Search NASA⌕ Search

SEARCH · Search NASA

Results for “Coherent Diffractive Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

High Heat Load Diamond Monochromator Project at ESRF

Due to its outstanding thermal properties, diamond is an attractive alternative to silicon as a monochromator material for high intensity X-ray beams. To date, however, the practical applications have been limited by the small size and relatively poor crystallographic quality of the crystals available. The ESRF Diamond Project Group has studied the perfection of diamonds in collaboration with industry and universities. The group has also designed and tested different stress-free mounting techniques to integrate small diamonds into larger X-ray optical elements. We now propose to develop a water-cooled Bragg-Bragg double crystal monochromator using diamond (111) crystals. It will be installed on the ESRF undulator beamline, ID06, for testing under high heat load. This monochromator will be best suited for the low energy range, typically from {approx}3.4 keV to 15 keV, due to the small size of the diamonds available and the size of the beam footprint. This paper presents stress-free mounting techniques studied using X-ray diffraction imaging, and their thermal-mechanical analysis by finite element modelling, as well as the status of the ID06 monochromator project.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-F-CAMPUS-I-03: Tissue Equivalent Material Phantom to Test and Optimize Coherent Scatter Imaging for Tumor Classification

Purpose: To accurately model different breast geometries using a tissue equivalent phantom, and to classify these tissues in a coherent x-ray scatter imaging system. Methods: A breast phantom has been designed to assess the capability of coded aperture coherent x-ray scatter imaging system to classify different types of breast tissue (adipose, fibroglandular, tumor). The tissue-equivalent phantom was modeled as a hollow plastic cylinder containing multiple cylindrical and spherical inserts that can be positioned, rearranged, or removed to model different breast geometries. Each enclosure can be filled with a tissue-equivalent material and excised human tumors. In this study, beef and lard, placed inside 2-mm diameter plastic Nalgene containers, were used as surrogates for fibroglandular and adipose tissue, respectively. The phantom was imaged at 125 kVp, 40 mA for 10 seconds each with a 1-mm pencil beam. The raw data were reconstructed using a model-based reconstruction algorithm and yielded the location and form factor, or momentum transfer (q) spectrum of the materials that were imaged. The measured material form factors were then compared to the ground truth measurements acquired by x-ray diffraction (XRD) imaging. Results: The tissue equivalent phantom was found to accurately model different types of breast tissue by qualitatively comparing our measured form factors to those of adipose and fibroglandular tissue from literature. Our imaging system has been able to define the location and composition of the various materials in the phantom. Conclusion: This work introduces a new tissue equivalent phantom for testing and optimization of our coherent scatter imaging system for material classification. In future studies, the phantom will enable the use of a variety of materials including excised human tissue specimens in evaluating and optimizing our imaging system using pencil- and fan-beam geometries. United States Department of Homeland Security Duke University Medical Center - Department of Radiology Carl E Ravin Advanced Imaging Laboratories Duke University Medical Physics Graduate Program.

60 APPLIED LIFE SCIENCES↗

All-optical photochromic spatial light modulators based on photoinduced electron transfer in rigid matrices

A single material (not a multi-element structure) spatial light modulator may be written to, as well as read out from, using light. The device has tailorable rise and hold times dependent on the composition and concentration of the molecular species used as the active components. The spatial resolution of this device is limited only by light diffraction as in volume holograms. The device may function as a two-dimensional mask (transmission or reflection) or as a three-dimensional volume holographic medium. This device, based on optically-induced electron transfer, is able to perform incoherent to coherent image conversion or wavelength conversion over a wide spectral range (ultraviolet, visible, or near-infrared regions).

