Search NASA⌕ Search

SEARCH · Search NASA

Results for “Geothermal Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Multipurpose Acoustic Sensor for Downhole Fluid Monitoring

The projects objectives and purpose are to: (1) development a multipurpose acoustic sensor for downhole fluid monitoring in Enhanced Geothermal Systems (EGS) reservoirs over typical ranges of pressures and temperatures and demonstrate its capabilities and performance for different EGS systems; (2) determine in real-time and in a single sensor package several parameters - temperature, pressure, fluid flow and fluid properties; (3) needed in nearly every phase of an EGS project, including Testing of Injection and Production Wells, Reservoir Validation, Inter-well Connectivity, Reservoir Scale Up and Reservoir Sustainability. (4) Current sensors are limited to operating at lower temperatures, but the need is for logging at high temperatures. The present project deals with the development of a novel acoustic-based sensor that can work at temperatures up to 374 °C, in inhospitable environments.

15 GEOTHERMAL ENERGY↗

The EGS Collab Project: Learnings from Experiment 1

The primary objective of the EGS Collab Project sponsored by DOE is to increase the understanding needed to efficiently implement enhanced geothermal systems (EGS). One goal of the EGS Collab project is to create a collaborative research environment in which to study stimulation of crystalline rock at the 10 meter scale. Key to this effort is the collection of high quality data to allow comparison to numerical coupled process models in an effort to build confidence in the codes and modeling techniques used. In response to this, the EGS Collab team has created an underground test bed at the Sanford Underground Research Facility (SURF) in Lead SD at a depth of approximately 1.5 km to examine hydraulic fracturing (Experiment 1). We are currently designing a second test bed aimed at investigating shear stimulation (Experiment 2). At the Experiment 1 location, we have characterized our host rock using laboratory testing and numerous field-based geophysical and geological techniques, and created a well-instrumented test bed to allow us to carefully monitor stimulation events and flow tests. In addition to the installed geophysical sensors, we have used tracer tests, differences in the ambient microbial communities at flow collection locations, and cold water injection to inform us about dynamic flow pathways. In Experiment 1, we have hydraulically stimulated the host rock in a number times at several locations in one well, creating new fractures that connect to existing fractures between the injection and production boreholes. We have performed long-term ambient and chilled water injection tests as an analog to EGS, and have monitored system changes resulting from these water injections through geophysical monitoring, flow and pressure measurements, tracer tests, and microbiology. Here, we summarize the tests performed, issues identified including poroelastic and thermoelastic effects, Joule-Thomson effects, restarting effects, indications of flow channeling, and the primary learnings from Experiment 1.

Enhanced Geothermal Systems, EGS Collab, stimulati↗

Development of a HT seismic downhole tool.

Enhanced Geothermal Systems (EGS) require the stimulation of the drilled well, likely through hydraulic fracturing. Whether fracturing of the rock occurs by shear destabilization of natural fractures or by extensional failure of weaker zones, control of the fracture process will be required to create the flow paths necessary for effective heat mining. As such, microseismic monitoring provides one method for real-time mapping of the fractures created during the hydraulic fracturing process. This monitoring is necessary to help assess stimulation effectiveness and provide the information necessary to properly create the reservoir. In addition, reservoir monitoring of the microseismic activity can provide information on reservoir performance and evolution over time. To our knowledge, no seismic tool exists that will operate above 125 C for the long monitoring durations that may be necessary. Replacing failed tools is costly and introduces potential errors such as depth variance, etc. Sandia has designed a high temperature seismic tool for long-term deployment in geothermal applications. It is capable of detecting microseismic events and operating continuously at temperatures up to 240 C. This project includes the design and fabrication of two High Temperature (HT) seismic tools that will have the capability to operate in both temporary and long-term monitoring modes. To ensure the developed tool meets industry requirements for high sampling rates (>2ksps) and high resolution (24-bit Analog-to-Digital Converter) two electronic designs will be implemented. One electronic design will utilize newly developed 200 C electronic components. The other design will use qualified Silicon-on-Insulator (SOI) devices and will have a continuous operating temperature of 240 C.

