Search NASA⌕ Search

SEARCH · Search NASA

Results for “Imaging & optical processing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Meniscus Imaging for Crystal-Growth Control

Silicon crystal growth monitored by new video system reduces operator stress and improves conditions for observation and control of growing process. System optics produce greater magnification vertically than horizontally, so entire meniscus and melt is viewed with high resolution in both width and height dimensions.

Sachs, E. M.↗

The Focusing Optics X-Ray Solar Imager: FOXSI

The Focusing Optics x-ray Solar Imager (FOXSI) is a sounding rocket payload funded under the NASA Low Cost Access to Space program to test hard x-ray (HXR) focusing optics and position-sensitive solid state detectors for solar observations. Today's leading solar HXR instrument, the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI) provides excellent spatial (2 arcseconds) and spectral (1 keV) resolution. Yet, due to its use of an indirect imaging system, the derived images have a low dynamic range (typically <10) and sensitivity. These limitations make it difficult to study faint x-ray sources in the solar corona which are crucial for understanding the particle acceleration processes which occur there. Grazing-incidence x-ray focusing optics combined with position-sensitive solid state detectors can overcome both of these limitations enabling the next breakthrough in understanding impulsive energy release on the Sun. The FOXSI project is led by the Space Sciences Laboratory at the University of California, Berkeley. The NASA Marshall Space Flight Center is responsible for the grazing-incidence optics, while the Astro-H team at JAXA/ISAS has provided double-sided silicon strip detectors. FOXSI is a pathfinder for the next generation of solar hard x-ray spectroscopic imagers. Such observatories will be able to image the non-thermal electrons within the solar flare acceleration region, trace their paths through the corona, and provide essential quantitative measurements such as energy spectra, density, and energy content in accelerated electrons.

Krucker, Saem↗

Detecting keyhole porosity and monitoring process signatures in additive manufacturing: an in situ pyrometry and ex situ X-ray radiography correlation

Creation of pores and defects during laser powder bed fusion (LPBF) can lead to poor mechanical properties and thus must be minimized. Post-build inspection is required to ensure the printed parts contain acceptably low defect concentrations. These inspections are time consuming and costly, especially for large or complex parts. As a potential solution, in situ process monitoring can be used to detect the creation of defects, characterize local material behavior and predict expected component properties. However, the precise relationship between pore creation and in situ process monitoring still needs to be understood. In this work, high-speed infrared diode-based pyrometry and high-speed optical imaging signals were used to monitor LPBF printing of 446 stainless steel 316 L single tracks with varying laser power and velocity. Results indicate an increase in pyrometer signal and melt pool dimensions with increasing laser power and decreasing velocity in agreement with previous work. In addition, careful analysis of pyrometer signal reveals a distinct signature of the conduction-to-keyhole mode transition which was confirmed by metallography. Critically, pore defect initiation as characterized by ex situ X-ray radiography was correlated with in situ thermal monitoring signals to derive the probability of defect creation. Our results show that, in principle, a probabilistic prediction of pore formation can be achieved based on in situ high-speed pyrometry monitoring of the LPBF melt pool.

36 MATERIALS SCIENCE↗

Laser beam pointing stabilization using analog position-sensitive diodes

Laser wire scanners have been used for ion beam profile and emittance measurements at the Spallation Neutron Source linear accelerator. Due to propagation distances exceeding 100 m, reliable measurements require laser beam stabilization, previously accomplished with a feedback control loop using a digital camera as a position sensor [Hardin et al., Opt. Express 19, 2874 (2011)]. Here, this paper presents an upgraded pointing stabilization system utilizing analog position-sensitive diodes (PSDs) as the position detector, optimized with an optical diffuser. The new system significantly surpasses the previous system by offering an order-of-magnitude improvement in radiation tolerance and a bandwidth limited only by the burst repetition rate of the laser beam. Operating with a 60-Hz burst mode laser, the new system effectively suppresses laser beam drifts up to 30 Hz, compared to the previous system’s 4 Hz limit. In addition, the amplitude of spectral components below 0.1 Hz was reduced by a factor of more than 100, which is over seven times greater than was achieved by the previous system.

Data acquisition↗

Quantitative optical scanning tests of complex microcircuits

An approach for the development of the optical scanner as a screening inspection instrument for microcircuits involves comparing the quantitative differences in photoresponse images and then correlating them with electrical parameter differences in test devices. The existing optical scanner was modified so that the photoresponse data could be recorded and subsequently digitized. A method was devised for applying digital image processing techniques to the digitized photoresponse data in order to quantitatively compare the data. Electrical tests were performed and photoresponse images were recorded before and following life test intervals on two groups of test devices. Correlations were made between differences or changes in the electrical parameters of the test devices.

