Search NASA⌕ Search

SEARCH · Search NASA

Results for “Component sizing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Lipid droplet-associated proteins in alcohol-associated fatty liver disease: A proteomic approach

The earliest manifestation of alcohol-associated liver disease (ALD) is steatosis characterized by deposition of fat in specialized organelles called lipid droplets (LDs). While alcohol administration causes a rise in LD numbers in the hepatocytes, little is known regarding their characteristics that allow their accumulation and size to increase. The aim of the present study is to gain insights into underlying pathophysiological mechanisms by investigating the ethanol-induced changes in hepatic LD proteome as a function of LD size. Adult male Wistar rats (180–200 g BW) were fed with ethanol liquid diet for 6 weeks. At sacrifice, large-, medium-, and small-sized hepatic LD subpopulations (LD1, LD2, and LD3, respectively) were isolated and subjected to morphological and proteomic analyses. Morphological analysis of LD1-LD3 fractions of ethanol-fed rats clearly demonstrated that LD1 contained larger LDs compared with LD2 and LD3 fractions. Our preliminary results from principal component analysis showed that the proteome of different-sized hepatic LD fractions was distinctly different. Proteomic data analysis identified over 2000 proteins in each LD fraction with significant alterations in protein abundance among the three LD fractions. Among the altered proteins, several were related to fat metabolism, including synthesis, incorporation of fatty acid, and lipolysis. Ingenuity pathway analysis revealed increased fatty acid synthesis, fatty acid incorporation, LD fusion, and reduced lipolysis in LD1 compared to LD3. Overall, the proteomic findings indicate that the increased level of protein that facilitates fusion of LDs combined with an increased association of negative regulators of lipolysis dictates the generation of large-sized LDs during the development of alcohol-associated hepatic steatosis. Several significantly altered proteins were identified in different-sized LDs isolated from livers of ethanol-fed rats. Ethanol-induced increases in specific proteins that hinder LD lipid metabolism led to the accumulation and persistence of large-sized LDs in the liver.

60 APPLIED LIFE SCIENCES↗

Enhancing durability of polymer electrolyte membrane using cation size selective agents

Radical species generated during proton exchange membrane fuel cell operation considerably limit the achievable durability, particularly for heavy-duty vehicle applications. A promising solution to the problem is the incorporation of radical scavenger additives such as cerium which mitigates chemical attacks on the membrane. However, these additives migrate during fuel cell operation causing a loss in durability and performance due to detrimental interaction with various components of the fuel cell. Here, we study cation size selective agents as a means to immobilize cerium within perfluorosulfonic acid (PFSA) membranes. We synthesized an organometallic complex of cerium with 15-Crown-5 and investigated the effectiveness of this complex to immobilize cerium. Over 300% increase in cerium retention and an 80% increase in chemical durability were observed owing to the stabilization effect of crown ethers on cerium. Migration under a potential gradient can be eliminated while the complex also contributes to the enhancement in cerium radical scavenging activity. In conclusion, current challenges with the proposed solution are highlighted and future work is discussed.

25 ENERGY STORAGE↗

An Accurate Model of Beam Ion Instability with Nonlinear Space Charge, Realistic Beam Optics and Multiple Gas Species Vacuum

The previous analyses of beam ion instability have been performed for single gas species only. However, there are multiple gas species in the vacuum chambers of an accelerator. The superposition rule doesn’t apply in general and it overestimates the instability. Therefore, it is important to use multiple gas species model. On the other hand, the variation of beam size along the accelerator ring or linac provides Landau damping to the instability. In previous studies, the effect of beam optics has been represented by a frequency spread and a quality factor. In practice, it could be difficult to accurately estimate the frequency spread and quality factor for general beam optics because the variation of the beam size along the ring usually doesn’t have simple distribution. This paper provided a more accurate method to analyze beam ion instability with arbitrary vacuum component and arbitrary beam optics where the variation of the beam size along the accelerator ring or linac can be arbitrary. Meanwhile, the nonlinear space charge effect is also included and the general beam filling pattern can be easily modeled. Our analyses agree well with expensive simulations.

