Search NASA⌕ Search

SEARCH · Search NASA

Results for “INTERFEROMETER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Multiwavelength erbium-doped fiber laser based on a polarization-dependent in-line Mach–Zehnder interferometer

A multiwavelength erbium-doped fiber laser based on a polarization-dependent in-line Mach–Zehnder Interferometer (in-line MZI) is proposed and experimental demonstrated. The polarization-dependent in-line MZI demonstrated is constructed by sandwiching a length of polarization maintaining fiber (PMF) between two abrupt fiber tapers fabricated in SMF. The proposed in-line MZI can work as a cost-effective all-fiber-based polarizer. In combination with the nonlinear polarization rotation technique, stable multiwavelength laser comb with uniform wavelength spacing is achieved at room temperature. The wavelength spacing is 0.8 nm. By properly tuning the PCs, the output laser combs with double and triple channel spacing can be also obtained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Waveform modelling for the Laser Interferometer Space Antenna

LISA, the Laser Interferometer Space Antenna, will usher in a new era in gravitational-wave astronomy. As the first anticipated space-based gravitational-wave detector, it will expand our view to the millihertz gravitational-wave sky, where a spectacular variety of interesting new sources abound: from millions of ultra-compact binaries in our Galaxy, to mergers of massive black holes at cosmological distances; from the early inspirals of stellar-mass black holes that will ultimately venture into the ground-based detectors’ view to the death spiral of compact objects into massive black holes, and many sources in between. Central to realising LISA’s discovery potential are waveform models, the theoretical and phenomenological predictions of the pattern of gravitational waves that these sources emit. This White Paper is presented on behalf of the Waveform Working Group for the LISA Consortium. It provides a review of the current state of waveform models for LISA sources, and describes the significant challenges that must yet be overcome.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Photon wave function formalism for analysis of Mach–Zehnder interferometer and sum-frequency generation

Biakynicki-Birula introduced a photon wave function similar to the matter wave function that satisfies the Schrödinger equation. Its second quantization form can be applied to investigate nonlinear optics at nearly full quantum level. In this paper, we applied the photon wave function formalism to analyze both linear optical processes in the well-known Mach–Zehnder interferometer and nonlinear optical processes for sum-frequency generation in dispersive and lossless medium. Results by photon wave function formalism agree with the well-established Maxwell treatments and existing experimental verifications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adiabatic Mach–Zehnder interferometer in a dipolar spin-1 condensate

We propose and analyze a realizable scheme for performing a Heisenberg-limited Mach–Zehnder interferometry with a dipolar spin-1 condensate. Based upon adiabatic processes of sweeping the transverse magnetic field, we demonstrate a perfect phase transition, which accomplishes the beam splitter, phase shifter and recombiner as for a Mach–Zehnder interferometer. The attractive dipolar interaction ensures the existence of a path-entangled state which enhances the phase measurement precision to the Heisenberg limit. We also study the spin squeezing of the state generated in the beam splitter and show that the spin squeezing exhibits an extremum near the critical point of phase transition.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a GPU-based high-performance radiative transfer model for the Infrared Atmospheric Sounding Interferometer (IASI)

