Search NASA⌕ Search

SEARCH · Search NASA

Results for “InSPIRE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

OFDM inspired waveforms for 5G

As the standardization activities are being formed to lay the foundation of 5G wireless networks, there is a common consensus on the need to replace the celebrated OFDM by a more effective air interface that better serves the challenging needs of 5G. The main reason that has made OFDM popular in the past is related to the fact that information symbols are carried over a number of pure tones/sinusoidal signals. Moreover, with the use of cyclic prefix (CP), it is assured that the information carrying tones are only affected by the channel (complex) gains at the respective frequencies. Accordingly, the channel effect can be trivially compensated for (equalized) in the frequency domain through a single complex tap per subcarrier. However, as network air interfaces become more complex and the demand for multiuser services grows, OFDM is found to be incapable of handling the inevitable loss of synchronization among users. In the recent past, two novel waveforms (namely, GFDM and C-FBMC) have been discussed in the literature to overcome this and other drawbacks of OFDM. Interestingly, and at the same time not surprising, these methods share a common fundamental property with OFDM: each data packet is made up of a number of tones that are modulated by information symbols. In this tutorial article, we build a common framework based on the said OFDM principle and derive GFDM and C-FBMC waveforms from this point of view. This derivation provides a new prospective that facilitates straightforward understanding of channel equalization and the application of these new waveforms to MIMO channels. As a result, it also facilitates derivation of new structures for more efficient synthesis/analysis of these waveforms than those that have been reported in the literature.

99 GENERAL AND MISCELLANEOUS↗

A New Shape Optimization Approach for Lightweighting Electric Machines Inspired by Additive Manufacturing

Minimizing the mass in electric machines while maintaining superior performance is a new requirement for the advancement of drivetrains used in wind energy and electric mobility. Topology optimization (TO) for lightweighting electric machines using traditional approaches typically explores a restricted design space allowed by standard parametrizable geometry and manufacturing, while advanced methods, such as cell-based density approaches, suffer from a lack of robust manufacturability constraints during the optimization process. To overcome these drawbacks, we explore a grid-independent, boundary optimization where the outer shape of the magnet is parameterized using Bezier curves. We conduct a design of experiments (DOE) to study the effect of different magnet shapes on machine performance by varying the control points on the Bezier curves. A machine-learning-based surrogate model is constructed using the data from the DOE to quantify the relationship between the control points, air-gap torque, and mass. The control points are then optimized to maximize the torque density. The approach is used for minimizing electrical steel mass in the International Energy Agency (IEA) 15-MW radial flux direct-drive wind turbine generator. The new approach to shape optimization resulted in smooth and concise shapes that can be easily additively manufactured with up to a 20-ton reduction in electrical steel mass.

additive manufacturing↗

A Generalized Bio-inspired Method for Discovering Sequence-based Signatures

Many phenomena that we wish to discover are comprised of sequences of events or event primitives. Often signatures are constructed to identify such phenomena using either distributions or frequencies of attributes, or specific subsequences that are known to correlate to the phenomena. Distribution-based identification does not capture the essence of the sequence of behaviors and therefore may suffer from lack of specificity. At the other extreme, using specific subsequences to identify target phenomena is often too specific and suffers from lower sensitivity when natural variations arise in the phenomena, measuring process, or data analysis. We introduce here a method for discovering signatures for phenomena that are well characterized by sequences of event primitives. In this paper, we describe the steps taken and lessons learned in generalizing a sequence analysis method, BLAST, for use on non-biological datasets including expressing and operating on alphabets of varying length, constructing a reward/penalty model for arbitrary datasets, and discovering low complexity segments in sequence data by extending BLAST’s native low-complexity estimating algorithms. We also present several case studies that demonstrate the utility of this method to discovering signatures in a wide array of applications including network traffic, software analysis, server characterization, and others. Finally, we demonstrate how signatures discovered using this method can be expressed using a variety of model formalisms, each having its own relative benefit.