Erickson, J. J.↗

X-ray diffraction imaging (topography) of electroopticcrystals by synchrotron radiation

Information of special interest to crystal growers and device physicists now available from monochromatic synchrotron diffraction imaging (topography) is reviewed. Illustrations are taken from a variety of electro-optic crystals. Aspects of the detailed understanding of crystal growth processes obtainable from carefully selected samples are described. Finally, new experimental opportunities now available for exploitation are indicated.

Steiner, Bruce↗

An imaging vector magnetograph for the next solar maximum

Researchers describe the conceptual design of a new imaging vector magnetograph currently being constructed at the University of Hawaii. The instrument combines a modest solar telescope with a rotating quarter-wave plate, an acousto-optical tunable prefilter as a blocker for a servo-controlled Fabry-Perot etalon, CCD cameras, and on-line digital image processing. Its high spatial resolution (1/2 arcsec pixel size) over a large field of view (5 by 5 arcmin) will be sufficient to significantly measure, for the first time, the magnetic energy dissipated in major solar flares. Its millisecond tunability and wide spectral range (5000 to 7000 A) enable nearly simultaneous vector magnetic field measurements in the gas-pressure-dominated photosphere and magnetically-dominated chromosphere, as well as effective co-alignment with Solar-A's X ray images. Researchers expect to have the instrument in operation at Mees Solar Observatory (Haleakala) in early 1991. They have chosen to use tunable filters as wavelength-selection elements in order to emphasize the spatial relationships between magnetic field elements, and to permit construction of a compact, efficient instrument. This means that spectral information must be obtained from sequences of images, which can cause line profile distortions due to effects of atmospheric seeing.

Mickey, D. L.↗

The ROSAT Deep Survey: Optical Identification, Photometry and Spectra of X-Ray Sources in the Lockman Field - 2

The ROSAT Deep Survey includes a complete sample of 50 X-ray sources with fluxes in the 0.5 - 2 keV band larger than 5.5 x 10(exp -15)erg/sq cm/s in the Lockman field (Hasinger et al., Paper 1). We have obtained deep broad-band CCD images of the field and spectra of many optical objects near the positions of the X-ray sources. We define systematically the process leading to the optical identifications of the X-ray sources. For this purpose, we introduce five identification (ID) classes that characterize the process in each case. Among the 50 X-ray sources, we identify 39 AGNs, 3 groups of galaxies, 1 galaxy and 3 galactic stars. Four X-ray sources remain unidentified so far; two of these objects may have an unusually large ratio of X-ray to optical flux.

Schmidt, M.↗

BOREAS RSS-18 Level-1B AVIRIS Imagery: At-Sensor Radiance in BIL Format

These data were collected and processed by the BOREAS RSS-18 team at NASA JPL. Data were acquired for BOREAS with NASA's AVIRIS. This optical sensor measures images that consist of spectra from 400 to 2500 nm at 10-nm sampling. These spectra are acquired as images with 20-meter spatial resolution, 11-km swath width and up to 800-km length. The measurements are spectrally, radiometrically, and geometrically calibrated. Spatially, the data are focused on the BOREAS NSA and SSA near Thompson, Manitoba, and Candle Lake, Saskatchewan, Canada, respectively. AVIRIS data were collected in 1994 during the Thaw campaign at the NSA and SSA, at the SSA in IFC-1, and at the NSA and SSA in both IFC-2 and IFC-3. In 1996, AVIRIS was deployed in the winter and summer campaigns in the SSA only. The data files are available on a CD-ROM (see document number 20010000884) or from the Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC).

Newcomer, Jeffrey A.↗

Polarimetric Hyperspectral Imaging

JPL developed a prototype system for evaluating potential applications of a polarimetric hyperspectral imaging (PHI) technology using the noncollinear acousto-optic tunable filter (AOTF).

