Search NASA⌕ Search

SEARCH · Search NASA

Results for “Charged Particle”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Collisionless relativistic magnetic reconnection driven by electron vortices in laser-plasma interaction

Magnetic reconnection (MR) is a fundamental process in space and laboratory plasmas. The appearance of high power lasers opens a new way to investigate MR under the relativistic condition. In this paper, relativistic collisionless MR driven by two ultra-intense lasers and a pair of asymmetric targets is studied numerically via the kinetic simulations. The static magnetic fields produced by the electron vortex structures with opposite magnetic polarities approach each other driven by the magnetic pressure and the density gradient. The antiparallel magnetic fields annihilate accompanied with the topological variation and the corresponding magnetic field energy is being dissipated to the kinetic energy of the nonthermal charged particles. Besides the outflows along the current sheet, a fast particle bunch is accelerated perpendicularly contributed by the displacement current.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Verification of nonperturbative guiding center theory in symmetric fields

We verify a recently-developed nonperturbative guiding center formalism to charged particle dynamics in fields with two-parameter continuous symmetry groups. This entails finding exact constants of motion, valid in the nonperturbative regime, that agree with Kruskal’s adiabatic invariant series to all orders in the perturbative regime, when the field scale length is large compared with a typical gyroradius. We demonstrate that the nonperturbative guiding center model makes exact predictions in these cases, even though it eliminates the cyclotron timescale, thereby establishing a theoretical baseline for performance of the nonperturbative formalism.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A linked-scale coupled model of mass erosion and redistribution in plasma-exposed micro-foam surfaces

Surface evolution due to exposure to harsh environments is of importance in many scientific and technological applications. In plasma-exposed materials, the surface receives charged particles from the plasma, leading to a series of processes that drive the system far from equilibrium and may lead to the severe deterioration of the surface properties. Although surface morphological changes are driven by atomic collisions taking place over picoseconds and nanometers, these processes result in mass loss and redistribution of matter over much larger length and time scales. This necessitates a multi-scale approach capable of capturing the range of processes linking primary atomic collision events with engineering-level surface geometry changes. In this paper, we develop a computational model to simulate the morphological evolution and effective erosion rate of micro-architected tungsten foams during low-energy plasma ion bombardment. Furthermore, the model acts on several length scales, with the energy and angular dependence of the sputtering yield of flat tungsten surfaces determined using the SRIM code based on the binary collision approximation. This information is introduced into a low-fluence, short-term Monte Carlo raytracing model, and further into a high-fluence, long-term particle transport model. In the latter, material particles representing billions of atoms are described in a digitized 3-D representation of the foam structure from X-ray tomography data, and are sputtered off and redeposited using the atomistic information. We show that the redeposition of sputtered atoms leads to partial self-healing in the bottom layers with a sharp reduction in the sputtering coefficient of low density foams, roughly 25% of the solid W value. This is in qualitative agreement with recent experiments on low porosity W structures. At high fluence, the foam structure degrades considerably as there are fewer ligaments available to recapture sputtered atoms and, consequently, the sputtering rate increases again.

36 MATERIALS SCIENCE↗

Characterization and qualification of neutron radiation effects – Summary of Japan-USA Joint Projects for 40 years

The Joint Projects under the Japan-USA Fusion Cooperation Program started in 1981 and has continued for more than 40 years. In the Joint Projects, although a wide range of fusion materials and engineering issues were covered, neutron radiation effects on fusion reactor materials have always been the major research emphases, and the neutron irradiation facilities in the US were jointly used by Japanese and US researchers. Japanese test facilities including neutron and charged particle irradiation facilities were complementarily used. Here, the initial focus of the Joint Projects was on fundamental fusion neutron radiation effects and irradiation correlation. Systematic comparison of fission and fusion radiation effects in comparable damage levels and the effects of transmutation-induced helium were investigated. The collaboration was then focused on the effect of dynamic irradiation effects in variable conditions. In addition to the relatively fundamental studies, the Joint Projects contributed largely to development of candidate materials such as RAFM steels, vanadium alloys, SiC/SiC composites, and tungsten alloys, through a mechanism-oriented approach. The Joint Projects also covered issues specific to materials application to fusion blankets and plasma-facing components, including neutron radiation effects such as tritium retention and permeation of neutron-irradiated plasma-facing materials. Various irradiation technologies were developed and applied to the irradiation experiments, including those for in-situ testing.Considering that high energy neutron sources, such as A-FNS and IFMIF-DONES, now have high viability, the research supporting the neutron source programs is essential. The knowledge obtained through the Joint Projects is valuable and should be advanced for this purpose. To this end, it is of urgent necessity to launch an international scientific program accumulating knowledge of fusion neutron radiation effects, including their fundamental aspects.