Signature Science↗

LINEBACkER: Bio-inspired Data Reduction Toward Real Time Network Traffic Analysis

Abstract—One essential component of resilient cyber applications is the ability to detect adversaries and protect systems with the same flexibility adversaries will use to achieve their goals. Current detection techniques do not enable this degree of flexibility because most existing applications are built using exact or regular-expression matching to libraries of rule sets. Further, network traffic defies traditional cyber security approaches that focus on limiting access based on the use of passwords and examination of lists of installed or downloaded programs. These approaches do not readily apply to network traffic occurring beyond the access control point, and when the data in question are combined control and payload data of ever increasing speed and volume. Manual analysis of network traffic is not normally possible because of the magnitude of the data that is being exchanged and the length of time that this analysis takes. At the same time, using an exact matching scheme to identify malicious traffic in real time often fails because the lists against which such searches must operate grow too large. In this work, we introduce an alternative method for cyber network detection based on similarity-measuring algorithms for gene sequence analysis. These methods are ideal because they were designed to identify similar but nonidentical sequences. We demonstrate that our method is generally applicable to the problem of network traffic analysis by illustrating its use in two different areas both based on different attributes of network traffic. Our approach provides a logical framework for organizing large collections of network data, prioritizing traffic of interest to human analysts, and makes it possible to discover traffic signatures without the bias introduced by expert-directed signature generation. Pattern recognition on reduced representations of network traffic offers a fast, efficient, and more robust way to detect anomalies.

Teuton, Jeremy R.↗

Quantum-Inspired Power System Reliability Assessment

To enable an in-depth study of power system operation and planning, the assessment of standard reliability indices is inevitable. The Monte Carlo Simulation (MCS) approach is a broadly used method in replacing the analytical methods in reliability indices assessment. The accuracy of MCS, however, highly depends on the sampling size, and hence, a complicated system with large number of components requires a large sampling size and daunting computational effort. To address this shortcoming, we, in this paper attempt to take advantage of potentials of the quantum computing (QC) for power system reliability assessment by realizing the following contributions: 1) an innovative quantum model designed for reliability assessment; 2) a quantum circuit that achieves the quadratic speed up compared to the classical MCS method; 3) an efficient quantum amplitude estimation (QAE) algorithm to accurately evaluate the reliability indices. The accuracy and efficacy of the quantum reliability method are extensively verified and demonstrated on both radial and mesh distribution systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

RadVolViz: An Information Display-Inspired Transfer Function Editor for Multivariate Volume Visualization

In volume visualization transfer functions are widely used for mapping voxel properties to color and opacity. Typically, volume density data are scalars which require simple 1D transfer functions to achieve this mapping. If the volume densities are vectors of three channels, one can straightforwardly map each channel to either red, green or blue, which requires a trivial extension of the 1D transfer function editor. Here, we devise a new method that applies to volume data with more than three channels. These types of data often arise in scientific scanning applications, where the data are separated into spectral bands or chemical elements. Our method expands on prior work in which a multivariate information display, RadViz, was fused with a radial color map, in order to visualize multi-band 2D images. In this work, we extend this joint interface to blended volume rendering. The information display allows users to recognize the presence and value distribution of the multivariate voxels and the joint volume rendering display visualizes their spatial distribution. We design a set of operators and lenses that allow users to interactively control the mapping of the multivariate voxels to opacity and color. This enables users to isolate or emphasize volumetric structures with desired multivariate properties. Furthermore, it turns out that our method also enables more insightful displays even for RGB data. We demonstrate our method with three datasets obtained from spectral electron microscopy, high energy X-ray scanning, and atmospheric science.

36 MATERIALS SCIENCE↗

SU-F-BRB-02: Towards Quantitative Clinical Decision On Deep Inspiration Breath Hold (DIBH) Or Prone for Left-Sided Breast Irradiation

Purpose: To develop quantitative clinical guidelines between supine Deep Inspiratory Breath Hold (DIBH) and prone free breathing treatments for breast patients, we applied 3D deformable phantoms to perform Monte Carlo simulation to predict corresponding Dose to the Organs at Risk (OARs). Methods: The RPI-adult female phantom (two selected cup sizes: A and D) was used to represent the female patient, and it was simulated using the MCNP6 Monte Carlo code. Doses to OARs were investigated for supine DIBH and prone treatments, considering two breast sizes. The fluence maps of the 6-MV opposed tangential fields were exported. In the Monte Carlo simulation, the fluence maps allow each simulated photon particle to be weighed in the final dose calculation. The relative error of all dose calculations was kept below 5% by simulating 3*10{sup 7} photons for each projection. Results: In terms of dosimetric accuracy, the RPI Adult Female phantom with cup size D in DIBH positioning matched with a DIBH treatment plan of the patient. Based on the simulation results, for cup size D phantom, prone positioning reduced the cardiac dose and the dose to other OARs, while cup size A phantom benefits more from DIBH positioning. Comparing simulation results for cup size A and D phantom, dose to OARs was generally higher for the large breast size due to increased scattering arising from a larger portion of the body in the primary beam. The lower dose that was registered for the heart in the large breast phantom in prone positioning was due to the increase of the distance between the heart and the primary beam when the breast was pendulous. Conclusion: Our 3D deformable phantom appears an excellent tool to predict dose to the OARs for the supine DIBH and prone positions, which might help quantitative clinical decisions. Further investigation will be conducted. National Institutes of Health R01EB015478.

