Search NASA⌕ Search

SEARCH · Search NASA

Results for “LABORATORY EQUIPMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

EVSE Characterization: V2G EVSE Comparison

As part of the U.S. Department of Energy EVs@Scale consortium Next-Generation Profiles project, results and analysis from the characterization of high-power conductive and wireless charging infrastructure are presented. This characterization is conducted over a wide range of direct current (DC) current and DC voltage operation for nominal test conditions and off-nominal test conditions. Test plans and procedures were developed to define the test configurations and requirements, measurement parameters, and test procedures used throughout testing. Results from a 2024 study conducted on electric vehicle supply equipment (EVSE) characterization by the Idaho National Laboratory (INL) include two bi-directional vehicle-to-grid (V2G) capable EVSEs. These EVSE are referred to as V2G-EVSE9 and V2G-EVSE10. Laboratory testing is conducted at nominal test conditions to characterize the power transfer capabilities, efficiency, power factor, and other power quality metrics of the two DC EVSEs capable of V2G bi-directional power transfer. Results from testing show the performance is consistent for V2G-EVSE9 and V2G-EVSE10 when comparing charging to discharging performance, except for V2G-EVSE10 for power transfer when operating above 70% of the rated DC current. V2G-EVSE10 efficiency is >98% while charging and <91% while discharging at the same operating conditions, near maximum-rated current, at 300VDC. In contrast, V2G-EVSE9 results are consistent for charging and discharging. This EVSE is nearly 96% efficient while charging or discharging when operating over 50% of rated AC power. V2G EVSE performance is also characterized during off-nominal AC grid conditions involving AC voltage deviation (426 VAC to 518 VAC), AC frequency deviation of +2% (58.8 Hz to 61.2 Hz), and AC voltage harmonics injection. Many test conditions have little-to-no impact on performance characteristics of the two EVSEs; however, there are a few notable findings with significant power transfer capability impacts. AC voltage harmonics injection resulted in negative impacts on power quality attributes for both EVSEs, but with no impact on power transfer capability. Off-nominal AC voltage and frequency conditions resulted in unstable or lack of power transfer capability for both EVSEs. V2G-EVSE9 is unable to transfer power when AC voltage is >300V L-N. V2G-EVSE10 is unable to transfer power when AC frequency deviation exceeds +0.8%. V2G energy management system transient response and latency are quantified during laboratory testing. V2G-EVSE9 and V2G-EVSE10 utilize cloud-based V2G energy management systems that command the power transfer level between the EVSE and EV. The latency and response characteristics of the entire systems (web-based user interface, V2G energy management system, cellular communications, and EVSE response) are quantified through laboratory testing for V2G-EVSE9 and V2G-EVSE10. V2G-EVSE9 latency ranges from 0.8 to 1.8 seconds, whereas V2G-EVSE10 latency ranges from 3.4 to 8.8 seconds. The ramp rate to a change in power transfer request also differs between the two EVSEs. V2G-EVSE10 ramp rate ranges from 50% to -250% of rated AC power per second, whereas V2G-EVSE9 rate ranges from 95% to -95% of rated AC power per second. At the highest rate of change in power transfer, V2G-EVSE10 can change from full charge power to full discharge power in less than one second. The V2G EVSE characterization presented in this report provides valuable insights and results for use by numerous entities. This includes modeling and simulation organizations, decision makers, fleet planning, industry stakeholders, and many others involved with the development and deployment of electrified transportation technologies. Additional high-power DC chargers, bidirectional chargers, and inductive power transfer EVSE characterization results are anticipated from additional EVSE brands and models, which will be detailed in future publications in support of the U.S. Department of Energy EVs@Scale consortium Next-Gen Profiles project.

25 ENERGY STORAGE↗

Star tracker for the Apollo telescope mount

The star tracker for the Apollo Telescope Mount (ATM) has been designed specifically to meet the requirements of the Skylab vehicle and mission. The functions of the star tracker are presented, as well as descriptions of the optical-mechanical assembly (OMA) and the star tracker electronics (STE). Also included are the electronic and mechanical specifications, interface and operational requirements, support equipment and test requirements, and occultation information. Laboratory functional tests, environmental qualification tests, and life tests have provided a high confidence factor in the performance of the star tracker in the laboratory and on the Skylab mission.

