to the interfacial debonding and cause crack propagation. It led to the premature fracture and low ductility.

36 MATERIALS SCIENCE↗

Boric acid removal with polyol-functionalized polyether membranes

Poor selectivity of conventional desalination membranes for boron often necessitates multi-stage treatment trains to achieve desired boron removal for end uses such as irrigation. One approach to membrane design for improved single-pass boric acid removal is via incorporation of chelating ligands that selectively sorb boron. In this study, membranes based on epoxy-amine cross-linked poly(glycidyl glycidyl ether) (PGGE) were synthesized and functionalized with N-methyl-d-glucamine (NMDG), a polyol known to interact selectively with boron. PGGE and PGGE-NMDG membranes exhibited boron sorption isotherms that were well-described by dual mode isotherms. PGGE-NMDG sorbed 2.5 mmol B/g dry polymer from a neutral aqueous solution containing 100 mmol B/L, which was almost three times the adsorption density of a commercial boron selective resin, Amberlite IRA743. Further, the membranes were regenerated in acid without a significant loss of boron sorption capacity over four cycles. Interactions between boron and NMDG and PGGE sites (e.g., epoxides) impacted boron diffusion in both membranes. The use of ligand functionalized membranes to capture target solutes such as boron requires high loading of interacting sites to maximize uptake capacity. Establishing fundamental structure/property rules for boron selectivity could lead to new material designs with improved boron separation properties for water purification.

36 MATERIALS SCIENCE↗

Understanding controls on redox processes in floodplain sediments of the Upper Colorado River Basin

Floodplains, heavily used for water supplies, housing, agriculture, mining, and industry, are important repositories of organic carbon, nutrients, and metal contaminants. The accumulation and release of these species is often mediated by redox processes. By understanding the physicochemical, hydrological, and biogeochemical controls on the distribution and variability of sediment redox conditions we can develop conceptual and numerical models of contaminant transport within floodplains. The Upper Colorado River Basin (UCRB) is impacted by former uranium and vanadium ore processing, resulting in contamination by V, Cr, Mn, As, Se, Mo and U. Previous authors have suggested that sediment redox activity occurring within organic carbon-enriched bodies located below the groundwater level may be regionally important to the maintenance and release of contaminant inventories, particularly uranium. To help assess this hypothesis, vertical distributions of Fe and S redox states and sulfide mineralogy were assessed in sediment cores from three floodplain sites spanning a 250 km transect of the central UCRB. Our results support the hypothesis that organic-enriched reduced sediments are important zones of biogeochemical activity within UCRB floodplains. Furthermore, we found that the presence of organic carbon, together with pore saturation, are the key requirements for maintaining reducing conditions, which were dominated by sulfate-reduction products. Sediment texture was found to be of secondary importance and to moderate the response of the system to external forcing, such as oxidant diffusion. Consequently, fine-grain sediments are relatively resistant to oxidation in comparison to coarser-grained sediments. Exposure to oxidants consumes precipitated sulfides, with a disproportionate loss of mackinawite (FeS) as compared to the more stable pyrite. The accompanying loss of redox buffering capacity creates the potential for release of sequestered radionuclides and metals. Because of their redox reactivity and stores of metals, C, and N, organic-enriched sediments are likely to be important to nutrient and contaminant mobility within UCRB floodplain aquifers.

54 ENVIRONMENTAL SCIENCES↗

Photo-oxidation of semicrystalline polymers: Effect of stress triaxiality on ductility

The effect of stress triaxiality on the strain-to-fracture of as-received and photo-oxidized polyamide-6 (PA-6) was investigated using mechanical testing, synchrotron X-ray tomography, and finite element analyses. Mechanical tests were conducted on cylindrical and round notched specimens, where different notch radii were used to vary the stress triaxiality. The specimens were aged by exposure to ultra-violet (UV) radiation at 60∘, causing photo-oxidation. As-received and so-aged specimens were loaded to failure (complete loss of load carrying capacity). For both unaged and aged specimens, a higher triaxiality led to a lower strain-to-fracture. To elucidate the micromechanical damage that mediates fracture in both conditions, specimens with an intermediate notch sharpness were loaded to the peak load, unloaded, and scanned ex situ using synchrotron X-ray tomography. Damage in the unaged bar was found to occur by cavitation and was concentrated at the center of the specimen, where the triaxiality is highest. In the UV-aged bar, a network of inter-connected chemical cracks were found on the notch surface, where the triaxiality is lowest. Finite element analyses were deployed to approximate the local triaxiality at damaged regions in the unaged and UV-aged specimens using a constitutive relation for semicrystalline polymers. From these analyses, the relationship between local triaxiality and strain-to-fracture was quantified for both unaged and photo-oxidized PA-6. Both unaged and photo-oxidized PA-6 showed similar decreases in ductility with triaxiality, hinting at common ductile fracture processes.

