Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMAGE ALIGNMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Reflective all-sky thermal infrared cloud imager

A reflective all-sky imaging system has been built using a long-wave infrared microbolometer camera and a reflective metal sphere. This compact system was developed for measuring spatial and temporal patterns of clouds and their optical depth in support of applications including Earth-space optical communications. The camera is mounted to the side of the reflective sphere to leave the zenith sky unobstructed. The resulting geometric distortion is removed through an angular map derived from a combination of checkerboard-target imaging, geometric ray tracing, and sun-location-based alignment. A tape of high-emissivity material on the side of the reflector acts as a reference that is used to estimate and remove thermal emission from the metal sphere. In conclusion, once a bias that is under continuing study was removed, sky radiance measurements from the all-sky imager in the 8-14 μm wavelength range agreed to within 0.91 W/(m 2 sr) of measurements from a previously calibrated, lens-based infrared cloud imager over its 110° field of view.

47 OTHER INSTRUMENTATION↗

A Large Area Picosecond Photodetector for Neutron Transmission Measurements at DICER at LANSCE

The Device for Indirect Capture Experiments on Radionuclides (DICER) is a new instrument that is being developed at the Los Alamos Neutron Science Center (LANSCE) to study neutron capture reactions on short-lived radionuclides. To achieve that, DICER is using an indirect technique based on measuring the neutron transmission through very small samples (0.12–1.2 mm in diameter, $\mu \text{g}$ -mg in mass). The main detection system of DICER consists of two dual photomultiplier (PMT)-based detectors which are sensitive to the scintillation light produced when neutrons interact with 6 Li glass disks. DICER is developing a new collimation system that includes a 0.1-mm collimator. In such small sizes, the need for neutron beam imaging is crucial and necessary to confirm the appropriate alignment between the irradiated sample and the neutron detectors. The large area picosecond photodetector (LAPPD) is a multichannel plate (MCP)-based photodetector, with picosecond-level timing, single-photon detection capabilities, and spatial resolution of the order of 1 mm. Coupling the LAPPD with a 6 Li glass scintillator results in a neutron imaging detector. The first irradiation of the LAPPD at DICER indicated that apart from imaging the beam, the LAPPD can be used as the main neutron detection system. Furthermore, these results were proof of principle measurements demonstrating the capabilities of the beamline, and the challenge with small samples will be addressed in the future. The first efforts and developments, including irradiations of the LAPPD and the first beam images, will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physics-based reward driven image analysis in microscopy

The rise of electron microscopy has expanded our ability to acquire nanometer and atomically resolved images of complex materials. The resulting vast datasets are typically analyzed by human operators, an intrinsically challenging process due to the multiple possible analysis steps and the corresponding need to build and optimize complex analysis workflows. We present a methodology based on the concept of a Reward Function coupled with Bayesian Optimization, to optimize image analysis workflows dynamically. The Reward Function is engineered to closely align with the experimental objectives and broader context and is quantifiable upon completion of the analysis. Here, cross-section, high-angle annular dark field (HAADF) images of ion-irradiated (Y, Dy)Ba 2 Cu 3 O 7–δ thin-films were used as a model system. The reward functions were formed based on the expected materials density and atomic spacings and used to drive multi-objective optimization of the classical Laplacian-of-Gaussian (LoG) method. These results can be benchmarked against the DCNN segmentation. This optimized LoG* compares favorably against DCNN in the presence of the additional noise. We further extend the reward function approach towards the identification of partially-disordered regions, creating a physics-driven reward function and action space of high-dimensional clustering. We pose that with correct definition, the reward function approach allows real-time optimization of complex analysis workflows at much higher speeds and lower computational costs than classical DCNN-based inference, ensuring the attainment of results that are both precise and aligned with the human-defined objectives.

