Search NASA⌕ Search

SEARCH · Search NASA

Results for “High precision control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

The AEDC aerospace chamber 7V: An advanced test capability for infrared surveillance and seeker sensors

An advanced sensor test capability is now operational at the Air Force Arnold Engineering Development Center (AEDC) for calibration and performance characterization of infrared sensors. This facility, known as the 7V, is part of a broad range of test capabilities under development at AEDC to provide complete ground test support to the sensor community for large-aperture surveillance sensors and kinetic kill interceptors. The 7V is a state-of-the-art cryo/vacuum facility providing calibration and mission simulation against space backgrounds. Key features of the facility include high-fidelity scene simulation with precision track accuracy and in-situ target monitoring, diffraction limited optical system, NIST traceable broadband and spectral radiometric calibration, outstanding jitter control, environmental systems for 20 K, high-vacuum, low-background simulation, and an advanced data acquisition system.

Simpson, W. R.↗

SU-E-J-03: Characterization of the Precision and Accuracy of a New, Preclinical, MRI-Guided Focused Ultrasound System for Image-Guided Interventions in Small-Bore, High-Field Magnets

Purpose: MRI-guided focused ultrasound (MRgFUS) has many potential and realized applications including controlled heating and localized drug delivery. The development of many of these applications requires extensive preclinical work, much of it in small animal models. The goal of this study is to characterize the spatial targeting accuracy and reproducibility of a preclinical high field MRgFUS system for thermal ablation and drug delivery applications. Methods: The RK300 (FUS Instruments, Toronto, Canada) is a motorized, 2-axis FUS positioning system suitable for small bore (72 mm), high-field MRI systems. The accuracy of the system was assessed in three ways. First, the precision of the system was assessed by sonicating regular grids of 5 mm squares on polystyrene plates and comparing the resulting focal dimples to the intended pattern, thereby assessing the reproducibility and precision of the motion control alone. Second, the targeting accuracy was assessed by imaging a polystyrene plate with randomly drilled holes and replicating the hole pattern by sonicating the observed hole locations on intact polystyrene plates and comparing the results. Third, the practicallyrealizable accuracy and precision were assessed by comparing the locations of transcranial, FUS-induced blood-brain-barrier disruption (BBBD) (observed through Gadolinium enhancement) to the intended targets in a retrospective analysis of animals sonicated for other experiments. Results: The evenly-spaced grids indicated that the precision was 0.11 +/− 0.05 mm. When image-guidance was included by targeting random locations, the accuracy was 0.5 +/− 0.2 mm. The effective accuracy in the four rodent brains assessed was 0.8 +/− 0.6 mm. In all cases, the error appeared normally distributed (p<0.05) in both orthogonal axes, though the left/right error was systematically greater than the superior/inferior error. Conclusions: The targeting accuracy of this device is sub-millimeter, suitable for many preclinical applications including focused drug delivery and thermal therapy. Funding support provided by Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

Hierarchical control of porous silica by pH adjustment: Alkyl polyamines as surfactants for bimodal silica synthesis and its carbon replica

Bimodal macro-mesoporous silica networks have been prepared in a simple one-pot synthesis using an inexpensive tetramine surfactant and tetraethoxysilane as a silica precursor. These novel materials show high pore volumes and templated mesopores (average pore size 3.0 nm) embedded in 20 nm thick walls forming interparticle large meso/macropores. The judicious control of the pH during the silica formation allows for the precise control of the interparticle condensation, likely due to the change in the interaction between the tetramine surfactant and the silica precursors. Finally, a highly porous carbon replica with bimodal porosity was prepared by using the bimodal silica as a hard sacrificial template. The microstructure of the silica template was accurately transferred to the carbon material obtaining high surface areas (up to 1300 m{sup 2} g{sup -1}) and total pore volumes >=2 cm{sup 3} g{sup -1}. - Graphical abstract: Hierarchical bimodal porous silica and its carbon replica prepared by nanocasting.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The Maturing of High Contrast Imaging and Starlight Suppression Techniques for Future NASA Exoplanet Characterization Missions

