Search NASA⌕ Search

SEARCH · Search NASA

Results for “DAMPER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Analysis of a Radioactive Release in a Nuclear Waste Disposal Facility

The Waste Isolation Pilot Plant (WIPP) is a 655-meter deep mine near Carlsbad, New Mexico, used to dispose the nation’s defense transuranic waste. Limited airborne radioactivity was released from a container of radioactive waste in WIPP on 14 February, 2014. As designed, a mine ventilation filtration system prevented the large scale release of contamination from the underground. However, isolation dampers leaked, which allowed the release of low levels of contaminants after the event until they were sealed. None of the exposed individuals received any recordable dose. While surface contamination was limited, contamination in the ventilation system and portions of the underground was substantial. High efficiency particulate air (HEPA) filters in the operating ventilation system ensure continued containment during recovery and resumption of disposal operations. However, ventilation flow is restricted since the incident, with all exhaust air directed through the filters. Decontamination and natural fixation by the hygroscopic nature of the salt host rock has reduced the likelihood of further contamination spread. Contamination control and ventilation system operability are crucial for resumption of operations. This article provides an operational assessment and evaluation of these two key areas.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High Specific Stiffness Shafts and Advanced Bearing Coatings for Gas Turbine Engines Final Report CRADA No. TC-1089-95

At the time of the CRADA, the largest in-service gas-turbine aircraft engines strove for increased thrust and power density to meet the requirements for take-off thrust, given the increase in take-off gross weight (TOGW) associated with longer range transport requirements. The trend in modem turbo shaft engines was toward turbine shafts with higher and higher length-to-diameter ratios, which reduced the shaft critical speed. Using co nventional shaft materials, this lead to shafts that needed to operate near or above sensitive shaft bending critical speeds, therefore requiring multiple bearings and/ or multiple squeeze-film dampers to control the dynamic response. Using new materials and d esign concepts this project demonstrated the use of new shaft materials which could provide increased shaft speed range above existing maximum engine speeds without encountering a critic al speed event and high vector deflections. This increased main shaft speed also resulted in decreased bearing life associated with lower heat dissipation and higher centrifugal forces. Thus, a limited effort was devoted to feasibility of higher performance bearing coatings to mitigate the speed effects.

42 ENGINEERING↗

User-Oriented Modeling Tools for Advanced Hybrid and Climate-Appropriate Rooftop Air Conditioners

Hybrid unitary air conditioning systems offer a pathway to substantially reduce energy use and peak electrical demand for cooling, heating, and ventilation in commercial buildings. Hybrid air conditioners incorporate multiple subsystems that are carefully orchestrated to provide climate- and application-specific efficiency advantages. There are a multitude of hybrid system architectures, but common subsystems include: heat recovery ventilation, indirect evaporative cooling, desiccant dehumidification, variable speed fans, modulating dampers, and multi-stage or variable-speed vapor compression cooling. Categorically, hybrid systems can operate in numerous discrete modes. For example: indirect evaporative cooling may operate for periods when the subsystem provides adequate sensible cooling, then vapor compression cooling will be included when more cooling or dehumidification is necessary. Laboratory assessments, field studies, and simulations have demonstrated that hybrid unitary air conditioners could reduce energy use for cooling and ventilation by 30-90% depending on climate and application. Heretofore, it has been challenging - if not impossible - for practitioners to model hybrid air conditioners as part of building energy simulations; and the limitation has severely obstructed broader adoption of technologies in this class. In this project, we developed a new feature for EnergyPlus that enables modeling hybrid unitary air conditioning equipment for building energy simulations. This is a significant advancement for both theory and practice, and confers public benefit by enabling practitioners to evaluate this compelling efficiency technology as a part of building energy simulations. The feature is a black-box model that requires extensive performance data for each hybrid unitary product. In parallel, we also developed new features for the Technology Performance Exchange to enable manufacturers to submit performance data in a standard format that can be used with the hybrid unitary model in EnergyPlus. Additionally, through this project we expanded university educational resources, and university- manufacturing industry collaborations in the field of energy efficiency technology. Over two years, we involved 20 undergraduate students in ambitious research projects focused on modeling complex multi-mode mechanical systems, supported three mechanical engineering bachelor theses, established undergraduate apprenticeships with multiple industry partners, and involved those partners in the process of design, validation, and debugging for the new EnergyPlus feature. The EnergyPlus feature is described and discussed in an academic article, as well as in an engineering reference, and input/output reference documentation for EnergyPlus. The Technology Performance Exchange features are live and publicly accessible, our manufacturer partners are primed to submit initial product information and performance data to the exchange, and the EnergyPlus feature is scheduled for public release in Spring 2018 as a part of EnergyPlus v8.9.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Landau Damping with Electron Lenses in Space-Charge Dominated Beams

