Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fluence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Edge-localized-mode simulation in CFETR steady-state scenario

We report the EPED1 model and self-consistent core-pedestal coupling in integrated modeling are used to design the pedestal structure of the China Fusion Engineering Testing Reactor (CFETR) steady-state scenario. The key parameters, such as β p and q 95 , are based on the grassy edge-localized-mode (ELM) experimental database. In this work, we use the BOUT++ six-field two-fluid code to simulate the onset of the ELM in the CFETR steady-state scenario. The ELM size is around 0.2% in nonlinear simulations, which is in the experimental range of the grassy ELM discharges, 0.1%–1% observed in multiple tokamak devices. Linear and nonlinear simulations show that the dominant high-n ballooning modes peak around n = 40. Compared to type-I ELM crashing dynamics, grassy ELM crashing has a smaller initial crash and is then followed by three phases of turbulence spreading, which are dominated by multi-modes, a high-n mode of n = 45 and low-n mode of n = 5, respectively. In contras to type-I ELM, the perturbation of the high-n mode has a narrow width around ψ = 0.95, and magnetic island formation and reconnection occur only beyond ψ = 0.95, leading to a small initial crash. Mode–mode interaction in the multi-mode coexistence stage stops the growth of individual modes and reduces the transport of particles and heat, and these are the two reasons why the ELM size is small. In–out asymmetry of transient heat flux with a ratio of E out /E in = 3.5 is found during grassy ELM crash. The rise and delay times of the heat flux match the calculation from the free-streaming model. To evaluate the erosion of the divertor target, the energy fluence at the outer divertor target is calculated, which is 0.029 MJ m -2 , 5.5 times smaller than the tungsten melting limit 0.16 MJ m -2 . The calculated energy fluency still follows the experimental scaling law from type-I ELM experiments. The fluctuation eddies in the toroidal direction show a filament structure at the outer mid-plane. Parallel heat flux patterns with a toroidal mode number n = 10 are found at the outer divertor with an amplitude of 680 MW m -2 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

AR reactor neutronics multi-code validation*

The affordable, robust, compact (ARC) reactor is a tokamak fusion reactor concept currently under development by Commonwealth Fusion Systems and Massachusetts Institute of Technology. There are three important neutronics considerations for the operation of the ARC reactor: (1) breeding of enough tritium in the blanket to sustain the D–T reaction in the plasma; (2) ensuring low fluence on the superconducting toroidal field coils; and (3) assessing neutron volumetric heating in structural components. Here, this work aims to perform a validation of the neutronics analysis approach by code-to-code comparison. State-of-the-art software stacks are employed for the neutronics analysis of the ARC reactor, and a computer-aided design (CAD) model is used directly for Monte Carlo (MC) neutron transport calculations. Three software stacks, Attila-MCNP, OpenMC-DAGMC, and Shift-DAGMC, are used to perform neutronic analyses of a 90° sector CAD model of the ARC reactor. In conclusion, results show that the flux tallies calculated by the three software stacks are very close. Also, the volumetric heating and tritium breeding values have less than 0.6% relative difference between codes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deuterium supersaturated surface layer in tungsten: ion energy dependence

Abstract Properties of deuterium (D) supersaturated surface layers (DSSLs) formed in tungsten (W), such as thickness, internal microstructures, and D retention, are experimentally investigated as a function of the incident ion energy, E i . W samples were exposed to D plasmas in the PISCES-A linear plasma device in a range of E i ∼ 45–175 eV, while other plasma exposure parameters were fixed: sample temperature, T s , ∼423 K, ion flux, Γ i , ∼1.2 × 10 21 m −2 s −1 , and fluence, Φ i , ∼3.0 × 10 24 m −2 . High-resolution, cross-sectional, transmission electron microscopy observations confirm that (1) a DSSL forms even at the lowest E i ∼ 45 eV, (2) the DSSL thickness, Δ t DSSL , is found to decrease with decreasing E i from ∼11–12 nm at E i ∼ 175 eV to ∼5–6 nm at ∼45 eV, and to agree with approximately the maximum implantation depth calculated using SDTrimSP, and (3) high-density D nanobubbles with a diameter of ∼1 nm or less exist inside the DSSL, which is deemed to validate a theory-predicted vacancy stabilization process due to trapping of a solute D atom(s). Utilizing a D areal density of ∼4.2 × 10 19 m −2 in the first 14 nm from the surface at E i ∼ 75 eV from nuclear reaction analysis and the measured E i dependence of Δ t DSSL , our previous laser-induced breakdown spectroscopy data is updated: both dynamic and static D retention increase with decreasing E i , and the D/W atomic fraction during plasma exposure reaches ∼0.3 at E i ∼ 45 eV. A possible DSSL formation mechanism is proposed.