36 MATERIALS SCIENCE↗

ENDF/B-VIII.1: Updated Nuclear Reaction Data Library for Science and Applications

The ENDF/B-VIII.1 library is the newest recommended evaluated nuclear data file by the Cross Section Evaluation Working Group (CSEWG) for use in nuclear science and technology applications, and incorporates advances made in the six years since the release of ENDF/B-VIII.0. Among key advances made are that the 239 Pu file was reevaluated by a joint international effort and that updated 16,18 O, 19 F, 28–30 Si, 50–54 Cr, 55 Mn, 54,56,57 Fe, 63,65 Cu, 139 La, 233,235,238 U, and 240,241 Pu neutron nuclear data from the IAEA coordinated INDEN collaboration were adopted. Over 60 neutron dosimetry cross sections were adopted from the IAEA's IRDFF-II library. In addition, the new library includes significant changes for 3 He, 6 Li, 9 Be, 51 V, 88 Sr, 103 Rh, 140,142 Ce, Dy, 181 Ta, Pt, 206–208 Pb, and 234,236 U neutron data, and new nuclear data for the photonuclear, charged-particle and atomic sublibraries. Numerous thermal neutron scattering kernels were reevaluated or provided for the very first time. On the covariance side, work was undertaken to introduce better uncertainty quantification standards and testing for nuclear data covariances. The significant effort to reevaluate important nuclides has reduced bias in the simulations of many integral experiments with particular progress noted for fluorine, copper, and stainless steel containing benchmarks. Data issues hindered the successful deployment of the previous ENDF/B-VIII.0 for commercial nuclear power applications in high burnup situations. These issues were addressed by improving the 238 U and 239,240,241 Pu evaluated data in the resonance region. The new library performance as a function of burnup is similar to the reference ENDF/B-VII.1 library.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The CLAS12 drift chamber system

The CEBAF Large Acceptance Spectrometer at 12~GeV (CLAS12) is located in Hall~B, one of the experimental halls at Jefferson Lab. The forward part of CLAS12 is built around a superconducting toroidal magnet. The six coils of the toroid divide the detector azimuthally into six sectors. Each sector contains three multi-layer drift chambers for reconstructing the trajectories of charged particles originating from a fixed target. Each of the 18 planar chambers has two ``superlayers'' of six layers each, with the wires in the two adjacent superlayers oriented at ± 6° stereo angles. Each layer has 112 hexagonal cells spanning a range from about 5° to 40° in polar angle. The six-layer structure provides redundancy in track segment finding and good tracking efficiency even in the presence of some individual wire inefficiency. The design, construction, operation, and calibration methods are described, and estimates of the efficiency and resolution are presented from in-beam measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The STAR event plane detector

The Event Plane Detector (EPD) is an upgrade detector to the STAR experiment at RHIC, designed to measure the pattern of forward-going charged particles emitted in a high-energy collision between heavy nuclei. It consists of two highly-segmented disks of 1.2-cm-thick scintillator embedded with wavelength-shifting fiber, coupled to silicon photomultipliers and custom electronics. Finally, we describe the general design of the device, its construction, and performance on the bench and in the experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fast-neutron response of LaBr 3 (Ce) and LaCl 3 (Ce) scintillators

The response of LaBr 3 (Ce) and LaCl 3 (Ce) scintillators to fast neutrons is investigated. Neutron-induced charged-particle reactions are observed in both materials when exposed to the fast neutrons produced by an AmBe source, with pulse-shape discrimination used to separate channels. LaBr 3 (Ce) is found to have the best separation between reaction channels, while LaCl 3 (Ce) has a significantly higher efficiency.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The CLAS12 Backward Angle Neutron Detector (BAND)

The Backward Angle Neutron Detector (BAND) of CLAS12 detects neutrons emitted at backward angles of 155° to 175°, with momenta between 200 and 600 MeV$/c_0$. It is positioned 3-m upstream of the target, consists of 18 rows and 5 layers of 7.2-cm by 7.2-cm scintillator bars, and read out on both ends by PMTs to measure time and energy deposition in the scintillator layers. Between the target and BAND there is a 2-cm thick lead wall followed by a 2-cm veto layer to suppress gammas and reject charged particles. This paper discusses the component-selection tests and the detector assembly. Timing calibrations (including offsets and time-walk) were performed using a novel pulsed-laser calibration system, resulting in time resolutions better than 250 ps (150 ps) for energy depositions above 2 MeV (5 MeV). Cosmic rays and a variety of radioactive sources were used to calibration the energy response of the detector. Scintillator bar attenuation lengths were measured. We report the time resolution results in a neutron momentum reconstruction resolution, $δp/p$ < 1.5% for neutron momentum 200 ≤ $p$ ≤ 600 MeV/c. Final performance of the BAND with CLAS12 is shown, including electron–neutral particle timing spectra and a discussion of the off-time neutral contamination as a function of energy deposition threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CsI calorimeter for the J-PARC KOTO experiment