47 OTHER INSTRUMENTATION↗

Quantum imaging with positronium-decay-emitted gamma rays

The use of entangled gamma rays from positronium decay for quantum-enhanced imaging of dense materials is demonstrated. Quantum ghost images, where only one of the entangled 511-keV photons interacts with the object, are obtained for tantalum samples of varying density using a 210-ps time-resolution dual detector system and a Na-22 positron source. An analysis comparing both classical and quantum imaging modalities is employed to isolate true 511-keV events from background noise. Image quality is quantitatively assessed using transmission ratios and the Michelson contrast. Quantum-correlated images are found to exhibit superior (up to approximately 1.7x, from 0.49 to 0.83 in the thickest sample measured) contrast compared to classical methods and align well with theoretical expectations. These results suggest that quantum ghost imaging with positronium-based entangled gamma rays could significantly enhance noninvasive imaging of high-density objects, with potential applications in areas such as cargo inspection and security screening.

36 MATERIALS SCIENCE↗

WE-DE-BRA-03: Construction of An Ultrasound Guidance Platform for Image-Guided Radiotherapy with the Intent to Treat Transitional Cell Carcinoma

Purpose: Ultrasound (US) is a noninvasive, nonradiographic imaging technique with high spatial and temporal resolution that can be used for localizing soft-tissue structures and tumors in real-time during radiotherapy (inter- and intra-fraction). A detailed methodology integrating 3D-US within RT is presented. This method is easier to adopt into current treatment protocol than current US based systems and reduces user variability for image acquisition, thus eliminating transducer induced changes that limit CT planning system. Methods: We designed an in-house integrated US manipulator and platform to relate CT, 3D-US and linear accelerator coordinate systems. To validate the platform, an agar-based phantom with measured densities and speed-of-sound consistent with tissues surrounding the bladder, was rotated (0–45°) resulting in translations (up to 55mm) relative to the CT and US coordinate systems. After acquiring and integrating CT and US images into the treatment planning system, US-to-US and US-to-CT images were co-registered to re-align the phantom relative to the linear accelerator. Errors in the transformation matrix components were calculate to determine precision of this method under different patient positions. Results: Statistical errors from US-US registrations for different patient orientations ranged from 0.06–1.66mm for x, y, and z translational components, and 0.00–1.05° for rotational components. Statistical errors from US-CT registrations were 0.23–1.18mm for the x, y and z translational components, and 0.08–2.52° for the rotational components. Conclusion: Based on our result, this is consistent with currently used techniques for positioning prostate patients if couch re-positioning is less than a 5 degree rotation. We are now testing this on a dog patient to obtain both inter and intra-fractional positional errors. Additional design considerations include the future use of ultrasound-based functionality (photoacoustics, radioacoustics, Doppler) to monitor blood flow and hypoxia and/or in-vivo dosimetry for applications in other therapeutic techniques, such as hyperthermia, anti-angiogenesis, and particle therapy.

60 APPLIED LIFE SCIENCES↗

Analysis of X-ray images and spectra (aXis2000): A toolkit for the analysis of X-ray spectromicroscopy data

Spectromicroscopy refers to analytical methods that combine imaging and spectroscopy to provide detailed, spatially resolved analytical information about a sample, such as the type and quantitative spatial distributions of chemical components, geometric or magnetic alignment information, crystal structure, etc. The analysis of X-ray images and spectra (aXis2000) software described in this work provides a set of routines within a single, integrated, graphical-oriented package to read, display, manipulate and analyze spectromicroscopy data, with particular focus on soft X-ray spectromicroscopy methods such as scanning transmission X-ray microscopy (STXM), X-ray photoemission electron microscopy (XPEEM), scanning photoelectron X-ray microscopy (SPEM) and transmission X-ray microscopy (TXM). Here, this free software is described and compared to other software that can provide similar or complementary capabilities. Examples of spectromicroscopic analyses using advanced features of aXis2000 are provided.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-552: A One-Year Evaluation of the QABeamChecker+ for Use with the CyberKnife System