60 APPLIED LIFE SCIENCES↗

SU-F-BRB-03: Quantifying Patient Motion During Deep-Inspiration Breath-Hold Using the ABC System with Simultaneous Surface Photogrammetry

Purpose: Active breathing control (ABC) has been used to reduce treatment margin due to respiratory organ motion by enforcing temporary breath-holds. However, in practice, even if the ABC device indicates constant lung volume during breath-hold, the patient may still exhibit minor chest motion. Consequently, therapists are given a false sense of security that the patient is immobilized. This study aims at quantifying such motion during ABC breath-holds by monitoring the patient chest motion using a surface photogrammetry system, VisionRT. Methods: A female patient with breast cancer was selected to evaluate chest motion during ABC breath-holds. During the entire course of treatment, the patient’s chest surface was monitored by a surface photogrammetry system, VisionRT. Specifically, a user-defined region-of-interest (ROI) on the chest surface was selected for the system to track at a rate of ∼3Hz. The surface motion was estimated by rigid image registration between the current ROI image captured and a reference image. The translational and rotational displacements computed were saved in a log file. Results: A total of 20 fractions of radiation treatment were monitored by VisionRT. After removing noisy data, we obtained chest motion of 79 breath-hold sessions. Mean chest motion in AP direction during breath-holds is 1.31mm with 0.62mm standard deviation. Of the 79 sessions, the patient exhibited motion ranging from 0–1 mm (30 sessions), 1–2 mm (37 sessions), 2–3 mm (11 sessions) and >3 mm (1 session). Conclusion: Contrary to popular assumptions, the patient is not completely still during ABC breath-hold sessions. In this particular case studied, the patient exhibited chest motion over 2mm in 14 out of 79 breath-holds. Underestimating treatment margin for radiation therapy with ABC could reduce treatment effectiveness due to geometric miss or overdose of critical organs. The senior author receives research funding from NIH, VisionRT, Varian Medical Systems and Elekta.

60 APPLIED LIFE SCIENCES↗

SU-F-J-55: Feasibility of Supraclavicular Field Treatment by Investigating Variation of Junction Position Between Breast Tangential and Supraclavicular Fields for Deep Inspiration Breath Hold (DIBH) Left Breast Radiation

Purpose: To explore the feasibility of supraclavicular field treatment by investigating the variation of junction position between tangential and supraclavicular fields during left breast radiation using DIBH technique. Methods: Six patients with left breast cancer treated using DIBH technique were included in this study. AlignRT system was used to track patient’s breast surface. During daily treatment, when the patient’s DIBH reached preset AlignRT tolerance of ±3mm for all principle directions (vertical, longitudinal, and lateral), the remaining longitudinal offset was recorded. The average with standard-deviation and the range of daily longitudinal offset for the entire treatment course were calculated for all six patients (93 fractions totally). The ranges of average ± 1σ and 2σ were calculated, and they represent longitudinal field edge error with the confidence level of 68% and 95%. Based on these longitudinal errors, dose at junction between breast tangential and supraclavicular fields with variable gap/overlap sizes was calculated as a percentage of prescription (on a representative patient treatment plan). Results: The average of longitudinal offset for all patients is 0.16±1.32mm, and the range of longitudinal offset is −2.6 to 2.6mm. The range of longitudinal field edge error at 68% confidence level is −1.48 to 1.16mm, and at 95% confidence level is −2.80 to 2.48mm. With a 5mm and 1mm gap, the junction dose could be as low as 37.5% and 84.9% of prescription dose; with a 5mm and 1mm overlap, the junction dose could be as high as 169.3% and 117.6%. Conclusion: We observed longitudinal field edge error at 95% confidence level is about ±2.5mm, and the junction dose could reach 70% hot/cold between different DIBH. However, over the entire course of treatment, the average junction variation for all patients is within 0.2mm. The results from our study shows it is potentially feasible to treat supraclavicular field with breast tangents.