36 MATERIALS SCIENCE↗

The Impact of Lithium Anode Interface on Capacity Fade in Polymer Electrolyte-Based Solid-State Batteries

This study investigates the Li stripping-plating morphology and failure mechanisms in full cells consisting of a solid polymer electrolyte (SPE) with two commercial Li anodes: Li chip and Li foil. The primary identified failure mechanism of the SPE cell is capacity fade, regardless of the Li manufacturer. While the cathode’s role in capacity fade is evident, the Li anode significantly influences cycling performance, with Li foil cells cycling 50% longer than Li chip cells, a statistical difference. Further, post-mortem scanning electron microscopy and X-ray photoelectron spectroscopy results attribute the Li chip’s faster capacity fade to a loss of contact and continuous growth of the solid electrolyte interphase (SEI). Conversely, Li foil maintains consistent contact with the solid polymer, displaying a thin and stable SEI. Additionally, failure mechanisms between a gel electrolyte in previous work and the dry SPE are compared.

25 ENERGY STORAGE↗

Carbonate-H2O2 Leaching for Sequestering Uranium from Seawater

Uranium adsorbed on amidoxime-based polyethylene fiber in simulated seawater can be quantitatively eluted at room temperature using 1M Na2CO3 containing 0.1 M H2O2. This efficient elution process is probably due to formation of an extremely stable uranyl-peroxo-carbonato complex in the carbonate solution. After washing with water, the sorbent can be reused with little loss of uranium loading capacity. Possible existence of this stable uranyl species in ocean water is also discussed.

carbonate-peroxide leaching sequestering uranium s↗

Anisotropic magnetic and transport properties of orthorhombic o-Pr 2 Co 3 Ge 5

Abstract The crystal structure, electron energy-loss spectroscopy (EELS), heat capacity, and anisotropic magnetic and resistivity measurements are reported for Sn flux grown single crystals of orthorhombic Pr 2 Co 3 Ge 5 (U 2 Co 3 Si 5 -type, Ibam ). Our findings show that o -Pr 2 Co 3 Ge 5 hosts nearly trivalent Pr ions, as evidenced by EELS and fits to temperature dependent magnetic susceptibility measurements. Complex magnetic ordering with a partially spin-polarized state emerges near T sp = 32 K, with a spin reconfiguration transition near T M = 15 K. Heat capacity measurements show that the phase transitions appear as broad peaks in the vicinity of T sp and T M . The magnetic entropy further reveals that crystal electric field splitting lifts the Hund’s rule degeneracy at low temperatures. Taken together, these measurements show that Pr 2 Co 3 Ge 5 is an environment for complex f state magnetism with potential strongly correlated electron states.

36 MATERIALS SCIENCE↗

‘Birth defects’ of photosystem II make it highly susceptible to photodamage during chloroplast biogenesis

