Search NASA⌕ Search

SEARCH · Search NASA

Results for “High spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

A study of dynamical processes in the Orion KL region using ALMA—probing molecular outflow and inflow

This work reports high spatial resolution observations toward the Orion KL region with high critical density lines of CH{sub 3}CN (12{sub 4}-11{sub 4}) and CH{sub 3}OH (8{sub –1,8}-7{sub 0,7}), as well as a continuum at ∼1.3 mm band. The observations were made using the Atacama Large Millimeter/Submillimeter Array with a spatial resolution of ∼1.''5 and sensitivity of about 0.07 K and ∼0.18 K for continuum and line, respectively. The observational results showed that the gas in the Orion KL region consists of jet-propelled cores at the ridge and dense cores east and south of the region that are shaped like a wedge ring. The outflow has multiple lobes, which may originate from an explosive ejection, and is not driven by young stellar objects. Four infrared bubbles were found in the Spitzer/IRAC emissions. These bubbles, the distributions of the previously found H{sub 2} jets, the young stellar objects, and molecular gas suggest that BN is the explosive center. The burst time was estimated to be ≤1300 yr. At the same time, signatures of gravitational collapse toward Source I and the hot core were detected with material infall velocities of 1.5 km s{sup –1} and ∼0.6 km s{sup –1}, corresponding to mass accretion rates of 1.2 × 10{sup –3} M {sub ☉}/yr and 8.0 × 10{sup –5} M {sub ☉}/yr, respectively. These observations may support the belief that high-mass stars form via the accretion model, similar to their low-mass counterparts.

79 ASTRONOMY AND ASTROPHYSICS↗

A global coupled Eulerian-Lagrangian model and 1 1 km CO2 surface flux dataset for high-resolution atmospheric CO2 transport simulations

Abstract. We designed a method to simulate atmospheric CO2 concentrations at several continuous observation sites around the globe using surface fluxes at a very high spatial resolution. The simulations presented in this study were performed using the Global Eulerian-Lagrangian Coupled Atmospheric model (GELCA), comprising a Lagrangian particle dispersion model coupled to a global atmospheric tracer transport model with prescribed global surface CO2 flux maps at a 1 1 km resolution. The surface fluxes used in the simulations were prepared by assembling the individual components of terrestrial, oceanic and fossil fuel CO2 fluxes. This experimental setup (i.e. a transport model running at a medium resolution, coupled to a high-resolution Lagrangian particle dispersion model together with global surface fluxes at a very high resolution), which was designed to represent high-frequency variations in atmospheric CO2 concentration, has not been reported at a global scale previously. Two sensitivity experiments were performed: (a) using the global transport model without coupling to the Lagrangian dispersion model, and (b) using the coupled model with a reduced resolution of surface fluxes, in order to evaluate the performance of Eulerian-Lagrangian coupling and the role of high-resolution fluxes in simulating high-frequency variations in atmospheric CO2 concentrations. A correlation analysis between observed and simulated atmospheric CO2 concentrations at selected locations revealed that the inclusion of both Eulerian-Lagrangian coupling and highresolution fluxes improves the high-frequency simulations of the model. The results highlight the potential of a coupled Eulerian-Lagrangian model in simulating high-frequency atmospheric CO2 concentrations at many locations worldwide. The model performs well in representing observations of atmospheric CO2 concentrations at high spatial and temporal resolutions, especially for coastal sites and sites located close to sources of large anthropogenic emissions. While this study focused on simulations of CO2 concentrations, the model could be used for other atmospheric compounds with known estimated emissions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Flexible, foldable, actively multiplexed, high-density electrode array for mapping brain activity in vivo

Arrays of electrodes for recording and stimulating the brain are used throughout clinical medicine and basic neuroscience research, yet are unable to sample large areas of the brain while maintaining high spatial resolution because of the need to individually wire each passive sensor at the electrode-tissue interface. To overcome this constraint, we developed new devices that integrate ultrathin and flexible silicon nanomembrane transistors into the electrode array, enabling new dense arrays of thousands of amplified and multiplexed sensors that are connected using fewer wires. We used this system to record spatial properties of cat brain activity in vivo, including sleep spindles, single-trial visual evoked responses and electrographic seizures. We found that seizures may manifest as recurrent spiral waves that propagate in the neocortex. As a result, the developments reported here herald a new generation of diagnostic and therapeutic brain-machine interface devices.

