Parallel sorting algorithm classification: is manual instrumentation necessary?

Understanding parallel algorithms is crucial for accelerating scientific simulations on complex, distributed memory, high-performance computers. Modern algorithm classification approaches learn semantics directly from source code to differentiate between algorithms, however, accessing source code is not always possible. We can learn about parallel algorithms from observing their performance, as programs running the same algorithms and using the same hardware should exhibit similar performance characteristics. We present an approach to learn algorithm classes from parallel performance data directly in order to classify algorithms without access to the source code. We extend previous work to enable classifying parallel sorting algorithms using automatic instrumentation instead of requiring manual region annotations in the source code. In this work, we design and demonstrate a study for classification of parallel sorting algorithms using parallel performance data collected from automatic instrumentation, and evaluate the performance of our new methodology on classification. We leverage Caliper to collect the performance data, Thicket for our exploratory data analysis (EDA), and PyTorch and Scikit-learn to evaluate the effectiveness of random forests, support vector machines (SVMs), decision trees, neural networks, and logistic regressions on parallel performance data. Additionally, we study noise in parallel performance data, whether the removal of noise and pre-processing of the data is necessary to accurately classify parallel sorting algorithms, and determine the effectiveness of features created from performance data. In conclusion, we demonstrate classification accuracy for these five different models of up to 97.7% across four different parallel algorithm classes.

Algorithm Classification↗

Study of hot tearing of A206 aluminum alloy using Instrumented Constrained T-shaped Casting method

The hot tearing susceptibility of A206 aluminum alloy was investigated using Instrumented Constrained T-shaped Casting method and the effect of the casting temperature on hot tearing was studied. The Instrumented Constrained T-shaped Casting apparatus enabled real-time measurements of the contraction load developed in the casting and the temperature variations during solidification as a function of time. Critical temperatures and points during solidification of the castings were extracted from these data. The contraction load developed at the coalescence point of the castings was identified as a comparative criterion for predicting the hot tearing susceptibility of the alloys which could be utilized even when no visual tearing had occurred. The results showed that hot tearing susceptibility increased with the casting temperature. This was associated with reduced cooling rate, increased solute segregation and more localized hot spot formation at the T-junction area. Increase in the casting temperature also increased the grain size which may in turn have affected the initiation of the hot tears. The visual observations were further validated with radiographic tests.

36 MATERIALS SCIENCE↗

Determination of total plutonium content in spent nuclear fuel assemblies with the differential die-away self-interrogation instrument

As a part of the Next Generation Safeguards Initiative Spent Fuel project, we simulate the response of the Differential Die-away Self-Interrogation (DDSI) instrument to determine total elemental plutonium content in an assayed spent nuclear fuel assembly (SFA). We apply recently developed concepts that relate total plutonium mass with SFA multiplication and passive neutron count rate. In this work, the multiplication of the SFA is determined from the die-away time in the early time domain of the Rossi-Alpha distributions measured directly by the DDSI instrument. Here, we utilize MCNP to test the method against 44 pressurized water reactor SFAs from a simulated spent fuel library with a wide dynamic range of characteristic parameters such as initial enrichment, burnup, and cooling time. Under ideal conditions, discounting possible errors of a real world measurement, a root mean square agreement between true and determined total Pu mass of 2.1% is achieved.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optimization of ray-tracing simulations to confirm performance of the GP-SANS instrument at the High-Flux Isotope Reactor

The CG-2 beamline at the High Flux Isotope Reactor (HFIR) exhibits a notable discrepancy between observed count rates and the count rates we would expect based on a Monte-Carlo neutron ray-trace simulation. These simulations consistently predict count rates approximately five times greater than those observed in four separate experimental runs involving different instrument configurations. This discrepancy suggests that certain factors are causing losses in measurements that are not adequately accounted for in the simulation, in particular guide reflectivity or misalignment. To investigate these discrepancies, a high-dimensional simulation parameter approach is applied in order to understand the losses. Region of Interest (ROI) groups along the instrument are assigned to different surfaces of the guide components within the simulation. This allows the parameters of those guide components to be varied as a group to minimize the complexity of the search space. The result is an optimization of simulation parameters using an iterative scheme that aims to minimize the difference between experimentally measured count rates and simulated count rates across all tested collimator combinations. This proposed methodology holds the potential to reveal previously unrecognized sources of intensity loss in the CG-2 beamline at HFIR and improve the accuracy of simulations, leading to enhanced understanding and performance of the beamline for various scientific applications.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Concepts, Instruments, and Model Systems that Enabled the Rapid Evolution of Surface Science