High solar flux is known to diminish photosynthetic growth rates, reducing biomass productivity and lowering disease tolerance. Photosystem II (PSII) of plants is susceptible to photodamage (also known as photoinactivation) in strong light, resulting in severe loss of water oxidation capacity and destruction of the water-oxidizing complex (WOC). The repair of damaged PSIIs comes at a high energy cost and requires de novo biosynthesis of damaged PSII subunits, reassembly of the WOC inorganic cofactors and membrane remodeling. Employing membrane-inlet mass spectrometry and O 2 -polarography under flashing light conditions, we demonstrate that newly synthesized PSII complexes are far more susceptible to photodamage than are mature PSII complexes. We examined these ‘PSII birth defects’ in barley seedlings and plastids (etiochloroplasts and chloroplasts) isolated at various times during de-etiolation as chloroplast development begins and matures in synchronization with thylakoid membrane biogenesis and grana membrane formation. We show that the degree of PSII photodamage decreases simultaneously with biogenesis of the PSII turnover efficiency measured by O 2 -polarography, and with grana membrane stacking, as determined by electron microscopy. Our data from fluorescence, Q B -inhibitor binding, and thermoluminescence studies indicate that the decline of the high-light susceptibility of PSII to photodamage is coincident with appearance of electron transfer capability Q$_A^-$ → QB during de-etiolation. This rate depends in turn on the downstream clearing of electrons upon buildup of the complete linear electron transfer chain and the formation of stacked grana membranes capable of longer-range energy transfer.

59 BASIC BIOLOGICAL SCIENCES↗

Analysis of Errors in Recording and Reading of a Holographic Prism on Photothermorefractive Glass

The influence of deviation of recording and reading conditions of multiplex Bragg gratings from calculated values on the parameters of restorable fan of beams of a holographic prism (HP) formed by Bragg gratings in photothermorefractive glass is analyzed. Deviations are specified either as a rotation of the sample around one of three orthogonal axes Oxyz or as simultaneous rotation of the sample around two axes. It is shown that errors in the sample installation do not affect quality of the HP in recording if all gratings are recorded with the same deviation from an ideal position. However, difference in errors at the recording of each grating results is a reduction of flatness of fan of the HP and a loss of its working capacity. Ultimate values of errors of rotation around the Ox and Oy axes allowing one to maintain HP functionality, i.e., simultaneous reconstruction of all its beams, are calculated. It is established that, in the case of an ideally recorded HP, errors in the stage of reading may result in twisting the fan and disrupting its flatness.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electrochemical Formation of Li-M-(M')-Si Phases Using Multivalent Electrolyte Salt Additives

Lithium-rich silicides (Li 15 Si 4 ), formed during the electrochemical lithiation of silicon, show high reactivity with electrolyte components that contribute to capacity decay, formal lithium loss, and low coulombic efficiency. Recently, the reactivity of lithium silicides was found to be suppressed by substituting a multivalent cation (i.e. Mg, Ca) for lithium that results in the room temperature formation of a ternary Li-M-Si phase. In this study, we explored a range of multivalent electrolyte salt additives (M = Ni, Cu, La, Ce, Sr, Ba, and Ca-Mg mixed salt) in a lithium-ion cell configuration and identified a room temperature electrochemical route to the formation of new ternary and quaternary lithium silicides. Using this method, both nickel and copper salts were found to plate onto the silicon electrode surface upon lithiation. Further, based on refined synchrotron XRD data, multivalent cations with an ionic radius similar to Na (~1.03 Å) or smaller can be inserted electrochemically into a formally cation-deficient Li 15 Si 4 host lattice to form new ternary (or quartenary) phases. The electrochemical synthesis of a new quaternary Li-M-M’-Si phase represents a facile route to preparing and scaling materials isostructural to the Heusler phase and electron-precise Li 14 MgSi 4 phase that results in enhanced cycling and calendar life performance.

25 ENERGY STORAGE↗

Harnessing Redox-Active Molecules in Alkylammonium Halide-Based Eutectic Solvents for Redox Flow Batteries

Redox flow batteries (RFBs) are promising for large-scale energy storage, however, advancements in performance and cost-effectiveness are critical factors for adoption. Here we report on alkylammonium halide based eutectic solvents (ESs) and found that a ESs comprising of diethylammonium chloride or bromide, in ethylene glycol demonstrated exceptional stability and a wide electrochemical stability window, making it a promising candidate for RFB applications. The electrochemical stability and redox behavior of the alkylammonium halide-based ESs are significantly influenced by hydrogen-bonding interactions, modulated by the alkyl chain length of the cation and the nature of the anion. A redox-active eutectic electrolyte containing 0.45 M methyl viologen dichloride (MV 2+ ) paired with acetylferrocene exhibited reversible redox behavior with a maximum open-circuit voltage of ∼1.34 V. The first redox couple, representing the viologen dication to radical cation transition, exhibited remarkable stability with consistent performance, achieving an energy efficiency near 70% at charge-discharge current densities of 10 mA cm −2 over 160 cycles with about 3% loss of the initial capacity. This study highlights the potential of alkylammonium halide DES systems for implementing eutectic-based RFB technologies in the future.