Satellite-observed radiance is a nonlinear functional of surface properties and atmospheric temperature and absorbing gas profiles as described by the radiative transfer equation (RTE). In the era of hyperspectral sounders with thousands of high-resolution channels, the computation of the radiative transfer model becomes more time-consuming. The radiative transfer model performance in operational numerical weather prediction systems still limits the number of channels we can use in hyperspectral sounders to only a few hundreds. To take the full advantage of such high-resolution infrared observations, a computationally efficient radiative transfer model is needed to facilitate satellite data assimilation. In recent years the programmable commodity graphics processing unit (GPU) has evolved into a highly parallel, multi-threaded, many-core processor with tremendous computational speed and very high memory bandwidth. The radiative transfer model is very suitable for the GPU implementation to take advantage of the hardware's efficiency and parallelism where radiances of many channels can be calculated in parallel in GPUs. In this paper, we develop a GPU-based high-performance radiative transfer model for the Infrared Atmospheric Sounding Interferometer (IASI) launched in 2006 onboard the first European meteorological polar-orbiting satellites, METOP-A. Each IASI spectrum has 8461 spectral channels. The IASI radiative transfer model consists of three modules. The first module for computing the regression predictors takes less than 0.004% of CPU time, while the second module for transmittance computation and the third module for radiance computation take approximately 92.5% and 7.5%, respectively. Our GPU-based IASI radiative transfer model is developed to run on a low-cost personal supercomputer with four GPUs with total 960 compute cores, delivering near 4 TFlops theoretical peak performance. By massively parallelizing the second and third modules, we reached 364x speedup for 1 GPU and 1455x speedup for all 4 GPUs, both with respect to the original CPU-based single-threaded Fortran code with the -O{sub 2} compiling optimization. The significant 1455x speedup using a computer with four GPUs means that the proposed GPU-based high-performance forward model is able to compute one day's amount of 1,296,000 IASI spectra within nearly 10 min, whereas the original single CPU-based version will impractically take more than 10 days. This model runs over 80% of the theoretical memory bandwidth with asynchronous data transfer. A novel CPU-GPU pipeline implementation of the IASI radiative transfer model is proposed. The GPU-based high-performance IASI radiative transfer model is suitable for the assimilation of the IASI radiance observations into the operational numerical weather forecast model.

97 MATHEMATICS AND COMPUTING↗

A metal-ceramic coaxial cable with multipoint Fabry-Pérot interferometers for monitoring distributed high temperature

A metal ceramic coaxial cable (MCCC) sensor containing multiple Fabry-Pérot interferometers (FPIs) has been designed, fabricated, and evaluated for measuring distributed high temperatures. The MCCC sensor demonstrated here consists of stainless steel tube and wire conductors, alumina tube insulator, and three pairs of air gap reflectors distributed along the cable. The multipoint sensor operation is realized by the joint time-frequency domain technique, which combines the functions of time-domain reflectometry and frequency division multiplexing to enable the measurement of spatially distributed temperature. The 3-point MCCC-FPI sensor has been demonstrated for distributed temperature measurements between 250 and 550 °C and operability up to 1000 °C. The sensor offers high sensitivity of >0.18 MHz/°C with a measurement resolution of 1 Hz and reasonably small high temperature measurement error range of ±3 °C.

42 ENGINEERING↗

A metal-ceramic coaxial cable Fabry-Pérot microwave interferometer for monitoring fluid dielectric constant

We report a metal-ceramic coaxial cable Fabry-Pérot interferometer (MCCC-FPI) has been developed as a new microwave sensor and demonstrated for fast and reliably measuring and continuously monitoring dielectric constants for pure and mixed liquids. The sensor only requires a simple reference scan of the interferogram for the FPI with its sensing chamber filled with air or under vacuum to determine the actual inter-reflector length. The sensor is validated by measuring room temperature dielectric constant (εr) at high frequencies around 1.4–4.7 GHz for three vegetable oils (corn, sesame, and olive), the synthetic Mobil ® -1 engine oil, and mixtures containing sesame oil and water. The sensor has been also successfully demonstrated for determining εr values for the Mobil-1 oil at various temperatures and for the well-dispersed sesame oil-water mixtures of different compositions. The Bottcher’s model of effective medium theory is shown to be better suited for predicting the ε r of the sesame oil-water mixture than the Maxwell-Garnett and Bruggeman equations of spherical solutions.

47 OTHER INSTRUMENTATION↗

Multiplexable intrinsic Fabry-Pérot interferometers inscribed by femtosecond laser for vibration measurement in high temperature environments

This article reports fabrication technique and demodulation algorithm developments to use multiplexable intrinsic Fabry-Pérot interferometer (IFPI) fiber sensor array for distributed vibration measurements at high temperatures. Using femtosecond laser direct writing scheme, IFPI array were fabricated through laser-induced Type II scattering points in single mode fiber cores. Reflection spectra of IFPI array were demodulated in real-time using modified Bunemen frequency analysis. The demodulation algorithm, which was implemented using a photodetector-array spectrometer, achieves 64-nε dynamic strain resolution at 1-kHz spectral acquisition rate and 2-kHz maximum vibration bandwidth. Performance and stabilities of IFPI sensor array were characterized from room temperatures to 800 °C. The static strain resolution was 0.6 με and the minimum detectable dynamic strain amplitude was 23 nε/√Hz at 800 °C. The multiplex performance was also tested by measuring dynamic strain in time domain through six IFPI sensor array fabricated in one fiber. This paper presents an integrated and low-cost sensing solution to perform distributed vibration measurements in harsh environments.

