Search NASA⌕ Search

SEARCH · Search NASA

Results for “Count”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Radiation hard gallium oxide scintillators for high count rate radiation detection

Despite decades of materials research, the availability of appropriate crystalline radiation-hard scintillators with ultrafast decay times (~10ns) and high light yields (>2000 ph/MeV) are still limited. In this study, we demonstrate the potential of gallium oxide (β-Ga 2 O 3 ) based scintillators for high count rate applications. The low-cost rugged β-Ga 2 O 3 scintillators were grown using the optical float zone (FZ) technique. Several dopants and growth atmospheres were used to demonstrate the balance between ultrafast primary decay time and the light yield of the scintillators. Light yields as high as 6446 ± 716 ph/MeV were obtained with 18.3 ns decay time for 662 keV gamma rays. Decay times as fast as 12ns were obtained with a 3212 ± 357 ph/MeV light yield. An excellent 662 keV gamma energy resolution of 7% was obtained using the β-Ga 2 O 3 :Ce crystals. Even with these excellent scintillation properties, the gamma radiation hardness of β-Ga 2 O 3 crystals was better than the leading radiation-hard lead tungstate (PbWO 4 ) crystals. Twenty-six scintillators fabricated from the grown β-Ga 2 O 3 crystals were tested for radiation hardness with a 60 Co gamma irradiation rate of 14 krad/h with a total radiation dose of 2 Mrad. The scintillation properties of these crystals remained unaffected. To date, no other scintillator has demonstrated such high radiation resistance. Furthermore, these FZ-grown low-cost, non-hygroscopic, and high-density β-Ga 2 O 3 scintillators can replace the existing scintillators in many applications ranging from nuclear and high energy physics experiments to nuclear security.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Low Background Counting at LBNL

The Low Background Facility (LBF) at Lawrence Berkeley National Laboratory in Berkeley, California provides low background gamma spectroscopy services to a wide array of experiments and projects. The analysis of samples takes place within two unique facilities; locally within a carefully-constructed, low background cave and remotely at an underground location that historically has operated underground in Oroville, CA, but has recently been relocated to the Sanford Underground Research Facility (SURF) in Lead, SD. These facilities provide a variety of gamma spectroscopy services to low background experiments primarily in the form of passive material screening for primordial radioisotopes (U, Th, K) or common cosmogenic/anthropogenic products, as well as active screening via Neutron Activation Analysis for specific applications. The LBF also provides hosting services for general R&D testing in low background environments on the surface or underground for background testing of detector systems or similar prototyping. A general overview of the facilities, services, and sensitivities is presented. Recent activities and upgrades will also be presented, such as the completion of a 3π anticoincidence shield at the surface station and environmental monitoring of Fukushima fallout. The LBF is open to any users for counting services or collaboration on a wide variety of experiments and projects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Maternal exposure to a mixture of persistent organic pollutants (POPs) affects testis histology, epididymal sperm count and induces sperm DNA fragmentation in mice

Persistent organic pollutants (POPs) are widespread throughout the environment and some are suspected to induce reproductive toxicity. As animals and humans are exposed to complex mixtures of POPs, it is reasonable to assess how such mixtures could interact with the reproductive system. Our aim is to investigate how maternal exposure to a mixture of 29 different persistent organic pollutants, formulated to mimic the relative POP levels in the food basket of the Scandinavian population, could alter reproductive endpoints. Female mice were exposed via feed from weaning, during pregnancy and lactation in 3 exposure groups (control (C), low (L) and high (H)). Testicular morphometric endpoints, epididymal sperm concentration and sperm DNA integrity were assessed in adult male offspring. We found that the number of tubules, proportion of tubule compartments and epididymal sperm concentration significantly decreased in both POP exposed groups. Epididymal sperm from both POP exposed groups showed increased DNA fragmentation. It is concluded that maternal exposure to a defined POP mixture relevant to human exposure can affect testicular development, sperm production and sperm chromatin integrity. - Highlights: • Male mice were maternally exposed to a mixture of persistent organic pollutants. • Exposure significantly affected the testis histology. • Exposure significantly decreased sperm count and induced sperm DNA fragmentation. • Maternal exposure to POP mixture induced reproductive toxicity in male offspring.