Progress on the Intensity Frontier of high energy physics critically depends on record high intensity charged particles accelerators. Beams in such machines become operationally limited by coherent beam instabilities, particularly enhanced in the regime of strong space charge (SC). Usual methods to control the instabilities, such as octupole magnets, beam feedback dampers and employment of chromatic effects, become less effective and insufficient. In [1] it was proposed to employ electron lenses for introduction of sufficient spread in particle oscillation frequencies needed for beam stabilization and in [2] it was shown that electron lenses are uniquely effective for Landau damping of transverse beam instabilities in high energy particle accelerators and their employment does not compromise incoherent (single particle) stability, dynamic aperture and the beam lifetime. Here we consider an important issue of effectiveness of the Landau damping with electron lenses in space-charge dominated beams and demonstrate that the desired stability can be assured with proper choice of the electron beam parameters and current distributions.

43 PARTICLE ACCELERATORS↗

Vertical Coupled Bunched-Beam Breakup Due to Resistive-Wall Wake

We estimate in this note the magnitude of the vertical rigid coupled-bunch mode of Courant and Sessler [1] at NSLS-II. If the proposed mini gap undulators (MGUs) are operated at the room temperature, the threshold current is calculated to be about 10 mA; this is to be compared to the designed beam current of 500 mA. If the MGUs are operated at 4.2 Kelvins, the threshold current is about 120 mA. In either case, a feedback damper is needed in order to operate NSLS-II at 500 mA.

43 PARTICLE ACCELERATORS↗

Compressible degree of freedom (CDOF): A potential strategy for improving wave energy capture

The addition of a compressible degree of freedom (CDOF) has been shown to significantly increase the power absorption compared to a traditional rigid WEC of the same shape and mass for a variety of architectures. The present study demonstrates that a compressible point absorber, with a passive power-take-off (PTO) and optimized damping, can also achieve at the same performance levels or better than an optimally controlled rigid point absorber using reactive power from the PTO. Eliminating the need for a reactive PTO would substantially reduce costs by reducing PTO design complexity. In addition, it would negate the documented problems of reactive PTO efficiencies on absorbed power. Improvements to performance were quantified in the present study by comparing a compressible point absorber to a conventional rigid one with the same shape and mass. Wave energy is converted to mechanical energy in both cases using a linear damper PTO, with the PTO coefficient optimized for each resonance frequency and compressible volume. The large compressible volumes required to tune the compressible point absorber to the desired frequency are a practical limitation that needs to be addressed with further research; especially for low frequencies. If fact, all compressible volumes exceed the submerged volume of the point absorber by significant amounts; requiring auxiliary compressible volume storage units that are connected to the air chamber in the submerged portion of the point absorber. While realistic, these auxiliary units would increase the Cap Ex and Op Ex costs, potentially reducing the aforementioned benefits gained by CDOF. However, alternative approaches can be developed to implement CDOF without the large compressible volume requirements, including the development of flexible surface panels tuned with mechanical springs.

