Search NASA⌕ Search

SEARCH · Search NASA

Results for “Graphite”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Wear resistance and friction reduction in acrylo nitrile butadiene rubber through hybrid combination of graphite flakes and nano tungsten disulphide

Friction and wear have considerable role in the life span of two interacting parts. Incorporation of nanofillers in polymers/elastomers matrix causes commendable changes in its tribologicalproperties. The main purpose of this work is to reduce the coefficient of friction and wear rate of Acrylo Nitrile Butadiene rubber (NBR). To achieve such objective traditionally well knownlubricants graphite(G), tungsten disulphide (WS{sub 2}) and there hybrid combination was incorporated in NBR matrix. Effect of applied load (force) and concentration of fillers on tribological properties of NBR had been studied. The filler incorporation enhanced the hardnessby 8%, showed resistance to hydraulic oil and aging effect also got improved significantly. A particular optimized concentration of NBR with hybrid combination of 2% WS{sub 2} and 4% Graphite showed minimum coefficient of friction as well as wear rate. A hypothesis could be attributed that similar lamellar structure of WS{sub 2} and Graphite along with formation of a stable nanoscale disulfide tribofilmcould result in lowering of friction. These substantially improved properties of nanoreinforced rubber materials would definitely pave promising path for plethora of potential technological applications.

36 MATERIALS SCIENCE↗

Development and Performance of Tungsten-Coated Graphitic Foam for Plasma-Facing Components

High-density graphitic foam is an ideal low-Z plasma-facing material for deuterium-deuterium plasma experiments where tritium codeposition is not an issue. However, like all carbon, graphitic foam suffers from a precipitous drop in thermal conductivity at high temperatures, >600°C. To mitigate these problems, functionally graded layers of tungsten can be deposited to a thickness of 2 to 4 mm onto the plasma side of the foam using chemical vapor deposition. The graphitic foam then acts as a high-conductivity heat sink at temperatures below 600°C for the thin high-Z armor coating. The overall component weighs 18 times less than a comparable volume of tungsten and lacks the coefficient of thermal expansion joining issues between the CuCrZr tubing and the tungsten. This paper discusses the coating development and characterization and presents the results of recent plasma exposures in W7-X. It also reports on computational fluid dynamics heat transfer modeling and preparations for high heat flux testing of mock-ups. This hybrid plasma-facing component (PFC) consisting of innovative engineered materials may be a cost-effective, actively cooled solution for the divertors and other PFCs in long-pulse machines like W7-X and WEST.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ISOCHRONS IN PRESOLAR GRAPHITE GRAINS FROM ORGUEIL

Primitive meteorites contain tiny dust grains that condensed in stellar outflows and explosions. These stardust grains can be extracted from their host meteorites and studied in detail in the laboratory. We investigated depth profiles of the Al-Mg, Ca-K, and Ti-Ca isotopic systems obtained during NanoSIMS isotopic analysis of presolar graphite grains from the CI carbonaceous meteorite Orgueil. Large {sup 26}Al/{sup 27}Al, {sup 41}Ca/{sup 40}Ca, and {sup 44}Ti/{sup 48}Ti ratios, inferred from {sup 26}Mg, {sup 41}K, and {sup 44}Ca excesses from the decay of the short-lived radioisotopes {sup 26}Al, {sup 41}Ca, and {sup 44}Ti, indicate a supernova (SN) origin. From the depth distribution of the radiogenic isotopes and the stable isotopes of their parent elements we constructed isochron-type correlation plots. The plots indicate quantitative retention of radiogenic {sup 26}Mg, {sup 41}K, and {sup 44}Ca in most grains. Deviations from straight lines in the Al-Mg and Ca-K plots can be explained by contamination with {sup 27}Al and isotopically normal Ca, respectively. For the Ti-Ca system in some grains, the lack of parent-daughter correlation indicates either redistribution of radiogenic {sup 44}Ca or heterogeneity in the initial {sup 44}Ti/{sup 48}Ti ratio. We also obtained Si isotopic depth profiles in three graphite grains with large {sup 29}Si and {sup 30}Si excesses, for which a SN origin has been proposed. In two grains no Si-rich subgrains are observed; in the third grain with an apparent Si-rich subgrain the anomalous Si isotopic ratios in the subgrain are the same as in the rest of the graphite host. Our studies show that by measuring depth profiles, information on presolar grains can be obtained that cannot be obtained by whole-grain analysis.