Physics↗

Reply to Comment on ‘Deuterium supersaturated surface layer in tungsten: ion energy dependence’

Abstract We reply to the comment by Li et al (submitted to Nucl. Fusion with this response) on our recent paper Nishijima et al (2023 Nucl. Fusion 63 126003). In this response, we address the existence of an incident ion energy, E i , threshold for the deuterium (D) supersaturated surface layer (DSSL) formation with a newly conducted D plasma exposure experiment at E i ∼ 20 eV. It is also further demonstrated, based on new experiments where the ion flux, fluence, and sample temperature are scanned, that non-kinetic (ballistic) processes play a role in the DSSL formation and growth. In addition, the effect of impurities in our plasma is discussed also with a new analysis of the surface composition made after a D plasma exposure.

Nishijima, D. (ORCID:0000000231194827)↗

Investigation of pedestal parameters and divertor heat fluxes in small ELM regimes in DIII-D

Abstract Divertor heat flux and its correlation with pedestal parameters within various small edge localized mode (ELM) regimes, including high beta poloidal, type-II and ELMs with negative triangularity H-modes were investigated in DIII-D. The parallel energy fluences of type-II and high beta poloidal small ELM regimes fall below the linear scaling with pedestal electron pressure for type-I ELMs put forward in Eich et al 2017 ( Nucl. Mater. Energy 12 84–90). The negative triangularity of H-mode ELMs follow the Eich scaling for type-I ELMs. The parallel heat flux and total heat loads to the divertor were determined using high-time resolution infrared thermography, while pedestal parameters were obtained through self-consistent kinetic equilibrium reconstructions. Linear regressions for the type-II and high beta poloidal regimes demonstrate that an equivalent 7.5 MA small ELM scenario in ITER would fall below the ~5 MJ m − 2 leading edge melting limit for tungsten (Gunn et al 2017 Nucl. Fusion 57 046025). Utilizing fast thermography, the scrape-off layer power fall-off length for both inter-ELM and intra-ELM was determined and compared to the Eich scaling with poloidal magnetic field in Eich et al (ASDEX Upgrade Team and JET EFDA Contributors 2013 Nucl. Fusion 53 093031). Except for the high beta poloidal scenario, all the small ELM regimes during both inter- and intra-ELM periods had power fall-off lengths ( λ q ) larger then would be expected from the B pol , MP − 1 scaling associated with type-I ELMs, signifying their potential in managing heat loads and offering a solution for core–edge integration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutronics analysis of spin-polarized fuel in spherical tokamaks

The effect of spin-polarized deuterium–tritium fuel on the blanket, magnets, and surrounding structures is analyzed for a spherical tokamak fusion power plant. The focus of this paper is the neutron flux distribution in the fusion device and the corresponding engineering considerations, such as tritium breeding ratio (TBR) and magnet fluence. Significant benefits were found for anti-aligned polarization: a 2.7% increase in the total TBR (which could increase significantly with further optimization) and an approximately 68% increase in the magnet lifetime. If the inboard breeding blanket can be replaced with extra shielding and magnets, then it could significantly increase fusion power with no loss of magnet lifetime. This would be accomplished by increasing the toroidal field strength.

fusion↗

Radiation Effects Model for Ultra-Thin Silicon Solar Cells

This work is focused on investigation of radiation effects in Ultra-Thin Silicon solar cells with a particular emphasis on electron irradiation. The study is motivated by the application of these solar cells, developed by Solestial, Inc., for powering space missions, including those led by NASA, the Department Of Defence (DOD), and commercial satellite missions. Our research encompasses both experimental and theoretical approaches, addressing unique challenges posed by ultra-thin solar cell technology that deviates from the traditional models. From the experimental point of view, the test structures were irradiated with 1 MeV electrons up to the fluence of 1E+15 e/cm$^{2}$. Radiation effects due to accumulated electron dose were noticed as a drop in open-circuit voltage (Voc). An analytical expression for modeling the Voc characteristic of the UT-Si cell after exposure to electron irradiation was formulated and subsequently compared with experimental data. The theoretical foundation of the proposed approach builds upon the Non-Ionising Energy Loss (NIEL) concept, a fundamental parameter in addressing radiation damage modelling and survivability predictions.