43 PARTICLE ACCELERATORS↗

Analyses of Diamond Wire Sawn Wafers: Effect of Various Cutting Parameters

We have evaluated surface characteristics of diamond wire cut (DWC) wafers sawn under a variety of cutting parameters. These characteristics include surface roughness, spatial frequencies of surface profiles, phase changes, damage depth, and lateral non-uniformities in the surface damage. Various cutting parameters investigated are: wire size, diamond grit size, reciprocating frequency, feed rate, and wire usage. Spatial frequency components of surface topography/roughness are influenced by individual cutting parameters as manifested by distinct peaks in the Fourier transforms of the Dektak profiles. The depth of damage is strongly controlled by diamond grit size and wire usage and to a smaller degree by the wire size.

14 SOLAR ENERGY↗

Ion Transport in Charged Membranes: Linking Electric-Field-Driven Mechanisms to Pore Size via Perturbation Analysis

Ion-exchange membranes are a critical component in electrochemical systems. Nevertheless, the understanding and modeling of ion transport within these porous structures have been limited by particular complexity reductions, either ignoring the dimensionality of their porous network architecture or imposing geometric assumptions (i.e., overlapping double layers). Before addressing this morphology-transport gap, a framework that relates the driving forces of transport to the geometry of a single pore is required. In this work, our modeling domain consists of a two-dimensional single pore with charged walls, connecting two identical electrolyte reservoirs. Using the Poisson-Nernst-Planck equations and regular perturbation theory, we decouple the electric fields and analyze the driving forces of ion transport, specifically electromigration and induced electroosmosis within the pore. These processes are described as analytical functions of the interaction aspect ratio, ?, defined as the ratio of the pore radius to the Debye length. Using this parameter, our study (i) describes the interplay between electromigrative and electroosmotic mechanisms that set ionic conductivity, (ii) identifies a dimensionless group of intrinsic electrolyte properties that indicates the predominant driving force, and (iii) provides a qualitative, confinement-dependent perspective on selectivity in ion-conducting membranes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermal Testing Quality Assurance of 24LCC & 3LCC Electronic Packages

The purpose of this project is to experimentally validate the thermal fatigue life of solder interconnects for a variety of surface mount electronic packages. Over the years, there has been a significant amount of research and analysis in the fracture of solder joints on printed circuit boards. Solder is important in the mechanical and electronic functionality of the component. It is important throughout the life of the product that the solder remains crack and fracture free. The specific type of solder used in this experiment is a 63Sn37Pb eutectic alloy. Each package was manufactured with conformal coating along with and without an underfill material below the device. Conformal coating helps protect the board from environments such as electrostatic discharge and humidity. It is commonly used in broad types of engineering disciplines such as commercial, military, research and development, etc. Conformal coating can also pose a risk for the life of the board because of its high thermal expansion coefficient. This can greatly decrease the life of the product if it regularly sees high temperature variations. This leads to a shorter fatigue life of the solder. The fatigue life is a common mechanical problem in the field of electronic devices. Adding underfill can help increase the fatigue life of the solder. However, applying underfill adds time to manufacturing and production. This ultimately increases the cost per unit. The study of conformal coated printed circuit boards with and without underfill was done on two different surface mount electronic packages. The electronic packages studied were 24 and 3 contact Leadless Ceramic Chips packages. When the package was not underfilled, the coating was allowed to flow underneath. The assembly was analyzed and tested to obtain the best available combination of conformal coating, underfill, and potting to design the most robust and reliable circuit board while keeping in mind certain factors such as cost, manufacturing time, and need. Different types of conformal coatings were considered with and without underfill for each device. 29 of each component were manufactured to have a large sample size and for the sake of individual defects and imperfections. Finite Element Analysis (FEA) was performed by an engineer at Sandia National Laboratories for both Leadless Ceramic Chips. From the FEA results, a test acceleration profile was derived and the number of temperature cycles to fail the solder interconnects were found for three different cases. Experimentation was done as a secondary measure to validate this data to show confidence in the theoretical analysis. Accelerated testing functions as a quality check for the product. Accelerated testing is extremely useful in the research and development phase of engineering. It can save money from the potential of early life defects and the costs that come along with warranties. Accelerated testing makes a weaker design more robust and checks the reliability of a strong design in a shorter period of time. It is extremely helpful in a world where deliverables are in high demand and scheduling is tight. Accelerated testing helps the engineer gain an understanding of what needs to be improved and what works well. There are many different types of accelerated tests. Our circuit boards were accelerated inside a closed thermal chamber because of the high number of use cycles. The ultimate goal of this experimentation is to help identify what will prevent any premature cracking or fracturing in the solder alloy. It is important to understand that underfilling each component may or may not be needed. If underfill is not needed, there are several production benefits.