Lee, C. E.↗

Evaluation of the benefits and feasibility of on-orbit repair by comparison with operations in an analogous environment - How is the Freedom Space Station like an oceanographic expedition?

Equipment maintenance and logistics strategies followed on the R/S Thompson, an oceanographic research vessel, are described, and parallels are drawn between the problems and solutions of an oceanographic expedition and those of a space station mission. Presumably oceanic expeditions, which have been conducted for over 150 years, have developed effective methods of equipment maintenance. Similarities are found in relative budget and equipment maintenance problems, but few similarities are found in solutions to these problems. It is speculated that the high relative cost of on-orbit work is responsible, and that development of significantly more effective component level fault diagnosis equipment and repair equipment could enable application of oceanographic equipment maintenance strategies, enhancing safety and speeding laboratory work while giving significant cost reduction.

Lewis, William C.↗

Flexible Generation Of Array-Detector Timing Signals

Assembly of custom-made electronic equipment and multipurpose commercial electronic equipment commonly found in electronics-development laboratories facilitates generation and modification of timing pattern signals for control of array detectors. Designed to serve as flexible electronic array-detector-testing apparatus configured via software; timing patterns created, stored, and changed easily. Assembly prepared for experimental evaluation of new detector design in much less time and less expense than necessary to construct special circuits to generate all timing patterns to be tried on new design.

Travis, Jeffrey W.↗

The use of the AOA TTR-4P GPS receiver in operation at the BIPM for real-time restitution of GPS time

The Global Positioning System is an outstanding tool for the dissemination of time. Using mono-channel C/A-code GPS time receivers, the restitution of GPS time through the satellite constellation presents a peak-to-peak discrepancy of several tens of nanoseconds without SA but may be as high as several hundreds of nanoseconds with SA. As a consequence, civil users are more and more interested in implementing hardware and software methods for efficient restitution of GPS time, especially in the framework of the project of a real-time prediction of UTC (UTCp) which could be available in the form of time differences (UTCp - GPS time). Previous work, for improving the real-time restitution of GPS time with SA, to the level obtained without SA, focused on the implementation of a Kalman filter based on past data and updated at each new observation. An alternative solution relies upon the statistical features of the noise brought about by SA; it has already been shown that the SA noise is efficiently reduced by averaging data from numerous satellites observed simultaneously over a sufficiently long time. This method was successfully applied to data from a GPS time receiver, model AOA TTR-4P, connected to the cesium clock kept at the BIPM. This device, a multi-channel, dual frequency, P-code GPS time receiver, is one of the first TTR-4P units in operation in a civil laboratory. Preliminary comparative studies of this new equipment with conventional GPS time receivers are described in this paper. The results of an experimental restitution of GPS time, obtained in June 1993, are also detailed: 3 to 6 satellites were observed simultaneously with a sample interval of 15 s, an efficient smoothing of SA noise was realized by averaging data on all observed satellites over more than 1 hour. When the GPS system is complete in 1994, 8 satellites will be observable continuously from anywhere in the world and the same level of uncertainty will be obtained using a shorter averaging time.

Thomas, Claudine↗

STS-103 Crew Training

The Hubble Space Telescope (HST) team is preparing for NASA's third scheduled service call to Hubble. This mission, STS-103, will launch from Kennedy Space Center aboard the Space Shuttle Discovery. The seven flight crew members are Commander Curtis L. Brown, Pilot Scott J. Kelly, European Space Agency (ESA) astronaut Jean-Francois Clervoy who will join space walkers Steven L. Smith, C. Michael Foale, John M. Grunsfeld, and ESA astronaut Claude Nicollier. The objectives of the HST Third Servicing Mission (SM3A) are to replace the telescope's six gyroscopes, a Fine-Guidance Sensor, an S-Band Single Access Transmitter, a spare solid-state recorder and a high-voltage/temperature kit for protecting the batteries from overheating. In addition, the crew plans to install an advanced computer that is 20 times faster and has six times the memory of the current Hubble Space Telescope computer. To prepare for these extravehicular activities (EVAs), the SM3A astronauts participated in Crew Familiarization sessions with the actual SM3A flight hardware. During these sessions the crew spent long hours rehearsing their space walks in the Guidance Navigation Simulator and NBL (Neutral Buoyancy Laboratory). Using space gloves, flight Space Support Equipment (SSE), and Crew Aids and Tools (CATs), the astronauts trained with and verified flight orbital replacement unit (ORU) hardware. The crew worked with a number of trainers and simulators, such as the High Fidelity Mechanical Simulator, Guidance Navigation Simulator, System Engineering Simulator, the Aft Shroud Door Trainer, the Forward Shell/Light Shield Simulator, and the Support Systems Module Bay Doors Simulator. They also trained and verified the flight Orbital Replacement Unit Carrier (ORUC) and its ancillary hardware. Discovery's planned 10-day flight is scheduled to end with a night landing at Kennedy.