high spatial resolution↗

MagicPlate-512: A 2D silicon detector array for quality assurance of stereotactic motion adaptive radiotherapy

Purpose: Spatial and temporal resolutions are two of the most important features for quality assurance instrumentation of motion adaptive radiotherapy modalities. The goal of this work is to characterize the performance of the 2D high spatial resolution monolithic silicon diode array named “MagicPlate-512” for quality assurance of stereotactic body radiation therapy (SBRT) and stereotactic radiosurgery (SRS) combined with a dynamic multileaf collimator (MLC) tracking technique for motion compensation. Methods: MagicPlate-512 is used in combination with the movable platform HexaMotion and a research version of radiofrequency tracking system Calypso driving MLC tracking software. The authors reconstruct 2D dose distributions of small field square beams in three modalities: in static conditions, mimicking the temporal movement pattern of a lung tumor and tracking the moving target while the MLC compensates almost instantaneously for the tumor displacement. Use of Calypso in combination with MagicPlate-512 requires a proper radiofrequency interference shielding. Impact of the shielding on dosimetry has been simulated by GEANT4 and verified experimentally. Temporal and spatial resolutions of the dosimetry system allow also for accurate verification of segments of complex stereotactic radiotherapy plans with identification of the instant and location where a certain dose is delivered. This feature allows for retrospective temporal reconstruction of the delivery process and easy identification of error in the tracking or the multileaf collimator driving systems. A sliding MLC wedge combined with the lung motion pattern has been measured. The ability of the MagicPlate-512 (MP512) in 2D dose mapping in all three modes of operation was benchmarked by EBT3 film. Results: Full width at half maximum and penumbra of the moving and stationary dose profiles measured by EBT3 film and MagicPlate-512 confirm that motion has a significant impact on the dose distribution. Motion, no motion, and motion with MLC tracking profiles agreed within 1 and 0.4 mm, respectively, for all field sizes tested. Use of electromagnetic tracking system generates a fluctuation of the detector baseline up to 10% of the full scale signal requiring a proper shielding strategy. MagicPlate-512 is also able to reconstruct the dose variation pulse-by-pulse in each pixel of the detector. An analysis of the dose transients with motion and motion with tracking shows that the tracking feedback algorithm used for this experiment can compensate effectively only the effect of the slower transient components. The fast changing components of the organ motion can contribute only to discrepancy of the order of 15% in penumbral region while the slower components can change the dose profile up to 75% of the expected dose. Conclusions: MagicPlate-512 is shown to be, potentially, a valid alternative to film or 2D ionizing chambers for quality assurance dosimetry in SRS or SBRT. Its high spatial and temporal resolutions allow for accurate reconstruction of the profile in any conditions with motion and with tracking of the motion. It shows excellent performance to reconstruct the dose deposition in real time or retrospectively as a function of time for detailed analysis of the effect of motion in a specific pixel or area of interest.

60 APPLIED LIFE SCIENCES↗

A Method for Obtaining High Time and Spatial Resolution Convective Cloud Top Data for the TTL

A method for obtaining high time and spatial resolution convective cloud top data for the TTL Leonhard Pfister, Eric Jensen, Rei Ueyama, Eliot Atlas, and Maria Navarro Convective systems in the tropics have a maximum in the cloud top altitude distribution of about 13.5 km. However, there is a significant tail to this distribution -- a few percent reach the cold point tropopause (CPT) at 16.5 km, and there has been clear evidence of convective mass deposited as high as 19 km in the tropics. The region between 13.5 km and the cold point tropopause is transitional, between the free tropical troposphere where convective mixing dominates, and the stratosphere where slow upward ascent dominates. In this region (the Tropical Tropopause Layer), convective injection, slow ascent, and mixing from midlatitudes all have similar time scales. So, even though only a few percent of convective systems reach the CPT, convection is important. Space Based Lidar and cloud radar measurements have yielded information about long term average statistical distributions of cloud altitude as a function of location. However, we also need time-dependent cloud top altitude and cloud top potential temperature information, primarily to understand the water vapor and TTL cloud distributions. This is because the effect of convection depends on the local temperature, and on the subsequent temperature history. Time dependent cloud top information is also needed to understand short-lived tracers because cross-isentropic flow is time and space dependent. This paper presents a method of obtaining time and space dependent convective cloud top theta (and altitude) information using 3-hourly geostationary brightness temperature data, coupled with global 3 -hourly rainfall estimates and temperature analyses. We explore different mixing algorithms to obtain the most reasonable agreement with near-simultaneous observations by cloudsat and calipso. Observations of short-lived tracers from ATTREX, coupled with short-term trajectories are used to test the method's accuracy. An important caveat is the ambiguity of evaluating convective cloud top altitudes under from combined cloudsat and calipso measurements.

