Search NASA⌕ Search

SEARCH · Search NASA

Results for “Humidity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Lightweight Fiber Optic Gas Sensor for Monitoring Regenerative Food Production

In this final report, Physical Optics Corporation (POC) describes its development of sensors for oxygen, carbon dioxide, and relative humidity. POC has constructed a phase fluorometer that can detect oxygen over the full concentration range from 0 percent to 100 percent. Phase-based measurements offer distinct advantages, such as immunity to source fluctuation, photobleaching, and leaching. All optics, optoelectronics, power supply, and the printed circuit board are included in a single box; the only external connections to the fluorometer are the optical fiber sensor and a power cord. The indicator-based carbon dioxide sensor is also suitable for short-term and discrete measurements over the concentration range from 0 percent to 100 percent. The optical fiber-based humidity sensor contains a porous core for direct interaction of the light beam with water vapor within fiber pores; the detection range for the humidity sensor is 10 percent to 100 percent, and response time is under five minutes. POC is currently pursuing the commercialization of these oxygen and carbon dioxide sensors for environmental applications.

Schmidlin, Edward↗

Surface Chemistry, Friction, and Wear Properties of Untreated and Laser-Annealed Surfaces of Pulsed-Laser-Deposited WS(sub 2) Coatings

An investigation was conducted to examine the surface chemistry, friction, and wear behavior of untreated and annealed tungsten disulfide (WS2) coatings in sliding contact with a 6-mm-diameter 440C stainless-steel ball. The WS2 coatings and annealing were performed using the pulsed-laser-deposition technique. All sliding friction experiments were conducted with a load of 0.98 N (100 g), an average Hertzian contact pressure of 0.44 GPa, and a constant rotating speed of 120 rpm. The sliding velocity ranged from 31 to 107 mm/s because of the range of wear track radii involved in the experiments. The experiment was performed at room temperature in three environments: ultrahigh vacuum (vacuum pressure, 7X(exp -10) Pa), dry nitrogen (relative humidity, less than 1 percent), and humid air (relative humidity, 15 to 40 percent). Analytical techniques, including scanning electron microscopy (SEM), energy-dispersive x-ray spectroscopy (EDX), x-ray photo electron spectroscopy (XPS), surface profilometry, and Vickers hardness testing, were used to characterize the tribological surfaces of WS2 coatings. The results of the investigation indicate that the laser annealing decreased the wear of a WS2 coating in an ultrahigh vacuum. The wear rate was reduced by a factor of 30. Thus, the laser annealing increased the wear life and resistance of the WS2 coating. The annealed WS 2 coating had a low coefficient of friction (less than O.1) and a low wear rate ((10(exp -7) mm(exp 3)/N-m)) both of which are favorable in an ultrahigh vacuum.

Miyoshi, Kazuhisa↗

Automated Test Systems for Toxic Vapor Detectors

The NASA Toxic Vapor Detection Laboratory (TVDL) at the Kennedy Space Center (KSC), Florida, has been using Personal Computer based Data Acquisition and Control Systems (PCDAS) for about nine years. These systems control the generation of toxic vapors of known concentrations under controlled conditions of temperature and humidity. The PCDAS also logs the test conditions and the test article responses in data files for analysis by standard spreadsheets or custom programs. The PCDAS was originally developed to perform standardized qualification and acceptance tests in a search for a commercial off-the-shelf (COTS) toxic vapor detector to replace the hydrazine detectors for the Space Shuttle launch pad. It has since become standard test equipment for the TVDL and is indispensable in producing calibration standards for the new hydrazine monitors at the 10 part per billion (ppb) level. The standard TVDL PCDAS can control two toxic vapor generators (TVG's) with three channels each and two flow/ temperature / humidity (FTH) controllers and it can record data from up to six toxic vapor detectors (TVD's) under test and can deliver flows from 5 to 50 liters per minute (L/m) at temperatures from near zero to 50 degrees Celsius (C) using an environmental chamber to maintain the sample temperature. The concentration range for toxic vapors depends on the permeation source installed in the TVG. The PCDAS can provide closed loop control of temperature and humidity to two sample vessels, typically one for zero gas and one for the standard gas. This is required at very low toxic vapor concentrations to minimize the time required to passivate the sample delivery system. Recently, there have been several requests for information about the PCDAS by other laboratories with similar needs, both on and off KSC. The purpose of this paper is to inform the toxic vapor detection community of the current status and planned upgrades to the automated testing of toxic vapor detectors at the Kennedy Space Center.

