Implementation of thermal residual stresses in the analysis of fiber bridged matrix crack growth in titanium matrix composites

In this research, thermal residual stresses were incorporated in an analysis of fiber-bridged matrix cracks in unidirectional and cross-ply titanium matrix composites (TMC) containing center holes or center notches. Two TMC were investigated, namely, SCS-6/Timelal-21S laminates. Experimentally, matrix crack initiation and growth were monitored during tension-tension fatigue tests conducted at room temperature and at an elevated temperature of 200 C. Analytically, thermal residual stresses were included in a fiber bridging (FB) model. The local R-ratio and stress-intensity factor in the matrix due to thermal and mechanical loadings were calculated and used to evaluate the matrix crack growth behavior in the two materials studied. The frictional shear stress term, tau, assumed in this model was used as a curve-fitting parameter to matrix crack growth data. The scatter band in the values of tau used to fit the matrix crack growth data was significantly reduced when thermal residual stresses were included in the fiber bridging analysis. For a given material system, lay-up and temperature, a single value of tau was sufficient to analyze the crack growth data. It was revealed in this study that thermal residual stresses are an important factor overlooked in the original FB models.

Bakuckas, John G., Jr.↗

Wear of iron and nickel in corrosive liquid environments

Friction and wear behavior of Fe and Ni sliding on aluminum oxide in aerated sulfuric acid and hydrochloric acid were investigated. The results show that the concentration of acid is an important factor in controlling the metal loss caused by wear corrosion processes in the acids. At very dilute acid concentration (10 to the -4 N), Fe behaves differently from Ni. Fe develops a soft, friable deposit, while Ni develops no corrosion layer. The formation and removal of the corrosion deposit on Fe resulted in high metal loss and coefficient of friction, as compared to the relatively low metal loss and coefficient of friction observed for Ni. At slightly higher acid concentration (10 to the -3 and 10 to the -2 N), no corrosion products were produced on both Fe and Ni. Wear of Fe and Ni was generally at a minimum. At higher acid concentration (10 to the -1 N and above), loss of Fe and Ni increased as the acid concentration increased. In sulfuric acid the maximum loss of both Fe and Ni was at 7.5 N (30%) concentration, and the metal losses of both Fe and Ni dropped markedly at 15 N (50%) and above. In hydrochloric acid, however, the Fe loss continued to increase with the increase of acid concentration, and the maximum Fe loss occurred in the most concentrated acid (12.1 N, 37%). There were variations in loss with Ni from specimen to specimen examined in hydrochloric acids (10 to the -1 N and above). The coefficient of friction for Ni increased slightly with an increase in acid concentration up to 10 to the -2 N. When corrosion started to dominate in the wear-corrosion process, the coefficient of friction decreased in both sulfuric and hydrochloric acids at 10 to the -1 N and above.

Miyoshi, Kazuhisa↗

Wear of iron and nickel in corrosive liquid environments

Friction and wear behavior of Fe and Ni sliding on aluminum oxide in aerated sulfuric acid and hydrochloric acid were investigated. The results show that the concentration of acid is an important factor in controlling the metal loss caused by wear corrosion processes in the acids. At very dilute acid concentration (10 to the -4 N), Fe behaves differently from Ni. Fe develops a soft, friable deposit, while Ni develops no corrosion layer. The formation and removal of the corrosion deposit on Fe resulted in high metal loss and coefficient of friction, as compared to the relatively low metal loss and coefficient of friction observed for Ni. At slightly higher acid concentration (10 to the -3 and 10 to the -2 N), no corrosion products were produced on both Fe and Ni. Wear of Fe and Ni was generally at a minimum. At higher acid concentration (10 to the -1 N and above), loss of Fe and Ni increased as the acid concentration increased. In sulfuric acid the maximum loss of both Fe and Ni was at 7.5 N (30 percent) concentration, and the metal losses of both Fe and Ni dropped markedly at 15 N (50 percent) and above. In hydrochloric acid, however, the Fe loss continued to increase with the increase of acid concentration, and the maximum Fe loss occurred in the most concentrated acid (12.1 N, 37 percent). There were variations in loss with Ni from specimen to specimen examined in hydrochloric acids (10 to the -1 N and above). The coefficient of friction for Ni increased slightly with an increase in acid concentration up to 10 to the -2 N. When corrosion started to dominate in the wear-corrosion process, the coefficient of friction decreased in both sulfuric and hydrochloric acids at 10 to the -1 N and above.