15 GEOTHERMAL ENERGY↗

Assessment of a Hybrid Continuous/Discontinuous Galerkin Finite Element Code for Geothermal Reservoir Simulations

FALCON (“Fracturing And Liquid CONvection”) is a hybrid continuous / discontinuous Galerkin finite element geothermal reservoir simulation code based on the MOOSE (“Multiphysics Object-Oriented Simulation Environment”) framework being developed and used for multiphysics applications. In the present work, a suite of verification and validation (“V&V”) test problems for FALCON was defined to meet the design requirements, and solved to the interests of enhanced geothermal system (“EGS”) design. Furthermore, the intent for this test problem suite is to provide baseline comparison data that demonstrates the performance of the FALCON solution methods. The simulation problems vary in complexity from singly mechanical or thermo process, to coupled thermo-hydro-mechanical processes in geological porous media. Numerical results obtained by FALCON agreed well with either the available analytical solution or experimental data, indicating the verified and validated implementation of these capabilities in FALCON. Some form of solution verification has been attempted to identify sensitivities in the solution methods, where possible, and suggest best practices when using the FALCON code.

15 GEOTHERMAL ENERGY↗

High-Temperature Motor Windings for Downhole Pumps Used in Geothermal Energy Production

The development of highly reliable downhole equipment is an essential element in enabling the widespread utilization of Enhanced Geothermal Systems (EGS). The downhole equipment used in these systems will be required to operate at high voltages and temperatures on the order of 200 to 250°C (and eventually to 300°C). These conditions exceed the practical operating ranges of currently available thermoplastic wire insulations, and thus limit the operating lifetime of tools such as Electric Submersible Pumps (ESPs). In this work, high-temperature insulations based on composite materials were developed and demonstrated. The products of this work were found to exhibit electrical resistivities and dielectric breakdown strengths that PEEK at temperatures above 250C. In addition, sub-scale motor windings were fabricated and tested to validate the performance of this technology

15 GEOTHERMAL ENERGY↗

SENSITIVITY OF A REACTIVE-TRACER BASED ESTIMATE OF THERMAL BREAKTHROUGH IN AN EGS TO PROPERTIES OF THE RESERVOIR AND TRACER

Reactive tracers have long been considered a possible means of measuring thermal drawdown in a geothermal system, before significant cooling occurs at the extraction well. Here, we examine the sensitivity of the proposed method to reservoir cooling and demonstrate that while the sensitivity of the method as generally proposed is low, it may be practical under certain conditions. Our analyses suggest that modifications to that method, where practical, could provide much greater sensitivity. In particular, if the reaction can be quenched before maximum temperature is reached, the sensitivity is greatly enhanced. Push-pull tracer tests conducted at the injection well demonstrate similar advantages. Other alternatives, such as combinations of tracers, and tracers with parallel or chain decay behavior may offer similar advantages.

15 GEOTHERMAL ENERGY↗

Coupled THM Modeling of Hydroshearing Stimulation in Tight Fractured Volcanic Rock

Here, we use the TOUGH-FLAC simulator for coupled thermo–hydro-mechanical modeling of well stimulation for an Enhanced Geothermal System (EGS) project. We also analyze the potential for injection-induced fracturing and reactivation of natural fractures in a porous medium with associated permeability enhancement. Our analysis aims to understand how far the EGS reservoir may grow and how the hydroshearing process relates to system conditions. We analyze the enhanced reservoir, or hydrosheared zone, by studying the extent of the failure zone using an elasto-plastic model, and accounting for permeability changes as a function of the induced stresses. For both fully saturated and unsaturated medium cases, the results demonstrate how EGS reservoir growth depends on the initial fluid phase, and how the reservoir extent changes as a function of two critical parameters: (1) the coefficient of friction, and (2) the permeability-enhancement factor. Furthermore, while well stimulation is driven by pressure exceeding the hydroshearing threshold, the modeling also demonstrates how injection-induced cooling further extends the effects of stimulation.