Purpose: By attaching an adapter plate with fiducial markers to the QA BeamChecker+ (Standard Imaging, Inc., Middleton, WI), the output of the CyberKnife can be accurately, efficiently, and consistently evaluated. The adapter plate, known as the Cutting Board, allows for automated alignment of the QABC+ using the CK’s stereoscopic kV image-based treatment localization system (TLS). Described herein is an evaluation of the system following a year of clinical utilization. Methods: Based on a CT scan of the QABC+ and CB, a treatment plan is generated which delivers a beam to each of the 5 plane-parallel ionization chambers. Following absolute calibration of the CK, the QA plan is delivered, and baseline measurements are acquired (and automatically corrected for temperature and pressure). This test was performed at the beginning of each treatment day for a year. A calibration evaluation (using a water-equivalent slab and short thimble chamber) is performed every four weeks, or whenever the QABC+ detects a deviation of more than 1.0%. Results: During baseline evaluation, repeat measurements (n=10) were performed, with an average output of 0.25% with an SD of 0.11%. As a test of the reposition of the QABC+ and CB, ten additional measurements were performed where between each acquisition, the entire system was removed and re-positioned using the TLS. The average output deviation was 0.30% with a SD of 0.13%. During the course of the year, 187 QABC+ measurements and 13 slab-based measurements were performed. The output measurements of the QABC+ correlated well with slab-based measurements (R2=0.909). Conclusion: By using the QABC+ and CB, daily output was evaluated accurately, efficiently, and consistently. From setup to break-down (including analysis), this test required 5 minutes instead of approximately 15 using traditional techniques (collimator-mounted ionization chambers). Additionally, by automatically saving resultant output deviation to a database, trend analysis was simplified. Spectrum Medical Physics, LLC of Greenville, SC has a consulting contract with Standard Imaging of Middleton, WI.

60 APPLIED LIFE SCIENCES↗

Electron beam loss assumptions for ELI-NPMEGa-ray radioprotection analysis

The ELI-NP project is now working on the design of their conventional facility. Dr. Gheorghe Cata-Danil recently requested that I provide them with information on the location and amount of electron-beam loss in the MEGa-ray source they have proposed for ELI-NP. This memo is intended to document that information, for transmission to ELI-NP. The ELI-NP MEGa-ray source, as presently proposed, consists of two x-band accelerator sections separated by a large chicane, as show in figure 1. The basic parameters of the machine that are pertinent for specifying the radiation source terms are shown in table 1. These are the parameters of the intentionally-produced photobeam. In addition to the photobeam, the electron gun and accelerator will produce 'dark current' that originates throughout the RF structures (that is, distributed along the accelerator axis) and therefore has a distribution of energy below the energy of the photobeam. Because it is emitted from surfaces inside the RF structures, much of it is not transported through the accelerator and is lost in the accelerator RF structures. A large fraction of the total dark current is produced in the photogun and lost at the entrance of the 1st accelerator RF structure. Important sources of radiation during operation are beam alignment screens that are used for observing the image of the electron beam, during adjustment of beam steering and for general diagnostic purposes. Each screen consists of a 1 mm thick Ce:YAG plate that is moved into the path of the beam when desired. This destroys the electron beam, spraying all beam current into the structures downstream of the screen. Only one screen is inserted at a time. These screens may be located after each accelerator RF structure, and after each set of bend magnets, as shown in figure 3. The photobeam energy and currents at each location are listed in table 2; for simplicity, the dark current energy is (conservatively) assumed to be the same as the photobeam energy. In normal operation, the locations of other beam losses and the estimated current and energy of the lost beam are listed in table 3. In addition to these 'normal' beam losses, it is assumed that the beam may be accidentally mis-steered by up to 1 degree at every steering magnet, so that it hits the surrounding beam tube and other structures. This loss can be modeled as occurring at the locations listed in table 2, numbers 1-7 and 16-21. Similarly, it is assumed that any of the dipole magnets, in chicanes or at the beam dump, may fail, resulting in total beam loss straight ahead. These locations can be assumed to be the same as listed in table 2, numbers 8-10, 12-14, 22-24, 26, and 27. The data provided above are estimates of the beam loss, for the purpose of calculating radiation source terms. Dark current estimates are conservative, until we acquire actual operational data. Neither the estimated currents nor the estimated energies listed above contain any intentional margin. when they have performed similar calculations for their own purposes, they have typically added approximately 10% to the beam energy to provide some overall margin in the analysis.