Over 3000 exoplanets and hundreds of exoplanetary systems have been detected to date and we are now rapidly moving toward an era where the focus is shifting from detection to direct imaging and spectroscopic characterization of these new worlds and their atmospheres. NASA is currently studying several exoplanet characterization mission concepts for the 2020 Decadal Survey ranging from probe class to flagships. Detailed and comprehensive exoplanet characterization, particularly of exo-Earths, leading to assessment of habitability, or indeed detection of life, will require significant advances beyond the current state-of-the-art in high contrast imaging and starlight suppression techniques which utilize specially shaped precision optical elements to block the light from the parent star while controlling scattering and diffraction thus revealing and enabling spectroscopic study of the orbiting exoplanets in reflected light. In this paper we describe the two primary high contrast starlight suppression techniques currently being pursued by NASA: 1) coronagraphs (including several design variations) and 2) free-flying starshades. These techniques are rapidly moving from the technology development phase to the design and engineering phase and we discuss the prospects and projected performance for future exoplanet characterization missions utilizing these techniques coupled with large aperture telescopes in space.

high contrast↗

Tailoring the Near-Surface Environment of Rh Single-Atom Catalysts for Selective CO 2 Hydrogenation

For this study, we used a combination of experimental spectroscopies, density functional theory calculations, and CO 2 hydrogenation studies to investigate the effects of modifying single-atom Rh 1 /TiO 2 catalysts with functionalized phosphonic acid monolayers. We found that the deposition of specific amine-functionalized ligands resulted in an ~8× increase in site-specific CO 2 reduction turnover frequency at 150 °C and a ~2× increase at 250 °C. On-stream stability also improved following ligand deposition. The effect of the modifier on reactivity was highly sensitive to the proximity of the amine functional group to the surface, which was controlled by adjusting the length of the phosphonic acid tail. Furthermore, deposition of alkyl phosphonic acids without an amine functional group resulted in blocked CO 2 adsorption and a near-complete loss of catalytic activity. Infrared spectroscopy studies suggested that the amine group provided binding sites for CO 2 that enabled hydrogenation when the amine was positioned near a Rh1 site. Phosphonic acid-modified catalysts also exhibited high selectivity to CO over the series product methane; the selectivity effect was traced to modification of the Rh1 sites to favor CO desorption. Phosphonic acid deposition resulted in 80–90% loss of accessible Rh1 sites, likely due to blocking by tail groups. However, even with the loss of sites, under low-temperature reaction conditions, the rates of CO 2 hydrogenation were improved with the coatings, indicating that the remaining sites are highly efficient. Organic functionalization of the supports for atomically dispersed catalysts offers the opportunity to precisely control the positioning of functional groups in the vicinity of a well-defined active site, potentially enabling an additional level of control over active site design.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Surface Impedance of Superconducting Radio Frequency (SRF) Materials