Source record↗

Facilities

An expansion of medical data collection facilities was necessary to implement the Extended Duration Orbiter Medical Project (EDOMP). The primary objective of the EDOMP was to ensure the capability of crew members to reenter the Earth's atmosphere, land, and egress safely following a 16-day flight. Therefore, access to crew members as soon as possible after landing was crucial for most data collection activities. Also, with the advent of EDOMP, the quantity of investigations increased such that the landing day maximum data collection time increased accordingly from two hours to four hours. The preflight and postflight testing facilities at the Johnson Space Center (JSC) required only some additional testing equipment and minor modifications to the existing laboratories in order to fulfill EDOMP requirements. Necessary modifications at the landing sites were much more extensive.

Source record↗

The Role of Materials Degradation and Analysis in the Space Shuttle Columbia Accident Investigation

The efforts following the loss of the Space Shuttle Columbia included debris recovery, reconstruction, and analysis. The debris was subjected to myriad quantitative and semiquantitative chemical analysis techniques, ranging from examination via the scanning electron microscope (SEM) with energy dispersive spectrometer (EDS) to X-Ray diffraction (XRD) and electron probe micro-analysis (EPMA). The results from the work with the debris helped the investigators determine the location where a breach likely occurred in the leading edge of the left wing during lift off of the Orbiter from the Kennedy Space Center. Likewise, the information evidenced by the debris was also crucial in ascertaining the path of impinging plasma flow once it had breached the wing. After the Columbia Accident Investigation Board (CAIB) issued its findings, the major portion of the investigation was concluded. However, additional work remained to be done on many pieces of debris from portions of the Orbiter which were not directly related to the initial impact during ascent. This subsequent work was not only performed in the laboratory, but was also performed with portable equipment, including examination via portable X-Ray fluorescence (XRF) and Fourier transform infrared spectroscopy (FTIR). Likewise, acetate and silicon-rubber replicas of various fracture surfaces were obtained for later macroscopic and fractographic examination. This paper will detail the efforts and findings from the initial investigation, as well as present results obtained by the later examination and analysis of debris from the Orbiter including its windows, bulkhead structures, and other components which had not been examined during the primary investigation.