60 APPLIED LIFE SCIENCES↗

Ordered BaAl4- Type Variants in the BaAuxSn4-x System: A Unified View on Their Phase Stabilities versus Valence Electron Counts

Three ordered structures of the tetragonal BaAl4 type were identified in the Ba–Au–Sn system, from which a unified view of the interplay between the valence electron counts (VECs) and phase stabilities of these three types of derivatives can be developed. The BaNiSn3 (I4mm), ThCr2Si2 (I4/mmm), and CaBe2Ge2 (P4/nmm) type BaAuxSn4–x phases occurred respectively at x = 0.78(1)–1, 1.38(1)–1.47(1), and 1.52(1)–2.17(1), consistent with theoretical atomic “coloring” analyses that reveal an optimal VEC of 14 for the ThCr2Si2 type but larger and smaller values respectively for the BaNiSn3- and CaBe2Ge2-type structures.

36 MATERIALS SCIENCE↗

Increases in Future AR Count and Size: Overview of the ARTMIP Tier 2 CMIP5/6 Experiment

Abstract The Atmospheric River (AR) Tracking Method Intercomparison Project (ARTMIP) is a community effort to systematically assess how the uncertainties from AR detectors (ARDTs) impact our scientific understanding of ARs. This study describes the ARTMIP Tier 2 experimental design and initial results using the Coupled Model Intercomparison Project (CMIP) Phases 5 and 6 multi‐model ensembles. We show that AR statistics from a given ARDT in CMIP5/6 historical simulations compare remarkably well with the MERRA‐2 reanalysis. In CMIP5/6 future simulations, most ARDTs project a global increase in AR frequency, counts, and sizes, especially along the western coastlines of the Pacific and Atlantic oceans. We find that the choice of ARDT is the dominant contributor to the uncertainty in projected AR frequency when compared with model choice. These results imply that new projects investigating future changes in ARs should explicitly consider ARDT uncertainty as a core part of the experimental design.

54 ENVIRONMENTAL SCIENCES↗

Counting generations in birth and death processes with competing Erlang and exponential waiting times

Lymphocyte populations, stimulated in vitro or in vivo, grow as cells divide. Stochastic models are appropriate because some cells undergo multiple rounds of division, some die, and others of the same type in the same conditions do not divide at all. If individual cells behave independently, then each cell can be imagined as sampling from a probability density of times to division and death. The exponential density is the most mathematically and computationally convenient choice. It has the advantage of satisfying the memoryless property, consistent with a Markov process, but it overestimates the probability of short division times. With the aim of preserving the advantages of a Markovian framework while improving the representation of experimentally-observed division times, we consider a multi-stage model of cellular division and death. We use Erlang-distributed (or, more generally, phase-type distributed) times to division, and exponentially distributed times to death. We classify cells into generations, using the rule that the daughters of cells in generation n are in generation n + 1. In some circumstances, our representation is equivalent to established models of lymphocyte dynamics. We find the growth rate of the cell population by calculating the proportions of cells by stage and generation. The exponent describing the late-time cell population growth, and the criterion for extinction of the population, differs from what would be expected if N steps with rate λ were equivalent to a single step of rate λ/N. We link with a published experimental dataset, where cell counts were reported after T cells were transferred to lymphopenic mice, using Approximate Bayesian Computation. In the comparison, the death rate is assumed to be proportional to the generation and the Erlang time to division for generation 0 is allowed to differ from that of subsequent generations. The multi-stage representation is preferred to a simple exponential in posterior distributions, and the mean time to first division is estimated to be longer than the mean time to subsequent divisions.

