Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detection Limit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

SuiteGoo [Slides]

SuiteGoo is a liquid product used to detect "undetectable" material traces. It is used when you need to improve detection limits, anywhere where cotton swiping is used, and anywhere where cotton swiping fails. It is also used by law enforcement to find DNA from fingerprints, used by health care to detect the presence of viruses and bacteria, used by emergency response to detect explosive traces, and used by environmental management to detect pollutant traces.

54 ENVIRONMENTAL SCIENCES↗

Sensing Materials for the Detection of Chlorine Gas Using Embedded Piezoresistive Microcantilever Sensors

Embedded piezoresistive microcantilever (EPM) sensors may be constructed for a variety of sensing applications. In each application, a custom sensing material is designed that will respond volumetrically to the desired analyte. Here, we have constructed EPM sensors for the detection of chlorine gas (Cl2). The sensing materials used consisted of polymer matrices combined with sodium iodide crystals. Sensors constructed from a silicone-based matrix exhibited the greatest response to Cl2, with detection limits in an outdoor exposure setting of approximately 20 parts per million.

54 ENVIRONMENTAL SCIENCES↗

Self-interacting inelastic dark matter: a viable solution to the small scale structure problems

Self-interacting dark matter has been proposed as a solution to the small-scale structure problems, such as the observed flat cores in dwarf and low surface brightness galaxies. If scattering takes place through light mediators, the scattering cross section relevant to solve these problems may fall into the non-perturbative regime leading to a non-trivial velocity dependence, which allows compatibility with limits stemming from cluster-size objects. However, these models are strongly constrained by different observations, in particular from the requirements that the decay of the light mediator is sufficiently rapid (before Big Bang Nucleosynthesis) and from direct detection. A natural solution to reconcile both requirements are inelastic endothermic interactions, such that scatterings in direct detection experiments are suppressed or even kinematically forbidden if the mass splitting between the two-states is sufficiently large. Using an exact solution when numerically solving the Schrödinger equation, we study such scenarios and find regions in the parameter space of dark matter and mediator masses, and the mass splitting of the states, where the small scale structure problems can be solved, the dark matter has the correct relic abundance and direct detection limits can be evaded.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

GAS PHASE ABSORPTION SPECTROSCOPY OF C{sub 60}{sup +} AND C{sub 70}{sup +} IN A CRYOGENIC ION TRAP: COMPARISON WITH ASTRONOMICAL MEASUREMENTS

Recent low-temperature laboratory measurements and astronomical observations have proved that the fullerene cation C{sub 60}{sup +} is responsible for four diffuse interstellar bands (DIBs). These absorptions correspond to the strongest bands of the lowest electronic transition. The gas phase spectrum below 10 K is reported here for the full wavelength range encompassed by the electronic transition. The absorption spectrum of C{sub 70}{sup +}, with its origin band at 7959.2 A-ring , has been obtained under similar laboratory conditions. Observations made toward the reddened star HD 183143 were used in a specific search for the absorption of these fullerene cations in diffuse clouds. In the case of C{sub 60}{sup +}, one further band in the astronomical spectrum at 9348.5 A-ring is identified, increasing the total number of assigned DIBs to five. Numerous other C{sub 60}{sup +} absorptions in the laboratory spectrum are found to lie below the astronomical detection limit. Special emphasis is placed on the laboratory determination of absolute absorption cross-sections. For C{sub 60}{sup +} this directly yields a column density, N(C{sub 60}{sup +}), of 2×10{sup 13} cm{sup −2} in diffuse clouds, without the need to rely on theoretical oscillator strengths. The intensity of the C{sub 70}{sup +} electronic transition in the range 7000–8000 Å is spread over many features of similar strength. Absorption cross-section measurements indicate that even for a similar column density, the individual absorption bands of C{sub 70}{sup +} will be too weak to be detected in the astronomical spectra, which is confirmed giving an upper limit of 2 m A-ring to the equivalent width.