McDanels, Steven J.↗

Cryogenic Insulation Standard Data and Methodologies Project

Extending some recent developments in the area of technical consensus standards for cryogenic thermal insulation systems, a preliminary Inter-Laboratory Study of foam insulation materials was performed by NASA Kennedy Space Center and LeTourneau University. The initial focus was ambient pressure cryogenic boil off testing using the Cryostat-400 flat-plate instrument. Completion of a test facility at LETU has enabled direct, comparative testing, using identical cryostat instruments and methods, and the production of standard thermal data sets for a number of materials under sub-ambient conditions. The two sets of measurements were analyzed and indicate there is reasonable agreement between the two laboratories. Based on cryogenic boiloff calorimetry, new equipment and methods for testing thermal insulation systems have been successfully developed. These boiloff instruments (or cryostats) include both flat plate and cylindrical models and are applicable to a wide range of different materials under a wide range of test conditions. Test measurements are generally made at large temperature difference (boundary temperatures of 293 K and 78 K are typical) and include the full vacuum pressure range. Results are generally reported in effective thermal conductivity (ke) and mean heat flux (q) through the insulation system. The new cryostat instruments provide an effective and reliable way to characterize the thermal performance of materials under subambient conditions. Proven in through thousands of tests of hundreds of material systems, they have supported a wide range of aerospace, industry, and research projects. Boiloff testing technology is not just for cryogenic testing but is a cost effective, field-representative methodology to test any material or system for applications at sub-ambient temperatures. This technology, when adequately coupled with a technical standards basis, can provide a cost-effective, field-representative methodology to test any material or system for applications at sub-ambient to cryogenic temperatures. A growing need for energy efficiency and cryogenic applications is creating a worldwide demand for improved thermal insulation systems for low temperatures. The need for thermal characterization of these systems and materials raises a corresponding need for insulation test standards and thermal data targeted for cryogenic-vacuum applications. Such standards have a strong correlation to energy, transportation, and environment and the advancement of new materials technologies in these areas. In conjunction with this project, two new standards on cryogenic insulation were recently published by ASTM International: C1774 and C740. Following the requirements of NPR 7120.10, Technical Standards for NASA Programs and Projects, the appropriate information in this report can be provided to the NASA Chief Engineer as input for NASA's annual report to NIST, as required by OMB Circular No. A-119, describing NASA's use of voluntary consensus standards and participation in the development of voluntary consensus standards and bodies.

Technology Portfolio System↗

A Transmission Electron Microscopy Study of a Refractory Metal Grain from a Calcium-Aluminum-Rich Inclusion in the Leoville CV3 Chondrite