An electromagnetic calorimeter made of undoped CsI crystals is used in the J-PARC KOTO experiment to search for new physics beyond the standard model with the KL → π 0 νν¯ decay. The calorimeter is designed to operate in vacuum of 0.1 Pa and in a high-rate environment where the counting rate due to KL decays is O(100) kHz. A special method to calibrate the calorimeter during the data taking without using a tracking system for charged particles is reported. The energy, position, and timing resolutions of the calorimeter were evaluated in several beam tests, and the resolutions satisfy the required performance. Finally, the energy resolution with the total energy E is 0.66 ⊕ 1.81/ √ E[GeV]% in the inner region of the calorimeter.

47 OTHER INSTRUMENTATION↗

Fast dynamic aperture optimization with forward-reversal integration

A fast dynamic aperture (DA) optimization method for storage rings has been developed through the use of reversal integration. Even if dynamical systems have an exact reversal symmetry, a numerical forward integration differs from its reversal. For a chaotic trajectory, cumulative round-off errors are scaled, which results in an exponential growth on the difference. The exponential effect is a generic chaos indicator which represents the sensitivity of the chaotic motion to its initial condition. The chaos indicator of the charged particle motion can be obtained by comparing the forward integrations of particle trajectories with corresponding reversals, a.k.a. “backward integrations.” The indicator is observable even through short-term particle tracking simulations. Therefore, adopting it as an objective function could speed up optimization. Finally, the DA of the National Synchrotron Light Source II storage ring, and another test diffraction-limited light source ring, were optimized using this method for the purpose of demonstration.

43 PARTICLE ACCELERATORS↗

On the analysis of signal peaks in pulse-height spectra

The estimation of the signal location and intensity of a peak in a pulse height spectrum is important for X- ray and γ-ray spectroscopy, charged-particle spectrometry, liquid chromatography, and many other subfields. However, both the ‘‘centroid’’ and ‘‘signal intensity’’ of a peak in a pulse-height spectrum are ill-defined quantities and different methods of analysis will yield different numerical results. Here, we apply three methods of analysis. Method A is based on simple count summation and is likely the technique most frequently applied in practice. The analysis is straightforward and fast, and does not involve any statistical modeling. We find that it provides reliable results only for high signal-to-noise data, but has severe limitations in all other cases. Method B employs a Bayesian model to extract signal counts and centroid from the measured total and background counts. The resulting values are derived from the respective posteriors and, therefore, have a rigorous statistical meaning. The method makes no assumptions about the peak shape. It yields reliable and relatively small centroid uncertainties. However, it provides relatively large signal count uncertainties. Method C makes a strong assumption regarding the peak shape by fitting a Gaussian function to the data. Furthermore, the fit is based again on a Bayesian model. Although Method C requires careful consideration of the Gaussian width (usually given by the detector resolution) used in the fitting, it provides reliable values and relatively small uncertainties both for the signal counts and the centroid.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High precision real-time insertion device and monochromator synchronization at NSLS-II

We report that insertion devices have become the dominant photon source at synchrotron and free electron laser light source facilities the world over. Undulators, characterized by their small deflection parameter, exhibit a high degree of constructive interference in photon production from high energy charged particle beams leading to very high photon rates at specific harmonics of the fundamental frequency with relatively narrow spectral widths. Spectroscopic measurements of interest typically span several of these harmonic widths, which requires precision adjustment of an undulator’s magnetic gap to maintain peak flux within the much narrower bandwidth of a beamline monochromator at the desired energy. High precision insertion device controls are developed at NSLS-II including real-time linked control of monochromator hardware allowing for fast, high precision, hardware triggered, spectroscopic measurements. Furthermore, this fast fly scan method is described, compared statistically for self consistency, and shown to be far superior in both efficiency and accuracy as compared to standard step scan measurements.

36 MATERIALS SCIENCE↗

CoSyR: A novel beam dynamics code for the modeling of synchrotron radiation effects