25 ENERGY STORAGE↗

Hydroxide Exchange Membrane Carbon Capture (HEMCC) Using Nickel Hydroxide Batteries and Flow-through Membranes

Proposed is an electrochemical nickel hydroxide based hydroxide exchange membrane carbon capture (HEMCC) device for Direct Air Capture (DAC) of CO2. DAC has been identified as one of the key net negative carbon technologies to achieve net zero carbon emissions. Net negative carbon technologies are required to offset continued emissions from dilute CO2 sources such as agriculture and construction. The majority of current DAC technologies at scale (>1 KT∙yr-1) are adsorbent based technologies with significant energy cost. The traditional DAC energy cost is primarily driven by the temperature swing required to regenerate the sorbent and has been shown to be 1.8 MWh·ton-1 at the system level. Electrochemical pH swing devices are a growing research area for carbon capture devices with the goal of lowering the energy cost required for DAC. A pH gradient is built by generating OH- at the cathode and consuming OH- at the anode. An acid-base equilibrium with CO2 allows for the capture of CO2 at the cathode and release at the anode. This extends from other electrochemical CO2 capture devices based on pKa shifts of an electrochemically active organic species allowing for the capture and release of CO2. Electrochemical CO2 capture is considered promising based on potentially low energy costs to capture CO2 in comparison with current temperature swing adsorption technologies. This work explores Ni(OH)2 electrodes to produce the pH gradient for CO2 capture and release. At the cathode NiOOH is reduced to Ni(OH)2 while at the anode Ni(OH)2 is oxidized to NiOOH. The symmetrical electrodes allow for a low voltage requirement; the thermodynamic potential difference of standard electrochemical reactions is zero. Most of the voltage observed is to produce the pH gradient with the remainder driving the polarization of the electrodes. There is a resistance component as well, but this is small in comparison due to the low current densities used in the device, nominally 2 mA·cm-1. Two similar devices are presented, a traditional MEA (membrane electrode assembly) and a flow-through MEA. The traditional MEA separates the two Ni(OH)2 electrodes with an 80μm Piperion® membrane. While the flow-through membrane separates the electrodes with a three piece membrane consisting of two 80μm Piperion® membranes with a porous membrane between them. In the traditional MEA system air is passed over the cathode for capture, while the flow-through MEA the air is passed through the porous membrane isolated from the electrodes. The traditional MEA has been used to establish a baseline performance of the device and has been shown to capture CO2 at an energy cost of 1 MWh·ton-1 at the device level. An understanding has been built around the components of that energy cost including the relationship of flux to current density, effect of a regeneration process, transient battery behavior, and gas losses coinciding with changing the polarization of the batteries. The flow-through MEA looks to address of transient battery behavior and gas losses. It allows for denser, higher capacity electrodes, which can lean on traditional Ni-MH battery technology used in alkaline batteries used today. The higher capacities, limit the transient battery effect on flux in the device. Gas losses are addressed by having a continuous inlet air stream to the device and continuous outlet product.

Buchen, James↗

Analysis of Microbial Communities as Indicators of Microbially Induced Corrosion Potential in Stainless Steel Piping