42 ENGINEERING↗

Size-tunable silver nanoparticle synthesis in glycerol driven by a low-pressure nonthermal plasma

Silver nanoparticles (NPs) are extensively used in electronic components, chemical sensors, and disinfection applications, in which many of their properties depend on particle size. However, control over silver NP size and morphology still remains a challenge for many synthesis techniques. Here, in this work, we demonstrate the surfactant-free synthesis of silver NPs using a low-pressure inductively coupled nonthermal argon plasma. Continuously forming droplets of silver nitrate (AgNO 3 ) precursor dissolved in glycerol are exposed to the plasma, with the droplet residence time being determined by the precursor flow rate. Glycerol has rarely been studied in plasma-liquid interactions but shows favorable properties for controlled NP synthesis at low pressure. We show that the droplet residence time and plasma power have strong influence on NP properties, and that improved size control and particle monodispersity can be achieved by pulsed power operation. Silver NPs had mean diameters of 20 nm with geometric standard deviations of 1.6 under continuous wave operation, which decreased to 6 nm mean and 1.3 geometric standard deviation for pulsed power operation at 100 Hz and 20% duty cycle. We propose that solvated electrons from the plasma and vacuum ultraviolet (VUV) radiation induced electrons produced in glycerol are the main reducing agents of Ag + , the precursor for NPs, while no significant change of chemical composition of the glycerol solvent was detected.

36 MATERIALS SCIENCE↗

SU-E-J-06: Additional Imaging Guidance Dose to Patient Organs Resulting From X-Ray Tubes Used in CyberKnife Image Guidance System

Purpose: The use of image-guided radiation therapy (IGRT) has become increasingly common, but the additional radiation exposure resulting from repeated image guidance procedures raises concerns. Although there are many studies reporting imaging dose from different image guidance devices, imaging dose for the CyberKnife Robotic Radiosurgery System is not available. This study provides estimated organ doses resulting from image guidance procedures on the CyberKnife system. Methods: Commercially available Monte Carlo software, PCXMC, was used to calculate average organ doses resulting from x-ray tubes used in the CyberKnife system. There are seven imaging protocols with kVp ranging from 60 – 120 kV and 15 mAs for treatment sites in the Cranium, Head and Neck, Thorax, and Abdomen. The output of each image protocol was measured at treatment isocenter. For each site and protocol, Adult body sizes ranging from anorexic to extremely obese were simulated since organ dose depends on patient size. Doses for all organs within the imaging field-of-view of each site were calculated for a single image acquisition from both of the orthogonal x-ray tubes. Results: Average organ doses were <1.0 mGy for every treatment site and imaging protocol. For a given organ, dose increases as kV increases or body size decreases. Higher doses are typically reported for skeletal components, such as the skull, ribs, or clavicles, than for softtissue organs. Typical organ doses due to a single exposure are estimated as 0.23 mGy to the brain, 0.29 mGy to the heart, 0.08 mGy to the kidneys, etc., depending on the imaging protocol and site. Conclusion: The organ doses vary with treatment site, imaging protocol and patient size. Although the organ dose from a single image acquisition resulting from two orthogonal beams is generally insignificant, the sum of repeated image acquisitions (>100) could reach 10–20 cGy for a typical treatment fraction.