Over the past forty years, surface science has evolved to become both an atomic scale and a molecular scale science. Gerhard Ertl's group has made major contributions in the field of molecular scale surface science, focusing on vacuum studies of adsorption chemistry on single crystal surfaces. In this review, we outline three important aspects which have led to recent advances in surface chemistry: the development of new concepts, in situ instruments for molecular scale surface studies at buried interfaces (solid-gas and solid-liquid), and new model nanoparticle surface systems, in addition to single crystals. Combined molecular beam surface scattering and low energy electron diffraction (LEED)- surface structure studies on metal single crystal surfaces revealed concepts, including adsorbate-induced surface restructuring and the unique activity of defects, atomic steps, and kinks on metal surfaces. We have combined high pressure catalytic reaction studies with ultra high vacuum (UHV) surface characterization techniques using a UHV chamber equipped with a high pressure reaction cell. New instruments, such as high pressure sum frequency generation (SFG) vibrational spectroscopy and scanning tunneling microscopy (STM) which permit molecular-level surface studies have been developed. Tools that access broad ranges of pressures can be used for both the in situ characterization of solid-gas and solid-liquid buried interfaces and the study of catalytic reaction intermediates. The model systems for the study of molecular surface chemistry have evolved from single crystals to nanoparticles in the 1-10 nm size range, which are currently the preferred media in catalytic reaction studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating Cloud Properties at Scott Base: Comparing Ceilometer Observations With ERA5, JRA55, and MERRA2 Reanalyses Using an Instrument Simulator

This study compares CL51 ceilometer observations made at Scott Base, Antarctica, with statistics from the ERA5, JRA55, and MERRA2 reanalyses. To enhance the comparison we use a lidar instrument simulator to derive cloud statistics from the reanalyses which account for instrumental factors. The cloud occurrence in the three reanalyses is slightly overestimated above 3 km, but displays a larger underestimation below 3 km relative to observations. Unlike previous studies, we see no relationship between relative humidity and cloud occurrence biases, suggesting that the cloud biases do not result from the representation of moisture. We also show that the seasonal variation of cloud occurrence and cloud fraction, defined as the vertically integrated cloud occurrence, are small in both the observations and the reanalyses. We also examine the quality of the cloud representation for a set of weather states derived from ERA5 surface winds. The variability associated with grouping cloud occurrence based on weather state is much larger than the seasonal variation, highlighting weather state is a strong control of cloud occurrence. All the reanalyses continue to display underestimates below 3 km and overestimates above 3 km for each weather state. But the variability in ERA5 statistics matches the changes in the observations better than the other reanalyses. We also use a machine learning scheme to estimate the quantity of supercooled liquid water cloud from the ceilometer observations. Ceilometer low-level supercooled liquid water cloud occurrences are considerably larger than values derived from the reanalyses, further highlighting the poor representation of low-level clouds in the reanalyses.

54 ENVIRONMENTAL SCIENCES↗

First inductively coupled plasma-distance-of-flight mass spectrometer: instrument performance with a microchannel plate/phosphor imaging detector

Here we describe the first combination of a Distance-of-Flight Mass Spectrometry (DOFMS) instrument and an inductively coupled plasma (ICP) ion source. DOFMS is a velocity-based MS technique in which ions of a range of mass-to-charge (m/z) values are detected simultaneously along the length of a spatially selective detector. As a relative of time-of-flight (TOF) MS, DOFMS leverages benefits fromboth TOFMS and spatially dispersive MS. The simultaneous detection of groups of m/z values improves dynamic range by spreading ion signal across many detector elements and reduces correlated noise by signal ratioing. To ascertain the performance characteristics of the ICP-DOFMS instrument, we have employed a microchannel-plate/phosphor detection assembly with a scientific CCD to capture images of the phosphor plate. With this simple (and commercially available) detection scheme, elemental detection limits from 2–30 ng L*1 and a linear dynamic range of 5 orders of magnitude (10–106 ng L1) have been demonstrated. Additionally, a competitive isotope-ratio precision of 0.1% RSD has been achieved with only a 6 s signal integration period. In addition to first figures of merit, this paper outlines technical considerations for the design of the ICP-DOFMS.