Fedoseyev, Alex↗

Experimental study of different silicon sensor options for the upgrade of the CMS Outer Tracker

During the high-luminosity phase of the LHC (HL-LHC), planned to start in 2027, the accelerator is expected to deliver an instantaneous peak luminosity of up to 7.5×10 34 cm –2 s –1 . A total integrated luminosity of 3000 or even 4000 fb –1 is foreseen to be delivered to the general purpose detectors ATLAS and CMS over a decade, thereby increasing the discovery potential of the LHC experiments significantly. The CMS detector will undergo a major upgrade for the HL-LHC,with entirely new tracking detectors consisting of an Outer Tracker and Inner Tracker. However, the new tracking system will be exposed to a significantly higher radiation than the current tracker, requiring new radiation-hard sensors. CMS initiated an extensive irradiation and measurement campaign starting in 2009 to systematically compare the properties of different silicon materials and design choices for the Outer Tracker sensors. Several test structures and sensors were designed and implemented on 18 different combinations of wafer materials, thicknesses, and production technologies. The devices were electrically characterized before and after irradiation with neutrons,and with protons of different energies, with fluences corresponding to those expected at different radii of the CMS Outer Tracker after 3000 fb –1 . The tests performed include studies with β sources, lasers, and beam scans. This paper compares the performance of different options for the HL-LHC silicon sensors with a focus on silicon bulk material and thickness.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The DAQ system of the 12,000 channel CMS high granularity calorimeter prototype

The CMS experiment at the CERN LHC will be upgraded to accommodate the 5-fold increase in the instantaneous luminosity expected at the High-Luminosity LHC (HL-LHC). Concomitant with this increase will be an increase in the number of interactions in each bunch crossing and a significant increase in the total ionising dose and fluence. One part of this upgrade is the replacement of the current endcap calorimeters with a high granularity sampling calorimeter equipped with silicon sensors, designed to manage the high collision rates. As part of the development of this calorimeter, a series of beam tests have been conducted with different sampling configurations using prototype segmented silicon detectors. In the most recent of these tests, conducted in late 2018 at the CERN SPS, the performance of a prototype calorimeter equipped with ≈12,000 channels of silicon sensors was studied with beams of high-energy electrons, pions and muons. This paper describes the custom-built scalable data acquisition system that was built with readily available FPGA mezzanines and low-cost Raspberry Pi computers.

47 OTHER INSTRUMENTATION↗

Development, construction and tests of the Mu2e electromagnetic calorimeter mechanical structures

The “muon-to-electron conversion” (Mu2e) experiment at Fermilab will search for the charged lepton flavour violating neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the unambiguous evidence of the existence of physics beyond the standard model. Mu2e detectors comprise a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. In particular, the calorimeter provides excellent electron identification, a fast calorimetric online trigger, and complementary information to aid pattern recognition and track reconstruction. The detector has been designed as a state-of-the-art crystal calorimeter and employs 1348 pure Cesium Iodide (CsI) crystals readout by UV-extended silicon photosensors and fast front-end and digitization electronics. A design consisting of two identical annular matrices (named “disks”) positioned at the relative distance of 70 cm downstream the aluminum target along the muon beamline satisfies the Mu2e physics requirements. The hostile Mu2e operational conditions, in terms of radiation levels (total expected ionizing dose of 12 krad and a neutron fluence of 5 × 10$^{10}$ n/cm$^{2}$ @ 1 MeV$_{eq}$ (Si)/y), magnetic field intensity (1 T) and vacuum level (10$^{-4}$ Torr) have posed tight constraints on scintillating materials, sensors, electronics and on the design of the detector mechanical structures and material choice. The support structure of each 674 crystal matrix is composed of an aluminum hollow ring and parts made of open-cell vacuum-compatible carbon fiber. The photosensors and front-end electronics for the readout of each crystal are inserted in a machined copper holder and make a unique mechanical unit. The resulting 674 mechanical units are supported by a machined plate of vacuum-compatible plastic material. The plate also integrates the cooling system made of a network of copper lines flowing a low temperature radiation-hard fluid and placed in thermal contact with the copper holders to constitute a low resistance thermal bridge. The data acquisition electronics are hosted in aluminum custom crates positioned on the external lateral surface of the disks. The crates also integrate the electronics cooling system as lines running in parallel to the front-end system. In this paper we report on the calorimeter mechanical structure design, the mechanical and thermal simulations that have determined the design technological choices, and the status of component production, quality assurance tests and plans for assembly at Fermilab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and construction status of the Mu2e electromagnetic calorimeter mechanical structures