60 APPLIED LIFE SCIENCES↗

SU-F-T-514: Evaluation of the Accuracy of Free-Breathing and Deep Inspiration Breath-Hold Gated Beam Delivery Using An Elekta Linac

Purpose: In this study, we evaluated the performance of an Elekta linac in the delivery of gated radiotherapy. We examined whether the use of either a short gating window or a long beam hold impacts the accuracy of the delivery Methods: The performance of an Elekta linac in the delivery of gated radiotherapy was assessed using a 20cmX 20cm open field with the radiation delivered using a range of beam-on and beam-off time periods. Two SBRT plans were used to examine the accuracy of gated beam delivery for clinical treatment plans. For the SBRT cases, tests were performed for both free-breathing based gating and for gated delivery with a simulated breath-hold. A MatriXX 2D ion chamber array was used for data collection, and the gating accuracy was evaluated using gamma score. Results: For the 20cmX20cm open field, the gated beam delivery agreed closely with the non-gated delivery results. Discrepancies in the agreement, however, began to appear with a 5-to-1 ratio of the beam-off to beam-on. For these tight gating windows, each beam-on segment delivered a small number of monitor units. This finding was confirmed with dose distribution analysis from the delivery of the two VMAT plans where the gamma score(±1%,2%/1mm) showed passing rates in the range of 95% to 100% for gating windows of 25%, 38%, 50%, 63%, 75%, and 83%. Using a simulated sinusoidal breathing signal with a 4 second period, the gamma score of freebreathing gating and breath-hold gating deliveries were measured in the range of 95.7% to 100%. Conclusion: The results demonstrate that Elekta linacs can be used to accurately deliver respiratory gated treatments for both free-breathing and breath-hold patients. The accuracy of beams delivered in a gated delivery mode at low small MU proved higher than similar deliveries performed in a non-gated (manually interrupted) fashion.

60 APPLIED LIFE SCIENCES↗

Poster – 41: External marker block placement on the breast or chest wall for left-sided deep inspiration breath-hold radiotherapy

Purpose: We investigate DIBH breast radiotherapy using the Real-time Position Management (RPM) system with the marker-block placed on the target breast or chest wall. Methods: We measured surface dose for three different RPM marker-blocks using EBT3 Gafchromic film at 0° and 30° incidence. A registration study was performed to determine the breast surface position that best correlates with overall internal chest wall position. Surface and chest wall contours from MV images of the medial tangent field were extracted for 15 patients. Surface contours were divided into three potential marker-block positions on the breast: Superior, Middle, and Inferior. Translational registration was used to align the partial contours to the first-fraction contour. Each resultant transformation matrix was applied to the chest wall contour, and the minimum distance between the reference chest wall contour and the transformed chest wall contour was evaluated for each pixel. Results: The measured surface dose for the 2-dot, 6-dot, and 4-dot marker-blocks at 0° incidence were 74%, 71%, and 77% of dose to dmax respectively. At 30° beam incidence this increased to 76%, 72%, and 81%. The best external surface position was patient and fraction dependent, with no consistent best choice. Conclusions: The increase in surface dose directly under the RPM block is approximately equivalent to 3 mm of bolus. No marker-block position on the breast surface was found to be more representative of overall chest wall motion; therefore block positional stability and reproducibility can be used to determine optimal placement on the breast or chest wall.

60 APPLIED LIFE SCIENCES↗

Measurement of high-mass $t\bar{t}\ell ^{+}\ell ^{-}$ production and lepton flavour universality-inspired effective field theory interpretations at $\sqrt{s}=13$ $\text {T}\text {e}\hspace{-1.00006pt}\text {V}$ with the ATLAS detector

Measurements of $t\bar{t}\ell ^{+}\ell ^{-}$ production in the region of high dilepton invariant mass with effective field theory (EFT) interpretations are presented. They are performed using final states with three isolated leptons (electrons or muons) and are based on $\sqrt{s} = 13$ TeV proton–proton collision data with an integrated luminosity of $140\,\textrm{fb}^{-1}$, recorded from 2015 to 2018 with the ATLAS detector at the Large Hadron Collider. Measurements of the $t\bar{t}\ell ^{+}\ell ^{-}$ signal strength and cross-section upper-limits are performed inclusively in lepton flavour and separately for electrons and muons. The study also aims to probe anomalous four-fermion interactions including to test for possible lepton flavor universality violation. No significant deviations from the Standard Model predictions are observed and the measurements are interpreted through the EFT formalism to provide new constraints on the relevant operators.

Aad, G. [CNRS/IN2P3] (ORCID:0000000266654934)↗