Introduction: Calcium-aluminum-rich inclusions (CAIs) are an important component of chondritic meteorites. They can contain materials that are thermodynamically predicted and isotopically age dated to be among the first-formed solids in our solar system [1-5]. Observed in some CAIs are micron to sub-micron sized inclusions rich in Fe, Ni, and high-Z elements such as Pt, Os, Ir and W, in the form of refractory metal nuggets (RMNs), fremdlinges, and ‘nugget like objects’ (NLOs) [1,6]. Refractory siderophile elements such as Os, Ir and Ru are thermodynamically predicted to condense at temperatures well in excess of the major CAI phases such as melilite, perovskite, spinel and hibonite [2,7-9]. These refractory metal inclusions in CAIs can therefore serve as probes into the thermodynamic landscape of the early solar protoplanetary disk. Here we report on a refractory grain identified in a CAI of the Leoville CV3 chondrite. This work is part of an ongoing effort to gain insight into the thermochemistry of the early solar system through systematic analyses of the structure and chemistry of various components in CAIs [10-13]. Sample and Analytical Techniques: A fluffy type A CAI (Fig. 1A) was identified in a section of the Leoville, CV3 chondrite (Center for Meteorite Studies, Arizona State University collection, #821_C_3) using a JOEL-JXA 8530F electron microprobe at Arizona State University. Backscattered electron (BSE) imaging and energy-dispersive X-ray spectroscopy (EDS) were used to identify refractory metal grains in the CAI using a Thermo Fisher (formerly FEI) Helios NanoLab 660 G3 focused-ion-beam scanning-electron microscope (FIBSEM) located at the Kuiper Materials Imaging and Characterization Facility (KMICF) at the Lunar and Planetary Laboratory, University of Arizona. The FIB is equipped with an EDAX EDS system. We selected one of the larger (micron-sized) refractory metal grains, designated as ‘Spud’ (Fig. 1B) for further analysis. ‘Spud’ was extracted and thinned to electron transparency (<100 nm) using the FIB-SEM located in KMICF, following methods described by [14- 15]. The FIB section was analyzed using a 200 keV Hitachi HF5000 scanning transmission electron microscope (S/TEM) located at KMICF. The HF5000 is equipped with cold-field emission gun, 3rd-order spherical aberration corrector for STEM imaging, and an Oxford Instruments X-Max N 100 TLE energydispersive spectroscopy (EDS) system with dual 100 mm2 windowless silicon-drift detectors (Ω = 2.0 sr). Selected-area electron-diffraction (SAED) patterns were acquired to aid in determination of crystallinity and phase. Results: The mineralogy, texture, and morphology of the CAI are consistent with that of a fluffy type A (FTA) CAI [16]. BSE imaging at high magnifications revealed grains with high contrast, indicative of compositions rich in elements of higher atomic number relative to surrounding material. These high-Z grains have sizes that range from ∼250 nm to 4 µm. EDS analyses confirm that the bright grains are metal-rich inclusions. A minor fraction of the grains are composed of only Fe and Ni, but the majority (∼60%) of the identified inclusions also contained various refractory siderophiles including Os, Ru, Zr, Ir and Mo. EDS analysis on the FIB-SEM of Spud shows that it contains Fe, Ni, Mo and Ru. High-angle annular dark-field (HAAFD) imaging and EDS mapping in the TEM (Fig. 2) show that Spud occurs in melilite (Ca1.9Al1.99Si1.06O7). Spud contains a subhedral to anhedral morphology and is compositionally heterogenous (polyphasic, Fig. 2). Local spatial correlation occurs among Fe, Ni, and Pt, and also among Os, Ru, and Mo. SAED patterns show that the Fe-Ni-Pt, Fe-Os-Mo-Ru and Fe-Pt regions are crystalline. Discussion: CAIs can contain various types of inclusions rich in Fe, Ni and refractory siderophiles such as Os, Ru, W and Pt [1]. RMNs are micron-sized, single phase alloy grains and can contain Os, Ir, Ru and Rh [1,7,17]. NLOs are also micron-sized inclusions, but contain two phases, a refractory metal, and an oxide [6]. Fremdlinge are the largest of such inclusions (tens of microns in size) and are complex aggregates of Fe-Ni alloy, silicates, oxides, and sulfides [1,17]. While the size of Spud matches previous descriptions of RMNs and NLOs, Spud is neither a single-phase alloy like RMNs, nor does it contain one metal phase and one oxide like NLOs. Spud does not match the above described categories of refractory metal inclusions. The presence of refractory siderophiles such as Mo, Os, Ru, and Pt suggests a high-temperature origin. Thermodynamic modelling by [7] indicates condensation temperatures of 1917 K, 1693 K, 1613 K and 1415 K for Os, Mo, Ru and Pt respectively. These models also show that following the initial condensation of a refractory metal, alloying of solutes such as Fe, Ni and W, occurs in levels proportional to their partial pressures in the surrounding gas. Such alloying occurs at temperatures above the condensation temperatures of common CAI phases such as melilite (1529 K), perovskite (1441 K), spinel (197 K) and forsterite (1354 K) [2]. The polyphasic nature of Spud could be the result of such high-temperature alloying, possibly shortly after the condensation of Mo and Ru at 1693 K and 1613 K respectively. That Spud occurs as an inclusion is consistent with it having formed prior to and at temperature above that of its host melilite in this FTA CAI, which is qualitatively consistent with such prior thermodynamic modeling. Further, the polyphasic nature of Spud is similar to refractory grains from a FTA CAI in the Northwest Africa (NWA) 8323, CV3 chondrite [11-13]. These data suggest that such refractory metal grains could have been widespread in the inner and early solar protoplanetary disk and represent some of the earliest formed solids to have condensed. Acknowledgments: Research and instrumentation supported by NASA grants #NNX12AL47G, #NNX15AJ22G and #80NSSC19K0509, and NSF grants #1531243 and #0619599. Fig 2. STEM data on ‘Spud’. HAADF Image (Top) False-color EDS Maps (Bottom) References: [1] MacPherson G. J. (2014) T. of Geochem. Vol I: Met. And Cosmochem. Processes, 139-179. [2] Lodders K. (2003) ApJ, 591, 1220-1247. [3] Ebel D. S. (2006) Met. & the Early S. Sys. II., 253- 277. [4] Amelin Y. (2002) Science, 297, 1678-1683. [5] Connelly J.N. et.al. (2012) Science, 338, 651-655. [6] Schwander D. et al. (2015) GCA, 18, 70-87. [7] Palme H. and Wlotzka F. (1976) EPSL, 33, 45-60. [8] Berg T. et al. (2009) ApJ, 702, 172-176. [9] Liffman K. et al. (2021) Icarus, 221, 89-105. [10] Zega T.J. et al. (2021) PSJ, 2, 115. [11] Ramprasad T. et al. (2020) LPSC LI, Abstract #2472. [12] Ramprasad T. et al. (2021) Microscopy & Microanalysis, S1, 2792-2794. [13] Ramprasad T. et al. (2021) 84th MetSoc, Abstract #6123. [14] Zega T.J. et al. (2007) MAPS, 42, 1373-1386. [15] Ramprasad T. et al. (2022) MAPS, in revision. [16] Grossman L. (1975), GCA, 39, 433-454. [17] El Goresy A. et al. (1978) LPSC IX, Abstract#1100