Gundlach-Graham, Alexander W.↗

Case Study of Expected Seismic Performance of an Instrumented Steel Moment Frame Building

A relevant number of modern welded steel structures suffered unexpected damage during the January 1994 Northridge earthquake. The damage of welded special moment resisting frames (W-SMRJF) typically involved the brittle fracture in the welded girder to column connection areas. In the aftermath of the Northridge earthquake the research and structural engineering communities addressed the issue of the seismic safety of damaged and undamaged W-SMRF's. However, even though seismic design codes in the United States were significantly revised after the Northridge quake, still there are hundreds of existing W-Serf's in the US and in other countries, designed and detailed according to pre-Northridge criteria. This work is a case study on seismic response of a W-SMRF instrumented by the California Strong Motion Instrumentation Program (CSMIP) which was shaken during the 1987 Whittier, 1991 Sierra Madre and 1994 Northridge earthquakes. A detailed finite element model of the structure is developed to analyze the building dynamic response during recorded strong motions. Model accuracy was assessed by comparing prediction of the analytical model with actual CSMIP response records. In order to assess its vulnerability in response to future and possibly stronger earthquakes, nonlinear analyses were conducted subjecting the model to the Newhall and Sylmar records of the 1994 Northridge and to the 1995 Kobe earthquakes. Analysis results show that the structure behaved linearly during these earthquakes. The predicted response to larger and more severe ground motions show that plastic deformation occur at many column ends and inelastic deformation demands exceed the expected capacity of the welded pre-Northridge beam-to-column connections.

58 GEOSCIENCES↗

Photon Activation Analysis Of Light Elements Using 'Non-Gamma' Radiation Spectroscopy - The Instrumental Determination Of Phosphorus

Unlike metal determinations the analysis of light elements (e.g., carbon, oxygen, phosphorus) is frequently problematic, in particular if analysed instrumentally. In photon activation analysis (PAA) the respective activation products do not emit gamma radiation in the most cases. Usually, annihilation quanta counting and subsequent decay curve analysis have been used for determinations of C, N, O, and F. However, radiochemical separation of the respective radioisotopes mostly is indispensable. For several reasons, some of the light elements cannot be analysed following this procedure, e.g. phosphorus. In this contribution the instrumental PAA of phosphorus in organic matrix by activation with bremsstrahlung of an electron linear accelerator and subsequent beta spectroscopy is described. The accuracy of the results was excellent as obtained by analysis of a BCR Reference Material.

07 ISOTOPE AND RADIATION SOURCES↗

Novel Scanning Lens Instrument for Evaluating Fresnel Lens Performance: Equipment Development and Initial Results (Presentation)

A system dedicated to the optical transmittance characterization of Fresnel lenses has been developed at NREL, in collaboration with the UPM. The system quantifies the optical efficiency of the lens by generating a performance map. The shape of the focused spot may also be analyzed to understand change in the lens performance. The primary instrument components (lasers and CCD detector) have been characterized to confirm their capability for performing optical transmittance measurements. Measurements performed on SoG and PMMA lenses subject to a variety of indoor conditions (e.g., UV and damp heat) identified differences in the optical efficiency of the evaluated lenses, demonstrating the ability of the Scanning Lens Instrument (SLI) to distinguish between the aged lenses.