79 ASTRONOMY AND ASTROPHYSICS↗

X-RAY EMISSION FROM THE SOMBRERO GALAXY: DISCRETE SOURCES

We present a study of discrete X-ray sources in and around the bulge-dominated, massive Sa galaxy, Sombrero (M104), based on new and archival Chandra observations with a total exposure of {approx}200 ks. With a detection limit of L{sub X} {approx} 10{sup 37} erg s{sup -1} and a field of view covering a galactocentric radius of {approx}30 kpc (11.'5), 383 sources are detected. Cross-correlation with Spitler et al.'s catalog of Sombrero globular clusters (GCs) identified from HST/ACS observations reveals 41 X-ray sources in GCs, presumably low-mass X-ray binaries (LMXBs). Metal-rich GCs are found to have a higher probability of hosting these LMXBs, a trend similar to that found in elliptical galaxies. On the other hand, the four most luminous GC LMXBs, with apparently super-Eddington luminosities for an accreting neutron star, are found in metal-poor GCs. We quantify the differential luminosity functions (LFs) for both the detected GC and field LMXBs, whose power-law indices ({approx}1.1 for the GC-LF and {approx}1.6 for field-LF) are consistent with previous studies for elliptical galaxies. With precise sky positions of the GCs without a detected X-ray source, we further quantify, through a fluctuation analysis, the GC-LF at fainter luminosities down to 10{sup 35} erg s{sup -1}. The derived index rules out a faint-end slope flatter than 1.1 at a 2{sigma} significance, contrary to recent findings in several elliptical galaxies and the bulge of M31. On the other hand, the 2-6 keV unresolved emission places a tight constraint on the field LF, implying a flattened index of {approx}1.0 below 10{sup 37} erg s{sup -1}. We also detect 101 sources in the halo of Sombrero. The presence of these sources cannot be interpreted as galactic LMXBs whose spatial distribution empirically follows the starlight. Their number is also higher than the expected number of cosmic active galactic nuclei (52 {+-} 11 [1{sigma}]) whose surface density is constrained by deep X-ray surveys. We suggest that either the cosmic X-ray background is unusually high in the direction of Sombrero, or a distinct population of X-ray sources is present in the halo of Sombrero.

79 ASTRONOMY AND ASTROPHYSICS↗

THE HST/ACS COMA CLUSTER SURVEY. II. DATA DESCRIPTION AND SOURCE CATALOGS

The Coma cluster, Abell 1656, was the target of an HST-ACS Treasury program designed for deep imaging in the F475W and F814W passbands. Although our survey was interrupted by the ACS instrument failure in early 2007, the partially completed survey still covers {approx}50% of the core high-density region in Coma. Observations were performed for 25 fields that extend over a wide range of cluster-centric radii ({approx}1.75 Mpc or 1{sup 0}) with a total coverage area of 274 arcmin{sup 2}. The majority of the fields are located near the core region of Coma (19/25 pointings) with six additional fields in the southwest region of the cluster. In this paper, we present reprocessed images and SEXTRACTOR source catalogs for our survey fields, including a detailed description of the methodology used for object detection and photometry, the subtraction of bright galaxies to measure faint underlying objects, and the use of simulations to assess the photometric accuracy and completeness of our catalogs. We also use simulations to perform aperture corrections for the SEXTRACTOR Kron magnitudes based only on the measured source flux and its half-light radius. We have performed photometry for {approx}73,000 unique objects; approximately one-half of our detections are brighter than the 10{sigma} point-source detection limit at F814W = 25.8 mag (AB). The slight majority of objects (60%) are unresolved or only marginally resolved by ACS. We estimate that Coma members are 5%-10% of all source detections, which consist of a large population of unresolved compact sources (primarily globular clusters but also ultra-compact dwarf galaxies) and a wide variety of extended galaxies from a cD galaxy to dwarf low surface brightness galaxies. The red sequence of Coma member galaxies has a color-magnitude relation with a constant slope and dispersion over 9 mag (-21 < M {sub F814W} < -13). The initial data release for the HST-ACS Coma Treasury program was made available to the public in 2008 August. The images and catalogs described in this study relate to our second data release.

79 ASTRONOMY AND ASTROPHYSICS↗

Bead-Based Assays for Biodetection: From Flow-Cytometry to Microfluidics

ABSTRACT The potential for the use of biological agents by terrorists is a real threat. Two approaches for detection of biological species will be described: 1) The use of microbead arrays for multiplexed flow cytometry detection of cytokines and botulinum neurotoxin simulant, and 2) a microfluidic platform for capture and separation of different size superparamagnetic nanoparticles followed by on-chip fluorescence detection of the sandwich complex. The methods and automated fluidic systems used for trapping functionalized microbeads will be described. This approach allows sample, assay reagents, and wash solutions to be perfused over a micro-column of beads, resulting in faster and more sensitive assays. The automated fluidic approach resulted in up to five-fold improvements in assay sensitivity/speed as compared to identical assays performed in a typical manual batch mode. A second approach for implementing multiplexed bead-based assays without using flow cytometry detection is currently under development. The goal of the microfluidic-based approach is to achieve rapid (<20 minutes), multiplexed (> 3 bioagents) detection using a simple and low-cost, integrated microfluidic/optical detection platform. Using fiber-optic guided laser-induced fluorescence, assay detection limits were shown to be in the 100’s of picomolar range (10’s of micrograms per liter) for botulinum neurotoxin simulant without any optimization of the microfluidic device or optical detection approach. Video taping magnetic nanoparticle capture and release was used to improve understanding of the process and revealed interesting behavior.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Principle and Uncertainty Quantification of an Experiment Designed to Infer Actinide Neutron Capture Cross-Sections