42 ENGINEERING↗

Hydrologic Impacts of a Strike-Slip Fault Zone: Insights from Joint 3D Body-Wave Tomography of Rock Valley

The Rock Valley fault zone (RVFZ), an intraplate strike-slip fault zone in the southern Nevada National Security Site (NNSS), hosted a series of very shallow (<3 km) earthquakes in 1993. The RVFZ may also have hydrological significance within the NNSS, potentially playing a role in regional groundwater flow, but there is a lack of local hydrological data. In the Spring of 2021, we collected active-source accelerated weight drop seismic data over part of the RVFZ to better characterize the shallow subsurface. Here, we manually picked ~17,000 P-wave travel times and over 14,000 S-wave travel times, which were inverted for P-wave velocity (V P ), S-wave velocity (V S ), and V P /V S ratio in a 3D joint tomographic inversion scheme. Seismic velocities are imaged as deep as ~700 m in areas and generally align with geologic and structural expectations. V P and V S are relatively reduced near mapped and inferred faults, with the most prominent lower V P and V S zone around the densest collection of faults. We image V P /V S ratios ranging from ~1.5 to ~2.4, the extremes of which occur at a depth of ~100 m and are juxtaposed across a fault. One possible interpretation of the imaged seismic velocities is enhanced fault damage near the densest collection of faults with relatively higher porosity and/or crack density at ~100 m depth, with patches of semiperched groundwater present in the sedimentary rock in higher V P /V S areas and drier rock in lower V P /V S areas. A relatively higher V P /V S area beneath the densest faults persists at depth, which suggests percolation of groundwater via the fault damage zone to the regionally connected lower carbonate aquifer. Potentially, the presence and movement of groundwater may have played a role in the 1993 earthquake aftershocks.

58 GEOSCIENCES↗

Highly aligned arrays of high aspect ratio barium titanate nanowires via hydrothermal synthesis

We report on the development of a hydrothermal synthesis procedure that results in the growth of highly aligned arrays of high aspect ratio barium titanate nanowires. Using a multiple step, scalable hydrothermal reaction, a textured titanium dioxide film is deposited on titanium foil upon which highly aligned nanowires are grown via homoepitaxy and converted to barium titanate. Scanning electron microscope images clearly illustrate the effect the textured film has on the degree of orientation of the nanowires. The alignment of nanowires is quantified by calculating the Herman's Orientation Factor, which reveals a 58% improvement in orientation as compared to growth in the absence of the textured film. The ferroelectric properties of barium titanate combined with the development of this scalable growth procedure provide a powerful route towards increasing the efficiency and performance of nanowire-based devices in future real-world applications such as sensing and power harvesting.

36 MATERIALS SCIENCE↗

Transmission Geometry Laser Ablation into a Non-Contact Liquid Vortex Capture Probe for Mass Spectrometry Imaging

RATIONALE: Capture of material from a laser ablation plume into a continuous flow stream of solvent provides the means for uninterrupted sampling, transport and ionization of collected material for coupling with mass spectral analysis. Reported here is the use of vertically aligned transmission geometry laser ablation in combination with a new non-contact liquid vortex capture probe coupled with electrospray ionization for spot sampling and chemical imaging with mass spectrometry. Methods: A vertically aligned continuous flow liquid vortex capture probe was positioned directly underneath a sample surface in a transmission geometry laser ablation (355 nm, 10 Hz, 7 ns pulse width) setup to capture into solution the ablated material. The outlet of the vortex probe was coupled to the Turbo V ion source of an AB SCIEX TripleTOF 5600+ mass spectrometer. System operation and performance metrics were tested using inked patterns and thin tissue sections. Glass slides and slides designed especially for laser capture microdissection, viz., DIRECTOR slides and PEN 1.0 (polyethylene naphthalate) membrane slides, were used as sample substrates. Results: The estimated capture efficiency of laser ablated material was 24%, which was enabled by the use of a probe with large liquid surface area (~ 2.8 mm2) and with gravity to help direct ablated material vertically down towards the probe. The swirling vortex action of the liquid surface potentially enhanced capture and dissolution of not only particulates, but also gaseous products of the laser ablation. The use of DIRECTOR slides and PEN 1.0 (polyethylene naphthalate) membrane slides as sample substrates enabled effective ablation of a wide range of sample types (basic blue 7, polypropylene glycol, insulin and cyctochrome c) without photodamage using a UV laser. Imaging resolution of about 6 m was demonstrated for stamped ink on DIRECTOR slides based on the ability to distinguish features present both in the optical and in the chemical image. This imaging resolution was 20 times better than the previous best reported results with laser ablation/liquid sample capture mass spectrometry imaging. Using thin sections of brain tissue the chemical image of a selected lipid was obtained with an estimated imaging resolution of about 50 um. Conclusions: A vertically aligned, transmission geometry laser ablation liquid vortex capture probe, electrospray ionization mass spectrometry system provides an effective means for spatially resolved spot sampling and imaging with mass spectrometry.