Superconducting radio frequency (SRF) technology is widely adopted in particle accelerators. There remain many open questions, however, in developing a systematic understanding of the fundamental behavior of SRF materials, including niobium treated in different ways and various other bulk/thin film materials that are fabricated with different methods under assorted conditions. A facility that can measure the SRF properties of small samples in a range of 2-40 K temperature is needed in order to fully answer these questions. The Jefferson Lab surface impedance characterization (SIC) system has been designed to attempt to meet this requirement. It consists of a sapphire-loaded cylindrical Nb TE011 cavity at 7.4 GHz with a 50 mm diameter flat sample placed on a non-contacting end plate and uses a calorimetric technique to measure the radio frequency (RF) induced heat on the sample. Driving the resonance to a known field on this surface enables one to derive the surface resistance of a relatively small localized area. TEo11 mode identification has been done at room temperature and 4 K, and has been compared with Microwave Studio® and SuperFish simulation results. RF loss mechanisms in the SIC system are under investigation. A VCO phase lock loop system has been used in both CW and pulsed mode. Two calorimeters, with stainless steel and Cu as the thermal path material for high precision and high power versions, respectively, have been designed and commissioned for the SIC system to provide low temperature control and measurement. A power compensation method has been developed to measure the RF induced power on the sample. Simulation and experimental results show that with these two calorimeters, the whole thermal range of interest for SRF materials has been covered. The power measurement error in the interested power range is within 1.2% and 2.7% for the high precision and high power versions, respectively. Temperature distributions on the sample surface for both versions have been simulated and the accuracy of sample temperature measurements have been analysed. Both versions have the ability to accept bulk superconductors and thin film superconducting samples with a variety of substrate materials such as AI, Al20 3 , Cu, MgO, Nb and Si. Tests with polycrystalline and large grain bulk Nb samples have been done at <15 mT magnetic field. Based on BCS surface impedance, least-squares fittings have been done using SuperFit2.0, a code developed by G. Ciovati and the author. Microstructure analyses and SRF measurements of large scale epitaxial MgB2 films have been reported. MgB2 films on 5 em dia. sapphire disks were fabricated by a Hybrid Physical Chemical Vapor Deposition (HPCVD) technique. The electron-beam backscattering diffraction (EBSD) results suggest that the film is a single crystal complying with a MgB2(0001 )//AI203(0001) epitaxial relationship. The SRF properties of different film thicknesses (200 nm and 350 nm) were evaluated using SIC system under different temperatures and applied fields at 7.4 GHz. A surface resistance of 9±2 1-10 has been observed at 2.2 K. Based on BCS theory with moving Cooper pairs, the electron states distribution at OK and the probability of electron occupation with finite temperature have been derived and applied to anomalous skin effect theory to obtain the surface impedance of a superconductor with moving Cooper pairs. We present the numerical results for Nb.

Xiao, Binping↗

Chapter 12: High-Efficiency Water Splitting Systems

In this chapter, we discuss the prerequisites for high-efficiency water splitting and their implementation with tandem cells based on absorbers of the III-V semiconductor material class. A brief outline of efficiency-limiting factors shows that at a given set of boundary conditions, such as catalyst performance, the optimum tandem absorbers require a very precise control of opto-electronic properties, as facilitated by the III-V compounds. After a short history of high efficiency solar energy conversion, we present recent implementations of highly efficient water splitting systems with solar-to-hydrogen efficiencies of 14-16% together with an outlook on further improvements. Even if other absorber systems turn out to be more cost-competitive, the III-V systems currently serve as a testbed for high-efficiency water splitting in general, with lessons to be learned for catalyst requirements, cell design, and efficiency validation. We conclude with a discussion of appropriate efficiency benchmarking routines, outlining potential pitfalls for multi-junction absorbers and how to avoid them.

36 MATERIALS SCIENCE↗

Actuated Hybrid Mirror Telescope

The figure depicts the planned Actuated Hybrid Mirror Telescope (AHMT), which is intended to demonstrate a new approach to the design and construction of wide-aperture spaceborne telescopes for astronomy and Earth science. This technology is also appropriate for Earth-based telescopes. The new approach can be broadly summarized as using advanced lightweight mirrors that can be manufactured rapidly at relatively low cost. More specifically, it is planned to use precise replicated metallic nanolaminate mirrors to obtain the required high-quality optical finishes. Lightweight, dimensionally stable silicon carbide (SiC) structures will support the nanolaminate mirrors in the required surface figures. To enable diffraction- limited telescope performance, errors in surface figures will be corrected by use of mirror-shape-control actuators that will be energized, as needed, by a wave-front-sensing and control system. The concepts of nanolaminate materials and mirrors made from nanolaminate materials were discussed in several previous NASA Tech Briefs articles. Nanolaminates constitute a relatively new class of materials that can approach theoretical limits of stiffness and strength. Nanolaminate mirrors are synthesized by magnetron sputter deposition of metallic alloys and/or compounds on optically precise master surfaces to obtain optical-quality reflector surfaces backed by thin shell structures. As an integral part of the deposition process, a layer of gold that will constitute the reflective surface layer is deposited first, eliminating the need for a subsequent and separate reflective-coating process. The crystallographic textures of the nanolaminate will be controlled to optimize the performance of the mirror. The entire deposition process for making a nanolaminate mirror takes less than 100 hours, regardless of the mirror diameter. Each nanolaminate mirror will be bonded to its lightweight SiC supporting structure. The lightweight nanolaminate mirrors and SiC supporting structures will be fabricated from reusable master molds. The mirror-shape-control actuators will be low-power, high-capacitance lead magnesium niobate electrostrictive actuators that will be embedded in the SiC structures. The mode of operation of these actuators will be such that once power was applied, they will change in length and once power was removed, they will maintain dimensional stability to nanometer precision. This mode of operation will enable the use of low-power, minimally complex electronic control circuitry. The wave-front-sensing and control system will be designed and built according to a two-stage architecture. The first stage will be implemented by a Shack- Hartmann (SH) sensor subsystem, which will provide a large capture range. The second, higher-performance stage will be implemented by an image-based wave-front-sensing subsystem that will include a phase-retrieval camera (PRC), and will utilize phase retrieval and other techniques to measure wavefront error directly. Phase retrieval is a process in which multiple images of an unresolved object are iterated to estimate the phase of the optical system that acquired the images. The combination of SH and phase-retrieval sensors will afford the virtues of both a dynamic range of 105 and an accuracy of <10 nm.