15 GEOTHERMAL ENERGY↗

THERMO-HYDRO-MECHANICAL MODELING OF WORKING FLUID INJECTION AND THERMAL ENERGY EXTRACTION IN EGS FRACTURES AND ROCK MATRIX

Development of enhanced geothermal systems (EGS) will require creation of a reservoir of sufficient volume to enable commercial-scale heat transfer from the reservoir rocks to the working fluid. A key assumption associated with reservoir creation/stimulation is that sufficient rock volumes can be hydraulically fractured via both tensile and shear failure, and more importantly by reactivation of naturally existing fractures (by shearing), to create the reservoir. The advancement of EGS greatly depends on our understanding of the dynamics of the intimately coupled rock-fracture-fluid-heat system and our ability to reliably predict how reservoirs behave under stimulation and production. Reliable performance predictions of EGS reservoirs require accurate and robust modeling for strongly coupled thermal-hydrological-mechanical (THM) processes. Conventionally, these types of problems have been solved using operator-splitting methods, usually by coupling a subsurface flow and heat transport simulators with a solid mechanics simulator via input files. An alternative approach is to solve the system of nonlinear partial differential equations that govern multiphase fluid flow, heat transport, and rock mechanics simultaneously, using a fully coupled, fully implicit solution procedure, in which all solution variables (pressure, enthalpy, and rock displacement fields) are solved simultaneously. This paper describes numerical simulations used to investigate the poro- and thermal- elastic effects of working fluid injection and thermal energy extraction on the properties of the fractures and rock matrix of a hypothetical EGS reservoir, using a novel simulation software FALCON (Podgorney et al., 2011), a finite element based simulator solving fully coupled multiphase fluid flow, heat transport, rock deformation, and fracturing using a global implicit approach. Investigations are also conducted on how these poro- and thermal-elastic effects are related to fracture permeability evolution.

15 GEOTHERMAL ENERGY↗

Waveguide-based ultrasonic and far-field electromagnetic sensors for downhole reservoir characterization.

This report summarizes the first year research and development effort leading to development of high-temperature sensors for enhanced geothermal systems. It covers evaluation of ultrasonic and electromagnetic (EM) techniques applied to temperature measurement and flow characterization. On temperature measurement, we have evaluated both microwave radiometry and ultrasonic techniques for temperature gradient and profile measurements. Different antenna designs are evaluated and array loop antenna design is selected for further development. We have also evaluated ultrasonic techniques for total flow characterization, which includes using speed of sound to determine flow temperature, measuring acoustic impedance to estimate fluid density, and using cross-correlation technique to determine the mass flow rate. Method to estimate the flow enthalpy is briefly discussed. At end, the need and proposed techniques to characterize the porosity and permeability of a hot dry rock resource are presented.

15 GEOTHERMAL ENERGY↗

Hydro-Mechanical Measurements of Sheared Crystalline Rock Fractures With Applications for EGS Collab Experiments 1 and 2

We present hydro-mechanical measurements that characterize shear on natural fractures in schist, amphibolite, and rhyolite specimens from the enhanced geothermal system (EGS) Collab Project's Experiment 1 and 2 sites (E1 and E2) at the Sanford Underground Research Facility. We employed a triaxial direct shear method augmented with X-ray imaging to perform hydroshearing (injection-induced shearing) and mechanical shearing on naturally fractured specimens at in situ stress conditions. Measurements included fracture permeability, strength, stress-dependent aperture, shear dilation, and frictional strength. Results reveal that in situ natural fractures must be permeable, weak, and shear-oriented to be hydrosheared, and only a subset of the observable in situ fractures were suitable. When sheared, the fracture permeability typically increased by a factor of 10 or more and this increase was retained over time. However, shear slip did not always result in permeability increase. High phyllosilicate content associated with exceptionally weak fractures exhibited poor or even decreased permeability after stimulation. These measurements in combination with site data were used to conduct a slip-tendency analysis for different fracture sets, and we selected the top candidate natural fractures for hydroshearing at the EGS Collab sites. We also found that the lower in situ shear stress and stronger fractures at the E2 site make hydroshearing more challenging than at the E1 site. Overall, the methods and analysis used in our work can be applied to any geothermal project to identify in situ joint sets that are best suited for hydroshearing, which in turn can help to optimize well placement and energy production.