DIRECTOR slides↗

Laser beam centering and pointing system

An optical instrument aligns an optical beam without the need for physical intervention of the instrument within the apparatus or platforms from which the trajectory of the beam to be ascertained. The alignment apparatus and method enable the desired function to be realized without the placement of physical apertures or sensors directly in the path of the beam through the system whose spatial position and slope is to be sought. An image plane provides the observer with a pair of well-defined images that are indicative of the beam centering and pointing alignment parameters. The optical alignment can be realized without the need for referencing to an external or fixed set of coordinates or fiducials. The instrument can therefore service situations where adverse environments would otherwise prohibit the use of such instruments, including regions of high radiation, high temperature, vacuum and/or cryogenic atmospheres.

42 ENGINEERING↗

USING MEGAMASER DISKS TO PROBE BLACK HOLE ACCRETION

We examine the alignment between H{sub 2}O megamaser disks on subparsec scales with circumnuclear disks and bars on <500 pc scales observed with the Hubble Space Telescope (HST)/WFC3. The HST imaging reveals young stars, indicating the presence of gas. The megamaser disks are not well aligned with the circumnuclear bars or disks as traced by stars in the HST images. We speculate on the implications of the observed misalignments for fueling supermassive black holes in gas-rich spiral galaxies. In contrast, we find a strong preference for the rotation axes of the megamaser disks to align with radio continuum jets observed on {approx}> 50 pc scales, in those galaxies for which radio continuum detections are available. Subarcsecond observations of molecular gas with ALMA will enable a more complete understanding of the interplay between circumnuclear structures.

79 ASTRONOMY AND ASTROPHYSICS↗

CIEL ∗ Ch color map for visualization and analysis of sea ice motion

The International Commission on Illumination (CIE) designed its color space to be perceptually uniform so that a given numerical change in the color code corresponds to perceived change in color. This color encoding is demon- strated to be advantageous in scientific visualization and analysis of vector fields. The specific application is analysis of ice motion in the Arctic where patterns in smooth monthly-averaged ice motion are seen. Furthermore, fractures occurring in the ice cover result in discontinuities in the ice motion. This vector jump in displacement can also be visualized. We then analyze modeled and observed fractures through the use of a metric on the color space, and image amplitude and phase metrics. Amplitude and phase met- rics arise from image registration that is accomplished by sampling images using space filling curves, thus reducing the image registration problem to the more reliable functional alignment problem. We demonstrate this through an exploration of the metrics to compare model runs to an observed ice crack.

97 MATHEMATICS AND COMPUTING↗

LoTToR: An Algorithm for Missing-Wedge Correction of the Low-Tilt Tomographic 3D Reconstruction of a Single-Molecule Structure