42 ENGINEERING↗

The implementation and data analysis of an interferometer for intense short pulse laser experiments

We present an interferometry setup and the detailed fringe analysis method for intense short pulse (SP) laser experiments. The interferometry scheme was refined through multiple campaigns to investigate the effects of pre-plasmas on energetic electrons at the Jupiter Laser Facility at Lawrence Livermore National Laboratory. The interferometer used a frequency doubled ( ${\it\lambda}=0.527~{\rm\mu}\text{m}$ ) 0.5 ps long optical probe beam to measure the pre-plasma density, an invaluable parameter to better understand how varying pre-plasma conditions affect the characteristics of the energetic electrons. The hardware of the diagnostic, data analysis and example data are presented. Here, the diagnostic setup and the analysis procedure can be employed for any other SP laser experiments and interferograms, respectively.

42 ENGINEERING↗

Electron density and temperature measurement of an atmospheric pressure plasma by millimeter wave interferometer

In this paper, a 105 GHz millimeter wave interferometer system is used to measure the electron density and temperature of an atmospheric pressure helium plasma driven by submicrosecond pulses. The peak electron density and electron-neutral collision frequency reach 8x10{sup 12} cm{sup -3} and 2.1x10{sup 12} s{sup -1}, respectively. According to the electron-helium collision cross section and the measured electron-neutral collision frequency, the electron temperature of the plasma is estimated to reach a peak value of about 8.7 eV.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compact high-speed high-sensitivity second-harmonic interferometer for electron density measurement

A second-harmonic interferometer based on a CW Nd:YAG laser is presented. The device is extremely compact and versatile and is developed for line-integrated electron density measurements in large plasma machines. A sensitivity in measuring line-integrated electron density of 4x10{sup 13} cm{sup -2} with time resolution of 8 {mu}s, and 10{sup 13} cm{sup -2} with time resolution of 50 {mu}s, is demonstrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Interferometer As An Optical Mixer: A Novel Approach To Far Infrared Spectroscopy

In Tokamaks, the Electron Cyclotron Emission (ECE) radiation frequency spans from 80 GHz up to 1 THz for high magnetic field (Bt>5 T) and higher harmonics (n>2). This frequency ranges between Microwaves and Far Infrared (FIR), moulding an intrinsically hybrid nature for ECE diagnostics{sup (1)}. Signal detection is carried out in two surprisingly different ways: electronics and optics. The two detection methods, beyond the chief external differences, are conceptually the same. The dualism often reflects the mindset of the laboratory performing the measurement. In this paper we discuss a different approach to an integrated instrument. A traditional quasi-optical interferometer is the first down-conversion stage with intrinsic broad band capability. Its output signal can then be analysed with a radio-style detection, in the amenable kHz frequency range.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and implementation of a 120 GHz tracking interferometer with near diffraction limited focal spot

The design and implementation of a 120 GHz monostatic tracking interferometer with near diffraction limited focal spot size, used to measure line-averaged plasma density in the source of a plasma opening switch (POS), is described. Physical dimensions of the switch source place an upper limit on the focal spot size. Focusing quasioptics utilize a standard pyramidal horn and a pair of cylindrical lenses that are easily fabricated. The combination of the two cylindrical lenses transforms the asymmetric and approximately Gaussian beam produced by the pyramidal horn into a small focal spot. The circuit utilizes a tracking receiver configuration to track oscillator frequency drifts, which allow for full heterodyne quadrature operation, while avoiding the added complexity of phase or frequency locking of the sources. In order to reduce system noise in the POS pulsed power environment, all sources and amplifiers are battery powered and other noise-reducing techniques are employed. Finally, an improved Gaussian optics design methodology, which tracks the phase center of the Gaussian beam, is proposed. While not critical to this application, this method may yield improvements in systems with short focal lengths.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interferometer density measurements of a high-velocity plasmoid