Mattson, C. B.↗

Improved Estimates of Clear Sky Longwave Flux and Application to the Tropical Greenhouse Effect

The first objective of this investigation is to eliminate the clear-sky offset introduced by the scene-identification procedures developed for the Earth Radiation Budget Experiment (ERBE). Estimates of this systematic bias range from 10 to as high as 30 W/sq m. The initial version of the ScaRaB data is being processed with the original ERBE algorithm. Since the ERBE procedure for scene identification is based upon zonal flux averages, clear scenes with longwave emission well below the zonal mean value are mistakenly classified as cloudy. The erroneous classification is more frequent in regions with deep convection and enhanced mid- and upper-tropospheric humidity. We will develop scene identification parameters with zonal and/or time dependence to reduce or eliminate the bias in the clear- sky data. The modified scene identification procedure could be used for the ScaRaB-specific version of the Earth-radiation products. The second objective is to investigate changes in the clear-sky Outgoing Longwave Radiation (OLR) associated with decadal variations in the tropical and subtropical climate. There is considerable evidence for a shift in the climate state starting in approximately 1977. The shift is accompanied by higher SSTs in the equatorial Pacific, increased tropical convection, and higher values of atmospheric humidity. Other evidence indicates that the humidity in the tropical troposphere has been steadily increasing over the last 30 years. It is not known whether the atmospheric greenhouse effect has increased during this period in response to these changes in SST and precipitable water. We will investigate the decadal-scale fluctuations in the greenhouse effect using Nimbus-7, ERBE, and ScaRaB measurements spaning 1979 to the present. The data from the different satellites will be intercalibrated by comparison with model calculations based upon ship radiosonde observations. The fluxes calculated from the radiation model will also be used for validation of the ScaRaB fluxes.

Collins, W. D.↗

Comparative Stress Corrosion Cracking and General Corrosion Resistance of Annealed and Hardened 440 C Stainless Steel - New Techniques in Stress Corrosion Testing

The corrosion and stress corrosion cracking (SCC) characteristics of annealed and hardened 440C stainless steel were evaluated in high humidity and 3.5-percent NaCl solution. Corrosion testing consisted of an evaluation of flat plates, with and without grease, in high humidity, as well as electrochemical testing in 3.5-percent NaCl. Stress corrosion testing consisted of conventional, constant strain, smooth bar testing in high humidity in addition to two relatively new techniques under evaluation at MSFC. These techniques involve either incremental or constant rate increases in the load applied to a precracked SE(B) specimen, monitoring the crack-opening-displacement response for indications of crack growth. The electrochemical corrosion testing demonstrated an order of magnitude greater general corrosion rate in the annealed 440C. All techniques for stress corrosion testing showed substantially better SCC resistance in the annealed material. The efficacy of the new techniques for stress corrosion testing was demonstrated both by the savings in time and the ability to better quantify SCC data.

Mendreck, M. J.↗

Overview of the International Space Station System Level Trace Contaminant Injection Test

Trace contaminant control onboard the International Space Station will be accomplished not only by the Trace Contaminant Control Subassembly but also by other Environmental Control and Life Support System subassemblies. These additional removal routes include absorption by humidity condensate in the Temperature and Humidity Control Condensing Heat Exchanger and adsorption by the Carbon Dioxide Removal Assembly. The Trace Contaminant Injection Test, which was performed at NASA's Marshall Space Flight Center, investigated the system-level removal of trace contaminants by the International Space Station Atmosphere Revitalization, and Temperature/Humidity Control Subsystems, (November-December 1997). It is a follow-on to the Integrated Atmosphere Revitalization Test conducted in 1996. An estimate for the magnitude of the assisting role provided by the Carbon Dioxide Removal Assembly and the Temperature and Humidity Control unit was obtained. In addition, data on the purity of Carbon Dioxide Removal Assembly carbon dioxide product were obtained to support Environmental Control and Life Support System Air Revitalization Subsystem loop closure.