58 GEOSCIENCES↗

Characterization of flow and transport in a fracture network at the EGS Collab field experiment through stochastic modeling of tracer recovery

Energy extraction from subsurface reservoirs is important for addressing the increasing energy demand and environmental concerns such as global warming. However, the characterization of subsurface reservoirs, particularly reservoirs dominated by fracture networks remains a challenge due to the lack of means to directly observe subsurface processes. This study explores the feasibility and efficacy of characterizing fracture flow and transport processes in an enhanced geothermal system (EGS) testbed through stochastic tracer modeling. There are two enabling factors that allow application of stochastic modeling to characterize a subsurface reservoir. First, an abundance of geological and geophysical measurements enables the development of a high-fidelity and well-constrained fracture network model. Second, high-performance computing (HPC) allows running massive realizations efficiently. Six conservative tracer tests were stochastically modeled and produced satisfactory realizations that successfully reproduce field tracer recovery data from each tracer test. The evolution of flow and transport processes in the fracture network was then analyzed from these satisfactory realizations. This work demonstrates that stochastic tracer modeling on a high-fidelity fracture network model is feasible and can provide important insights regarding flow and transport characteristics in subsurface fractured reservoirs.

58 GEOSCIENCES↗

Optimal design of 3D borehole seismic arrays for microearthquake monitoring in anisotropic media during stimulations in the EGS collab project

Multiple U.S. national laboratories, universities and industrial collaborators are conducting collaborative research under the EGS Collab project supported by the U.S. Department of Energy, to understand the fracture creation and imaging during fracturing in enhanced geothermal systems. Microearthquake hypocenter locations and focal mechanisms are used to monitor hydraulic fracturing growth and characterization at the EGS Collab experimental site at the Sanford Underground Research Facility using seismic receivers in multiple monitoring wells. In this study, we develop a methodology for optimal design a 3D borehole seismic array for cost-effective seismic monitoring in anisotropic media using not only the relationship between receiver distributions and standard deviation errors of microearthquake hypocenter locations, but also that between receiver distributions and focal-mechanism inversion errors. Our results indicate that microearthquake hypocenter locations and focal mechanisms can be reasonably well reconstructed for the EGS Collab Experiment I using six monitoring wells, including four fracture-parallel monitoring wells and two orthogonal wells. Lastly, eight seismic receivers evenly distributed in four parallel monitoring wells or twelve receivers in all six monitoring wells are required for hypocenter location, and twelve receivers evenly distributed in six wells or sixteen receivers in four wells are needed for focal-mechanism inversion.

58 GEOSCIENCES↗

A Methodology for Calculating EGS Electricity Generation Potential Based on the Gringarten Model for Heat Extraction From Fractured Rock

Existing methodologies for estimating the electricity generation potential of Enhanced Geothermal Systems (EGS) assume thermal recovery factors of 5% or less, resulting in relatively low volumetric electricity generation potentials for EGS reservoirs. This study proposes and develops a methodology for calculating EGS electricity generation potential based on the Gringarten conceptual model and analytical solution for heat extraction from fractured rock. The electricity generation potential of a cubic kilometer of rock as a function of temperature is calculated assuming limits on the allowed produced water temperature decline and reservoir lifetime based on surface power plant constraints. The resulting estimates of EGS electricity generation potential can be one to nearly two-orders of magnitude larger than those from existing methodologies. The flow per unit fracture surface area from the Gringarten solution is found to be a key term in describing the conceptual reservoir behavior. The methodology can be applied to aid in the design of EGS reservoirs by giving minimum reservoir volume, fracture spacing, number of fractures, and flow requirements for a target reservoir power output. Limitations of the idealized model compared to actual reservoir performance and the implications on reservoir design are discussed.