79 ASTRONOMY AND ASTROPHYSICS↗

VACUUM ULTRAVIOLET PHOTON-STIMULATED OXIDATION OF BURIED ICE: GRAPHITE GRAIN INTERFACES

The vacuum ultraviolet (VUV) synthesis of CO and CO{sub 2} on ice-coated graphite and isotopic labeled {sup 13}C graphite has been examined for temperatures between 40 and 120 K. The results show that CO and CO{sub 2} can be formed at the buried ice:graphite interface with Lyα photon irradiation via the reaction of radicals (O and OH) produced by direct photodissociation and the dissociative electron attachment of the interfacial water molecules. The synthesized CO and CO{sub 2} molecules can desorb in hot photon-dominated regions and are lost to space when ice coated carbonaceous dust grains cycle within the protoplanetary disks. Thus, the nonthermal formation of CO and CO{sub 2} at the buried ice:grain interface by VUV photons may help regulate the carbon inventory during the early stage of planet formation. This may contribute to the carbon deficits in our solar system and suggests that a universal carbon deficit gradient may be expected within astrophysical bodies surrounding center stars.

79 ASTRONOMY AND ASTROPHYSICS↗

C, N, AND O ISOTOPIC HETEROGENEITIES IN LOW-DENSITY SUPERNOVA GRAPHITE GRAINS FROM ORGUEIL

We report on the results of NanoSIMS isotope imaging of low-density supernova graphite grains from the Orgueil meteorite. 70 nm thick microtomed sections of three supernova graphite grains were deposited on Si wafers and isotopically imaged in the NanoSIMS. These sections contain hotspots of excesses in {sup 18}O and {sup 15}N, which are spatially well correlated, and are likely carried by internal TiC subgrains. These hotspots are considerably more enriched in {sup 18}O and {sup 15}N than the host graphite grain. Correlations between {sup 18}O and {sup 15}N excesses indicate that the grains incorporated material from the He/C supernova zone. Isotope images of the surfaces of some grains show heterogeneities in their N and O isotope compositions, with extreme excesses in {sup 15}N and {sup 18}O. In the microtome sections, we also observe two types of heterogeneities in the grains' C isotopic compositions: smooth, radial gradients in {sup 12}C/{sup 13}C, with this ratio trending toward solar with increasing radius; and highly anomalous pockets up to 2 {mu}m in size with {sup 12}C/{sup 13}C >> solar that are located near the centers of the grain sections. Partial isotopic equilibration does not likely explain the C isotopic heterogeneities. These grains and their constituent parts probably formed in a stellar environment with changing isotopic composition.

79 ASTRONOMY AND ASTROPHYSICS↗

Anomalous neutron scattering `halo' observed in highly oriented pyrolytic graphite

Highly oriented pyrolytic graphite (HOPG) has been used as monochromators, analyzers and filters at neutron and X-ray scattering facilities for more than half a century. Interesting questions remain. In this work, the first observation of anomalous neutron `halo' scattering of HOPG is reported. The scattering projects a ring onto the detector with a half-cone angle of 12.4°, which surprisingly persists to incident neutron wavelengths far beyond the Bragg cutoff for graphite (6.71 Å). At longer wavelengths the ring is clearly a doublet with a splitting roughly proportional to wavelength. Sample tilting leads to the shift of the ring, which is wavelength dependent with longer wavelengths providing a smaller difference between the ring shift and the sample tilting. The ring broadens and weakens with decreasing HOPG quality. The lattice dynamics of graphite play a role in causing the scattering ring, as shown by the fact that the ring vanishes once the sample is cooled to 30 K. A possible interpretation by multiple scattering including elastic and inelastic processes is proposed.

36 MATERIALS SCIENCE↗

Development of a graphite probe calorimeter for absolute clinical dosimetry

The aim of this work is to present the numerical design optimization, construction, and experimental proof of concept of a graphite probe calorimeter (GPC) conceived for dose measurement in the clinical environment (U.S. provisional patent 61/652,540). A finite element method (FEM) based numerical heat transfer study was conducted using a commercial software package to explore the feasibility of the GPC and to optimize the shape, dimensions, and materials used in its design. A functioning prototype was constructed inhouse and used to perform dose to water measurements under a 6 MV photon beam at 400 and 1000 MU/min, in a thermally insulated water phantom. Heat loss correction factors were determined using FEM analysis while the radiation field perturbation and the graphite to water absorbed dose conversion factors were calculated using Monte Carlo simulations. The difference in the average measured dose to water for the 400 and 1000 MU/min runs using the TG-51 protocol and the GPC was 0.2% and 1.2%, respectively. Heat loss correction factors ranged from 1.001 to 1.002, while the product of the perturbation and dose conversion factors was calculated to be 1.130. The combined relative uncertainty was estimated to be 1.4%, with the largest contributors being the specific heat capacity of the graphite (type B, 0.8%) and the reproducibility, defined as the standard deviation of the mean measured dose (type A, 0.6%). By establishing the feasibility of using the GPC as a practical clinical absolute photon dosimeter, this work lays the foundation for further device enhancements, including the development of an isothermal mode of operation and an overall miniaturization, making it potentially suitable for use in small and composite radiation fields. It is anticipated that, through the incorporation of isothermal stabilization provided by temperature controllers, a subpercent overall uncertainty will be achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-AB-BRB-01: Development of a Probe-Format Graphite Calorimeter for Practical Clinical Dosimetry: Numerical Design Optimization, Prototyping, and Experimental Proof-Of-Concept