Tatara, James D.↗

Millimeter-Wave Imaging Radiometer (MIR) Data Processing and Development of Water Vapor Retrieval Algorithms

This document describes the final report of the Millimeter-wave Imaging Radiometer (MIR) Data Processing and Development of Water Vapor Retrieval Algorithms. Volumes of radiometric data have been collected using airborne MIR measurements during a series of field experiments since May 1992. Calibrated brightness temperature data in MIR channels are now available for studies of various hydrological parameters of the atmosphere and Earth's surface. Water vapor retrieval algorithms using multichannel MIR data input are developed for the profiling of atmospheric humidity. The retrieval algorithms are also extended to do three-dimensional mapping of moisture field using continuous observation provided by airborne sensor MIR or spaceborne sensor SSM/T-2. Validation studies for water vapor retrieval are carried out through the intercomparison of collocated and concurrent measurements using different instruments including lidars and radiosondes. The developed MIR water vapor retrieval algorithm is capable of humidity profiling under meteorological conditions ranging from clear column to moderately cloudy sky. Simulative water vapor retrieval studies using extended microwave channels near 183 and 557 GHz strong absorption lines indicate feasibility of humidity profiling to layers in the upper troposphere and improve the overall vertical resolution through the atmosphere.

Chang, L. Aron↗

Parameterizations of Depositional Growth of Cloud Ice in a Bulk Microphysical Scheme

Two aspects of the cloud ice parameterization in the Goddard Cumulus Ensemble Model cloud physics parameterization are examined: the conversion of cloud ice to snow by depositional growth, designated PSFI, and the saturation adjustment scheme. The original formulation of PSFI is shown to produce excessive conversion of cloud ice to snow because of an implicit assumption that the relative humidity is 100% with respect to water even though the air may actually be quite less humid. Two possible corrections to this problem are proposed, the first involving application of a relative humidity dependent correction factor to the original formulation of PSFI, and the second involving a new formulation of PSFI based on the equation for depositional growth of cloud ice. The sensitivity of these formulations of PSFI to the assumed masses of the ice particles is examined. Possible problems associated with using a saturation adjustment scheme for cloud ice are discussed and simulations of a squall line with and without application of the adjustment scheme for ice are compared.

Braun, Scott A.↗

An Optimal Relation of Radar Reflectivity to Lightning Rate

Thunderstorms separate charge. Most places they lift positive charge or lower negative, a few places they lift negative or lower positive. The electrical generator is stronger in some parts of the cloud than in others. Our long term goal is to map this generator. Cloud physicists tell us that uncharged ice and water particles become charged by collision, and that the charge transferred depends on size, temperature and humidity. There is still some disagreement about exactly how the charge transferred depends on size, temperature, and humidity. In principle, if we knew this ice physics, and also knew the distribution of particles everywhere in the storm, and the winds everywhere and the temperature and humidity everywhere, then we could compute everywhere the electrical power of the thunderstorm generator. In practice it is difficult to know all these things, particularly the distribution of particles, so it is difficult to use real thunderstorms to falsify cloud electrification theories. We here take one small step towards computing that map of electrical generator power, by relating radar reflectivity profiles of 2000 storms to lightning flash rates of those storms. This small step by itself doesn't falsify any existing electrification theories; it merely places weak constraints on the relation of electric generator power to cloud ice.

Heckman, S.↗

Comments on "The Sensitivity Study of Radiative-Convective Equilibrium in the Tropics with a Convective Resolving Model"

In general, there are two broad scientific objectives when using cloud resolving models (CRMs or cloud ensemble models-CEMs) to study tropical convection. The first one is to use them as a physics resolving models to understand the dynamic and microphysical processes associated with the tropical water and energy cycles and their role in the climate system. The second approach is to use the CRMs to improve the representation of moist processes and their interaction with radiation in large-scale models. In order to improve the credibility of the CRMs and achieve the above goals, CRMs using identical initial conditions and large-scale influences need to produce very similar results. Two CRMs produced different statistical equilibrium (SE) states even though both used the same initial thermodynamic and wind conditions. Sensitivity tests to identify the major physical processes that determine the SE states for the different CRM simulations were performed. Their results indicated that atmospheric horizontal wind is treated quite differently in these two CRMs. The model that had stronger surface winds and consequently larger latent and sensible heat fluxes from the ocean produced a warmer and more humid modeled thermodynamic SE state. In addition, the domain mean thermodynamic state is more unstable for those experiments that produced a warmer and more humid SE state. Their simulated wet (warm and humid) SE states are thermally more stable in the lower troposphere (from the surface to 4-5 km in altitude). The large-scale horizontal advective effects on temperature and water vapor mixing ratio are needed when using CRMs to perform long-term integrations to study convective feedback under specified large-scale environments. In addition, it is suggested that the dry and cold SE state simulated was caused by enhanced precipitation but not enough surface evaporation. We find some problems with the interpretation of these three phenomena.