Hickey, Gregory↗

Mitigation of the Impact of Sensing Noise on the Precise Formation Flying Control Problem

The specific objectives of this proposed research were: 1. Further investigation into the impact of CDGPS sensing errors for high Earth orbit missions. 2. Identify augmentation approaches of the CDGPS that will improve the relative state for low and high Earth orbit missions. 3. Integration of the navigation and control concepts into the GSFC Formation Flying Testbed. In addition this was a cooperative effort with Dr. Jonathan How at MIT. Dr. Alfriend was to spend two weeks working with Dr. How and his students. The travel for these two weeks was paid by the Texas Engineering Experiment Station (TEES) as cost sharing.

Alfriend, K. T.↗

Evolution of Electronic Properties of Graphene Nanoribbons with Progressive Carving: From Straight to Porous to Chevron Ribbons

Graphene nanoribbons (GNRs) are highly versatile materials due to their unique electronic, magnetic, and optical properties, which can be precisely tuned by controlling their width, edge structure, and topology. Here, we report the on-surface synthesis and characterization of a straight N = 15 armchair GNR with periodic annulene nanopores (15-pGNR). It serves as a structural link between two well-established GNRs: the pristine N = 15 armchair GNR without pores (15-AGNR) and the chevron GNR (cGNR). With the addition of the 15-pGNR reported in this study, these three GNRs form a rare experimentally accessible series of ribbons, in which the evolution of electronic properties can be tracked upon progressive carving of a basic 15-AGNR: first, by creating periodic nanopores to form 15-pGNR and then by extending the pore area and producing meandering cGNR. We have designed a molecular precursor for the 15-pGNR and grown the nanoribbons on single-crystal gold substrates by on-surface synthesis in ultra-high vacuum (UHV) conditions. The atomically precise structure of 15-pGNR was confirmed by scanning tunneling microscopy (STM) and non-contact atomic force microscopy (nc-AFM). The band gap of 15-pGNR was studied by scanning tunneling spectroscopy (STS) and dI/dV mapping, and the occupied electronic levels were investigated by angle-resolved photoemission spectroscopy (ARPES). A theoretical and experimental comparison of 15-pGNRs, 15-AGNRs, and cGNRs demonstrates that the introduction of periodic nanopores into 15-AGNR leads to a more than 2-fold increase in its band gap. In contrast, the band gaps of 15-pGNR and cGNR differ only by about 15%. Such band gap increase can be qualitatively understood to arise from two combined effects, the periodic perforation of the graphene lattice and the confinement effect induced by the GNR width.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Accurately constituting robust interfaces for high-performance high-energy lithium metal batteries