Purpose: In this work, the feasibility of performing absolute dose to water measurements using a constant temperature graphite probe calorimeter (GPC) in a clinical environment is established. Methods: A numerical design optimization study was conducted by simulating the heat transfer in the GPC resulting from irradiation using a finite element method software package. The choice of device shape, dimensions, and materials was made to minimize the heat loss in the sensitive volume of the GPC. The resulting design, which incorporates a novel aerogel-based thermal insulator, and 15 temperature sensitive resistors capable of both Joule heating and measuring temperature, was constructed in house. A software based process controller was developed to stabilize the temperatures of the GPC’s constituent graphite components to within a few 10’s of µK. This control system enables the GPC to operate in either the quasi-adiabatic or isothermal mode, two well-known, and independent calorimetry techniques. Absorbed dose to water measurements were made using these two methods under standard conditions in a 6 MV 1000 MU/min photon beam and subsequently compared against TG-51 derived values. Results: Compared to an expected dose to water of 76.9 cGy/100 MU, the average GPC-measured doses were 76.5 ± 0.5 and 76.9 ± 0.5 cGy/100 MU for the adiabatic and isothermal modes, respectively. The Monte Carlo calculated graphite to water dose conversion was 1.013, and the adiabatic heat loss correction was 1.003. With an overall uncertainty of about 1%, the most significant contributions were the specific heat capacity (type B, 0.8%) and the repeatability (type A, 0.6%). Conclusion: While the quasi-adiabatic mode of operation had been validated in previous work, this is the first time that the GPC has been successfully used isothermally. This proof-of-concept will serve as the basis for further study into the GPC’s application to small fields and MRI-linac dosimetry. This work has been supported in part by the CREATE Medical Physics Research Training Network of the Natural Sciences and Engineering Research Council (NSERC) grant 432290, NSERC grants RGPIN 298191 & 435608-13, Canadian Institutes of Health Research doctoral scholarship GSD-121793. This work has also been supported by Sun Nuclear Corporation.

60 APPLIED LIFE SCIENCES↗

Experimental and Monte Carlo studies of fluence corrections for graphite calorimetry in low- and high-energy clinical proton beams

Purpose: The aim of this study was to determine fluence corrections necessary to convert absorbed dose to graphite, measured by graphite calorimetry, to absorbed dose to water. Fluence corrections were obtained from experiments and Monte Carlo simulations in low- and high-energy proton beams. Methods: Fluence corrections were calculated to account for the difference in fluence between water and graphite at equivalent depths. Measurements were performed with narrow proton beams. Plane-parallel-plate ionization chambers with a large collecting area compared to the beam diameter were used to intercept the whole beam. High- and low-energy proton beams were provided by a scanning and double scattering delivery system, respectively. A mathematical formalism was established to relate fluence corrections derived from Monte Carlo simulations, using the FLUKA code [A. Ferrari et al., “FLUKA: A multi-particle transport code,” in CERN 2005-10, INFN/TC 05/11, SLAC-R-773 (2005) and T. T. Böhlen et al., “The FLUKA Code: Developments and challenges for high energy and medical applications,” Nucl. Data Sheets 120, 211–214 (2014)], to partial fluence corrections measured experimentally. Results: A good agreement was found between the partial fluence corrections derived by Monte Carlo simulations and those determined experimentally. For a high-energy beam of 180 MeV, the fluence corrections from Monte Carlo simulations were found to increase from 0.99 to 1.04 with depth. In the case of a low-energy beam of 60 MeV, the magnitude of fluence corrections was approximately 0.99 at all depths when calculated in the sensitive area of the chamber used in the experiments. Fluence correction calculations were also performed for a larger area and found to increase from 0.99 at the surface to 1.01 at greater depths. Conclusions: Fluence corrections obtained experimentally are partial fluence corrections because they account for differences in the primary and part of the secondary particle fluence. A correction factor, F(d), has been established to relate fluence corrections defined theoretically to partial fluence corrections derived experimentally. The findings presented here are also relevant to water and tissue-equivalent-plastic materials given their carbon content.