The 200 West Area Pump-and-Treat (200W P&T) facility is part of the final remedy decision for the 200 ZP-1 Operable Unit (OU) and is the interim remedial action for 200-UP-1 OU at the Hanford Site. The facility also treats water from other sources across the site, including 200-DV-1 OU perched water, groundwater from the 200-BP-5 OU, and leachate from the Environmental Restoration Disposal Facility. The facility originally operated a biological treatment process for nitrate that resulted in systemic biofouling and loss of injection well capacity, requiring frequent and costly well rehabilitation. Biofouling has also contributed to corrosion of welds and pitting of stainless-steel piping at the facility. The biological treatment for nitrate was suspended at the end of 2019 calendar year to eliminate negative impacts from biological treatments which improve facility operations and treatment of carbon tetrachloride. Evaluation of the 200W P&T facility’s response to operational improvements, specifically the suspension of the biological treatment, provides information on the potential for continued microbially induced corrosion (MIC). To this end, historical data sets (2015-2017) were compared with molecular biological analyses of 200W P&T water samples from 2018-2020 to quantify trends in total microbial biomass and specific microbial indicator species (iron, sulfate, nitrate, and manganese reducing bacteria) known to cause and enhance metal corrosion. Results showed unequivocal reductions (in excess of 90%) in all microbiological indicators measured following the suspension of the biological treatment. Although abundance measurements for all corrosive MIC populations initially declined after removal of the treatment system, nitrate-reducing bacteria (nirK) and sulfate-reducing bacteria remain highly abundant in the system, an order of magnitude higher than the number of cells present prior to the removal of the biological treatment system [5.14e (1.4) cells/L, vs. 1.14e (0.07) cells/L, reported as average (±SD) for n=3]. In addition, there was an unexpected inflection point in 2019 where all microbial indicators increased unexpectedly in abundance in 2020 by as much as two orders of magnitude compared to 2019 samples. Given the limited number of water samples available for this analysis, the cause of the increase in microbial indicators post-biological treatment has not yet been determined. Systematic sampling of the facility for continued monitoring is recommended so that the responses of MIC populations can be evaluated to ensure that further corrosion is avoided, allowing the 200W P&T facility to operate safely and efficiently at design capacity.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Generation Plant Cost of Operations and Cycling Optimization Model (Final Technical Report)

Modern coal plants are a masterpiece of engineering, having been refined and improved over more than a century. As they evolved, they have grown more efficient and cleaner. At the same time, they have grown much larger and increasingly designed to operate on very specific fuels at or near the maximum capacity, providing baseload power. In recent decades, however, they have been called on to operate at reduced capacity (cycled) at a loss of efficiency and possibly accelerated wear and tear. The purpose of this project was to develop a model to accurately estimate the cost of cycling large coal plants so that they can be operated efficiently as part of a comprehensive strategy for generation planning and dispatch. The final goal is a model which is commercial-ready that can be “tuned” to different plants for widespread use.

20 FOSSIL-FUELED POWER PLANTS↗

Impact of wetland decline on decreasing dissolved organic carbon concentrations along the Mississippi River continuum

Prior to discharging to the ocean, large rivers constantly receive inputs of dissolved organic carbon (DOC) from tributaries or fringing floodplains and lose DOC via continuous in situ processing along distances that span thousands of kilometers. Current concepts predicting longitudinal changes in DOC mainly focus on in situ processing or exchange with fringing floodplain wetlands, while effects of heterogeneous watershed characteristics are generally ignored. We analyzed results from a 17-year time-series of DOC measurements made at seven sites and three expeditions along the entire Mississippi River main channel with DOC measurements made every 17 km. The results show a clear downstream decrease in DOC concentrations that was consistent throughout the entire study period. Downstream DOC decreases were primarily (~63–71%) a result of constant dilutions by low-DOC tributary water controlled by watershed wetland distribution, while in situ processing played a secondary role. We estimate that from 1780 to 1980 wetland loss due to land-use alterations caused a ca. 58% decrease in in DOC concentrations in the tributaries of the Mississippi River. DOC reductions caused by watershed wetland loss likely impacted the capacity for the river to effectively remove nitrogen via denitrification, which can further exacerbate coastal hypoxia. Lastly, these findings highlight the importance of watershed wetlands in regulating DOC longitudinally along the headland to ocean continuum of major rivers.