A single-molecule three-dimensional (3D) structure is essential for understanding the thermal vibrations and dynamics as well as the conformational changes during the chemical reaction of macromolecules. Individual-particle electron tomography (IPET) is an approach for obtaining a snap-shot 3D structure of an individual macromolecule particle by aligning the tilt series of electron tomographic (ET) images of a targeted particle through a focused iterative 3D reconstruction method. The method can reduce the influence on the 3D reconstruction from large-scale image distortion and deformation. Due to the mechanical tilt limitation, 3D reconstruction often contains missing-wedge artifacts, presented as elongation and an anisotropic resolution. Here, we report a post-processing method to correct the missing-wedge artifact. This low-tilt tomographic reconstruction (LoTToR) method contains a model-free iteration process under a set of constraints in real and reciprocal spaces. A proof of concept is conducted by using the LoTToR on a phantom, i.e., a simulated 3D reconstruction from a low-tilt series of images, including that within a tilt range of ±15°. The method is validated by using both negative-staining (NS) and cryo-electron tomography (cryo-ET) experimental data. A significantly reduced missing-wedge artifact verifies the capability of LoTToR, suggesting a new tool to support the future study of macromolecular dynamics, fluctuation and chemical activity from the viewpoint of single-molecule 3D structure determination.

97 MATHEMATICS AND COMPUTING↗

Smooth cubic commensurate oxides on gallium nitride

Smooth, commensurate alloys of 〈111〉-oriented Mg{sub 0.52}Ca{sub 0.48}O (MCO) thin films are demonstrated on Ga-polar, c+ [0001]-oriented GaN by surfactant-assisted molecular beam epitaxy and pulsed laser deposition. These are unique examples of coherent cubic oxide|nitride interfaces with structural and morphological perfection. Metal-insulator-semiconductor capacitor structures were fabricated on n-type GaN. A comparison of leakage current density for conventional and surfactant-assisted growth reveals a nearly 100× reduction in leakage current density for the surfactant-assisted samples. HAADF-STEM images of the MCO|GaN interface show commensurate alignment of atomic planes with minimal defects due to lattice mismatch. STEM and DFT calculations show that GaN c/2 steps create incoherent boundaries in MCO over layers which manifest as two in-plane rotations and determine consequently the density of structural defects in otherwise coherent MCO. This new understanding of interfacial steps between HCP and FCC crystals identifies the steps needed to create globally defect-free heterostructures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nanoscale Conductivity Imaging of Correlated Electronic States in WSe 2 /WS 2 Moiré Superlattices

We report the nanoscale conductivity imaging of correlated electronic states in angle-aligned WSe 2 /WS 2 heterostructures using microwave impedance microscopy. Here, the noncontact microwave probe allows us to observe the Mott insulating state with one hole per moiré unit cell that persists for temperatures up to 150 K, consistent with other characterization techniques. In addition, we identify for the first time a Mott insulating state at one electron per moiré unit cell. Appreciable inhomogeneity of the correlated states is directly visualized in the hetero-bilayer region, indicative of local disorders in the moiré superlattice potential or electrostatic doping. Our work provides important insights on 2D moiré systems down to the microscopic level.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-throughput full-automatic synchrotron-based tomographic microscopy

At the TOMCAT (TOmographic Microscopy and Coherent rAdiology experimenTs) beamline of the Swiss Light Source with an energy range of 8-45 keV and voxel size from 0.37 {micro}m to 7.4 {micro}m, full tomographic datasets are typically acquired in 5 to 10 min. To exploit the speed of the system and enable high-throughput studies to be performed in a fully automatic manner, a package of automation tools has been developed. The samples are automatically exchanged, aligned, moved to the correct region of interest, and scanned. This task is accomplished through the coordination of Python scripts, a robot-based sample-exchange system, sample positioning motors and a CCD camera. The tools are suited for any samples that can be mounted on a standard SEM stub, and require no specific environmental conditions. Up to 60 samples can be analyzed at a time without user intervention. The throughput of the system is dependent on resolution, energy and sample size, but rates of four samples per hour have been achieved with 0.74 {micro}m voxel size at 17.5 keV. The maximum intervention-free scanning time is theoretically unlimited, and in practice experiments have been running unattended as long as 53 h (the average beam time allocation at TOMCAT is 48 h per user). The system is the first fully automated high-throughput tomography station: mounting samples, finding regions of interest, scanning and reconstructing can be performed without user intervention. The system also includes many features which accelerate and simplify the process of tomographic microscopy.

43 PARTICLE ACCELERATORS↗