Tao, W.-K.↗

Does The Earth Have an Adaptive Infrared Iris?

Observations and analyses of water vapor and clouds in the tropics over the past decade suggest a different approach to radiative climate feedbacks: namely, that high clouds and high free-tropospheric relative humidity are largely tied to each other, and that the main feedback consists in changing the relative areas of cloudy/moist regions vis a vis clear/dry regions in response to the surface temperature of the cloudy/moist regions - as opposed to altering the humidity in either of the regions. This is an intrinsically 2-dimensional (horizontal and vertical) effect which does not readily enter simple 1-dimensional (vertical) radiative-convective schemes which emphasize average humidity, etc. Preliminary analyses of cloud data for the eastern part of the Western Pacific from the Japanese GMS-5(Geostationary Meteorological Satellite), are supportive of this suggestion - pointing to a 15% reduction in cloudy/moist area for a 1C increase of the sea surface temperature as measured by the cloud-weighted SST (sea surface temperature). The implication of this result is examined using a simple 2-dimensional radiative-convective model. The calculations show that such a change in the tropics would lead to a strong negative feedback in the global climate, with a feedback factor of about -1.7, which, if correct, would easily dominate the positive water vapor feedback found in current models. This new feedback mechanism, in effect, constitutes an adaptive infrared iris that opens and closes in order to control the OLR (outgoing longwave radiation) in response to changes in surface temperature in a manner similar to the way in which an eye's iris opens and closes in response to changing light levels. The climate sensitivity resulting from this thermostatic mechanism is consistent with the independent determination by Lindzen and Giannitisis (1998). Preliminary attempts to replicate observations with GCMs (General Circulation Models) suggest that models lack such a negative cloud/moist areal feedback.

Lindzen, Richard S.↗

Kinematic and Moisture Environments of Convective Systems During TRMM-LBA: Preliminary Sounding Analyses

Preliminary radiosonde data are analyzed from a four station observation network that operated during TRMM-LBA. These data, which are undergoing quality control, are used to construct mean vertical profiles and time-height sections of u- and v- wind components, and also filtered time series analyses of layer mean relative humidity. Trends are identified in the humidity data which appear similar at all sites, and correlate well with multi-week changes in wind regime identified by Rickenbach et al. Higher-frequency modes of variation (3-5 day) also occur in the humidity and upper tropospheric winds and are spatially coherent among the four locations. The causes of these variations are explored, including interactions among upper tropospheric synoptic features. Finally, an attempt is made to relate the general morphology of convective systems to the vertical shear structure and thermodynamic changes that accompany contrasting wind regimes.

Halverson, J. B.↗

Parameterizations of Depositional Growth of Cloud Ice in a Bulk Microphysical Scheme

The conversion of cloud ice to snow by depositional growth, designated P(sub SFI), in the Goddard Cumulus Ensemble Model cloud physics parameterization is examined. The original formulation of P(sub SFI) is shown to produce excessive conversion of cloud ice to snow because of an implicit assumption that the relative humidity is 100% with respect to water even though the air may actually be quite less humid. Two possible corrections to this problem are proposed, the first involving application of a relative humidity dependent correction factor to the original formulation of P(sub SFI), and the second involving a new formulation of P(sub SFI) based on the equation for depositional growth of cloud ice.