42 ENGINEERING↗

Vertical Coupled Bunched-Beam Breakup Due to Resistive-Wall Wake

We estimate in this note the magnitude of the vertical rigid coupled-bunch mode of Courant and Sessler at NSLS-II. If the proposed mini gap undulators (MGUs) are operated at the room temperature, the threshold current is calculated to be about 10 mA; this is to be compared to the designed beam current of 500 mA. If the MGUs are operated at 4.2° Kelvins, the threshold current is about 120 mA. In either case, a feedback damper is needed in order to operate NSLS-II at 500 mA.

36 MATERIALS SCIENCE↗

Waveguide HOM Loads for High Current Elliptical Cavities

Waveguide HOM dampers are widely used in high current RF cavities, as waveguides are natural high pass RF filters and can easily handle high RF power. In this presentation, the author will review a few typical waveguide HOM load designs, especially the recently developed high power HOM loads for bERLinpro and BESSY-VSR. We will report the RF-thermal-mechanical design, fabrication technology, absorber material choice, as well as the testing results of these HOM loads.

Guo, Jiquan↗

BESSY VSR and bERLinpro HOM loads development

Two accelerator projects at Helmholtz-Zentrum Berlin (HZB), bERLinPro and BESSY-VSR (Variable pulse length Storage Ring) upgrade, need to design three variants of SRF cavities, 1.3GHz cavities for bERLinPro and 1.5GHz/1.75GHz cavities for BESSY-VSR. These cavities have adopted waveguide HOM dampers in their design, with a few tens of watts HOM power in each load for bERLinPro cavities and a few hundred watts for BESSY-VSR cavities. Jlab is collaborating with HZB designing and prototyping HOM loads for these cavities. In this presentation, we will report on the integrated RF-thermal-mechanical design as well as the latest fabrication and testing results of these loads.

Guo, Jiquan↗

Building ControlScore: General Service Administration Office Building Deployment

Improvements to building control systems can lead to energy savings and increased occupant comfort. In an optimized system, process variables such as air temperature will closely follow their desired setpoints and avoid excess energy use. Typically, experts must manually inspect individual control loops to identify poor performance and opportunities for improvement. However, this approach is difficult in modern buildings that have a prohibitively large number of controllers. To address this issue, Pacific Northwest National Laboratory (PNNL) created the ControlScore concept, which takes operating data from the many controllers within a building and generates standardized scores for each loop on a scale of 0 to 10 (a score of 0 indicates poor control, a score of 10 indicates good control). PNNL applied the Building ControlScore application to all available data from a General Services Administration office building within the period of January 1, 2023, to March 9, 2023. The building scored a 4.7 overall, with all 74 of the building’s loops fitting a roughly normal distribution centered around 5. These results indicate that the analyzed systems have below-average performance with room for improvement, especially in the poorly scored systems. Airflow loops tended to have much lower scores than zone temperature loops. The lowest and highest performing systems in the building section were identified, as were all loops with a score less than 1. While the ControlScore identifies loops and systems that aren’t meeting their designated setpoints, it does not indicate the cause of those issues. For example, consider a supply air terminal unit’s airflow loop that received a low score due to it delivering less air than specified by the setpoint. The lower-than-desired airflow could be due to equipment limitations (e.g., the terminal unit or duct serving is too small to accommodate that airflow), malfunctioning equipment (e.g., a stuck damper or bad sensor), or something else entirely. The ControlScore does not diagnose problems it simply identifies the symptoms that can be explored and addressed by building operators.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Toxic consequences of a sodium fire in a FFTF dump heat exchanger (Initial release 02-11-2000)

A calculation of sodium aerosol concentrations at the site boundary. This would result from a worse case DHX module tube leak with the reactor operating, DHX fans running, and module dampers open. Resulting site boundary concentrations are less than the risk guidelines for an extremely unlikely event. This will be used in an upcoming revision of the FFTF FSAR and FHA Sodium Fire Analyses.