54 ENVIRONMENTAL SCIENCES↗

Modelled land use and land cover change emissions – a spatio-temporal comparison of different approaches

Abstract. Quantifying the net carbon flux from land use and land cover changes (fLULCC) is critical for understanding the global carbon cycle and, hence, to support climate change mitigation. However, large-scale fLULCC is not directly measurable and has to be inferred from models instead, such as semi-empirical bookkeeping models and process-based dynamic global vegetation models (DGVMs). By definition, fLULCC estimates are not directly comparable between these two different model types. As an important example, DGVM-based fLULCC in the annual global carbon budgets is estimated under transient environmental forcing and includes the so-called loss of additional sink capacity (LASC). The LASC results from the impact of environmental changes on land carbon storage potential of managed land compared to potential vegetation and accumulates over time, which is not captured in bookkeeping models. The fLULCC from transient DGVM simulations, thus, strongly depends on the timing of land use and land cover changes mainly because LASC accumulation is cut off at the end of the simulated period. To estimate the LASC, the fLULCC from pre-industrial DGVM simulations, which is independent of changing environmental conditions, can be used. Additionally, DGVMs using constant present-day environmental forcing enable an approximation of bookkeeping estimates. Here, we analyse these three DGVM-derived fLULCC estimations (under transient, pre-industrial, and present-day forcing) for 12 models within 18 regions and quantify their differences as well as climate- and CO2-induced components and compare them to bookkeeping estimates. Averaged across the models, we find a global fLULCC (under transient conditions) of 2.0±0.6 PgC yr−1 for 2009–2018, of which ∼40 % are attributable to the LASC (0.8±0.3 PgC yr−1). From 1850 onward, the fLULCC accumulated to 189±56 PgC with 40±15 PgC from the LASC. Around 1960, the accumulating nature of the LASC causes global transient fLULCC estimates to exceed estimates under present-day conditions, despite generally increased carbon stocks in the latter. Regional hotspots of high cumulative and annual LASC values are found in the USA, China, Brazil, equatorial Africa, and Southeast Asia, mainly due to deforestation for cropland. Distinct negative LASC estimates in Europe (early reforestation) and from 2000 onward in the Ukraine (recultivation of post-Soviet abandoned agricultural land), indicate that fLULCC estimates in these regions are lower in transient DGVM compared to bookkeeping approaches. Our study unravels the strong dependence of fLULCC estimates on the time a certain land use and land cover change event happened to occur and on the chosen time period for the forcing of environmental conditions in the underlying simulations. We argue for an approach that provides an accounting of the fLULCC that is more robust against these choices, for example by estimating a mean DGVM ensemble fLULCC and LASC for a defined reference period and homogeneous environmental changes (CO2 only).

54 ENVIRONMENTAL SCIENCES↗

A high reliability battery management system

Over a period of some 5 years Canadian Astronautics Limited (CAL) has developed a system to autonomously manage, and thus prolong the life of, secondary storage batteries. During the development, the system was aimed at the space vehicle application using nickel cadmium batteries, but is expected to be able to enhance the life and performance of any rechargeable electrochemical couple. The system handles the cells of a battery individually and thus avoids the problems of over, and under, drive that inevitably occur in a battery of cells managed by an averaging system. This individual handling also allow cells to be totally bypassed in the event of failure, thus avoiding the losses associated with low capacity, partial short circuit, and the catastrophe of open circuit. The system has an optional capability of managing redundant batteries simultaneously, adding the advantage of on line reconditioning of one battery, while the other maintains the energy storage capability of the overall system. As developed, the system contains a dedicated, redundant, microprocessor, but the capability exists to have this computing capability time shared, or remote, and operating through a data link. As adjuncts to the basic management system CAL has developed high efficiency, polyphase, power regulators for charge and discharge power conditioning.

Moody, M. H.↗

Traffic placement policies for a multi-band network

Recently protocols were introduced that enable the integration of synchronous traffic (voice or video) and asynchronous traffic (data) and extend the size of local area networks without loss in speed or capacity. One of these is DRAMA, a multiband protocol based on broadband technology. It provides dynamic allocation of bandwidth among clusters of nodes in the total network. A number of traffic placement policies for such networks are proposed and evaluated. Metrics used for performance evaluation include average network access delay, degree of fairness of access among the nodes, and network throughput. The feasibility of the DRAMA protocol is established through simulation studies. DRAMA provides effective integration of synchronous and asychronous traffic due to its ability to separate traffic types. Under the suggested traffic placement policies, the DRAMA protocol is shown to handle diverse loads, mixes of traffic types, and numbers of nodes, as well as modifications to the network structure and momentary traffic overloads.

Maly, Kurt J.↗