polarimetric hyperspectral imaging (PHI) noncollin↗

Raytracing the long trace profiler

The optical design of the Long Trace Profiler optical system is explored with a commercial raytrace program, Zemax OpticStudio™ (ZOS)1, with the intent of finding and correcting sources of systematic error. ZOS provides both geometric raytracing tools and physical optics Gaussian beam propagation and diffraction image calculation tools, and two design modes, sequential component (SC) and non-sequential component (NSC) that are optimized for different aspects of the design process. The original LTP-II system employs a singlet lens with a 1250 mm focal length. It is optimized to provide minimum distortion over a surface slope angle range of ±5 mrad. Using the ZOS tools, we are able to simulate ghost rays that produce distortion in the beam spot image and can minimize the distortion by deliberate misalignment of the beamsplitter (BS) components. Unfortunately, the reference beam is compromised because of the component tilts. The most recent LTP500 system design simplifies the optical system and makes the reference beam usable again, even with misalignment of the polarizing beamsplitter (PBS). Two lenses are designed for the LTP500 - a cemented doublet that has been fabricated, and a singlet with one aspheric surface. Both have focal distances of 500 mm with an expanded angular measurement range of ±10 mrad. The aspheric singlet provides superior performance. ZOS allows the import of wavefront measurement data produced by commercial interferometer software. We apply the wavefront error measurement from the cemented doublet to the model to show that the 19nm RMS wavefront error needs to be improved by at least a factor of ten in order to reduce the systematic error to a level that will allow the LTP to approach its design limit of a few tens of nanoradians.

Takacs, Peter Z.↗

Optics-Free Chip-Scale Intraoperative Imaging Using NIR-Excited Upconverting Nanoparticles

Here we present an optics-free CMOS image sensor that incorporates a novel time-gated dual-photodiode pixel design to allow filter- and lens-less image acquisition of near-infrared-excited (NIR-excited) upconverting nanoparticles. Recent biomedical advances have highlighted the benefits of NIR excitation, but NIR interaction with silicon has remained a challenge, even with high-performance optical blocking filters. Using a secondary diode and a dual-photodiode design, this sensor is able to remove the 100s of mV of NIR background on pixels and bring it down to single-digit mV level, nearing its noise floor of 2.2 mV rms, not achievable with any optical filter. Non-linear effects of background cancellation using the diode pair has been mitigated using an initial one-time pixel-level curve fitting and calibration in a post-processing setting. This imager comprises a highly linear 11 fF metal-oxide-metal (MOM) capacitor and includes integrated angle-selective gratings to reject oblique light and enhance sharpness. Each pixel also includes two distinct correlated double sampling schemes, to remove low frequency flicker noise and systematic offset in the datapath. We demonstrate the performance of this imager using pulsed NIR-excited upconverting nanoparticles on standard United-States-Air-Force (USAF) resolution targets and achieve an SNR of 15 dB, while keeping NIR background below 6 mV. This 36-by-80-pixel array measures only 2.3 mm by 4.8 mm and can be thinned down to 25 µm, allowing it to become surgically compatible with intraoperative instruments and equipment, while remaining optics-free.

42 ENGINEERING↗

Electronic photography at NASA Langley Research Center

The field of photography began a metamorphosis several years ago which promises to fundamentally change how images are captured, transmitted, and output. At this time the metamorphosis is still in the early stages, but already new processes, hardware, and software are allowing many individuals and organizations to explore the entry of imaging into the information revolution. Exploration at this time is prerequisite to leading expertise in the future, and a number of branches at LaRC have ventured into electronic and digital imaging. Their progress until recently has been limited by two factors: the lack of an integrated approach and the lack of an electronic photographic capability. The purpose of the research conducted was to address these two items. In some respects, the lack of electronic photographs has prevented application of an integrated imaging approach. Since everything could not be electronic, the tendency was to work with hard copy. Over the summer, the Photographics Section has set up an Electronic Photography Laboratory. This laboratory now has the capability to scan film images, process the images, and output the images in a variety of forms. Future plans also include electronic capture capability. The current forms of image processing available include sharpening, noise reduction, dust removal, tone correction, color balancing, image editing, cropping, electronic separations, and halftoning. Output choices include customer specified electronic file formats which can be output on magnetic or optical disks or over the network, 4400 line photographic quality prints and transparencies to 8.5 by 11 inches, and 8000 line film negatives and transparencies to 4 by 5 inches. The problem of integrated imaging involves a number of branches at LaRC including Visual Imaging, Research Printing and Publishing, Data Visualization and Animation, Advanced Computing, and various research groups. These units must work together to develop common approaches to image processing and archiving. The ultimate goal is to be able to search for images using an on-line database and image catalog. These images could then be retrieved over the network as needed, along with information on the acquisition and processing prior to storage. For this goal to be realized, a number of standard processing protocols must be developed to allow the classification of images into categories. Standard series of processing algorithms can then be applied to each category (although many of these may be adaptive between images). Since the archived image files would be standardized, it should also be possible to develop standard output processing protocols for a number of output devices. If LaRC continues the research effort begun this summer, it may be one of the first organizations to develop an integrated approach to imaging. As such, it could serve as a model for other organizations in government and the private sector.