Abstract The Mu2e experiment at Fermilab will search for the CLFV neutrino-less coherent conversion of a muon into an electron in the field of an aluminum nucleus. The observation of this process would be the evidence of physics beyond the Standard Model. Mu2e comprises a straw-tracker, an electromagnetic calorimeter and an external veto for cosmic rays. The calorimeter provides electron identification, a fast trigger and aids track reconstruction. It is a state-of-the-art crystal calorimeter and employs 1340 pure CsI crystals readout by UV-extended SiPM and fast electronics. The design consists of two identical annular disks positioned at the relative distance of 70 cm downstream the target.The hostile Mu2e conditions (total ionizing dose of 12 krad and a neutron fluence of 5 × 10 10 n/cm 2 @ 1 MeVeq (Si)/y, 1 T magnetic field and vacuum level of 10 −4 Torr) posed tight constraints on the mechanical structures and materials choice. The support structure of the two crystal matrices employs two aluminum hollow rings and parts made of open-cell vacuum-compatible carbon fiber. SiPMs and front-end electronics for each crystal are assembled in one mechanical unit inserted in a machined copper holder. The units are supported by a plate made of vacuum-compatible material. The plate integrates the cooling system made of a network of copper lines flowing a low temperature fluid and placed in thermal contact with the copper holders. The DAQ is hosted in aluminum crates positioned on the lateral surface of the disks. The crates also integrate the DAQ electronics cooling system. We review the constraints on the calorimeter structures design, the development of all the structural components, including the simulations that have determined the materials and technological choices and the specifications of the cooling station, components production and quality assurance tests, the procedures for detector assembly, transportation and installation in the experimental area.

Instruments & Instrumentation↗

Specifications and pre-production of n + -in-p large-format strip sensors fabricated in 6-inch silicon wafers, ATLAS18, for the Inner Tracker of the ATLAS Detector for High-Luminosity Large Hadron Collider

Abstract The ATLAS experiment is constructing new all-silicon inner tracking system for HL-LHC. The strip detectors cover the radial extent of 40 to 100 cm. A new approach is adopted to use p-type silicon material, making the readout in n + -strips, so-called n + -in-p sensors. This allows for enhanced radiation tolerance against an order of magnitude higher particle fluence compared to the LHC. To cope with varying hit rates and occupancies as a function of radial distance, there are two barrel sensor types, the short strips (SS) for the inner 2 and the long strips (LS) for the outer 2 barrel cylinders, respectively. The barrel sensors exhibit a square, 9.8 × 9.8 cm 2 , geometry, the largest possible sensor area from a 6-inch wafer. The strips are laid out in parallel with a strip pitch of 75.5 μm and 4 or 2 rows of strip segments. The strips are AC-coupled and biased via polysilicon resistors. The endcap sensors employ a “stereo-annulus” geometry exhibiting a skewed-trapezoid shapes with circular edges. They are designed in 6 unique shapes, R0 to R5, corresponding to progressively increasing radial extents and which allows them to fit within the petal geometry and the 6-inch wafer maximally. The strips are in fan-out geometry with an in-built rotation angle, with a mean pitch of approximately 75 μm and 4 or 2 rows of strip segments. The eight sensor types are labeled as ATLAS18xx where xx stands for SS, LS, and R0 to R5. According to the mechanical and electrical specifications, CAD files for wafer processing were laid out, following the successful designs of prototype barrel and endcap sensors, together with a number of optimizations. A pre-production was carried out prior to the full production of the wafers. The quality of the sensors is reviewed and judged excellent through the test results carried out by vendor. These sensors are used for establishing acceptance procedures and to evaluate their performance in the ATLAS collaboration, and subsequently for pre-production of strip modules and stave and petal structures.