Braun, Scott A.↗

Environmental Characteristics of Convective Systems During TRMM-LBA

In this paper, data collected from 51 days of continual upper atmospheric soundings and TOGA radar at ABRACOS Hill during the TRMM-LBA experiment are used to describe the mean thermodynamic and kinematic airmass properties of wet season convection over Rondonia, Brazil. Distinct multi-day easterly and westerly lower tropospheric wind regimes occurred during the campaign with contrasting airmass characteristics. Westerly wind periods featured modest CAPE (1000 J/kg), moist conditions (>90% RH) extending through 700 mb and shallow (900 mb) speed shear on the order of 10(exp -4)/s. This combination of characteristics promoted convective systems that featured a relatively large fraction of stratiform rainfall and weak convection nearly devoid of lightning. The environment is very similar to the general airmass conditions experienced during the Darwin, Australia monsoon convective regime. In contrast, easterly regime convective systems were more strongly electrified and featured larger convective rain rates and reduced stratiform rainfall fraction. These systems formed in an environment with significantly larger CAPE (1500 J/kg), drier lower and middle level humidities (< 80% RH) and a wind shear layer that was both stronger (10(exp -3)/s) and deeper (700 mb). The larger CAPE resulted from strong insolation under relatively cloud-free skies (owing to reduced column humidity) and was also weakly capped in the lowest 1-2 km, thus contributing to a more explosive growth of convection. The time series of low- and mid-level averaged humidity exhibited marked variability between westerly and easterly regimes and was characterized by low frequency (i.e., multi-day to weekly) oscillations. The synoptic scale origins of these moisture fluctuations are examined, which include the effects of variable low-level airmass trajectories and upper-level, westward migrating cyclonic vortices. The results reported herein provide an environmental context for ongoing dual Doppler analyses and numerical modeling case studies of individual TRMM-LBA convective systems.

Halverson, Jeffrey B.↗

Occurrence of Ice Supersaturations, Ice Clouds, and Ternary Aerosols in the Arctic Lowermost Stratosphere

Relative humidity, aerosol concentration, and ice crystals all have important impacts on chemistry and radiative transfer in the lowermost stratosphere. In this study, we have combined SOLVE measurements with meteorological analyses to investigate the statistics of humidity, aerosols, and clouds in the arctic lower stratosphere. First, we will present a statistical analysis of relative humidity with respect to ice in the lowermost stratosphere, used on the DC-8 in situ measurements. We will show examples of ice supersaturation well within the stratosphere. Generally, these cases were associated with extremely low temperatures near the tropopause. Next, we will discuss the climatological occurrence frequency of tropopause temperatures low enough for ice saturation even with typically low stratospheric water vapor mixing ratios. Really, we will examine case studies of ice clouds observed in the lowermost stratosphere during SOLVE. We will discuss the possible origin of these clouds (i.e., precipitation from higher type II PSCs, injection of tropospheric air into the lower stratosphere, etc.).

Jensen, Eric↗

The Plant Research Unit: An International Space Station Habitat

The Plant Research Unit (PRU) is one of six life science habitats being developed as part of the Space Station Biological Research Program. The PRU is designed for experiments in microgravity and will utilize the ISS Centrifuge Facility to provide gravity levels between microgravity and 29. The PRU will provide and control all aspects of a plant s needs in a nearly closed system. In other words, the shoot and root environments will not be open to the astronaut s environment except for experiment maintenance such as planting, harvesting and plant sampling. This also means that all lighting, temperature and humidity control, "watering," and air filtering and cleaning .must be done within strict limitations of volume, weight, power, and crew time while at the same time providing a very high level of reliability and a service life in excess of 10 years. The PRU will contain two plant chambers 31.5 cm tall, each with independent control of temperature, humidity, light level and photoperiod, CO2 level, nutrient and water delivery, and video and data acquisition. The PRU is currently in the preliminary design phase and a number of subsystem components have been prototyped for testing, including the temperature and humidity control systems, the plant chambers, the LED lighting system, the atmospheric control system and a variety of nutrient delivery systems. The LED prototype provides independent feedback control of 5 separate spectral bands and variable output between 0 and 1000 micro-mol sq m/sec. The water and nutrient delivery system (WNDS) prototypes have been used to test particulate based, thin film, and gel-based WNDS configurations.