14 SOLAR ENERGY↗

New customizable phased array UT instrument opens door for furthering research and better industrial implementation

Phased array UT as an inspection technique in itself continues to gain wide acceptance. However, there is much room for improvement in terms of implementation of Phased Array (PA) technology for every unique NDT application across several industries (e.g. oil and petroleum, nuclear and power generation, steel manufacturing, etc.). Having full control of the phased array instrument and customizing a software solution is necessary for more seamless and efficient inspections, from setting the PA parameters, collecting data and reporting, to the final analysis. NDT researchers and academics also need a flexible and open platform to be able to control various aspects of the phased array process. A high performance instrument with advanced PA features, faster data rates, a smaller form factor, and capability to adapt to specific applications, will be discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

High intensity multi beam design of SANS instrument for Dhruva reactor

A new and versatile design of Small Angle Neutron Scattering (SANS) instrument based on utilization of multi-beam is presented. The multi-pinholes and multi-slits as SANS collimator for medium flux Dhruva rearctor have been proposed and their designs have been validated using McStas simulations. Various instrument configurations to achieve different minimum wave vector transfers in scattering experiments are envisioned. These options enable smooth access to minimum wave vector transfers as low as ~ 6×10{sup −4} Å{sup −1} with a significant improvement in neutron intensity, allowing faster measurements. Such angularly well defined and intense neutron beam will allow faster SANS studies of agglomerates larger than few tens of nm.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluating musical instruments

Scientific measurements of sound generation and radiation by musical instruments are surprisingly hard to correlate with the subtle and complex judgments of instrumental quality made by expert musicians.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Extraction of mechanical properties of materials through deep learning from instrumented indentation

Instrumented indentation has been developed and widely utilized as one of the most versatile and practical means of extracting mechanical properties of materials. This method is particularly desirable for those applications where it is difficult to experimentally determine the mechanical properties using stress–strain data obtained from coupon specimens. Such applications include material processing and manufacturing of small and large engineering components and structures involving the following: three-dimensional (3D) printing, thin-film and multilayered structures, and integrated manufacturing of materials for coupled mechanical and functional properties. Here, we utilize the latest developments in neural networks, including a multifidelity approach whereby deep-learning algorithms are trained to extract elastoplastic properties of metals and alloys from instrumented indentation results using multiple datasets for desired levels of improved accuracy. We have established algorithms for solving inverse problems by recourse to single, dual, and multiple indentation and demonstrate that these algorithms significantly outperform traditional brute force computations and function-fitting methods. Moreover, we present several multifidelity approaches specifically for solving the inverse indentation problem which 1) significantly reduce the number of high-fidelity datasets required to achieve a given level of accuracy, 2) utilize known physical and scaling laws to improve training efficiency and accuracy, and 3) integrate simulation and experimental data for training disparate datasets to learn and minimize systematic errors. The predictive capabilities and advantages of these multifidelity methods have been assessed by direct comparisons with experimental results for indentation for different commercial alloys, including two wrought aluminum alloys and several 3D printed titanium alloys.

36 MATERIALS SCIENCE↗

VALIDATION OF ANALYTICAL METHODS AND INSTRUMENTATION FOR BERYLLIUM MEASUREMENT: REVIEW AND SUMMARY OF AVAILABLE GUIDES, PROCEDURES, AND PROTOCOLS

Method validation is the process of evaluating whether an analytical method is acceptable for its intended purpose. For pharmaceutical methods, guidelines from the United States Pharmacopeia (USP), International Conference on Harmonisation (ICH), and the United States Food and Drug Administration (USFDA) provide a framework for performing such valications. In general, methods for regulatory compliance must include studies on specificity, linearity, accuracy, precision, range, detection limit, quantitation limit, and robustness. Elements of these guidelines are readily adapted to the issue of validation for beryllium sampling and analysis. This document provides a listing of available sources which can be used to validate analytical methods and/or instrumentation for beryllium determination. A literature review was conducted of available standard methods and publications used for method validation and/or quality control. A comprehensive listing of the articles, papers and books reviewed is given in the Appendix. Available validation documents and guides are listed therein; each has a brief description of application and use. In the referenced sources, there are varying approches to validation and varying descriptions of the valication process at different stages in method development. This discussion focuses on valication and verification of fully developed methods and instrumentation that have been offered up for use or approval by other laboratories or official consensus bodies such as ASTM International, the International Standards Organization (ISO) and the Association of Official Analytical Chemists (AOAC). This review was conducted as part of a collaborative effort to investigate and improve the state of validation for measuring beryllium in the workplace and the environment. Documents and publications from the United States and Europe are included. Unless otherwise specified, all referenced documents were published in English.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