Miyoshi, Kazuhisa↗

The inhibition of RANKL expression in fibroblasts attenuate CoCr particles induced aseptic prosthesis loosening via the MyD88-independent TLR signaling pathway

Periprosthetic osteolysis and aseptic loosening are mainly caused by wear particles (Ps) that are generated from friction interfaces. However, the mechanisms underlying the development of aseptic loosening remain unclear. Therefore, we aimed toclarify how the myeloid differentiation factor 88 (MyD88)-independent Toll-like receptor (TLR) signaling pathway mediates cobalt and chromium (CoCr)-Ps-induced osteolysis. We quantified the expression levels of TLRs, MyD88, RANKL, and inflammatory factors in patients experiencing aseptic loosening after primary total hip arthroplasty (THA) with metal-on-metal (MoM) bearings and hip osteoarthritis (hOA). We observed the in vitro and in vivo levels of RANKL, TLRs, and MyD88 in fibroblasts challenged with CoCr Ps by applying shMyD88 interference lentivirus vectors to block the MyD88-independent TLR pathway. The levels of TLRs, MyD88, RANKL, and inflammatory factors in the revision THA (rTHA) with MoM group were higher than those in the hOA group. Our data collectively revealed that inhibiting MyD88 expression could reduce osteoclastogenesis in vitro and CoCr-Ps-induced osteolysis in vivo. Our findings suggested that osteoclastogenesis is promoted by the CoCr-Ps-induced expression of RANKL in fibroblasts and that MyD88 is a potential target in the treatment of wear Ps-induced osteolysis.

60 APPLIED LIFE SCIENCES↗

Discrete Measurements of the Least Horizontal Principal Stress from Core Data: An Application of Viscoelastic Stress Relaxation

Summary The emerging Paradox Oil Play in southeastern Utah is among the most significant unconventional plays in the western USA. The mean total undiscovered oil resources within just the Pennsylvanian Cane Creek interval of the Paradox Basin are believed to exceed 215 million barrels. However, to date, less than 5% (~9 million barrels) of the total Cane Creek resource has been produced from fewer than 40 wells, and only approximately one-half of those are horizontal wells. More than 95% of production is from the central Cane Creek Unit (CCU). Natural fractures are a key feature of many production wells, but stimulation by induced hydraulic fractures is not consistently successful. We hypothesize that more effective production in this play will rely on better fundamental characterization, especially on better quantification of the state of stress. Approximately 110 ft of core, well logs, and a diagnostic fracture injection test (DFIT) were acquired from the State 16-2 well within the CCU. With these data, we applied two methods to constrain and clarify the state of stress. The first technique, the Simpson’s coefficient method, provides lower bounds on the two horizontal principal stresses and relies on only limited data. Alternatively, the viscoelastic stress relaxation (VSR) method is used to estimate the least horizontal principal stress, building on observations that principal stresses become more isotropic as the viscous behavior of a rock is more pronounced. Results of these two methods support the hypothesis that the state of stress in the CCU of the Paradox Basin is nearly lithostatic and isotropic. Other factors consistent with this hypothesis include high formation pore pressure, which tends to reduce the possible stress states by changing the frictional failure equilibrium; lack of induced fractures in the core, which should be present in the case of stress anisotropy; and interbedded halite layers, which given their high degree of ductility, probably lead to greater VSR for the entire sedimentary package.

Energy & Fuels↗

Study of the lubricant properties of carbon nonfluoride: (CF subx) subn

Friction and wear tests were performed with rubbed carbon monofluorides derived from different types of carbon. Best results were given by fluorated artificial graphite and coke. The coefficient of friction is practically independent of the fluorine-to-carbon ratio x where 0 x 1, but wear decreases by a factor of 6 as x tends toward 1. For a range of variation of the severity factor (PV) expressed in Newtons/cm. sec (where P is the average pressure and V the velocity) contained between 1,000 and 200,000, the wear measured with carbon monofluoride is significantly lower than that obtained with MoS2. A transfer film or third body which protects the surfaces is formed with carbon monofluoride, and beyond 400 C, thick and fragile oxide coatings are also formed.