Morrow, Robert↗

Investigation Leads to Improved Understanding of Space Shuttle RSRM Internal Insulation Joints

The Space Shuttle Reusable Solid Rocket Motor (RSRM) uses an internal insulation J-joint design for the mated insulation interface between two assembled RSRM segments. In this assembled (mated) segment configuration, this J-joint design serves as a thermal barrier to prevent hot gases from affecting the case field joint metal surfaces and O-rings. A pressure sensitive adhesive (PSA) provides some adhesion between the two mated insulation surfaces. In 1995, after extensive testing, a new ODC-free PSA (free of ozone depleting chemicals) was selected for flight on RSRM-55 (STS-78). Post-flight inspection revealed that the J-joint, equipped with the new ODC-free PSA, did not perform well. Hot gas seeped inside the J-joint interface. Although not a flight safety threat, the J-joint hot gas intrusion on RSRM-55 was a mystery to the investigators since the PSA had previously worked well on a full-scale static test. A team was assembled to study the J-joint and PSA further. All J-joint design parameters, measured data, and historical performance data were re-reviewed and evaluated by subscale testing and analysis. Although both the ODC-free and old PSA were weakened by humidity, the ODC-free PSA strength was lower to start with. Another RSRM full-scale static test was conducted in 1998 and intentionally duplicated the gas intrusion. This test, along with many concurring tests, showed that if a J-joint was 1) mated with the new ODC-free PSA, 2) exposed to a history of high humidity (Kennedy Space Center levels), and 3) also a joint which experienced significant but normal joint motion (J-joint deformation resulting from motor pressurization dynamics) then that J-joint would open (allow gas intrusion) during motor operation. When all of the data from the analyses, subscale tests, and full-scale tests were considered together, a theory emerged. Most of the joint motion on the RSRM occurs early in motor operation at which point the J-joints are pulled into tension. If the new PSA has been weakened due to humidity, then the J-joint will partially pull apart (inboard side), and the J-joint surfaces will be charred by exposure to hot gases. After early operation, a J-joint that has been pulled apart will come back together as the J-joint deformation decreases. This J-joint heating event is relatively short and occurs only during the first part of motor operation. Internal instrumentation was developed for another full-scale static test in February 2000. The static test instrumentation did indeed prove this theory to be correct. Post-test inspection revealed very similar charring characteristics as observed on RSRM-55. This experience of the development of a new PSA, its testing, the RSRM-55 flight, followed by the J-joint investigation led to good 'lessons learned' and to an additional fundamental understanding of the RSRM J-joint function.

McWhorter, Bruce B.↗

Intercomparison of Latent Heat Fluxes Over Global Oceans

Turbulent fluxes of momentum, moisture, and heat at the air-sea interface are essential for climate studies. Version 2 Goddard Satellite-based Surface Turbulent Fluxes (GSSTF2) has been derived from the Special Sensor Microwave/Imager (SSM/I) radiance measurements. This dataset, covering the period July 1987-December 2000 over global oceans, has a spatial resolution of 1 deg x 1 deg lat-long and a temporal resolution of 1 day. Turbulent fluxes are derived from the SSM/I surface winds and surface air humidity, as well as the 2-m air and sea surface temperatures (SST) of the NCEP/NCAR reanalysis, using a bulk aerodynamic algorithm based on the surface layer similarity theory. The GSSTF2 bulk flux model, and retrieved daily wind stress, latent heat flux, wind speed, and surface air humidity validate well with ship observations of ten field experiments over the tropical and midlatitude oceans during 1991-99. The global distributions of 1988-2000 annual- and seasonal-mean turbulent fluxes show reasonable patterns related to the atmospheric general circulation and seasonal variations. Latent heat fluxes and related input parameters over global oceans during 1992-93 have been compared among GSSTF1 (version 1), GSSTF2, HOAPS (Hamburg Ocean Atmosphere Parameters and Fluxes from Satellite Data), NCEP/NCAR reanalysis, and one based on COADS (Comprehensive Ocean-Atmosphere Data Set). Our analyses suggest that the GSSTF2 latent heat flux, surface air humidity, surface wind, and SST are quite realistic compared to the other four flux datasets examined. However, significant differences are found among these five flux datasets. The GSSTF2, available at http://daac.gsfc.nasa.gov/CAMPAIGN_DOCS/hydrology/hd_gsstf2.O.html, is useful for climate studies.

Chou, Shu-Hsien↗