cold point tropopause (CPT)↗

SU-F-I-38: Patient Organ Specific Dose Assessment in Coronary CT Angiograph Using Voxellaized Volume Dose Index in Monte Carlo Simulation

Purpose: Clinical use of multi detector computed tomography(MDCT) in diagnosis of diseases due to high speed in data acquisition and high spatial resolution is significantly increased. Regarding to the high radiation dose in CT and necessity of patient specific radiation risk assessment, the adoption of new method in the calculation of organ dose is completely required and necessary. In this study by introducing a conversion factor, patient organ dose in thorax region based on CT image data using MC system was calculated. Methods: The geometry of x-ray tube, inherent filter, bow tie filter and collimator were designed using EGSnrc/BEAMnrc MC-system component modules according to GE-Light-speed 64-slices CT-scanner geometry. CT-scan image of patient thorax as a specific phantom was voxellised with 6.25mm3 in voxel and 64×64×20 matrix size. Dose to thorax organ include esophagus, lung, heart, breast, ribs, muscle, spine, spinal cord with imaging technical condition of prospectively-gated-coronary CT-Angiography(PGT) as a step and shoot method, were calculated. Irradiation of patient specific phantom was performed using a dedicated MC-code as DOSXYZnrc with PGT-irradiation model. The ratio of organ dose value calculated in MC-method to the volume CT dose index(CTDIvol) reported by CT-scanner machine according to PGT radiation technique has been introduced as conversion factor. Results: In PGT method, CTDIvol was 10.6mGy and Organ Dose/CTDIvol conversion factor for esophagus, lung, heart, breast, ribs, muscle, spine and spinal cord were obtained as; 0.96, 1.46, 1.2, 3.28. 6.68. 1.35, 3.41 and 0.93 respectively. Conclusion: The results showed while, underestimation of patient dose was found in dose calculation based on CTDIvol, also dose to breast is higher than the other studies. Therefore, the method in this study can be used to provide the actual patient organ dose in CT imaging based on CTDIvol in order to calculation of real effective dose(ED) based on organ dose. This work has been supported by the research chancellor of tehran university of medical sciences(tums), school of medicine, Tehran, Iran.

60 APPLIED LIFE SCIENCES↗

The observation of atmospheric structure with TOMS and some potential advancements

An overview is given of the Nimbus 7 Total Ozone Mapping Spectrometer (TOMS) which was designed to observe the spatial characteristics of total ozone that were not resolved by the nadir-viewing Nimbus BUV and SBUV instruments. At the wavelengths suitable for total ozone measurements, the radiance is large enough that the entire daytime atmosphere could be surveyed with about 50-km resolution from a polar orbiting satellite. The resulting high spatial resolution TOMS ozone images are found to reflect the internal dynamic structure of the lower atmosphere. Features which can be identified and tracked include: planetary wave scale troughs and ridges, mesoscale cutoff lows and rapidly moving troughs, jet stream confluence and difluence areas, hurricanes, and polar night lows. These features control the ozone above any given location and account for nearly all the variance in the total ozone. The instrument has been used to track the volcanic eruption clouds from El Chichon, Mount St. Helens, Alaid, and smaller eruptions such as Galunggung. It would be feasible to use a similar instrument on a geostationary platform to obtain half-hourly maps. Determination of the vertical ozone distribution in the lower stratosphere using Radon transform principles would be of importance in measuring jet stream folds and the related troposphere-stratosphere exchange.