60 APPLIED LIFE SCIENCES↗

Ion-Photon Quantum Interface: Entanglement Engineering

Distributed quantum information processing requires a reliable quantum memory and a faithful carrier of quantum information. Trapped ion qubits are the leading realization for quantum information storage, and photonic qubits are the natural choice for the transport of quantum information. The capability to entangle photons with trapped ions in a highly efficient (scalable) fashion is an important achievement. Here, we leverage the active and successful development of micro-fabricated semiconductor ion traps at the Sandia National Laboratory MESA facility, and integrate micro optical components. Compared to current efforts in academic settings combining macro-sized ion traps and optics, a micro device will result in the dramatically increased speed and fidelity of ion-trap based quantum networking protocols. Integrating smaller components will directly allow for a stronger quantum coherent interface between a single trapped ion and a single photon. If successful, this technology could lead to new demonstrations of fundamental physics properties and would open new avenues for scalable quantum networking architectures.

Moehring, David Lynn↗

High-resolution Observations of the Massive Protostar in IRAS 18566+0408

We report 3 mm continuum, CH{sub 3}CN(5–4) and {sup 13}CS(2–1) line observations with CARMA (Combined Array for Research in Millimeter-wave Astronomy), in conjunction with 6 and 1.3 cm continuum VLA data, and 12 and 25 μm broadband data from the Subaru Telescope toward the massive proto-star IRAS 18566+0408. The VLA data resolve the ionized jet into four components aligned in the E–W direction. Radio components A, C, and D have flat centimeter SEDs indicative of optically thin emission from ionized gas, and component B has a spectral index α = 1.0, and a decreasing size with frequency ∝ν{sup −0.5}. Emission from the CARMA 3 mm continuum and from the {sup 13}CS(2–1) and CH{sub 3}CN(5–4) spectral lines is compact (i.e., <6700 au) and peaks near the position of the VLA centimeter source, component B. Analysis of these lines indicates hot and dense molecular gas, which is typical for HMCs. Our Subaru telescope observations detect a single compact source, coincident with radio component B, demonstrating that most of the energy in IRAS 18566+0408 originates from a region of size <2400 au. We also present UKIRT near-infrared archival data for IRAS 18566+0408, which show extended K-band emission along the jet direction. We detect an E–W velocity shift of about 10 km s{sup −1} over the HMC in the CH{sub 3}CN lines possibly tracing the interface of the ionized jet with the surrounding core gas. Our data demonstrate the presence of an ionized jet at the base of the molecular outflow and support the hypothesis that massive protostars with O-type luminosity form with a mechanism similar to lower mass stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Electrodynamic Calculation of Effective Electromagnetic Parameters of a Dielectric Medium with Metallic Nanoparticles of a Given Size

The frequency dependence of the effective complex permittivity and effective complex permeability of a heterostructure based on a dielectric medium containing metallic nanoparticles of spherical shape is calculated by an original method. In contrast to the Bruggeman [21] and the Maxwell Garnett [17] approaches, which use the quasi-static approximation in calculations, a nonuniform distribution of electromagnetic fields inside metallic particles is calculated, which allows the analysis of the electromagnetic parameters of the heterostructure not only as a function of frequency but also as a function of the nanoparticle size. It is shown that the plasmon resonant frequency decreases with increasing both the size and the concentration of particles in the heterostructure. It is also shown that a dielectric medium containing nonmagnetic metallic nanoparticles exhibits diamagnetic properties. In this case, the position of the maximum on the frequency dependence of the imaginary part of the magnetic susceptibility coincides with the relaxation frequency of charge carriers. The calculated spectra of the real and imaginary components of the permittivity of the heterostructure with a size of metallic particles less than 10 nm are in good agreement with Bruggeman calculations; however, the agreement with Maxwell Garnett calculations is observed only at nanoparticle concentrations lower than 10{sup –6}.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