Play, D.↗

MS212--A Homogeneous Sputtered Solid Lubricant Coating for Use to 800 C

Composite coatings containing chromium carbide, stable fluorides and silver were prepared by magnetron sputtering. The microstructure of the coatings is very homogeneous compared to that of plasma sprayed and sintered versions of the same chemical composition. Friction and wear of MS212-coated and baseline uncoated aluminum and Inconel X-750 are compared. At room temperature, the friction and wear of coated aluminum is dramatically better compared to the baseline. The acceptable load is limited by deformation of the soft aluminum substrate. In the case of the nickel alloy, lower friction is observed for the coated alloy at all temperatures up to the maximum test temperature of 800 C. Pin wear factors for sliding against the coated alloy are lower than the baseline at room temperature and 350 C, and comparable to baseline wear at higher test temperatures. Low baseline wear at high temperatures is due to the lubricious nature of the natural oxides formed on nickel-chromium alloys in a hot, oxidizing atmosphere. No load limit was found for coated Inconel X-750 at loads up to five times the load limit for coated aluminum.

Sliney, Harold E.↗

Body Building Boons From Apollo

The Exer-Genie program utilizes familiar types of exercise, such as isometrics (pushing or pulling against an immovable object) and isotonics (motive exercises such as calisthenics or weight lifting) but with the important added factor of controlled resistance. The device is an arrangement of hand grips and nylon cord wrapped around an aluminum shaft. Controlled friction determines the resistance and the user can set the amount of resistive force to his own physical conditioning needs. Since Apollo days, the Exer-Genie and a similar device called the Apollo Exerciser have found wide acceptance among professional, collegiate and high school athletic teams, and among the growing number of individuals interested in physical fitness. These devices are efficient and economical replacements for conventional conditioning equipment and extremely versatile, allowing more than 100 basic exercises for shaping up specific muscle groups.

Source record↗

Structural Analysis Findings of Open Spelter Socket Cable Terminations

A three-dimensional nonlinear finite element model of a representative open spelter socket termination was developed to examine the underlying mechanics of load transfer from a structural cable through the termination, the sensitivity of the joint design to wire brooming, zinc material nonlinearity, contact friction between the zinc and socket, voids within the zinc, and, finally, the effects of repeated loading on the joint. Primary factors affecting open spelter socket design are cast zinc plastic flow, depth of zinc slug seating, and quality of wire brooming. Zinc plasticity and proper brooming allows for efficient load transfer by developing confining pressure on the broomed wires in the narrow part of the socket, which keep the wires from pulling out of the zinc and shift failure to occur outside the socket. Highest wire stresses in the cable occur in the outer ring adjacent to the termination. While industry use of stay cables are typically designed to carry less than half the rated breaking force in aggregate, the constituent stresses within the zinc and the wires have the potential to exceed their respective allowable in operation and should be evaluated for fatigue- and creep-critical applications.

Pavel Babuska↗

Modelling of the effect of process parameters on tensile strength of friction stir welded aluminium alloy joints

Friction stir welding (FSW) process is a promising solid-state joining process with the potential to join low-melting point material, particularly, aluminium alloy. The most attractive reason for joining aluminium alloy with this process is the avoidance of the solidification defects formed by conventional fusion welding processes. In this article, an attempt has been made to develop an empirical relationship between FSW variables and tensile strength. Central composite rotatable design was used by considering four factor and five levels, which enables to quantify the direct and interactive effect of four numeric factors, that is, tool rotational speed, welding speed, axial force, and tapered pin diameter on the tensile strength. The developed relationship is useful for prediction of tensile strength in friction stir welded AA6082 aluminium alloy joints at 95% confidence level. It will also be helpful for selection of process variable to obtain desired strength of the joint. Furthermore, the optimized capabilities in design-expert software were used to numerically optimize the input parameters. At the optimal parameters, three experiments were conducted to compare the predicted value of tensile strength with the experimental value.

36 MATERIALS SCIENCE↗

Voltage transients elicited by sudden step-up of auxin

It is hypothesized (i) that the molecular mechanism for the reception of friction and flexure and the mechanism by which auxin enhances ethylene production have in common a release of free calcium into the cytosol, (ii) that elevated cytosolic calcium initiates vesicle exocytosis, and (iii) that the vesicles release a factor or set of factors which depolarizes the plasmalemma and promotes ethylene synthesis. One consequence of such exocytosis should be small, extracellularly observable voltage transients. Transients, ranging in size up to 600 microvolts and possessing risetimes (10-90%) of approximately 200 ms, are known to be elicited in etiolated stems of Pisum sativum L. by friction and are here shown to be elicited by sudden increase of auxin concentration and also by a Ca2+ ionophore.