Holm, Jack M.↗

Acousto-Optic Imaging Spectrometers for Mars Surface Science

NASA's long term plan for Mars sample collection and return requires a highly streamlined approach for spectrally characterizing a landing site, documenting the mineralogical make-up of the site and guiding the collections of samples which represent the diversity of the site. Ideally, image data should be acquired at hundreds of VIS and IR wavelengths, in order to separately distinguish numerous anticipated species, using principal component analysis and linear unmixing. Cameras with bore-sighted point spectrometers can acquire spectra of isolated scene elements, but it requires 10(exp 2) to 10(exp 2) successive motions and precise relative pointing knowledge in order to create a single data cube which qualifies as a spectral map. These and other competing science objectives have to be accomplished within very short lander/rover operational lifetime (a few sols). True, 2-D imaging spectroscopy greatly speeds up the data acquisition process, since the spectra of all pixels in the scene are collected at once. This task can be accomplished with cameras that use electronically tunable acousto-optic tunable filters (AOTFs) as the optical tuning element. AOTFs made from TeO2 are now a mature technology, and operate at wavelengths from near-UV to about 5 microns. Because of incremental improvements in the last few years, present generation devices are rugged, radiation-hard and operate at temperatures down to at least 150K so they can be safely integrated into the ambient temperature optics of in-situ instruments such as planetary or small-body landers. They have been used for ground-based astronomy, and were also baselined for the ST-4 Champollion IR comet lander experiment (CIRCLE), prior to cancellation of the ST-4 mission last year. AIMS (for Acousto-optic Imaging spectrometer), is a prototype lander instrument which is being built at GSFC with support by the NASA OSS Advanced Technologies and Mission Studies, Mars Instrument Definition and Development Program (MIDP). AIMS is capable of tunable spectroscopic imaging of surface mineralogy, ices and dust between 0.5 and 2.4 microns, at a resolving power (lambda/delta lambda) which is typically several hundred. The design spatial resolution, similar to IMP and SSI, will allow mapping at scales down to about 1 cm.

Glenar, D. A.↗

Synthetic aperture radar imaging using acousto-optics and charge-coupled devices

The operating principles of an acoustooptic/CCD real-time SAR processor are described, and experimental results are presented. Particular consideration is given to time-and-space integrating processing, the range processor, and the azimuth processor. The interferometric detection scheme is examined in detail.

Psaltis, D.↗

Lightning and Other Influences On Tropical Tropospheric Ozone: Empirical Studies of Covariation

Tropical and subtropical tropospheric ozone are important radiatively active species, with particularly large effects in the upper third of the troposphere. Temporal variability of O3 has proved difficult to simulate day by day in process models. Thus, individual roles of lightning, biomass burning, and other pollution in providing precursor NO(x), radicals, and chain carriers (CO, hydrocarbons) remain unquantified by simulation, and it is theoretically reasonable that individual roles are magnified by a joint synergy. We use wavelet analysis and Burg-algorithm maximum entropy spectral analyses to describe time-scales and correlation of ozone with proxies for processes controlling its concentration. Our empirical studies link time variations apparent in several datasets: the SHADOZ (Southern Hemisphere Additional Ozonesondes) network stations (Nairobi, Fiji), and auxiliary series with power to explain ozone-determining processes, with some interpretation based on the TTO (Tropical Tropospheric Ozone) product derived from TOMS (the Total Ozone Mapping Spectrometer). The auxiliary series are The OTD/LIS(Optical Transient Detector/Lightning Imaging Sensor) measurements of the lightning NO(x) source, the OLR (Outgoing Longwave Radiation)measurement of high-topped clouds, and standard meteorological variables from the United States NCEP (National Centers for Environmental Prediction) and Data Assimilation Office analyses. Concentrating on equatorial ozone, we compare the statistical evidence on the variability of tropospheric ozone. Important variations occur on approximately two-week, two-month (Madden-Julian Oscillation) and annual scales, and relations with OLR suggest controls associated with continental clouds. Hence we are now using the Lightning Imaging Sensor data set to indicate NO(x) sources. We report initial results defining relative roles of the process mentioned affecting O3 using their covariance properties.

Chatfield, Robert B.↗

Method of acquiring an image from an optical structure having pixels with dedicated readout circuits

An imaging device formed as a monolithic complementary metal oxide semiconductor integrated circuit in an industry standard complementary metal oxide semiconductor process, the integrated circuit including a focal plane array of pixel cells, each one of the cells including a photogate overlying the substrate for accumulating photo-generated charge in an underlying portion of the substrate, a readout circuit including at least an output field effect transistor formed in the substrate, and a charge coupled device section formed on the substrate adjacent the photogate having a sensing node connected to the output transistor and at least one charge coupled device stage for transferring charge from the underlying portion of the substrate to the sensing node.

Fossum, Eric R.↗