OBSERVATIONS OF BINARY STARS WITH THE DIFFERENTIAL SPECKLE SURVEY INSTRUMENT. II. HIPPARCOS STARS OBSERVED IN 2010 JANUARY AND JUNE

The results of 497 speckle observations of Hipparcos stars and selected other targets are presented. Of these, 367 were resolved into components and 130 were unresolved. The data were obtained using the Differential Speckle Survey Instrument at the WIYN 3.5 m Telescope. (The WIYN Observatory is a joint facility of the University of Wisconsin-Madison, Indiana University, Yale University, and the National Optical Astronomy Observatories.) Since the first paper in this series, the instrument has been upgraded so that it now uses two electron-multiplying CCD cameras. The measurement precision obtained when comparing to ephemeris positions of binaries with very well known orbits is approximately 1-2 mas in separation and better than 0.{sup 0}6 in position angle. Differential photometry is found to be in very good agreement with Hipparcos measures in cases where the comparison is most relevant. We derive preliminary orbits for two systems.

79 ASTRONOMY AND ASTROPHYSICS↗

GNOSIS: THE FIRST INSTRUMENT TO USE FIBER BRAGG GRATINGS FOR OH SUPPRESSION

The near-infrared is an important part of the spectrum in astronomy, especially in cosmology because the light from objects in the early universe is redshifted to these wavelengths. However, deep near-infrared observations are extremely difficult to make from ground-based telescopes due to the bright background from the atmosphere. Nearly all of this background comes from the bright and narrow emission lines of atmospheric hydroxyl (OH) molecules. The atmospheric background cannot be easily removed from data because the brightness fluctuates unpredictably on short timescales. The sensitivity of ground-based optical astronomy far exceeds that of near-infrared astronomy because of this long-standing problem. GNOSIS is a prototype astrophotonic instrument that utilizes 'OH suppression fibers' consisting of fiber Bragg gratings and photonic lanterns to suppress the 103 brightest atmospheric emission doublets between 1.47 and 1.7 {mu}m. GNOSIS was commissioned at the 3.9 m Anglo-Australian Telescope with the IRIS2 spectrograph to demonstrate the potential of OH suppression fibers, but may be potentially used with any telescope and spectrograph combination. Unlike previous atmospheric suppression techniques GNOSIS suppresses the lines before dispersion and in a manner that depends purely on wavelength. We present the instrument design and report the results of laboratory and on-sky tests from commissioning. While these tests demonstrated high throughput ( Almost-Equal-To 60%) and excellent suppression of the skylines by the OH suppression fibers, surprisingly GNOSIS produced no significant reduction in the interline background and the sensitivity of GNOSIS+IRIS2 is about the same as IRIS2. It is unclear whether the lack of reduction in the interline background is due to physical sources or systematic errors as the observations are detector noise dominated. OH suppression fibers could potentially impact ground-based astronomy at the level of adaptive optics or greater. However, until a clear reduction in the interline background and the corresponding increasing in sensitivity is demonstrated optimized OH suppression fibers paired with a fiber-fed spectrograph will at least provide a real benefit at low resolving powers.

79 ASTRONOMY AND ASTROPHYSICS↗

KEPLER MISSION STELLAR AND INSTRUMENT NOISE PROPERTIES REVISITED

An earlier study of the Kepler Mission noise properties on timescales of primary relevance to detection of exoplanet transits found that higher than expected noise followed, to a large extent, from the stars rather than instrument or data analysis performance. The earlier study over the first six quarters of Kepler data is extended to the full four years ultimately comprising the mission. Efforts to improve the pipeline data analysis have been successful in reducing noise levels modestly as evidenced by smaller values derived from the current data products. The new analyses of noise properties on transit timescales show significant changes in the component attributed to instrument and data analysis, with essentially no change in the inferred stellar noise. We also extend the analyses to timescales of several days, instead of several hours to better sample stellar noise that follows from magnetic activity. On the longer timescale there is a shift in stellar noise for solar-type stars to smaller values in comparison to solar values.