U.S. Balance-of-Station Cost Drivers and Sensitivities (Presentation)

With balance-of-system (BOS) costs contributing up to 70% of the installed capital cost, it is fundamental to understanding the BOS costs for offshore wind projects as well as potential cost trends for larger offshore turbines. NREL developed a BOS model using project cost estimates developed by GL Garrad Hassan. Aspects of BOS covered include engineering and permitting, ports and staging, transportation and installation, vessels, foundations, and electrical. The data introduce new scaling relationships for each BOS component to estimate cost as a function of turbine parameters and size, project parameters and size, and soil type. Based on the new BOS model, an analysis to understand the non‐turbine costs has been conducted. This analysis establishes a more robust baseline cost estimate, identifies the largest cost components of offshore wind project BOS, and explores the sensitivity of the levelized cost of energy to permutations in each BOS cost element. This presentation shows results from the model that illustrates the potential impact of turbine size and project size on the cost of energy from U.S. offshore wind plants.

17 WIND ENERGY↗

Detector dose response in megavoltage small photon beams. II. Pencil beam perturbation effects

Purpose: To quantify detector perturbation effects in megavoltage small photon fields and support the theoretical explanation on the nature of quality correction factors in these conditions. Methods: In this second paper, a modern approach to radiation dosimetry is defined for any detector and applied to small photon fields. Fano’s theorem is adapted in the form of a cavity theory and applied in the context of nonstandard beams to express four main effects in the form of perturbation factors. The pencil-beam decomposition method is detailed and adapted to the calculation of perturbation factors and quality correction factors. The approach defines a perturbation function which, for a given field size or beam modulation, entirely determines these dosimetric factors. Monte Carlo calculations are performed in different cavity sizes for different detection materials, electron densities, and extracameral components. Results: Perturbation effects are detailed with calculated perturbation functions, showing the relative magnitude of the effects as well as the geometrical extent to which collimating or modulating the beam impacts the dosimetric factors. The existence of a perturbation zone around the detector cavity is demonstrated and the approach is discussed and linked to previous approaches in the literature to determine critical field sizes. Conclusions: Monte Carlo simulations are valuable to describe pencil beam perturbation effects and detail the nature of dosimetric factors in megavoltage small photon fields. In practice, it is shown that dosimetric factors could be avoided if the field size remains larger than the detector perturbation zone. However, given a detector and beam quality, a full account for the detector geometry is necessary to determine critical field sizes.

07 ISOTOPE AND RADIATION SOURCES↗

2019 Energy Storage Pricing Survey

Since grid energy storage is still evolving rapidly, it is often difficult to obtain project specific capital costs for various energy storage technologies. This information is necessary to evaluate the profitability of the facility, as well as comparing different energy storage technology options. The goal of this report is to summarize energy storage capital costs that were obtained from industry pricing surveys. The methodology breaks down the cost of an energy storage system into the following component categories: the storage module; the balance of system; the power conversion system; the energy management system; and the engineering, procurement, and construction costs. By evaluating each of the different component costs separately, a synthetic system cost can be developed that provides internal pricing consistency between different project sizes using the same technology, as well as between different technologies that utilize similar components.