Instruments & Instrumentation↗

First-ever deployment of a SiPM-on-tile calorimeter in a collider: a parasitic test with 200 GeV p p collisions at RHIC.

We describe the testing of a prototype SiPM-on-tile iron-scintillator calorimeter at the Relativistic Heavy Ion Collider (RHIC) during its 200 GeV p p run in 2024. The prototype, measuring 20 × 20 cm 2 and 24 radiation lengths in depth, was positioned in the STAR experimental hall, approximately 8 m from the interaction point and 65 cm from the beam line, covering a pseudorapidity range of about 3.1 < η < 3.4. By using the dark current of a reference SiPM as a radiation monitor, we estimate that the prototype was exposed to a fluence of about 10 10 1-MeV n eq /cm 2 . Channel-by-channel calibration was performed in a data-driven way with the signature from minimum-ionizing particles during beam-on conditions. AGeant4 detector simulation, with inputs from thePythia8 event generator, describes measurements of energy spectra and hit multiplicities reasonably well. These results mark the first deployment, commissioning, calibration, and long-term operation of a SiPM-on-tile calorimeter in a collider environment. This experimental campaign will guide detector designs and operational strategies for the ePIC detector at the future EIC, as well as other applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of proton-induced damage in thick, p-channel skipper-CCDs

Here, in this work, we characterize the radiation-induced damage in two thick, p-channel skipper-CCDs irradiated unbiased and at room temperature with 217-MeV protons. We evaluate the overall performance of the sensors and demonstrate their single-electron/single-photon sensitivity after receiving a fluence on the order of 10 10 protons/cm 2 . Using the pocket-pumping technique, we quantify and characterize the proton-induced defects from displacement damage. We report an overall trap density of 0.134 traps/pixel for a displacement damage dose of 2.3 × 10 7 MeV/g. Three main proton-induced trap species were identified, V 2 , C i O i and V n O m , and their characteristic trap energies and cross sections were extracted. We found that while divacancies are the most common proton-induced defects, C i O i defects have a greater impact on charge integrity at typical operating temperatures because their emission-time constants are comparable or larger than typical readout times. To estimate ionization damage, we measure the characteristic output transistor curves. We found no threshold voltage shifts after irradiation. Our results highlight the potential of skipper-CCDs for applications requiring high-radiation tolerance and can be used to find the operating conditions in which effects of radiation-induced damage are mitigated.

47 OTHER INSTRUMENTATION↗

Application of Weak-Beam Dark-Field STEM for Dislocation Loop Analysis

Nanoscale dislocation loops formed by irradiation can significantly contribute to both irradiation hardening and embrittlement of materials when subjected to extreme nuclear reactor environments. Here, this study explores the application of weak-beam dark-field (WBDF) scanning transmission electron microscopy (STEM) methods for quantitative irradiation-induced defect analysis in crystalline materials, with a specific focus on dislocation loop imaging and analysis. A high-purity Fe-5 wt% Cr model alloy was irradiated with 8 MeV Fe 2+ ions at 450°C to a fluence of 8.8 × 10 19 m -2 , inducing dislocation loops for analysis. While transmission electron microscopy (TEM) has traditionally been the primary tool for dislocation imaging, recent advancements in STEM technology have reignited interest in using STEM for defect imaging. This study introduces and compares three WBDF STEM methods, demonstrating their effectiveness in suppressing background contrasts, isolating defect information for dislocation loop type classification, providing finer dislocation line images for small loop analysis, and presenting inside–outside contrast for identifying loop nature. Experimental findings indicate that WBDF STEM methods surpass traditional TEM approaches, yielding clearer and more detailed images of dislocation loops. The study concludes by discussing the potential applications of WBDF STEM techniques in defect analysis, emphasizing their adaptability across various material systems beyond nuclear materials.