60 APPLIED LIFE SCIENCES↗

Investigation on the formation of lonsdaleite from graphite

Structural stability and the possible pathways to experimental formation of lonsdaleite—a hexagonal 2H polytype of diamond—have been studied in the framework of the density functional theory (DFT). It is established that the structural transformation of orthorhombic Cmmm graphite to 2H polytype of diamond must take place at a pressure of 61 GPa, while the formation of lonsdaleite from hexagonal P6/mmm graphite must take place at 56 GPa. The minimum potential barrier height separating the 2H polytype state from graphite is only 0.003 eV/atom smaller than that for the cubic diamond. The high potential barrier is indicative of the possibility of stable existence of the hexagonal diamond under normal conditions. In this work, we have also analyzed the X-ray diffraction and electron-microscopic data available for nanodiamonds found in meteorite impact craters in search for the presence of hexagonal diamond. Results of this analysis showed that pure 3C and 2H polytypes are not contained in the carbon materials of impact origin, the structure of nanocrystals found representing diamonds with randomly packed layers. The term “lonsdaleite,” used to denote carbon materials found in meteorite impact craters and diamond crystals with 2H polytype structure, is rather ambiguous, since no pure hexagonal diamond has been identified in carbon phases found at meteorite fall sites.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Ion Modification of the Field-Emission Properties of Diamond-Graphite Film Structures

The patterns of variation of structure-phase, morphological, and field-emission parameters of nanocomposite diamond-graphite film structures, which were synthesized in microwave plasma of ethanol vapors, with the dose of irradiation with nitrogen ions with an energy of 20 keV are studied. It is found that the morphological parameters of diamond-graphite structures subjected to small-dose irradiation differ only slightly from those of nonirradiated samples. In contrast, the field-emission properties of irradiated samples are altered significantly. The maximum density of field-emission currents increases when the field-emission excitation thresholds are raised. The optimum doses of nitrogen ion implantation resulting in a more than fivefold increase (relative to nonirradiated structures) in the maximum density of field-emission currents are determined. The physical and chemical mechanisms involved in the modification of surface and near-surface properties of diamond-graphite structures subjected to various doses of ion irradiation are examined.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Synthesis of Nano-Crystalline Graphite Films in Hollow Cathode Discharge

The results of experiments on the production of nano-crystalline graphite films in the hollow cathode discharge on Ni(111)/sapphire substrate are presented. The characteristics of the discharge for different gases and pressures are given. The emission spectra of the plasma have been measured. The layers of the deposited graphite have been characterized by the methods of Raman scattering and atomic force microscopy. The field emission of nano-crystalline graphite was also measured. The produced layers have good homogeneity and high value of the electron field emission. The presence of vertically growing graphene is revealed.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Apparent Increasing Lithium Diffusion Coefficient with Applied Current in Graphite

In this study, we assert that the apparent lithium diffusion coefficient in graphite active particles in the negative electrodes of lithium-ion cells increases appreciably with the intercalation rate. This assertion is based on an electrochemical model analysis of a wide range of electrochemical micro-reference electrode full cell studies on a coated natural graphite and other literature results. Although the mechanism for this increase is a subject of further investigation, the results of our study suggest that the lithium transport in the graphite does not limit the maximum attainable charging rate in typical lithium-ion cells for electric vehicles.

25 ENERGY STORAGE↗

Trapping state of hydrogen isotopes in carbon and graphite investigated by thermal desorption spectrometry

Thermal desorption spectrometry (TDS) has been investigated to obtain fundamental information of tritium behavior in graphite and carbon materials especially at high temperatures. 29 brands of graphite, HOPG, glassy carbon and CFC materials charged with deuterium gas are tested up to the temperature of 1735 K with a heating rate of 0.1 K/s. TDS spectra have five peaks at 600-700 K, around 900 K, 1200 K, 1300-1450 K and 1600-1650 K. The amounts of released deuterium have been compared with crystallographic parameters derived from XRD analysis. The results can be summarized as follows. First, TDS spectra of deuterium were quite varied among the samples tested, such as existence of peaks, peak temperatures and release amounts of deuterium. Secondly, TDS spectra may consist of five peaks, which are peak 1 (600-700 K), peak 2 (around 900 K), peak 3 (around 1200 K), peak 4 (1300-1450 K) and peak 5 (1600-1650 K). Thirdly, the correlations between the estimated surface area of edge surface and the total amount of released deuterium could be observed for peaks 4 and 5. Fourthly, high energy trapping site (peak 5) may exist even at edge surface or a near surface region, not only for intercalary. And fifth, in order to obtain the lower tritium retention for graphite and CFC materials, the material should be composed of a filler grain with a smaller crystallite size or having the smaller net edge surface in its structure. It is shown that heat treatment does not reduce originally existing trapping sites but trapping sites generated by neutron irradiation for instance can be reduced in some degree.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An investigation of fracture behaviors of NBG-18 nuclear graphite using in situ mechanical testing coupled with micro-CT