15 GEOTHERMAL ENERGY↗

Hydraulic and Thermal Stimulation Program at Raft River Idaho, A DOE EGS

A Department of Energy Enhanced Geothermal System (EGS) stimulation program has injected over 254 million gallons of water into the well RRG-9 ST1 since the summer of 2013. Three major stimulations have been conducted during the program increasing injection flow rates from less than 20 gpm to 550 gpm. Geologic, water chemistry, microseismic activity, and borehole imaging data have been used to develop a conceptual model describing possible flow paths of this injected water. This model contains two major fracture zones one of which intersects the RRG-9 ST1 wellbore. Modified Hall and injectivity index plots constructed using injection flow rates, surface temperatures, and wellhead pressures show steady improvement in the injectivity of the well. Here, the injectivity index has risen from 0.15 gpm/psi to 2.0 gpm/ psi. A pressure falloff test conducted on April 28, 2015 indicates a reservoir permeability of 1,220 md and -5.38 skin factor. The well stimulation program was simulated numerically using an Idaho National Laboratory reservoir simulation code, FALCON. These simulations show a significant increase in the permeability of connecting fracture pathways after each stimulation event.

Enhanced geothermal system↗

Newberry Seismic Deployment Fieldwork Report

This report summarizes the seismic deployment of Lawrence Livermore National Laboratory (LLNL) Geotech GS-13 short-period seismometers at the Newberry Enhanced Geothermal System (EGS) Demonstration site located in Central Oregon. This Department of Energy (DOE) demonstration project is managed by AltaRock Energy Inc. AltaRock Energy had previously deployed Geospace GS-11D geophones at the Newberry EGS Demonstration site, however the quality of the seismic data was somewhat low. The purpose of the LLNL deployment was to install more sensitive sensors which would record higher quality seismic data for use in future seismic studies, such as ambient noise correlation, matched field processing earthquake detection studies, and general EGS microearthquake studies. For the LLNL deployment, seven three-component seismic stations were installed around the proposed AltaRock Energy stimulation well. The LLNL seismic sensors were connected to AltaRock Energy Gueralp CMG-DM24 digitizers, which are powered by AltaRock Energy solar panels and batteries. The deployment took four days in two phases. In phase I, the sites were identified, a cavity approximately 3 feet deep was dug and a flat concrete pad oriented to true North was made for each site. In phase II, we installed three single component GS-13 seismometers at each site, quality controlled the data to ensure that each station was recording data properly, and filled in each cavity with native soil.

15 GEOTHERMAL ENERGY↗

Newberry EGS Demonstration: Phase 2.2 Report

The Newberry Volcano EGS Demonstration is a five year field project designed to demonstrate recent technological advances for engineered geothermal systems (EGS) development. Advances in reservoir stimulation, diverter, and monitoring are being tested in a hot (>300 ºC), dry well (NWG 55-29) drilled in 2008. In the fall of 2014, 9,500m3 (2.5 million gallons) of groundwater were injected at a maximum wellhead pressure of 195 bar (2850 psi) over 4 weeks of hydraulic stimulation. Injectivity changes, thermal profiles and seismicity indicate that fracture permeability in well NWG 55-29 was enhanced. The fifteen-station microseismic array (MSA) located 398 seismic events, ranging in magnitude from M 0 to M 2.26. The next step is to drill a production well into the EGS reservoir. Advanced analysis of the microseismic data including hand picking of first arrivals, moment tensors, relative relocations, and velocity model improvements have resulted new higher-quality microseismic catalogs. These catalogs have been combined by relative weighting and gridding of seismic densities, resulting in probability-based maps and cross-sections, which have been used to plan a production well trajectory. The microseismic locations and times were also used to develop a reservoir diffusivity model, which can be used to evaluate stimulation plans such as dual-well stimulation.