T. Ramprasad↗

Pulsed Electroacoustic Analysis Capabilities at NASA Glenn Research Center

The High Voltage Testing Laboratory at NASA Glenn Research Center is equipped with a pulsed electroacoustic (PEA) analyzer to study space charge phenomena in dielectric materials. Dielectric materials such as those used in high voltage insulation systems are of great interest due to their crucial role in withstanding high voltages and avoiding electrical breakdown in electrified aircraft power systems. Current research is underway for the development of novel lightweight electrical insulation and the thorough evaluation of these materials is required. The PEA instrumentation at NASA GRC is a nondestructive method to evaluate the space charge phenomena which can give a unique insight on the feasibility and lifetime of material systems. The instrumentation capability and initial results are reported here.

pulsed electroacoustic↗

Savannah River Site Eastern Transportation Hub: A Concept For a DOE Eastern Packaging, Staging and Maintenance Center - 13143

The Department of Energy (DOE) is working to de-inventory sites and consolidate hazardous materials for processing and disposal. The DOE administers a wide range of certified shipping packages for the transport of hazardous materials to include Special Nuclear Material (SNM), radioactive materials, sealed sources and radioactive wastes. A critical element to successful and safe transportation of these materials is the availability of certified shipping packages. There are over seven thousand certified packagings (i.e., Type B/Type AF) utilized within the DOE for current missions. The synergistic effects of consolidated maintenance, refurbishment, testing, certification, and costing of these services would allow for efficient management of the packagings inventory and to support anticipated future in-commerce shipping needs. The Savannah River Site (SRS) receives and ships radioactive materials (including SNM) and waste on a regular basis for critical missions such as consolidated storage, stabilization, purification, or disposition using H-Canyon and HB-Line. The Savannah River National Laboratory (SRNL) has the technical capability and equipment for all aspects of packaging management. SRS has the only active material processing facility in the DOE complex and is one of the sites of choice for nuclear material consolidation. SRS is a logical location to perform maintenance and periodic testing of the DOE fleet of certified packagings. This initiative envisions a DOE Eastern Packaging Staging and Maintenance Center (PSMC) at the SRS and a western hub at the Nevada National Security Site (NNSS), an active DOE Regional Disposal Site. The PSMC's would be the first place DOE would go to meet their radioactive packaging needs and the primary locations projects would go to disposition excess packaging for beneficial reuse. These two hubs would provide the centralized management of a packaging fleet rather than the current approach to design, procure, maintain and dispose of packagings on a project-by-project basis. This initiative provides significant savings in packaging costs and acceleration of project schedules. In addition to certified packaging, the PSMC would be well suited for select designs of 7A Type A packaging and Industrial Packaging. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Advanced Rooftop Control (ARC) Retrofit: Field-Test Results

The multi-year research study was initiated to find solutions to improve packaged equipment operating efficiency in the field. Pacific Northwest National Laboratory (PNNL), with funding from the U.S. Department of Energy’s (DOE’s) Building Technologies Office (BTO) and Bonneville Power Administration (BPA) conducted this research, development and demonstration (RD&D) study. Packaged equipment with constant speed supply fans is designed to provide ventilation at the design rate at all times when the fan is operating as required by building code. Although there are a number of hours during the day when a building may not be fully occupied or the need for ventilation is lower than designed, the ventilation rate cannot be adjusted easily with a constant speed fan. Therefore, modulating the supply fan in conjunction with demand controlled ventilation (DCV) will not only reduce the coil energy but also reduce the fan energy. The objective of this multi-year research, development and demonstration project was to determine the magnitude of energy savings achievable by retrofitting existing packaged rooftop air conditioners with advanced control strategies not ordinarily used for packaged units. First, through detailed simulation analysis, it was shown that significant energy (between 24% and 35%) and cost savings (38%) from fan, cooling and heating energy consumption could be realized when packaged air conditioning units with gas furnaces are retrofitted with advanced control packages (combining multi-speed fan control, integrated economizer controls and DCV). The simulation analysis also showed significant savings for heat pumps (between 20% and 60%). The simulation analysis was followed by an extensive field test of a retrofittable advanced rooftop unit (RTU) controller.