Krueger, A. J.↗

Quantitative x-ray phase imaging at the nanoscale by multilayer Laue lenses

For scanning x-ray microscopy, many attempts have been made to image the phase contrast based on a concept of the beam being deflected by a specimen, the so-called differential phase contrast imaging (DPC). Despite the successful demonstration in a number of representative cases at moderate spatial resolutions, these methods suffer from various limitations that preclude applications of DPC for ultra-high spatial resolution imaging, where the emerging wave field from the focusing optic tends to be significantly more complicated. In this work, we propose a highly robust and generic approach based on a Fourier-shift fitting process and demonstrate quantitative phase imaging of a solid oxide fuel cell (SOFC) anode by multilayer Laue lenses (MLLs). The high sensitivity of the phase to structural and compositional variations makes our technique extremely powerful in correlating the electrode performance with its buried nanoscale interfacial structures that may be invisible to the absorption and fluorescence contrasts.

36 MATERIALS SCIENCE↗

STATISTICAL ANALYSIS OF THE VERY QUIET SUN MAGNETISM

The behavior of the observed polarization amplitudes with spatial resolution is a strong constraint on the nature and organization of solar magnetic fields below the resolution limit. We study the polarization of the very quiet Sun at different spatial resolutions using ground- and space-based observations. It is shown that 80% of the observed polarization signals do not change with spatial resolution, suggesting that, observationally, the very quiet Sun magnetism remains the same despite the high spatial resolution of space-based observations. Our analysis also reveals a cascade of spatial scales for the magnetic field within the resolution element. It is manifest that the Zeeman effect is sensitive to the microturbulent field usually associated with Hanle diagnostics. This demonstrates that Zeeman and Hanle studies show complementary perspectives of the same magnetism.

79 ASTRONOMY AND ASTROPHYSICS↗

A Concept for a High-Energy Gamma-ray Polarimeter

We present a concept for an imaging gamma-ray polarimeter operating from approx. 50 MeV to approx. 1 GeV. Such an instrument would be valuable for the study of high-energy pulsars, active galactic nuclei, supernova remnants, and gamma-ray bursts. The concept makes use of pixelized gas micro-well detectors, under development at Goddard Space Flight Center, to record the electron-positron tracks from pair-production events in a large gas volume. Pixelized micro-well detectors have the potential to form large-volume 3-D track imagers with approx. 100 micron (rms) position resolution at moderate cost. The combination of high spatial resolution and a continuous low-density gas medium permits many thousands of measurements per radiation length, allowing the particle tracks to be imaged accurately before multiple scattering masks their original directions. The polarization of the incoming radiation may then be determined from the azimuthal distribution of the electron-positron pairs. We have performed Geant4 simulations of these processes to estimate the polarization sensitivity as a function of instrument parameters and event selection criteria.

Bloser, P. F.↗

Mapping Boreal Forest Spruce Beetle Health Status at the Individual Crown Scale Using Fused Spectral and Structural Data

The frequency and severity of spruce bark beetle outbreaks are increasing in boreal forests leading to widespread tree mortality and fuel conditions promoting extreme wildfire. Detection of beetle infestation is a forest health monitoring (FHM) priority but is hampered by the challenges of detecting early stage (“green”) attack from the air. There is indication that green stage might be detected from vertical gradients of spectral data or from shortwave infrared information distributed within a single crown. To evaluate the efficacy of discriminating “non-infested”, “green”, and “dead” health statuses at the landscape scale in Alaska, USA, this study conducted spectral and structural fusion of data from: (1) Unoccupied aerial vehicle (UAV) multispectral (6 cm) + structure from motion point clouds (~700 pts per sq. m); and (2) Goddard Lidar Hyperspectral Thermal (G-LiHT) hyperspectral (400 to 1000 nm, 0.5 m) + SWIR-band lidar (~32 pts per sq.m). We achieved 78% accuracy for all three health statuses using spectral + structural fusion from either UAV or G-LiHT and 97% accuracy for non-infested/dead using G-LiHT. We confirm that UAV 3D spectral (e.g., greenness above versus below median height in crown) and lidar apparent reflectance metrics (e.g., mean reflectance at 99th percentile height in crown), are of high value, perhaps capturing the vertical gradient of needle degradation. In most classification exercises, UAV accuracy was lower than G-LiHT indicating that collecting ultra-high spatial resolution data might be less important than high spectral resolution information. While the value of passive optical spectral information was largely confined to the discrimination of non-infested versus dead crowns, G-LiHT hyperspectral band selection (~400, 675, 755, and 940 nm) could inform future FHM mission planning regarding optimal wavelengths for this task. Interestingly, the selected regions mostly did not align with the band designations for our UAV multispectral data but do correspond to, e.g., Sentinel-2 red edge bands, suggesting a path forward for moderate scale bark beetle detection when paired with suitable structural data.