25 ENERGY STORAGE↗

Biogeochemical fingerprinting of magnetotactic bacterial magnetite

Biominerals are important archives of the presence of life and environmental processes in the geological record. However, ascribing a clear biogenic nature to minerals with nanometer-sized dimensions has proven challenging. Identifying hallmark features of biologically controlled mineralization is particularly important for the case of magnetite crystals, resembling those produced by magnetotactic bacteria (MTB), which have been used as evidence of early prokaryotic life on Earth and in meteorites. In this work, we show that magnetite produced by MTB displays a clear coupled C–N signal that is absent in abiogenic and/or biomimetic (protein-mediated) nanometer-sized magnetite. We attribute the presence of this signal to intracrystalline organic components associated with proteins involved in magnetosome formation by MTB. These results demonstrate that we can assign a biogenic origin to nanometer-sized magnetite crystals, and potentially other biominerals of similar dimensions, using unique geochemical signatures directly measured at the nanoscale. This finding is significant for searching for the earliest presence of life in the Earth’s geological record and prokaryotic life on other planets.

58 GEOSCIENCES↗

Electrical Infrastructure Cost Model for Marine Energy Systems

The National Renewable Energy Laboratory's Electrical Infrastructure Cost Model is an Excel-based tool designed to estimate the electrical infrastructure costs of marine energy components and subsystems. It incorporates data collected from offshore wind projects, utility projects, and other relevant sources to provide accurate and comprehensive cost projections. With its user-friendly interface, the model allows users to input various parameters related to the system array, electrical cables, and substations. By leveraging industry data, cost trends, and technological advancements, the model generates outputs that include system array sizing, electrical cable specifications and costs, substation specifications and costs, and total electrical infrastructure costs. One of the notable strengths of the model is its flexibility in covering multiple-orders-of-magnitude scaled systems, accommodating projects ranging from proof-of-concept or pilot-scale installations to large-scale offshore systems. By collecting data largely from offshore wind reports and utility projects, the model incorporates real-world conditions and accounts for industry-specific factors. It incorporates cost trends and sizing relationships to deliver cost estimations for electrical infrastructure components, such as electrical cables and substation equipment.

16 TIDAL AND WAVE POWER↗

ON THE ROBUSTNESS OF z = 0-1 GALAXY SIZE MEASUREMENTS THROUGH MODEL AND NON-PARAMETRIC FITS

We present the size-stellar mass relations of nearby (z = 0.01-0.02) Sloan Digital Sky Survey galaxies, for samples selected by color, morphology, Sérsic index n, and specific star formation rate. Several commonly employed size measurement techniques are used, including single Sérsic fits, two-component Sérsic models, and a non-parametric method. Through simple simulations, we show that the non-parametric and two-component Sérsic methods provide the most robust effective radius measurements, while those based on single Sérsic profiles are often overestimates, especially for massive red/early-type galaxies. Using our robust sizes, we show for all sub-samples that the mass-size relations are shallow at low stellar masses and steepen above ∼3-4 × 10{sup 10} M{sub ☉}. The mass-size relations for galaxies classified as late-type, low-n, and star-forming are consistent with each other, while blue galaxies follow a somewhat steeper relation. The mass-size relations of early-type, high-n, red, and quiescent galaxies all agree with each other but are somewhat steeper at the high-mass end than previous results. To test potential systematics at high redshift, we artificially redshifted our sample (including surface brightness dimming and degraded resolution) to z = 1 and re-fit the galaxies using single Sérsic profiles. The sizes of these galaxies before and after redshifting are consistent and we conclude that systematic effects in sizes and the size-mass relation at z ∼ 1 are negligible. Interestingly, since the poorer physical resolution at high redshift washes out bright galaxy substructures, single Sérsic fitting appears to provide more reliable and unbiased effective radius measurements at high z than for nearby, well-resolved galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

Selective Permeability of Carbyne Membranes

The paper considers carbyne nanostructures as filtering members for separation of gas mixtures based on selective adsorption of its components, in particular, hydrogen, helium and methane. The size of a highlyselective cell is determined in this paper. It is found that the number of layers in carbyne membrane has no effect on the selective separation of gas mixtures.

36 MATERIALS SCIENCE↗