DHX↗

Development of an Integrated Residential Heating, Ventilation, Cooling, and Dehumidification System for Residences

The Need and the Opportunity Codes such as ASHRAE 90.2 and IECC, and programs such as Energy Star and Builders Challenge, are causing new homes to be built to higher performance standards. As a result sensible cooling loads in new homes are going down, but indoor air quality prerogatives are causing ventilation rates and moisture loads to increase in humid climates. Conventional air conditioners are unable to provide the low sensible heat ratios that are needed to efficiently cool and dehumidify homes since dehumidification potential is strongly correlated with cooling system operating hours. The project team saw an opportunity to develop a system that is at least as effective as a conventional air conditioner plus dehumidifier, removes moisture without increasing the sensible load, reduces equipment cost by integrating components, and simplifies installation. Project Overview Prime contractor Davis Energy Group led a team in developing an Integrated Heating, Ventilation, Cooling, and Dehumidification (I-HVCD) system under the DOE SBIR program. Phase I and II SBIR project activities ran from July 2003 through December 2007. Tasks included: (1) Mechanical Design and Prototyping; (2) Controls Development; (3) Laboratory and Field Testing; and (4) Commercialization Activities Technology Description. Key components of the prototype I-HVCD system include an evaporator coil assembly, return and outdoor air damper, and controls. These are used in conjunction with conventional components that include a variable speed air handler or furnace, and a two-stage condensing unit. I-HVCD controls enable the system to operate in three distinct cooling modes to respond to indoor temperature and relative humidity (RH) levels. When sensible cooling loads are high, the system operates similar to a conventional system but varies supply airflow in response to indoor RH. In the second mode airflow is further reduced, and the reheat coil adds heat to the supply air. In the third mode, the reheat coil adds additional heat to maintain the supply air temperature close to the return air temperature (100% latent cooling). Project Outcomes Key Phase II objectives were to develop a pre-production version of the system and to demonstrate its performance in an actual house. The system was first tested in the laboratory and subsequently underwent field-testing at a new house in Gainesville, Florida. Field testing began in 2006 with monitoring of a 'conventional best practices' system that included a two stage air conditioner and Energy Star dehumidifier. In September 2007, the I-HVCD components were installed for testing. Both systems maintained uniform indoor temperatures, but indoor RH control was considerably better with the I-HVCD system. The daily variation from average indoor humidity conditions was less than 2% for the I-HVCD vs. 5-7% for the base case system. Data showed that the energy use of the two systems was comparable. Preliminary installed cost estimates suggest that production costs for the current I-HVCD integrated design would likely be lower than for competing systems that include a high efficiency air conditioner, dehumidifier, and fresh air ventilation system. Project Benefits This project verified that the I-HVCD refrigeration compacts are compact (for easy installation and retrofit) and can be installed with air conditioning equipment from a variety of manufacturers. Project results confirmed that the system can provide precise indoor temperature and RH control under a variety of climate conditions. The I-HVCD integrated approach offers numerous benefits including integrated control, easier installation, and reduced equipment maintenance needs. Work completed under this project represents a significant step towards product commercialization. Improved indoor RH control and fresh air ventilation are system attributes that will become increasingly important in the years ahead as building envelopes improve and sensible cooling loads continue to fall. Technologies like I-HVCD will be instrumental in meeting goals set by Building America and other programs to reduce energy use while improving the indoor environment. Next Steps The following steps are needed to bring the product to commercialization: (1) Value engineering to reduce costs; (2) Addition of zoning capability to improve marketability; (3) Fabrication and testing of additional prototypes; and (4) Identification of a manufacturer. Initial efforts to interest large air conditioner manufacturers has shown some interest, but the preferred path to market may be to employ a boutique manufacturer that markets to HVAC contractors. Distribution of the results of this work will improve opportunities for attracting manufacturers. Additional funding is needed to prepare the product for this final step.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ferrite HOM Absorber for the RHIC ERL

A superconducting Energy Recovery Linac is under construction at Brookhaven National Laboratory to serve as test bed for RHIC upgrades. The damping of higher-order modes in the superconducting five-cell cavity for the Energy-Recovery linac at RHIC is performed exclusively by two ferrite absorbers. The ferrite properties have been measured in ferrite-loaded pill box cavities resulting in the permeability values given by a first-order Debye model for the tiled absorber structure and an equivalent permeability value for computer simulations with solid ring dampers. Measured and simulated results for the higher-order modes in the prototype copper cavity are discussed. First room-temperature measurements of the finished niobium cavity are presented which confirm the effective damping of higher-order modes in the ERL. by the ferrite absorbers.