Beratan, David N.↗

Conical Intersection Passages of Molecules Probed by X-ray Diffraction and Stimulated Raman Spectroscopy

Conical intersections (CoIns) play an important role in ultrafast relaxation channels. Their monitoring remains a formidable experimental challenge. We theoretically compare the probing of the S 2 → S 1 CoIn passage in 4-thiouracil by monitoring its vibronic coherences, using off-resonant X-ray-stimulated Raman spectroscopy (TRUECARS) and time resolved X-ray diffraction (TRXD). The quantum nuclear wavepacket (WP) dynamics provides an accurate picture of the photoinduced dynamics. Upon photoexcitation, the WP oscillates among the Franck–Condon point, the S2 minimum, and the CoIn with a 70 fs period. A vibronic coherence first emerges at 20 fs and can be observed until the S 2 state is fully depopulated. The distribution of the vibronic frequencies involved in the coherence is recorded by the TRUECARS spectrogram. Here, the TRXD signal provides spatial images of electron densities associated with the CoIn. In combination, the two signals provide a complementary picture of the nonadiabatic passage, which helps in the study of the underlying photophysics in thiobases.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental strategies for imaging bioparticles with femtosecond hard X-ray pulses

This study explores the capabilities of the Coherent X-ray Imaging Instrument at the Linac Coherent Light Source to image small biological samples. The weak signal from small samples puts a significant demand on the experiment. Aerosolized Omono River virus particles of ~40 nm in diameter were injected into the submicrometre X-ray focus at a reduced pressure. Diffraction patterns were recorded on two area detectors. The statistical nature of the measurements from many individual particles provided information about the intensity profile of the X-ray beam, phase variations in the wavefront and the size distribution of the injected particles. The results point to a wider than expected size distribution (from ~35 to ~300 nm in diameter). This is likely to be owing to nonvolatile contaminants from larger droplets during aerosolization and droplet evaporation. The results suggest that the concentration of nonvolatile contaminants and the ratio between the volumes of the initial droplet and the sample particles is critical in such studies. The maximum beam intensity in the focus was found to be 1.9 × 10 12 photons per µm 2 per pulse. The full-width of the focus at half-maximum was estimated to be 500 nm (assuming 20% beamline transmission), and this width is larger than expected. Under these conditions, the diffraction signal from a sample-sized particle remained above the average background to a resolution of 4.25 nm. Finally, the results suggest that reducing the size of the initial droplets during aerosolization is necessary to bring small particles into the scope of detailed structural studies with X-ray lasers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards high-resolution ptychographic x-ray diffraction microscopy

Ptychographic x-ray diffraction microscopy is a lensless imaging technique with a large field of view and high spatial resolution, which is also useful for characterizing the wavefront of an x-ray probe. The performance of this technique is degraded by positioning errors due to the drift between the sample and illumination optics. We propose an experimental approach for correcting the positioning errors and demonstrate success by two-dimensionally reconstructing both the wavefront of the focused x-ray beam and the complex transmissivity of the weakly scattering objects at the pixel resolution of better than 10 nm in the field of view larger than 5 {mu}m. This method is applicable to not only the observation of organelles inside cells or nano-mesoscale structures buried within bulk materials but also the characterization of probe for single-shot imaging with x-ray free electron lasers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Wave and Particle in Molecular Interference Lithography

The wave-particle duality of massive objects is a cornerstone of quantum physics and a key property of many modern tools such as electron microscopy, neutron diffraction or atom interferometry. Here we report on the first experimental demonstration of quantum interference lithography with complex molecules. Molecular matter-wave interference patterns are deposited onto a reconstructed Si(111) 7x7 surface and imaged using scanning tunneling microscopy. Thereby both the particle and the quantum wave character of the molecules can be visualized in one and the same image. This new approach to nanolithography therefore also represents a sensitive new detection scheme for quantum interference experiments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Theory of x-ray diffraction from laser-aligned molecules.

We present the theory of x-ray diffraction from an ensemble of symmetric-top molecules aligned by an intense optical laser pulse at finite rotational temperature. Using QED, the x-ray/molecule interaction is treated as an electronically elastic one-photon scattering process. In the practically important case that the x-ray pulse is quasi-monochromatic and its coherence time is much shorter than the time scale of molecular rotational dynamics in the laser field, there is a simple connection between the rotational wave-packet dynamics and the diffraction pattern obtained. Our theory thus opens up a new perspective for quantum molecular imaging using x-ray radiation.