59 BASIC BIOLOGICAL SCIENCES↗

Planck 2013 results. XX. Cosmology from Sunyaev–Zeldovich cluster counts

We present constraints on cosmological parameters using number counts as a function of redshift for a sub-sample of 189 galaxy clusters from the Planck SZ (PSZ) catalogue. The PSZ is selected through the signature of the Sunyaev-Zeldovich (SZ) effect, and the sub-sample used here has a signal-to-noise threshold of seven, with each object confirmed as a cluster and all but one with a redshift estimate. We discuss the completeness of the sample and our construction of a likelihood analysis. Using a relation between mass M and SZ signal Y calibrated to X-ray measurements, we derive constraints on the power spectrum amplitude σ8 and matter density parameter Ω m in a flat ΛCDM model. We test the robustness of our estimates and find that possible biases in the Y–M relation and the halo mass function are larger than the statistical uncertainties from the cluster sample. Assuming the X-ray determined mass to be biased low relative to the true mass by between zero and 30%, motivated by comparison of the observed mass scaling relations to those from a set of numerical simulations, we find that σ 8 = 0.75 ± 0.03, Ω m = 0.29 ± 0.02, and σ 8 (Ω m /0.27) 0.3 = 0.764 ± 0.025. The value of σ 8 is degenerate with the mass bias; if the latter is fixed to a value of 20% (the central value from numerical simulations) we find σ 8 (Ω m /0.27) 0.3 = 0.78 ± 0.01 and a tighter one-dimensional range σ 8 = 0.77 ± 0.02. We find that the larger values of σ 8 and Ω m preferred by Planck's measurements of the primary CMB anisotropies can be accommodated by a mass bias of about 40%. Alternatively, consistency with the primary CMB constraints can be achieved by inclusion of processes that suppress power on small scales relative to the ΛCDM model, such as a component of massive neutrinos. We place our results in the context of other determinations of cosmological parameters, and discuss issues that need to be resolved in order to make further progress in this field.

79 ASTRONOMY AND ASTROPHYSICS↗

Counter Architectures for a Single Photon-Counting Pixel Detector such as Medipix3

Medipix3 is a single photon-counting pixel readout chip whose new front-end architecture aims to eliminate the spectral distortion produced by charge diffusion in highly segmented semiconductor detectors. The chip requires area and power-efficient reconfigurable digital counters and shift registers that can be integrated with other photon-processing analog and digital circuits within the 55 {mu}mx55 {mu}m pixel area. This work proposes a configurable-depth, programmable mode digital counter for use in Medipix3.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration and Characterization of Single Photon Counting Cameras for Short-Pulse Laser Experiments

The photon counting efficiency of various CCD based cameras was studied as a function of x-ray energy and exposure. A pair of Spectral Instruments Model 800 CCD cameras fitted with 16 {micro}m thick back-illuminated CCDs were calibrated at low x-ray energy using two well established histogram methods, a standard pixel for pixel histogram and the single pixel event histogram method. In addition, two new thick substrate CCDs were evaluated for use at high energy. One was a commercially available Princeton Instruments LCX1300 deep depletion CCD camera while the other was a custom designed 650 {micro}m thick partially depleted CCD fitted to a SI 800 camera body. It is shown that at high x-ray energy, only a pixel-summing algorithm was able to derive spectral data due to the spreading of x-ray events over many pixels in the thicker substrate CCDs. This paper will describe the different algorithms used to extract spectra and the absolute detection efficiencies using these algorithms. These detectors will be very useful to detect high-energy x-ray photons from high-intensity short pulse laser interactions.

42 ENGINEERING↗

Asymptotic counting of BPS operators in superconformal field theories

We consider some aspects of counting BPS operators which are annihilated by two supercharges in superconformal field theories. For nonzero coupling, the corresponding multivariable partition functions can be written in terms of generating functions for vector partitions or their weighted generalizations. We derive asymptotics for the density of states for a wide class of such multivariable partition functions. We also point out a particular factorization property of the finite N partition functions. Finally, we discuss the concept of a limit curve arising from the large N partition functions, which is related to the notion of a 'typical state', and discuss some implications for the holographic dua0008.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An active drop counting device using condenser microphone for superheated emulsion detector