43 PARTICLE ACCELERATORS↗

Measurement of HOMs in the RHIC RF Cavities

The authors present results of Higher Order Modes (HOMs) measurements in the RHIC accelerating (28 MHz system) and storage (197 MHz system) cavities. The power of the excited HOMs deposited into the HOM damper is measured and compared with an analytical calculation of the HOMs power. The quality factors (Q) are also measured and compared to previous measurements.

43 PARTICLE ACCELERATORS↗

Self-Correcting HVAC Controls Project Final Report

This document represents the final project report for the Self-Correcting Heating, Ventilating and Air-Conditioning (HVAC) Controls Project jointly funded by Bonneville Power Administration (BPA) and the U.S. Department of Energy (DOE) Building Technologies Program (BTP). The project, initiated in October 2008, focused on exploratory initial development of self-correcting controls for selected HVAC components in air handlers. This report, along with the companion report documenting the algorithms developed, Self-Correcting HVAC Controls: Algorithms for Sensors and Dampers in Air-Handling Units (Fernandez et al. 2009), document the work performed and results of this project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence Q - Raw Data

Sequence Q: Dynamic Inflow (P) This sequence was designed to characterize the dynamic inflow variation using the five-hole probes that extend upwind of the leading edge of the blade. This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speeds ranged from 5 m/s to 15 m/s, and data were collected at a 0° yaw angle. The rotor rotated at 72 RPM. Blade and probe pressure measurements were collected. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to -99999.99 Nm. The teeter link load cell was pretensioned to 40,000 N. The blade pitch angle was changed from the initial tip pitch angle to the final tip pitch angle at the maximum rate of 67°/s. This angle was maintained for the specified delay time duration. Then the blade was pitched back to the initial pitch angle and held for the specified hold time. This was repeated 20 times. The campaign at 15 m/s was aborted early due to excessive low-speed shaft torque loads. The file length varied depending on the time required to obtain 20 pitch cycles for the specified range of angles. The name convention was the standard format, except for the short campaigns collected to ascertain the functionality of the instrumentation. These points were collected at a 3° pitch angle and use the characters REF in the four digits that normally represent yaw angle.

17 WIND ENERGY↗

UAE6 - Wind Tunnel Tests Data - UAE6 - Sequence W - Raw Data

Sequence W: Extended Blade (F) This test sequence used an upwind, rigid turbine with a 0° cone angle. The wind speed ranged from 5 m/s to 21 m/s, and the yaw angle was held at 0°. The blade pitch angle was 3°. The rotor rotated at 72 RPM. Blade pressure measurements were collected. The five-hole probes were removed and the plugs were installed. Plastic tape 0.03-mm thick was used to smooth the interface between the plugs and the blade. The teeter dampers were replaced with rigid links, and these two channels were flagged as not applicable by setting the measured values in the data file to –99999.99 Nm. The teeter link load cell was pretensioned to 40,000 N. During postprocessing, the probe channels were set to read –99999.99. The standard tip blocks were replaced with blade extensions that created a 5.532-m radius rotor as shown in Appendix A. The extension used the S809 airfoil throughout, and the linear taper of the blade continued along the extension. Note that the blade radius was not changed during post-processing so the pressure tap locations are at the same radial location, but the reference to 30% represents 30% of 5.029 m, not 5.532 m. Throughout this report, references to the blade span are made for the 5.029-m radius, not the 5.532-m radius.

17 WIND ENERGY↗