An integral reactor physics experiment devoted to infer higher actinide (Am, Cm, Bk, Cf) neutron cross sections will take place in the US. This report presents the principle of the planned experiment as well as a first exercise aiming at quantifying the uncertainties related to the inferred quantities. It has been funded in part by the DOE Office of Science in the framework of the Recovery Act and has been given the name MANTRA for Measurement of Actinides Neutron TRAnsmutation. The principle is to irradiate different pure actinide samples in a test reactor like INL’s Advanced Test Reactor, and, after a given time, determine the amount of the different transmutation products. The precise characterization of the nuclide densities before and after neutron irradiation allows the energy integrated neutron cross-sections to be inferred since the relation between the two are the well-known neutron-induced transmutation equations. This approach has been used in the past and the principal novelty of this experiment is that the atom densities of the different transmutation products will be determined with the Accelerator Mass Spectroscopy (AMS) facility located at ANL. While AMS facilities traditionally have been limited to the assay of low-to-medium atomic mass materials, i.e., A < 100, there has been recent progress in extending AMS to heavier isotopes – even to A > 200. The detection limit of AMS being orders of magnitude lower than that of standard mass spectroscopy techniques, more transmutation products could be measured and, potentially, more cross-sections could be inferred from the irradiation of a single sample. Furthermore, measurements will be carried out at the INL using more standard methods in order to have another set of totally uncorrelated information.

74 ATOMIC AND MOLECULAR PHYSICS↗

On absorption by hot interstellar gas. II - The 5303-A forbidden line of Fe XIV

Spectroscopic observations of 29 stars at 5303 A obtained with the coude spectrograph on the 2.7-m reflector at McDonald Observatory during 1979-1983 are reported. Instrumental FWHM resolution is 27, 54, or 10 pm, and detection limits near 100 fm equivalent width are obtained in optimal cases. The results are presented in tables and a diagram. No absorption attributable to Fe XIV in hot interstellar gas is detected except for HD 93521, on Apr. 10, 1981, only. This absorption can be located either in interstellar gas at 1.2 million K or less with an Fe XIV/Fe X ratio greater than 3 or in hot gas confined in an inhomogeneous stellar corona.

Hobbs, L. M.↗

High Sensitivity, Low Power Nano Sensors and Devices for Chemical Sensing

The chemical sensor market has been projected to grow to better than $40 billion dollars worldwide within the next 10 years. Some of the primary motivations to develop nanostructured chemical sensors are monitoring and control of environmental pollution; improved diagnostics for consumption; improvement in measurement precision and accuracy; and improved detection limits for Homeland security, battlefield environments, and process and quality control of industrial applications. In each of these applications, there is demand for sensitivity, selectivity and stability of environmental and biohazard detection and capture beyond what is currently commercially available. Nanotechnology offers the ability to work at the molecular level, atom by atom, to create large structures with fundamentally new molecular organization. It is essentially concerned with materials, devices, and systems whose structures and components exhibit novel and significantly improved physical, chemical and biological properties, phenomena, and process control due to their nanoscale size. One such nanotechnology-enabled chemical sensor has been developed at NASA Ames leveraging nanostructures, such as single walled carbon nanotubes (SWNTs) and metal oxide nanobelts or nanowires, as a sensing medium bridging a pair of interdigitated electrodes (IDE) realized through a silicon-based microfabrication and micromachining technique. The DE fingers are fabricated on a silicon substrate using standard photolithography and thin film metallization techniques. It is noteworthy that the fabrication techniques employed are not confined to the silicon substrate. Through spin casting and careful substrate selection (i.e. clothing, glass, polymer, etc.), additional degrees of freedom can be exploited to enhance sensitivity or to conform to unique applications. Both in-situ growth of nanostructured materials and casting of nanostructured dispersions were used to produce analogous chemical sensing devices.