Calcium/metabolism↗

Assessment of bearing capacity of axially loaded monopiles based on centrifuge tests

The monopile has been widely used to support offshore and coastal structures. A series of centrifuge tests has been performed to investigate the bearing capacity of large diameter monopiles in sandy soil. Both static tests and cyclic tests have been conducted for open-ended and close-ended model piles, and the effects of influence factors, such as loading rates, embedment depths, and loading histories are considered. The piles are then loaded by a sequence of compressive-tensile loadings to estimate the tension capacity, from which the shaft friction is derived. The cyclic load tests are performed with five varying load intensities, and the accumulated settlement is assessed. The centrifuge tests indicate that the pile bearing capacity tends to increase with the initial penetration depth, and the stress state of soil greatly influences the pile behavior. The tensile shaft friction is smaller compared to the compression test. The capacities of the piles reduce significantly under the axial cyclic load, and the maximum cyclic load intensity should be limited to 75% of the ultimate bearing capacity. The API design method is used to calibrate with the centrifuge test results. The method overestimates the bearing capacity at larger depths, and a conservative reduction factor is required.

17 WIND ENERGY↗

Study on the dynamics responses of a transmission system made from carbon nanotubes

A rotational transmission system from coaxial carbon nanotubes (CNTs) is investigated using a computational molecular dynamics approach. The system consists of a motor from a single-walled carbon nanotube and a bearing from a double-walled carbon nanotube. The motor has a high fixed rotational frequency and the two ends of the outer tube in the bearing are fixed. The inner tube in the bearing works as a rotor. Because of the interlayer friction in the bearing, configurations of the joint between the adjacent ends of motor and rotor have significant effects on rotational transmission properties. Four factors are considered in simulation, i.e., the bonding types of atoms (sp{sup 1} and sp{sup 2}) on the ends of motor and rotor, the difference between motor and rotor radii, the rotational speed of motor, and the environmental temperature. It is found that the synchronous transmission happens if the sp{sup 1} atoms on the jointed ends of motor and rotor are bonded each other and become new sp{sup 2} atoms. Therefore, the lower difference between radii of motor and rotor, higher temperature of environment leads to synchronous rotational transmission easily. If the environmental temperature is too low (e.g., <150 K), the end of motor adjacent to rotor is easily under buckling and new sp{sup 2} atoms appear, too. With capped CNTs or higher radii difference between rotor and motor at an appropriate temperature, a stable asynchronous rotation of rotor can be generated, and the rotor's frequency varying linearly with motor's frequency between 230 and 270 GHz. A multi-signal transmission device combined with oscillating and rotational motion is proposed for motor and stator shares a same size in radius.

42 ENGINEERING↗

Surface Chemistry, Friction, and Wear Properties of Untreated and Laser-Annealed Surfaces of Pulsed-Laser-Deposited WS(sub 2) Coatings

An investigation was conducted to examine the surface chemistry, friction, and wear behavior of untreated and annealed tungsten disulfide (WS2) coatings in sliding contact with a 6-mm-diameter 440C stainless-steel ball. The WS2 coatings and annealing were performed using the pulsed-laser-deposition technique. All sliding friction experiments were conducted with a load of 0.98 N (100 g), an average Hertzian contact pressure of 0.44 GPa, and a constant rotating speed of 120 rpm. The sliding velocity ranged from 31 to 107 mm/s because of the range of wear track radii involved in the experiments. The experiment was performed at room temperature in three environments: ultrahigh vacuum (vacuum pressure, 7X(exp -10) Pa), dry nitrogen (relative humidity, less than 1 percent), and humid air (relative humidity, 15 to 40 percent). Analytical techniques, including scanning electron microscopy (SEM), energy-dispersive x-ray spectroscopy (EDX), x-ray photo electron spectroscopy (XPS), surface profilometry, and Vickers hardness testing, were used to characterize the tribological surfaces of WS2 coatings. The results of the investigation indicate that the laser annealing decreased the wear of a WS2 coating in an ultrahigh vacuum. The wear rate was reduced by a factor of 30. Thus, the laser annealing increased the wear life and resistance of the WS2 coating. The annealed WS 2 coating had a low coefficient of friction (less than O.1) and a low wear rate ((10(exp -7) mm(exp 3)/N-m)) both of which are favorable in an ultrahigh vacuum.