99 GENERAL AND MISCELLANEOUS↗

Diffraction image formation in optical systems with polarization aberrations. I - Formulation and example

This paper is the first in a series that will examine image formation in optical systems with polarization aberrations. The present paper derives the point-spread function (PSF) and the optical transfer function for optical systems with polarization aberration and explores how image formation depends on the coherence and polarization state of the source. It is shown that the scalar PSF of Fourier optics can be generalized in the presence of polarization aberration to a 4 x 4 point-spread matrix (PSM) in Mueller matrix notation. A similar 4 x 4 optical transfer matrix (OTM) is shown to be an appropriate generalization of the optical transfer function. The PSM and the OTM are associated with the optical system and are independent of the incident polarization state but dependent on the coherence of the illumination. Since an optical system with polarization aberrations will have a different PSF and optical transfer function for different incident polarization states, the PSM and the OTM act as filters with regard to the incident polarization state. Example calculations are performed for a circularly retarding lens.

Mcguire, James P., Jr.↗

TH-AB-209-12: Tissue Equivalent Phantom with Excised Human Tissue for Assessing Clinical Capabilities of Coherent Scatter Imaging Applications

Purpose: Previously we reported the development of anthropomorphic tissue-equivalent scatter phantoms of the human breast. Here we present the first results from the scatter imaging of the tissue equivalent breast phantoms for breast cancer diagnosis. Methods: A breast phantom was designed to assess the capability of coded aperture coherent x-ray scatter imaging to classify different types of breast tissue (adipose, fibroglandular, tumor). The phantom geometry was obtained from a prone breast geometry scanned on a dedicated breast CT system. The phantom was 3D printed using the segmented DICOM breast CT data. The 3D breast phantom was filled with lard (as a surrogate for adipose tissue) and scanned in different geometries alongside excised human breast tissues (obtained from lumpectomy and mastectomy procedures). The raw data were reconstructed using a model-based reconstruction algorithm and yielded the location and form factor (i.e., momentum transfer (q) spectrum) of the materials that were imaged. The measured material form factors were then compared to the ground truth measurements acquired by x-ray diffraction (XRD) imaging. Results: Our scatter imaging system was able to define the location and composition of the various materials and tissues within the phantom. Cancerous breast tissue was detected and classified through automated spectral matching and an 86% correlation threshold. The total scan time for the sample was approximately 10 minutes and approaches workflow times for clinical use in intra-operative or other diagnostic tasks. Conclusion: This work demonstrates the first results from an anthropomorphic tissue equivalent scatter phantom to characterize a coherent scatter imaging system. The functionality of the system shows promise in applications such as intra-operative margin detection or virtual biopsy in the diagnosis of breast cancer. Future work includes using additional patient-derived tissues (e.g., human fat), and modeling additional organs (e.g., lung).

60 APPLIED LIFE SCIENCES↗

Invited article: X-ray phase contrast imaging in inertial confinement fusion and high energy density research

X-ray phase contrast imaging (XPCI) provides enhanced image contrast beyond absorption-based x-ray imaging alone due to refraction and diffraction from gradients in the object material density. It is sensitive to small variations in density, such as internal voids, cracks, grains, defects, and material flow, as well as to stronger density variations such as from a shock wave. Beyond its initial use in biology and materials science, XPCI is now routinely used in inertial confinement fusion (ICF) and high energy density (HED) research, first to characterize ICF capsules and targets, and later applied in dynamic experiments, where coherent x-ray sources, ultrafast x-ray pulses, and high temporal and spatial resolution are required. In this Review article, XPCI image formation theory is presented, its diverse use in ICF and HED research is discussed, the unique requirements for ultrafast XPCI imaging are given, as well as current challenges and issues in its use.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Size dependent strengthening mechanisms in sputtered Fe/W multilayers

We investigate size dependent strengthening mechanisms in sputtered Fe/W multilayers with individual layer thickness, h, varying from 1 to 200 nm. Microstructure analyses reveal that Fe/W has incoherent bcc/bcc interface when h is greater than 5 nm. When h decreases to 1-2.5 nm, the interface becomes semicoherent, and Fe and W show significant lattice distortions comparing to their bulk counterpart due to interface constraint. The layer thickness dependent drastic variations in x-ray diffraction profiles are simulated well by using an analytical model. Film hardness increases with decreasing h, and approaches a maximum value of 12.5 GPa when h is 1 nm. The layer thickness dependent film hardnesses are compared with analytical models. Koehler's image force plays a major role in determining the maximum strength of composites at smaller h.