High-energy lithium metal batteries (LMBs) have received ever-increasing interest. Among them, coupling lithium metal (Li) with nickel-rich material, LiNi x Mn y Co z O 2 (NMCs, x ≥ 0.6, x + y + z = 1), is promising because Li anodes enable an extremely high capacity (∼3860 mA h g −1 ) and the lowest redox potential (−3.04 V vs. standard hydrogen electrode), while NMCs can achieve a much higher capacity of ∼200 mA h g −1 and lower cost than those of LiCoO 2 . However, the resultant Li‖NMC cells have been hindered from commercialization due to a series of challenges related to the interface stability of both Li anodes and NMC cathodes. Specifically, Li anodes suffer from Li dendritic growth and the formation of solid electrolyte interphase (SEI), while NMC cathodes suffer from the formation of cathode electrolyte interphase (CEI) and other interface-related issues, including transition metal dissolution, oxygen release, cracking, and so on. To tackle these issues, recently, two sister techniques, atomic and molecular layer deposition (ALD and MLD), have emerged and exhibit tremendous capabilities to accurately constitute robust interfaces to achieve high-performance Li‖NMC LMBs. They can uniquely develop uniform and conformal films as surface coatings of LMBs in a precisely controllable mode at the atomic/molecular level, while proceeding with film deposition at low temperatures (e.g., ≤250 °C). In this Feature Article, we review the latest research progress in developing novel surface coatings via ALD and MLD for Li‖NMC LMBs and discuss outcomes for pursuing high performance.

25 ENERGY STORAGE↗

Using image area to control CCD systematic errors in spaceborne photometric and astrometric time-series measurements

The effect of some systematic errors for high-precision time-series spaceborne photometry and astrometry has been investigated with a CCD as the detector. The 'pixelization' of the images causes systematic error in astrometric measurements. It is shown that this pixelization noise scales as image radius r exp -3/2. Subpixel response gradients, not correctable by the 'flat field', and in conjunction with telescope pointing jitter, introduce further photometric and astrometric errors. Subpixel gradients are modeled using observed properties of real flat fields. These errors can be controlled by having an image span enough pixels. Large images are also favored by CCD dynamic range considerations. However, magnified stellar images can overlap, thus introducing another source of systematic error. An optimum image size is therefore a compromise between these competing factors.

Buffington, Andrew↗

Shape control of high degree-of-freedom variable geometry trusses

Common static trusses are constrained to permit no relative motion between truss elements. A Variable Geometry Truss (VGT), however, is a truss which contains some number of variable length links. The extensible links allow the truss to change shape in a precise, controllable manner. These changes can also be used to control the vibrational response of a truss structure or to perform robotic tasks. Many geometric configurations, both planar and spatial, are possible candidates for VGT manipulators. Here, only two geometries are discussed; the three degree-of-freedom (DOF) spatial octahedral/octahedral truss and the three DOF planar tetrahedral truss. These truss geometries are used as the fundamental element in a repeating chain of trusses. This results in a highly dexterous manipulator with perhaps 30 to 60 degrees of freedom that retains the favorable stiffness properties of a conventional truss. From a fixed base, this type of manipulator could perform shape or vibration control while extending and snaking through complex passageways or moving around obstacles to perform robotic tasks. The approach taken here is to first concentrate on fully understanding the forward and inverse kinematics of the fundamental elements and then utilizing the insight thus gained to solve the more complex problem of the kinematic chains.

Salerno, R. J.↗

In Situ Apparatus to Study Gas–Metal Reactions and Wettability at High Temperatures for Hot-Dip Galvanizing Applications

The understanding of gas–metal reactions and related surface wettability at high temperatures is often limited due to the lack of in situ surface characterization. Ex situ transfers at low temperature between annealing furnace, wettability device, and analytical tools induce noticeable changes of surface composition distinct from the reality of the phenomena.Therefore, a high temperature wettability device was designed in order to allow in situ sample surface characterization by x-rays photoelectron spectroscopy after gas/metal and liquid metal/solid metal surface reactions. Such airless characterization rules out any contamination and oxidation of surfaces and reveals their real composition after heat treatment and chemical reaction. The device consists of two connected reactors, respectively, dedicated to annealing treatments and wettability measurements. Heat treatments are performed in an infrared lamp furnace in a well-controlled atmosphere conditions designed to reproduce gas–metal reactions occurring during the industrial recrystallization annealing of steels. Wetting experiments are carried out in dispensed drop configuration with the precise control of the deposited droplets kinetic energies. The spreading of drops is followed by a high-speed CCD video camera at 500-2000 frames/s in order to reach information at very low contact time. First trials have started to simulate phenomena occurring during recrystallization annealing and hot-dip galvanizing on polished pure Fe and FeAl8 wt.% samples. The results demonstrate real surface chemistry of steel samples after annealing when they are put in contact with liquid zinc alloy bath during hot-dip galvanizing. The wetting results are compared to literature data and coupled with the characterization of interfacial layers by FEG-Auger. It is fair to conclude that the results show the real interest of such in situ experimental setup for interfacial chemistry studies.