Katipamula, Srinivas↗

Long path monitoring of tropospheric O3, NO2, H2CO and SO2

Concentrations of tropospheric O3, NO2, H2CO, and SO2 have been measured on the Campus of the 'Universite Libre de Bruxelles' on a routine basis since October 1990. The long path system consists of a source lamp, a first 30 cm f/8 Cassegrain type telescope which collimates the light onto a slightly parabolic mirror placed on the roof of a building situated 394 m away from the laboratory. The light is sent back into a second 30 cm Cassegrain telescope. This telescope has been modified so that the output beam is a 5 cm diameter parallel beam. This beam is then focused onto the entrance aperture of the BRUKER IFS120HR fourier transform spectrometer. The two telescopes are mounted on alignment devices and the external mirror is equipped with a driving system operated from the laboratory. The choice of the light source (either a 1000 W high pressure 'ozone free' xenon lamp or a 250 W tungsten filament) and of the detector (either a solar blind UV-diode or a silicon diode) depended on the spectral region studied. These regions lie respectively from 26,000 cm(exp -1) to 30,000 cm(exp -1) (260-380 nm) and from 14,000 cm(exp -1) to 30,000 cm(exp -1) (330-700 nm). The spectra have been recorded at the resolution of 16 cm(exp -1) and with a dispersion of 7.7 cm(exp -1). They have been measured during the forward and the backward movements of the mobile mirror, in double sided mode; each spectrum is an average of 2000 scans. The time required to record a spectrum is about 45 minutes. The shape of the raw spectra in the two investigated regions are represented.

Vandaele, A. C.↗

Challenges to Collection of High Quality Samples of Saltstone - 17468

The Savannah River Site (SRS) Saltstone Disposal Facility (SDF) is used to dispose of low-level radioactive liquid waste in the form of grout. The SDF is comprised of a series of concrete saltstone disposal units (SDUs) that receive the grout. The grout solidifies into a cementitious waste form known as saltstone. Properties of saltstone that influence contaminant release have been measured on simulant material but not on samples of emplaced saltstone because samples of emplaced radioactive saltstone are difficult to obtain, transport, and store in a manner that protects the properties of interest. Savannah River Remediation (SRR) initiated a project to obtain samples of emplaced saltstone such that the two critical properties, hydraulic conductivity and reduction capacity, are negligibly impacted by the sample collection effort. The sample collection project was established to manage sample collection efforts beginning with sample collection mock-up activities through field execution. The project focused on three phases: mock-up in a clean environment, development of equipment needed to maintain an inert environment during sample transport and laboratory storage, and coordination of Facility operations and support resources and schedules to support sample collection. A mock-up facility was constructed at SRS to mimic the SDU. Core drill equipment was tested, procedures developed, and operator training conducted using the mockup facility. Concurrent with mock-up activities, inert transportation and storage equipment was designed, manufactured, tested, and specific operating instruction included in the sample collection procedure. Inerting equipment minimized oxidation from the atmosphere as the samples were removed from the disposal unit, transported, and stored in the laboratory awaiting analysis. Coordination with the Saltstone Facility began during construction of the mock-up platform to collect current as-built information for platform construction. Baseline data was collected from the disposal unit vapor space to assess the potential for personnel exposure from chemical hazards associated with trapped vapors. Based on this data, mitigating actions were incorporated into the project scope. Finally, project and facility schedules were integrated to assure that facility non-processing windows, support personnel, equipment fabrication, and field preparation activities were in alignment and supportive of the overall sample collection objectives. During May 2014, 485 linear cm of approximately 5 cm diameter radioactive core material was successfully collected from three access ports in SDU Cell 2A, inerted, transported to the laboratory, and stored in an inert environment for analysis. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