Nuclear graphite contains defects spanning from nanoscale basal cracks to sub-mm scale voids. This study aims to establish an experimental method to investigate pre-existing defects and 3-D crack growth inside nuclear graphite, NBG-18. Three-point bending tests were performed on single-edge notched beam specimens with and without coupling with micro-CT. The fracture toughness was measured to be 1.17 ± 0.06 MPa $\sqrt{{m}}$. Cracks were observed to initiate from the pores and thermal cracks on the edge of the notch and then defect or twist to grow along the pre-existing defects. Crack bridging, defection, and twisting were the primary toughening mechanisms. The crack resistance curve exhibited a trend of rising-plateau-rising that can be related to the interaction of crack front and the pre-existing defects. In conclusion, the results highlight the capability of laboratory micro-CT-based experimental method for the visualization of multi-scale defect interactions, which remains to be a challenge in the characterization of nuclear graphite.

36 MATERIALS SCIENCE↗

Modeling Stress Strain Relationships and Predicting Failure Probabilities For Graphite Core Components

This project will implement inelastic constitutive models that will yield the requisite stress-strain information necessary for graphite component design. Accurate knowledge of stress states (both elastic and inelastic) is required to assess how close a nuclear core component is to failure. Strain states are needed to assess deformations in order to ascertain serviceability issues relating to failure, e.g., whether too much shrinkage has taken place for the core to function properly. Failure probabilities, as opposed to safety factors, are required in order to capture the bariability in failure strength in tensile regimes. The current stress state is used to predict the probability of failure. Stochastic failure models will be developed that can accommodate possible material anisotropy. This work will also model material damage (i.e., degradation of mechanical properties) due to radiation exposure. The team will design tools for components fabricated from nuclear graphite. These tools must readily interact with finite element software--in particular, COMSOL, the software algorithm currently being utilized by the Idaho National Laboratory. For the eleastic response of graphite, the team will adopt anisotropic stress-strain relationships available in COMSO. Data from the literature will be utilized to characterize the appropriate elastic material constants.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Understanding Creep Mechanisms in Graphite with Experiments, Multiscale Simulations, and Modeling

Disordering mechanisms in graphite have a long history with conflicting viewpoints. Using Raman and x-ray photon spectroscopy, electron microscopy, x-ray diffraction experiments and atomistic modeling and simulations, the current project has developed a fundamental understanding of early-to-late state radiation damage mechanisms in nuclear reactor grade graphite (NBG-18 and PCEA). We show that the topological defects in graphite play an important role under neutron and ion irradiation.

36 MATERIALS SCIENCE↗

Upcycling Polyethylene Waste Into Hybrid Graphitic Porous Carbon Materials Used in High-Performance Zinc-Ion Hybrid Capacitors

Polyethylene (PE) waste is a challenge to upcycle into useful materials because this plastic tends to decompose into volatile compounds when heated at relatively low temperatures. In this work, we report a chemical process that addresses this challenge by converting mixtures of linear low-density polyethylene (LLDPE), low-density polyethylene (LDPE), and high-density polyethylene (HDPE) waste into a hybrid graphitic porous carbon (HGPC) that can be used as a zinc-ion hybrid capacitor cathode. The process uses a low temperature thermal oxidation pre-treatment step, with assistance of an inert solid additive (KCl) to increase the effective surface area of the PE melt, to functionalize, cross-link, and stabilize the PE waste followed by carbonization and catalytic graphitization steps at higher temperatures with a potassium carbonate (K2CO3) catalyst. The PE waste derived HPGC (PW-HPGC) has a hybrid structure composed of graphene-like carbon nanosheets grown on the surface of carbon particles, high porosity with the Brunauer–Emmett–Teller (BET) specific surface area up to 1,763 m2g-1, and good graphitic degree with average Raman I2D/IG ratios of 0.53. When used as a cathode material for zinc-ion hybrid capacitors, this PW-HGPC exhibits an excellent specific capacity up to 126.7 mAhg-1 at high mass loading of 10 mgcm-2. Moreover, PW-HGPC exhibits remarkable cycling stability with capacity retention of >94% after 10,000 cycles at a current density of 2.0 A g-1.

hybrid graphitic porous carbon↗