The self-consistent nonlinear dynamics of a relativistic charged particle beam interacting with its complete self-fields is a fundamental problem underpinning many of the accelerator design issues in high brightness beam applications, as well as the development of advanced accelerators. Particularly, synchrotron radiation induced effects in a magnetic dispersive beamline element can lead to collective beam instabilities and emittance growth. A novel beam dynamics code is developed based on a Lagrangian method for the calculation of the particles’ radiation near-fields using wavefront/wavelet meshes via the Green’s function of the Maxwell equations. These fields are then interpolated onto a moving mesh for dynamic update of the beam. This method allows radiation co-propagation and self-consistent interaction with the beam in 2D/3D simulations at greatly reduced numerical errors. Multiple levels of parallelisms are inherent in this method and implemented in our code CoSyR to enable at-scale simulations of nonlinear beam dynamics on modern computing platforms using MPI, multi-threading, and GPUs. Here, the current 2D implementation of CoSyR has been used to evaluate the transverse and longitudinal coherent radiation effects on the beam and to investigate beam optics designs proposed for mitigation of beam brightness degradation in a magnetic bunch compressor. In this paper, the design of CoSyR, as well as the benchmark with other coherent synchrotron radiation models, are described and discussed. Extension of the core algorithms to 3D is possible and planned.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantification of the light output anistropy in deuterated stilbene

Deuterated stilbene is an organic scintillator that is a desirable material for fast neutron spectroscopy using spectrum unfolding techniques without requiring time-of-flight information. Due to the crystal structure of the material, some anisotropy of the light output exists, which is dependent on the direction of heavy charged particle recoil relative to the crystal structure. The anisotropy of trans-stilbene (hereafter referred to as stilbene) has been well characterized in previous work, but for deuterated stilbene, the anisotropy has only been partially characterized along the a and b crystal axes, while the artificial c' axis, which shows the largest anisotropy in stilbene, has not been characterized until this publication. Here, in this work, two deuterated stilbene crystals were characterized with neutron energies up to 35 MeV at the Los Alamos Neutron Science Center. For one of the crystals, the response is characterized along the a, b, and c' axes. This characterization shows a distinct anisotropy along the axes in deuterated stilbene, which is very similar to that found in regular stilbene, such that the a axis is the brightest, while the b' and c' axes are approximately 3% and 20%–35% lower relative to the a axis.

36 MATERIALS SCIENCE↗

PICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging

The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged particles in ionization gaps by using extreme UV Cherenkov light emitted in a crystal, detected by a Micromegas photodetector with an appropriate photocathode. The first single-channel prototype tested in 150 GeV/c muon beams achieved a timing resolution below 25 ps, a significant improvement compared to standard Micropattern Gaseous Detectors (MPGDs). This work explores the specifications for applying these detectors in monitored neutrino beams for the ENUBET Project. Key aspects include exploring resistive technologies, resilient photocathodes, and scalable electronics. New 7-pad resistive detectors are designed to handle the particle flux. In this paper, two potential scenarios are briefly considered: tagging electromagnetic showers with a timing resolution below 30ps in an electromagnetic calorimeter as well as individual particles (mainly muons) with about 20ps respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HRPPD photosensors for RICH detectors with a high resolution timing capability

Recently, a new version of DC-coupled High Rate Picosecond Photodetectors (DC-HRPPDs) substantially re-designed for use at the Electron-Ion Collider (EIC) has been developed. A first batch of seven “EIC HRPPDs” was manufactured in early 2024. These HRPPDs are DC-coupled photosensors based on Micro-Channel Plates (MCPs) that have an active area of 104 mm by 104 mm, 32 × 32 direct readout pixel array at a pitch of 3.25 mm, peak quantum efficiency in excess of 30%, exceptionally low dark count rates and timing resolution of 15–20 ps for a single photon detection. As such, these photosensors are very well suited for Ring Imaging CHerenkov (RICH) detectors that can additionally provide high resolution timing capability, especially in a configuration where a detected charged particle passes through the sensor window, which produces a localized flash containing a few dozens of Cherenkov photons in it.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The ladder and readout cables of intermediate silicon strip detector for sPHENIX

A new silicon-strip-type detector was developed for precise charged-particle tracking in the central rapidity region of heavy ion collisions. A new detector and collaboration at the Relativistic Heavy Ion Collider at Brookhaven National Laboratory is sPHENIX, which is a major upgrade of the PHENIX detector. The intermediate tracker (INTT) is part of the advanced tracking system of the sPHENIX detector complex together with a CMOS monolithic-active-pixel-sensor based silicon-pixel vertex detector, a time-projection chamber, and a micromegas-based detector. The INTT detector is barrel shaped and comprises 56 silicon ladders. Two different types of strip sensors of 78 micron pitch and 320 micron thick are mounted on each half of a silicon ladder. Each strip sensor is segmented into 8 × 2 and 5 × 2 blocks with lengths of 16 and 20 mm. Strips are read out with a silicon strip-readout (FPHX) chip. In order to transmit massive data from the FPHX to the down stream readout electronics card (ROC), a series of long and high speed readout cables were developed. This document focuses on the silicon ladder, the readout cables, and the ROC of the INTT. The radiation hardness is studied for some parts of the INTT devices in the last part of this document, since the INTT employed some materials from the technology frontier of the industry whose radiation hardness is not necessarily well known.

43 PARTICLE ACCELERATORS↗