36 MATERIALS SCIENCE↗

Clinical Ion Beam Applications: Basic Properties, Application, Quality Control, Planning

Heavy-ion therapy using beam scanning and biological dose optimization is a novel technique of high-precision external radiotherapy. It yields a better perspective for tumor cure of radio-resistant tumors. However, heavy-ion therapy is not a general solution for all types of tumors. As compared to conventional radiotherapy, heavy-ion radiotherapy has the advantages of higher tumor dose, improved sparing of normal tissue in the entrance channel, a more precise concentration of the dose in the target volume with steeper gradients to the normal tissue, and a higher radiobiological effectiveness for tumors which are radio-resistant in conventional therapy. These properties make it possible to treat radio-resistant tumors with great success, including those in close vicinity to critical organs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ultrafast method for scanning tunneling spectroscopy

A scanning tunneling microscope (STM) combines unique capabilities in imaging and spectroscopy with atomic precision, and it can obtain energy-resolved spectroscopic data with atomic resolution. In this paper, we utilize a recently proposed modification to the STM feedback control loop to acquire high quality d 2 I/dV 2 images. We have developed a constant differential conductance imaging method by closing the STM feedback loop with a high precision dI/dV measurement. In this mode, the tip’s vertical position is adjusted so as to keep the differential conductance constant during raster scanning of the surface. Based on this imaging mode, we propose a new technique to acquire fast and reliable scanning tunneling spectroscopy (STS) data simultaneously with the imaging.

47 OTHER INSTRUMENTATION↗

Study of flywheel energy storage for space stations

The potential of flywheel systems for space stations using the Space Operations Center (SOC) as a point of reference is discussed. Comparisons with batteries and regenerative fuel cells are made. In the flywheel energy storage concept, energy is stored in the form of rotational kinetic energy using a spinning wheel. Energy is extracted from the flywheel using an attached electrical generator; energy is provided to spin the flywheel by a motor, which operates during sunlight using solar array power. The motor and the generator may or may not be the same device. Flywheel energy storage systems have a very good potential for use in space stations. This system can be superior to alkaline secondary batteries and regenerable fuel cells in most of the areas that are important in spacecraft applications. Of special impotance relative to batteries, are high energy density (lighter weight), longer cycle and operating life, and high efficiency which minimizes the amount of orbital makeup fuel required. In addition, flywheel systems have a long shelf life, give a precise state of charge indication, have modest thermal control needs, are capable of multiple discharges per orbit, have simple ground handling needs, and have the potential for very high discharge rate. Major disadvantages are noted.

Gross, S.↗

Feedstock design for quality biomaterials

Feedstock design is crucial for lignocellulosic biomass use. Current strategies for feedstock design cannot be readily applied to improve the quality of biomass-based materials, limiting the sustainability and economics of lignocellulosic biorefineries. Recent studies have advanced the understanding of biomass structure–property relationships and discovered several characteristics, such as molecular weight, uniformity, linkage profile, and functional groups, that are critical for manufacturing diverse quality biomaterials. Further, these discoveries call for fundamentally different strategies for feedstock development. Such strategies need to rediscover the roles of monolignol biosynthesis enzymes and leverage lignin polymerization enzymes to achieve precise control of lignin molecular structure. These innovations could transform biomass into feedstock for high-quality biomaterials, addressing essential environmental challenges and empowering the bioeconomy.

09 BIOMASS FUELS↗