An active device for superheated emulsion detector is described. A capacitive diaphragm sensor or condenser microphone is used to convert the acoustic pulse of drop nucleation to electrical signal. An active peak detector is included in the circuit to avoid multiple triggering of the counter. The counts are finally recorded by a microprocessor based data acquisition system. Genuine triggers, missed by the sensor, were studied using a simulated clock pulse. The neutron energy spectrum of {sup 252}Cf fission neutron source was measured using the device with R114 as the sensitive liquid and compared with the calculated fission neutron energy spectrum of {sup 252}Cf. Frequency analysis of the detected signals was also carried out.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectral Performance of Photon Counting Pixel Detector Using Attenuation Spectra for Test Samples

When a material is placed along the path of an X-ray beam using a broad range of energy X-ray source, the energy dependence of the attenuation for the X-ray photons will be substantially dissimilar for different materials. The process at which X-ray radiation loses its penetrating strength as it travels through a material will be significantly larger for photons with energy above k-edge energy of that material than for those with slightly lower energy. Hence energy resolved X-ray imaging can be used to achieve colour images revealing the material content of the test sample. The attenuation of the spectrum done by scanning an energy window through the spectrum was measured for a number of samples of different materials. The test samples include Sn, Gd and I with K-edge energy at 29 keV, 50 keV and 33 keV, respectively, using a Feinfocus microfocus X-ray source (FTP-105.02) with Medipix2 photon counting chip.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bogomolny-Prasad-Sommerfeld state counting in local obstructed curves from quiver theory and Seiberg duality

In this paper, we study the Bogomolny-Prasad-Sommerfeld (BPS) state counting in the geometry of local obstructed curve with normal bundle O+O(-2). We find that the BPS states have a framed quiver description. Using this quiver description along with the Seiberg duality and the localization techniques, we can compute the BPS state indices in different chambers dictated by stability parameter assignments. This provides a well-defined method to compute the generalized Donaldson-Thomas invariants. This method can be generalized to other affine ADE quiver theories.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low Background Counting At SNOLAB

It is a continuous and ongoing effort to maintain radioactivity in materials and in the environment surrounding most underground experiments at very low levels. These low levels are required so that experiments can achieve the required detection sensitivities for the detection of low-energy neutrinos, searches for dark matter and neutrinoless double-beta decay. SNOLAB has several facilities which are used to determine these low background levels in the materials and the underground environment. This proceedings will describe the SNOLAB High Purity Germanium Detector which has been in continuous use for the past five years and give results of many of the items that have been counted over that period. Brief descriptions of SNOLAB's alpha-beta and electrostatic counters will be given, and the radon levels at SNOLAB will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Chiral Effective Field Theory Beyond the Power-Counting Regime

Novel techniques are presented, which identify the chiral power-counting regime (PCR), and realize the existence of an intrinsic energy scale embedded in lattice QCD results that extend outside the PCR. The nucleon mass is considered as a benchmark for illustrating this new approach. Using finite-range regularization, an optimal regularization scale can be extracted from lattice simulation results by analyzing the renormalization of the low energy coefficients. The optimal scale allows a description of lattice simulation results that extend beyond the PCR by quantifying and thus handling any scheme-dependence. Preliminary results for the nucleon magnetic moment are also examined, and a consistent optimal regularization scale is obtained. This indicates the existence of an intrinsic scale corresponding to the finite size of the source of the pion cloud.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The coincidence counting technique for orders of magnitude background reduction in data obtained with the magnetic recoil spectrometer at OMEGA and the NIF

A magnetic recoil spectrometer (MRS) has been built and successfully used at OMEGA for measurements of down-scattered neutrons (DS-n), from which an areal density in both warm-capsule and cryogenic-DT implosions have been inferred. Another MRS is currently being commissioned on the National Ignition Facility (NIF) for diagnosing low-yield tritium-hydrogen-deuterium implosions and high-yield DT implosions. As CR-39 detectors are used in the MRS, the principal sources of background are neutron-induced tracks and intrinsic tracks (defects in the CR-39). The coincidence counting technique was developed to reduce these types of background tracks to the required level for the DS-n measurements at OMEGA and the NIF. Using this technique, it has been demonstrated that the number of background tracks is reduced by a couple of orders of magnitude, which exceeds the requirement for the DS-n measurements at both facilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