Janice Cessna↗

Toward an integrated platform for characterizing laser-driven, isochorically heated plasmas with 1 µm spatial resolution

Warm dense matter is a region of phase space that is of high interest to multiple scientific communities ranging from astrophysics to inertial confinement fusion. Further understanding of the conditions and properties of this complex state of matter necessitates experimental benchmarking of the current theoretical models. We discuss the development of an x-ray radiography platform designed to measure warm dense matter transport properties at large laser facilities such as the OMEGA Laser Facility. Our platform, Fresnel Diffractive Radiography, allows for high spatial resolution imaging of isochorically heated targets, resulting in notable diffractive effects at sharp density gradients that are influenced by transport properties such as thermal conductivity. We discuss initial results, highlighting the capabilities of the platform in measuring diffractive features with micron-level spatial resolution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-resolution x-ray imaging using a structured scintillator

Purpose: In this study, the authors introduce a new generation of finely structured scintillators with a very high spatial resolution (a few micrometers) compared to conventional scintillators, yet maintaining a thick absorbing layer for improved detectivity. Methods: Their concept is based on a 2D array of high aspect ratio pores which are fabricated by ICP etching, with spacings (pitches) of a few micrometers, on silicon and oxidation of the pore walls. The pores were subsequently filled by melting of powdered CsI(Tl), as the scintillating agent. In order to couple the secondary emitted photons of the back of the scintillator array to a CCD device, having a larger pixel size than the pore pitch, an open optical microscope with adjustable magnification was designed and implemented. By imaging a sharp edge, the authors were able to calculate the modulation transfer function (MTF) of this finely structured scintillator. Results: The x-ray images of individually resolved pores suggest that they have been almost uniformly filled, and the MTF measurements show the feasibility of a few microns spatial resolution imaging, as set by the scintillator pore size. Compared to existing techniques utilizing CsI needles as a structured scintillator, their results imply an almost sevenfold improvement in resolution. Finally, high resolution images, taken by their detector, are presented. Conclusions: The presented work successfully shows the functionality of their detector concept for high resolution imaging and further fabrication developments are most likely to result in higher quantum efficiencies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution far-infrared observations of the Ring Nebula

High spatial resolution 50 and 100 micron observations of the Ring Nebula reveal a far-infrared emission peak close to the center of the nebula where atomic and molecular emission is at a minimum. Dust in this central peak emission region is heated by direct absorption of radiation from the central star. While the dust temperature in the central peak region is about 50 K (dust emissivity index of 1.5), the temperature of the bulk of the dust located in the regions of the ionized nebular core and the neutral molecular gas is on average lower than 50 K. Ly(alpha) photons are sufficient for heating the dust grains within the nebular core. Far-infrared emission is also found from grains mixed with the molecular gas outside the main ionized nebular core.

Zhang, C. Y.↗

Deep Neural Network High Spatiotemporal Resolution Precipitation Estimation (Deep-STEP) Using Passive Microwave and Infrared Data

Recent developments in “headline-making” deep neural networks (DNNs), specifically convolutional neural networks (CNNs), along with advancements in computational power, open great opportunities to integrate massive amounts of real-time observations to characterize spatiotemporal structures of surface precipitation. This study aims to develop a CNN algorithm, named Deep Neural Network High Spatiotemporal Resolution Precipitation Estimation (Deep-STEP), that ingests direct satellite passive microwave (PMW) brightness temperatures (Tbs) at emission and scattering frequencies combined with infrared (IR) Tbs from geostationary satellites and surface information to automatically extract geospatial features related to the precipitable clouds. These features allow the end-to-end Deep-STEP algorithm to instantaneously map surface precipitation intensities with a spatial resolution of 4 km. The main advantages of Deep-STEP, as compared to current state-of-the-art techniques, are 1) it learns and estimates complex precipitation systems directly from raw measurements in near–real time, 2) it uses the automatic spatial neighborhood feature extraction approach, and 3) it fuses coarse-resolution PMW footprints with IR images to reliably retrieve surface precipitation at a high spatial resolution. We anticipate our proposed DNN algorithm to be a starting point for more sophisticated and efficient precipitation retrieval systems in terms of accuracy, fine spatial pattern detection skills, and computational costs.