36 MATERIALS SCIENCE↗

Specific Gamma-Ray Dose Constants with Current Emission Data

The specific gamma-ray dose constant represents the gamma effective dose rate due to a point source of unit activity of a given nuclide at 1 m. New tabulations of specific gamma-ray dose constants have been made using current gamma emission data from the SCALE 6.2.3 software package and International Commission on Radiological Protection Publication 107, combined with the effective dose per fluence conversion coefficients (antero-posterior orientation) of International Commission on Radiological Protection Publication 116. SCALE data cover 1,264 nuclides, and International Commission on Radiological Protection Publication 107 data include 1,192 nuclides, with only 777 nuclides in common between the two sets.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Shielding Analysis of a Preclinical Bremsstrahlung X-ray FLASH Radiotherapy System within a Clinical Radiation Therapy Vault

A preclinical radiotherapy system producing FLASH dose rates with 12 MV bremsstrahlung x rays is being developed at Stanford University and SLAC National Accelerator Laboratory. Because of the high expected workload of 6,800 Gy w –1 at the isocenter, an efficient shielding methodology is needed to protect operators and the public while the preclinical system is operated in a radiation therapy vault designed for 6 MV x rays. Here, in this study, an analysis is performed to assess the shielding of the local treatment head and radiation vault using the Monte Carlo code FLUKA and the empirical methodology given in the National Council on Radiation Protection and Measurements Report 151. Two different treatment head shielding designs were created to compare single-layer and multilayer shielding methodologies using high-Z and low-Z materials. The multilayered shielding methodology produced designs with a 17% reduction in neutron fluence leaking from the treatment head compared to the single layered design of the same size, resulting in a decreased effective dose to operators and the public. The conservative assumptions used in the empirical methods can lead to over-shielding when treatment heads use polyethylene or multilayered shielding. High-Z/Low-Z multilayered shielding optimized via Monte Carlo is shown to be effective in the case of treatment head shielding and provide more effective shielding design for external beam radiotherapy systems that use 12 MV bremsstrahlung photons. Modifications to empirical methods used in the assessment of MV radiotherapy systems may be warranted to capture the effects of polyethylene in treatment head shielding.

61 RADIATION PROTECTION AND DOSIMETRY↗

Excitations across the Equilibrium and Photoinduced “Hidden” States of Magnetoresistive Manganites

“Hidden” phases, generated using ultrafast laser pulses (few hundred femtoseconds), with distinct properties than at the thermodynamic equilibrium, are appealing for technologies, as they can be long-lived, with a lifetime of hours or weeks, and reversible with temperature sweeping or extra pulses. In this regard, La 2/3 ⁢Ca 1/3⁢ MnO 3 (LCMO) stands out due to its tunability through epitaxial strain, which can drive the bulk ferromagnetic metal into an antiferromagnetic insulator (AFI), and its susceptibility to photoinduced transitions. Indeed, AFI LCMO displays a long-lived photoinduced transition into a putative hidden phase whose exact nature and excitations are still largely unknown. Here, we combine ultrafast photoexcitation in the near infrared with in situ transport, x-ray absorption, and resonant inelastic x-ray scattering (RIXS) to investigate the excitations (polarons, phonons, and orbital) of the photoexcited phase of LCMO and contrast them with the thermodynamic phases achieved through strain and temperature. In the thermodynamic regime, we establish the correlation between polarons and transport placing them in the “strong coupling” regime of the Holstein model. Upon photoexcitation of LCMO-AFI, we uncover a long-lived phase characterized by the softening of the polaron excitations, the partial suppression of the Jahn-Teller distortion, and nearly unchanged phonons, showing the emergence of a photoexcited state absent in the equilibrium phase diagram. Finally, by varying temperature, epitaxial strain, and photoexcitation fluence, we construct a polaron phase diagram and identify the key spectroscopic signatures of each phase. Our laser-RIXS approach establishes a versatile platform for exploring photoinduced hidden phases in quantum materials in nonstroboscopic conditions.

36 MATERIALS SCIENCE↗