36 MATERIALS SCIENCE↗

Phase retrieval and reconstruction of coherent synthesis by genetic algorithm

Abstract In the context of diffractive optics, phase retrieval is a heavily investigated process of recreating an entire complex electric field from partial amplitude-only information through iterative algorithms. However, existing methods can fall into local minima during reconstructions or struggle to recover unusual and novel electric field distributions. We present a numerical method based on a global-optimization genetic algorithm that reconstructs non-trivial electric field distributions from single diffracted intensity distributions. Diffraction and propagation of the optical fields over arbitrary distances is modeled through implementation of the angular spectrum technique. Additionally, a coherently-locked laser array system is used as an experimental case-study demonstrating 0.09 π phase reconstruction accuracy of initial laser parameters from single intensity images.

59 BASIC BIOLOGICAL SCIENCES↗

Relativistic Modeling of Ultra-Short Electron Pulse Propagation

The ultrafast electron microscopy, electron diffraction, electron crystallography, and nanocrystallography methods opened the possibility of studying the coherent structural dynamics of matter. The time resolution of the ultrafast electron microscopy and electron diffraction methods determined by the duration of electron pulses is the key parameter of experimental setups. This paper treats electron pulse dynamics in the field free drift region specifically for applications in atomic imaging. The electron beam is modeled as a system of particles (N) with N = 1000 and N = 10 000 electrons. The beam propagates for a certain period of time (1–4 ns); during its propagation, electron distribution parameters (over coordinates and velocities) are calculated to characterize the temporal profile and uncertainty in the electron wavelength at the sample. The results of applying relativistic dynamic equations show that nonrelativistic results are satisfactorily applicable (with 15 per cent or better accuracy) for modeling short electron pulse elongation and broadening at 30 keV and lower energies. However, the results of such modeling may be significantly in error for intermediate energies (300 keV), and for the fast relativistic beams (3 MeV) they become completely wrong. The relative reduction in Coulomb repulsion effects at higher energies is known, however; we give a comprehensive treatment that allows a quantitative picture. Using high-energy electron pulses results in almost complete elimination of the repulsive Coulomb effect. Dispersion of electron velocities becomes much lower at higher energies. For 3 MeV electrons, electron pulse duration as well as its radius does not noticeably change even after traveling for 4 ns (1.2 m). Even at 300 keV, the pulse duration increase is negligible until 1 ns (0.2 m). A simple mean-field model suggested in [13] has been extended to arbitrarily fast relativistic electron pulses with good correspondence to direct dynamic modeling.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Crystallization of niobium germanosilicate glasses

Niobium germanosilicate glasses are potential candidates for the fabrication of transparent glass ceramics with interesting non-linear optical properties. A series of glasses in the (Ge,Si)O{sub 2}-Nb{sub 2}O{sub 5}-K{sub 2}O system were prepared by melting and casting and their characteristic temperatures were determined by differential thermal analysis. Progressive replacement of GeO{sub 2} by SiO{sub 2} improved the thermal stability of the glasses. Depending on the composition and the crystallization heat-treatment, different nanocrystalline phases-KNbSi{sub 2}O{sub 7}, K{sub 3}Nb{sub 3}Si{sub 2}O{sub 13} and K{sub 3.8}Nb{sub 5}Ge{sub 3}O{sub 20.4} could be obtained. The identification and characterization of these phases were performed by X-ray diffraction and Raman spectroscopy. The 40 GeO{sub 2}-10 SiO{sub 2}-25 Nb{sub 2}O{sub 5}-25 K{sub 2}O (mol%) composition presented the higher ability for volume crystallization and its nucleation temperature was determined by the Marotta's method. An activation energy for crystal growth of {approx}529 kJ/mol and a nucleation rate of 9.7x10{sup 18} m{sup -3} s{sup -1} was obtained, for this composition. Transparent glass ceramics with a crystalline volume fraction of {approx}57% were obtained after a 2 h heat-treatment at the nucleation temperature, with crystallite sizes of {approx}20 nm as determined by transmission electron microscopy. - Abstract: TEM image and XRD pattern of the glass ceramic produced (circles indicate nanocrystals).

36 MATERIALS SCIENCE↗