Li, Jing↗

The art and power of data imaging

Data imaging and visual data assessment are veritable gold mines in the scientist's quest to understand and accurately interpret numerical data. Graphical displays of various aspects of a dataset offer the analyst insight to the data that no mathematical computation or statistic can provide. It is difficult, at best, for even a skilled and observant statistician to understand the underlying structure of a dataset. Often, there is either too little data to get a good 'picture' of the structure that might be present or there is so much data that one cannot readily assimilate it. Of course, the latter problem (too much data) is, in reality, no problem at all given the abilities of modern computers and software systems to manage large amounts of data. Advances in computer technology and the advent of the global positioning satellite system have enabled scientists from many fields of endeavor to collect and view data in its spatial context. Visual images constructed from spatially referenced data reveal the inherent richness and structure in the data and lead to more informed conclusions. So powerful is data collected with spatial context that a relatively new branch of mathematical statistics, geo-spatial statistics, has emerged. Geo-spatial statistics seek to exploit this context rich data form to better understand the spatial and co-relationships that might exist, but would be otherwise hidden in tabular data or obscured with classic statistical approaches. This paper (and accompanying presentation) will show the power that visual data assessment possesses to understand radiological scanning data and to make confident and accurate decisions based on the data images. It will challenge the traditional mathematical concept of detection limits for scanning. It will demonstrate that more data, even if the individual datum comprising the dataset is of 'poorer quality' (i.e., has a larger uncertainty and, thus, a larger calculated minimum detection value), is significantly more powerful than a smaller dataset comprised of higher quality measurements. This presentation will cause the open-minded health physicist to rethink how they prescribe, collect, evaluate, and make decisions based upon radiological scan data. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical resonant sensors: a method to reduce the effect of thermal drift

The use of a whispering gallery mode (WGM) resonator with an ultrahigh quality factor Q is promising in highly sensitive, label-free, lab-on-a-chip sensor applications. We investigated a novel method of using the differential frequency of TE and TM modes to reduce the thermal noise baseline, which commonly limits the sensitivity of WGM sensors. We studied the temperature dependence of WGM based sensors and experimentally demonstrated the reduction of temperature fluctuation and thus a significant improvement in the practical sensor detection limit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Continued Evaluation of the Use of a Raman Spectrometer for H-Canyon Dissolver Monitoring

Remote monitoring of dissolver activities in H-Canyon can help operators avoid delays associated with excessive levels of fuel fragments remaining after a run. SRNL has proposed that effective monitoring can be achieved by using a Raman spectrometer to measure NO 2 concentrations in the offgas stream sampled from the facility stack. Prior work (SRNL-STI-2021-00451) measuring the offgas from one dissolution batch of High Flux Isotope Reactor (HFIR) fuel suggested a relationship between %NO 2 levels and fragment height. Herein, we report the results of monitoring and analysis of the dissolution of four batches of Material Test Reactor (MTR) fuel. A rigorous quantitative relationship between %NO 2 measurements and fragment heights could not be established, due to high uncertainties associated with both measurements. Uncertainties with gas measurements are associated with the %NO 2 levels in the offgas being close to the detection limit for the analyzer. Alternative gas measurement strategies are discussed which could improve sensitivity and reduce uncertainty. Limitations to the precision of the probe measurements are also discussed. It is also noted that the offgas is an average of the products from simultaneous dissolution of elements in multiple wells. Detection of a high fragment height level in an individual well may be hindered by low levels in other wells.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SEARCHING FOR NEUTRAL HYDROGEN HALOS AROUND z ∼ 2.1 AND z ∼ 3.1 Lyα EMITTING GALAXIES

We search for evidence of diffuse Lyα emission from extended neutral hydrogen surrounding Lyα emitting galaxies (LAEs) using deep narrow-band images of the Extended Chandra Deep Field South. By stacking the profiles of 187 LAEs at z = 2.06, 241 LAEs at z = 3.10, and 179 LAEs at z = 3.12, and carefully performing low-surface brightness photometry, we obtain mean surface brightness maps that reach 9.9, 8.7, and 6.2 × 10{sup –19} erg cm{sup –2} s{sup –1} arcsec{sup –2} in the emission line. We undertake a thorough investigation of systematic uncertainties in our surface brightness measurements and find that our limits are 5-10 times larger than would be expected from Poisson background fluctuations; these uncertainties are often underestimated in the literature. At z ∼ 3.1, we find evidence for extended halos with small-scale lengths of 5-8 kpc in some but not all of our sub-samples. We demonstrate that sub-samples of LAEs with low equivalent widths and brighter continuum magnitudes are more likely to possess such halos. At z ∼ 2.1, we find no evidence of extended Lyα emission down to our detection limits. Through Monte-Carlo simulations, we also show that we would have detected large diffuse LAE halos if they were present in our data sets. We compare these findings to other measurements in the literature and discuss possible instrumental and astrophysical reasons for the discrepancies.