Miyoshi, Kazuhisa↗

Application of algebraic-RNG eddy viscosity model to simulation of transitional boundary layer flow

An algebraic eddy-viscosity model is derived from the renormalization group (RNG) theory of turbulence. A new length scale, based on boundary layer characteristics (displacement thickness, shape factor), is proposed. The model was applied to transitional boundary layer flow over a flat plate. Integral characteristics, such as the total skin friction coefficient, and mean velocity profile across the boundary layer, are found to be in good agreement with experimental data.

Yakhot, Alexander↗

Magnetic reconnection in partially ionized plasmas

We review the theory of magnetic reconnection in weakly ionized gases. The theory is relevant to reconnection in the interstellar medium, protostellar and protoplanetary disks, the outer envelopes of cool stars, and a new laboratory experiment. In general, partial ionization introduces three effects beyond the obvious one: increased resistivity due to electron-neutral collisions. First, magnetic neutral sheets are steepened by plasma-neutral drift, setting up the conditions for reconnection. Second, when ion-neutral friction is strong, the effective ion mass is increased by {rho}/{rho}{sub i}, the ratio of total to plasma mass density. This reduces the Alfven speed v{sub A} by a factor of {radical}({rho}/{rho}{sub i}) and increases the ion skin depth {delta}{sub i} by {radical}({rho}/{rho}{sub i}). As a result, entrainment of neutrals slows MHD reconnection but permits the onset of fast collisionless reconnection at a larger Lundquist number S, or for a longer current sheet, than in the fully ionized plasma case. These effects, taken together, promote fast collisionless reconnection when the ionization fraction is of order 10% to 1%, but reconnection is slowed down for much smaller ionization fractions. Finally, ion-neutral friction can be a strong heating mechanism throughout the inflow and outflow regions. These effects are under study at the Magnetic Reconnection Experiment (MRX).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of cone-wedge-ring-expansion test to evaluate the tensile HOOP properties of nuclear fuel cladding

Here, we report the development of a cone wedge ring expansion test method to determine the tensile hoop properties of irradiated nuclear fuel cladding in a hot cell. A closed-form solution was developed to explicitly relate the hoop stress σ θ to the axial piston loading using the scale factor χ and the shear stress correction factor α, where the χ and α factors are used to convert the applied piston load and the radial dilatation of the ring into the tensile hoop stress-strain curve. The applicability of this new test method was demonstrated by successfully evaluating ring specimens of Zr-4 alloy to failure. The ring specimens deformed uniformly in the axial and circumferential directions until onset of necking. The χ and α factors were successfully determined by using a finite-element stress analysis that benchmarked with applied test load and total work to account for frictional forces and the associated energies dissipation between the different sliding components of the testing system. The tensile hoop strength values obtained using the proposed cone-wedge-ring-expansion test method were 10% higher than values obtained from the tensile evaluation of the cladding material along the axial direction. In conclusion, the variability in results was found to be within the range reported in the literature.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Computational Fluid Dynamics Analysis of Flexible Duct Junction Box Design

IBACOS explored the relationships between pressure and physical configurations of flexible duct junction boxes by using computational fluid dynamics (CFD) simulations to predict individual box parameters and total system pressure, thereby ensuring improved HVAC performance. Current Air Conditioning Contractors of America (ACCA) guidance (Group 11, Appendix 3, ACCA Manual D, Rutkowski 2009) allows for unconstrained variation in the number of takeoffs, box sizes, and takeoff locations. The only variables currently used in selecting an equivalent length (EL) are velocity of air in the duct and friction rate, given the first takeoff is located at least twice its diameter away from the inlet. This condition does not account for other factors impacting pressure loss across these types of fittings. For each simulation, the IBACOS team converted pressure loss within a box to an EL to compare variation in ACCA Manual D guidance to the simulated variation. IBACOS chose cases to represent flows reasonably correlating to flows typically encountered in the field and analyzed differences in total pressure due to increases in number and location of takeoffs, box dimensions, and velocity of air, and whether an entrance fitting is included. The team also calculated additional balancing losses for all cases due to discrepancies between intended outlet flows and natural flow splits created by the fitting. In certain asymmetrical cases, the balancing losses were significantly higher than symmetrical cases where the natural splits were close to the targets. Thus, IBACOS has shown additional design constraints that can ensure better system performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