54 ENVIRONMENTAL SCIENCES↗

Development of a novel depth of interaction PET detector using highly multiplexed G-APD cross-strip encoding

Purpose: The aim of this study was to develop a prototype PET detector module for a combined small animal positron emission tomography and magnetic resonance imaging (PET/MRI) system. The most important factor for small animal imaging applications is the detection sensitivity of the PET camera, which can be optimized by utilizing longer scintillation crystals. At the same time, small animal PET systems must yield a high spatial resolution. The measured object is very close to the PET detector because the bore diameter of a high field animal MR scanner is limited. When used in combination with long scintillation crystals, these small-bore PET systems generate parallax errors that ultimately lead to a decreased spatial resolution. Thus, we developed a depth of interaction (DoI) encoding PET detector module that has a uniform spatial resolution across the whole field of view (FOV), high detection sensitivity, compactness, and insensitivity to magnetic fields. Methods: The approach was based on Geiger mode avalanche photodiode (G-APD) detectors with cross-strip encoding. The number of readout channels was reduced by a factor of 36 for the chosen block elements. Two 12 × 2 G-APD strip arrays (25μm cells) were placed perpendicular on each face of a 12 × 12 lutetium oxyorthosilicate crystal block with a crystal size of 1.55 × 1.55 × 20 mm. The strip arrays were multiplexed into two channels and used to calculate the x, y coordinates for each array and the deposited energy. The DoI was measured in step sizes of 1.8 mm by a collimated {sup 18}F source. The coincident resolved time (CRT) was analyzed at all DoI positions by acquiring the waveform for each event and applying a digital leading edge discriminator. Results: All 144 crystals were well resolved in the crystal flood map. The average full width half maximum (FWHM) energy resolution of the detector was 12.8% ± 1.5% with a FWHM CRT of 1.14 ± 0.02 ns. The average FWHM DoI resolution over 12 crystals was 2.90 ± 0.15 mm. Conclusions: The novel DoI PET detector, which is based on strip G-APD arrays, yielded a DoI resolution of 2.9 mm and excellent timing and energy resolution. Its high multiplexing factor reduces the number of electronic channels. Thus, this cross-strip approach enables low-cost, high-performance PET detectors for dedicated small animal PET and PET/MRI and potentially clinical PET/MRI systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution ptychographic imaging enabled by high-speed multi-pass scanning

As a coherent diffraction imaging technique, ptychography provides high-spatial resolution beyond Rayleigh’s criterion of the focusing optics, but it is also sensitively affected by the decoherence coming from the spatial and temporal variations in the experiment. Here we show that high-speed ptychographic data acquisition with short exposure can effectively reduce the impact from experimental variations. To reach a cumulative dose required for a given resolution, we further demonstrate that a continuous multi-pass scan via high-speed ptychography can achieve high-resolution imaging. This low-dose scan strategy is shown to be more dose-efficient, and has potential for radiation-sensitive sample studies and time-resolved imaging.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Three-dimensional high-content imaging of unstained soft tissue with subcellular resolution using a laboratory-based X-ray microscope

With increasing interest in studying biological systems across spatial scales—from centimeters down to nanometers—histology continues to be the gold standard for tissue imaging at cellular resolution, providing an essential bridge between macroscopic and nanoscopic analysis. However, its inherently destructive and two-dimensional nature limits its ability to capture the full three-dimensional complexity of tissue architecture. Here, we show that phase-contrast X-ray microscopy can enable three-dimensional virtual histology with subcellular resolution. This technique provides direct quantification of electron density without restrictive assumptions, allowing for direct characterization of cellular nuclei in a standard laboratory setting. By combining high spatial resolution and soft tissue contrast, with automated segmentation of cell nuclei, we demonstrated virtual Hematoxylin and Eosin (H&E) staining using machine learning-based style transfer, yielding volumetric datasets compatible with existing histopathological analysis tools. Furthermore, by integrating electron density and the sensitivity to nanometric features of the dark field contrast channel, we achieve stain-free, high-content imaging capable of distinguishing nuclei and extracellular matrix.

3D virtual histology↗