79 ASTRONOMY AND ASTROPHYSICS↗

Sub-m s−1 upper limits from a deep HARPS-N radial-velocity search for planets orbiting HD 166620 and HD 144579

ABSTRACT Minimizing the impact of stellar variability in radial velocity (RV) measurements is a critical challenge in achieving the 10 cm s−1 precision needed to hunt for Earth twins. Since 2012, a dedicated programme has been underway with HARPS-N, to conduct a blind RV rocky planets search (RPS) around bright stars in the Northern hemisphere. Here we describe the results of a comprehensive search for planetary systems in two RPS targets, HD 166620 and HD 144579. Using wavelength-domain line-profile decorrelation vectors to mitigate the stellar activity and performing a deep search for planetary reflex motions using a trans-dimensional nested sampler, we found no significant planetary signals in the data sets of either of the stars. We validated the results via data-splitting and injection recovery tests. Additionally, we obtained the 95th percentile detection limits on the HARPS-N RVs. We found that the likelihood of finding a low-mass planet increases noticeably across a wide period range when the inherent stellar variability is corrected for using scalpelsU-vectors. We are able to detect planet signals with Msin i ≤ 1 M⊕ for orbital periods shorter than 10 d. We demonstrate that with our decorrelation technique, we are able to detect signals as low as 54 cm s−1, which brings us closer to the calibration limit of 50 cm s−1 demonstrated by HARPS-N. Therefore, we show that we can push down towards the RV precision required to find Earth analogues using high-precision radial velocity data with novel data-analysis techniques.

Anna John, A. (ORCID:0000000217156939)↗

Surface reconstructions in molecular beam epitaxy of SrTiO{sub 3}

We show that reflection high-energy electron diffraction (RHEED) can be used as a highly sensitive tool to track surface and resulting film stoichiometry in adsorption-limited molecular beam epitaxy of (001) SrTiO{sub 3} thin films. Even under growth conditions that yield films with a lattice parameter that is identical to that of stoichiometric bulk crystals within the detection limit of high-resolution x-ray diffraction (XRD), changes in surface reconstruction occur from (1 × 1) to (2 × 1) to c(4 × 4) as the equivalent beam pressure of the Ti metalorganic source is increased. These surface reconstructions are correlated with a shift from mixed SrO/TiO{sub 2} termination to pure TiO{sub 2} termination. The crossover to TiO{sub 2} surface termination is also apparent in a phase shift in RHEED oscillations observed at the beginning of growth. Comparison with prior results for carrier mobilities of doped films shows that the best films are grown under conditions of a TiO{sub 2}-saturated surface [c(4 × 4) reconstruction] within the XRD growth window.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Volcanic eruption detection with TOMS

The Nimbus 7 Total Ozone Mapping Spectrometer (TOMS) is designed for mapping of the atmospheric ozone distribution. Absorption by sulfur dioxide at the same ultraviolet spectral wavelengths makes it possible to observe and resolve the size of volcanic clouds. The sulfur dioxide absorption is discriminated from ozone and water clouds in the data processing by their spectral signatures. Thus, the sulfur dioxide can serve as a tracer which appears in volcanic eruption clouds because it is not present in other clouds. The detection limit with TOMS is close to the theoretical limit due to telemetry signal quantization of 1000 metric tons (5-sigma threshold) within the instrument field of view (50 by 50 km near the nadir). Requirements concerning the use of TOMS in detection of eruptions, geochemical cycles, and volcanic climatic effects are discussed.

Krueger, Arlin J.↗

The Orbiter Stability Experiment on STS-40

The Orbiter Stability Experiment (OSE) was developed to evaluate the steadiness of the STS Orbiter as a potential platform for instrumentation that would image the Sun in its extreme ultraviolet and soft X-ray radiations. We were interested in any high frequency motions of the Orbiter's orientation due to normal operations and manned activities. Preliminary results are presented of the observations. Other than the expected slow motion of the Orbiter within the specified angular deadband of 0.1 degrees during the observations, it was found that high frequency (above 1 Hz) angular motions (jitter) were not detectable at the 0.25 arc sec detection limit of the most sensitive detector, for most of the period of observation. No high frequency motions were recorded during intervals that were identified with vernier thruster firings. However, one short interval with detectable spectral power to a frequency of 10 Hz has been found to date. It has not yet been correlated with a particular activity going on at the time. The results of the observations may also be of value in assessing perturbations to the Orbiter's micro-gravity environment produced by normal operations.

Neupert, Werner M.↗