15 GEOTHERMAL ENERGY↗

3D seismic imaging of a fracture damage zone controlling reservoir compartmentalization at the Raft River EGS using multi-azimuth walkaway VSP

Accurate imaging of steeply dipping fracture zones in crystalline enhanced geothermal systems (EGS) is critical for constraining permeability architecture and guiding stimulation design. However, such structures remain poorly resolved by conventional surface seismic methods. We present a fully three-dimensional (3D) elastic-waveform inversion-migration workflow applied to multi-azimuth walkaway vertical seismic profiling (VSP) data acquired in a deviated borehole at the Raft River EGS. The workflow integrates first-arrival traveltime tomography, multi-scale elastic waveform inversion (EWI), and elastic least-squares reverse-time migration (ELSRTM) to recover high-resolution compressional-and shear-wave velocity models and to image structural discontinuities in the crystalline basement. The results reveal a laterally continuous low-velocity anomaly, with shear-wave velocity reductions of 25-30%, consistent with fractureinduced mechanical weakening. Two steeply dipping discontinuities bound a 50-80 m wide fracture damage zone. Independent constraints from microseismic clustering and geochemical compartmentalization corroborate the geometry and structural significance of this feature. Synthetic modeling further confirms that structures of this scale are resolvable (~30 m). These findings indicate that the Narrows structure is a distributed fracture damage zone rather than a discrete fault plane. By resolving fracture-zone geometry at the tens-of-meters scale using a single borehole, this workflow provides a practical and transferable approach for improving structural characterization, reducing uncertainty in permeability architecture, and supporting reservoir modeling and stimulation design in fractured crystalline EGS reservoirs.

58 GEOSCIENCES↗

Self-degradable Cementitious Sealing Materials

A self-degradable alkali-activated cementitious material consisting of a sodium silicate activator, slag, Class C fly ash, and sodium carboxymethyl cellulose (CMC) additive was formulated as one dry mix component, and we evaluated its potential in laboratory for use as a temporary sealing material for Enhanced Geothermal System (EGS) wells. The self-degradation of alkali-activated cementitious material (AACM) occurred, when AACM heated at temperatures of {ge}200 C came in contact with water. We interpreted the mechanism of this water-initiated self-degradation as resulting from the in-situ exothermic reactions between the reactants yielded from the dissolution of the non-reacted or partially reacted sodium silicate activator and the thermal degradation of the CMC. The magnitude of self-degradation depended on the CMC content; its effective content in promoting degradation was {ge}0.7%. In contrast, no self-degradation was observed from CMC-modified Class G well cement. For 200 C-autoclaved AACMs without CMC, followed by heating at temperatures up to 300 C, they had a compressive strength ranging from 5982 to 4945 psi, which is {approx}3.5-fold higher than that of the commercial Class G well cement; the initial- and final-setting times of this AACM slurry at 85 C were {approx}60 and {approx}90 min. Two well-formed crystalline hydration phases, 1.1 nm tobermorite and calcium silicate hydrate (I), were responsible for developing this excellent high compressive strength. Although CMC is an attractive, as a degradation-promoting additive, its addition to both the AACM and the Class G well cement altered some properties of original cementitious materials; among those were an extending their setting times, an increasing their porosity, and lowering their compressive strength. Nevertheless, a 0.7% CMC-modified AACM as self-degradable cementitious material displayed the following properties before its breakdown by water; {approx}120 min initial- and {approx}180 min final-setting times at 85 C, and 1825 to 1375 psi compressive strength with 51.2 to 55.0% porosity up to 300 C.

15 GEOTHERMAL ENERGY↗