The plasmoid produced by a half-scale contoured gap coaxial plasma accelerator using ablative polyethylene capillary plasma injectors is measured using a quadrature heterodyne HeNe interferometer. The plasmoid is found to have a sharp rise in density at the leading edge, with a gradual falloff after the peak density. For this early test series, an average bulk density of 5x10{sup 14} cm{sup -3} is observed, with densities up to 8x10{sup 14} cm{sup -3} seen on some shots. Although plasmoid mass is only about 58 mug due to the low current and injected mass used in these tests, good shot-to-shot repeatability is attained making analysis relatively straightforward, thus providing a solid foundation for interpreting future experimental results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multicomponent wavefield characterization with a novel scanning laser interferometer

The in-plane component of the wavefield provides valuable information about media properties from seismology to nondestructive testing. A new compact scanning laser ultrasonic interferometer collects light scattered away from the angle of incidence to provide the absolute ultrasonic displacement for both the out-of-plane and an in-plane components. This new system is tested by measuring the radial and vertical polarization of a Rayleigh wave in an aluminum half-space. The estimated amplitude ratio of the horizontal and vertical displacement agrees well with the theoretical value. The phase difference exhibits a small bias between the two components due to a slightly different frequency response between the two processing channels of the prototype electronic circuitry.

36 MATERIALS SCIENCE↗

High-Speed X-ray Phase Imaging with Grating Interferometer and White Synchrotron Light

Taking advantage of the fact that an X-ray Talbot interferometer functions with X-rays of a broad energy band width, high-speed X-ray phase imaging and tomography have been achieved by using white synchrotron light. An X-ray phase tomogram could be measured with a 0.25 s exposure. Furthermore, a series of X-ray phase tomograms, in other words, a four-dimensional X-ray phase tomogram, could be reconstructed with a tomogram frame rate of 25.5 fps. This achievement advances X-ray phase imaging/tomography from a technique for static imaging to one for dynamic imaging of weakly absorbing objects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design of far-infrared three-wave polarimeter-interferometer system for the J-TEXT tokamak

A multichannel three-wave far-infrared polarimeter-interferometer will be constructed on the J-TEXT tokamak (R=1.05 m, a=0.27 m, B{sub T}{<=}3 T, and I{sub P}{<=}350 kA) for current density profile and electron density profile measurements. The system will adopt the three-wave polarimeter configuration which was first introduced on RTP. Three 432.5 {mu}m HCOOH lasers pumped by three CO{sub 2} lasers separately will be adopted, which could generate high output power, nearly 50 mW at each cavity. Two of them will be counter-rotating circularly polarized to probe the Faraday angle, while the third laser will be used as a local oscillator to get the phase shift caused by electron density. Excellent port access (600x76 mm{sup 2}) and high laser power would promise a profile measurement across the whole plasma section with good signal quality. A high-speed digital phase comparator with a few ({approx}2) {mu}s temporal resolution will be developed, so that fast changes of current or density profile could be measured. Six channels will be installed in the first stage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Recent developments of the JET far-infrared interferometer-polarimeter diagnostic

The far-infrared diagnostic provides essential internal measurements of the plasma density and magnetic field topology (q-profile via Faraday rotation angle) in real-time. The diagnostic capabilities have recently been extended in a number of key areas. Fast interferometer data, with 10 {mu}s time resolution, and a new MATLAB code have allowed improved analysis of the evolution of density profiles during fast events such as vertical plasma displacements, edge localized mode, pellet fuelling, and disruptions. Using the polarimeter measurements in real-time, a new calibration procedure has been developed based on a propagation code using the Mueller matrix formalism. A further major upgrade of the system is presently underway: adding a second color laser to the vertical channels and implementing a new phase counter based on analog zero crossing and field-programmable gate array boards.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