Search NASA⌕ Search

SEARCH · Search NASA

Results for “LINEAR PROGRAMMING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Status of Research Activities on LVDTs: Modeling and Simulation Development and Performance Characterization of Commercial LVDTs

FY-22 research focused on two major areas. The first area was modeling and simulation with linked testing that will advance the Linear Variable Differential Transformers (LVDT) technology for use by stakeholders requiring LVDTs in upcoming irradiation tests. The second area focused on testing LVDTs purchased from U.S. suppliers that were investigated in FY-21. These cross-cutting development activities will ensure stakeholders have the current state-of-the-art LVDT-based technologies for deployment in future irradiation tests. Two stand-alone reports are included in the appendixes. The purpose of this report is to provide a convenient body of work to access the reports and to evaluate the data and conclusions provided. Appendix A, “Testing of the RDP Translation Transducer,” contains a complete evaluation of an RDP Electrosense linear transducer that has the capability of replicating the form, fit, and function of LVDTs currently being used at Idaho National Laboratory (INL). Appendix B is an extract from the report, “Advanced Sensors and Instrumentation Program at Boise State University (BSU), August 2022, Linear Variable Differential Transformers.” This report contains modeling and testing results conducted at BSU and INL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Simulation and test of a strip source electron gun

We present simulation and test of an indirectly heated strip source electron beam gun assembly using Stanford Linear Accelerator Center (SLAC) electron beam trajectory program. The beam is now sharply focused with 3.04 mm diameter in the post anode region at 15.9 mm. The measured emission current and emission density were 1.12 A and 1.15 A/cm{sup 2}, respectively, that corresponds to power density of 11.5 kW/cm{sup 2}, at 10 kV acceleration potential. The simulated results were compared with then and now experiments and found in agreement. The gun is without any biasing, electrostatic and magnetic fields; hence simple and inexpensive. Moreover, it is now more powerful and is useful for accelerators technology due to high emission and low emittance parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A centralized-based method to determine the local voltage control strategies of distributed generator operation in active distribution networks

The increasing penetration of distributed generators (DGs) exacerbates the risk of voltage violations in active distribution networks (ADNs). The var capacity provided by DG inverters is a potential solution for voltage regulation. The conventional centralized control strategies limited by computation and communication burdens are difficult to meet the requirement of rapid voltage control. However, the local control strategies based on real-time measurements have a fast response to the frequent fluctuations of DG outputs. The performance of these local controllers depends on the tuning of the control parameters. This paper proposes a centralized-based method to determine the local voltage control strategies for DGs. A centralized parameter tuning model of control curves is built, in which and curves of DG inverters are mathematically formulated based on piecewise linearization. The original mixed-integer nonlinear programming (MINLP) model is converted into an effectively solved mixed-integer second-order cone programming (MISOCP) model using convex relaxation. The potential benefits of DG inverters are explored to regulate both reactive and curtailed active power, based on local voltage measurements. Case studies on a modified PG&E 69-node distribution system are carried out to verify the effectiveness of the proposed method. Results show that power losses of ADNs are significantly reduced and voltage profiles are also improved.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SU-E-T-570: New Quality Assurance Method Using Motion Tracking for 6D Robotic Couches

Purpose: To accommodate geometrically accurate patient positioning, a robotic couch that is capable of 6-degrees of freedom has been introduced. However, conventional couch QA methods are not sufficient to enable the necessary accuracy of tests. Therefore, we have developed a camera based motion detection and geometry calibration system for couch QA. Methods: Employing a Visual-Tracking System (VTS, BonitaB10, Vicon, UK) which tracks infrared reflective(IR) markers, camera calibration was conducted using a 5.7 × 5.7 × 5.7 cm{sup 3} cube attached with IR markers at each corner. After positioning a robotic-couch at the origin with the cube on the table top, 3D coordinates of the cube’s eight corners were acquired by VTS in the VTS coordinate system. Next, positions in reference coordinates (roomcoordinates) were assigned using the known relation between each point. Finally, camera calibration was completed by finding a transformation matrix between VTS and reference coordinate systems and by applying a pseudo inverse matrix method. After the calibration, the accuracy of linear and rotational motions as well as couch sagging could be measured by analyzing the continuously acquired data of the cube while the couch moves to a designated position. Accuracy of the developed software was verified through comparison with measurement data when using a Laser tracker (FARO, Lake Mary, USA) for a robotic-couch installed for proton therapy. Results: VTS system could track couch motion accurately and measured position in room-coordinates. The VTS measurements and Laser tracker data agreed within 1% of difference for linear and rotational motions. Also because the program analyzes motion in 3-Dimension, it can compute couch sagging. Conclusion: Developed QA system provides submillimeter/ degree accuracy which fulfills the high-end couch QA. This work was supported by the National Research Foundation of Korea funded by Ministry of Science, ICT & Future Planning. (2013M2A2A7043507 and 2012M3A9B6055201)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-138: Commissioning and Evaluating Dose Computation Models for a Dedicated Proton Line Scanning Beam Nozzle in Eclipse Treatment Planning System

Purpose: In this study, we present an effective method to derive low dose envelope of the proton in-air spot fluence at beam positions other than the isocenter to reduce amount of measurements required for planning commission. Also, we demonstrate commissioning and validation results of this method to the Eclipse treatment planning system (version 13.0.29) for a Sumitomo dedicated proton line scanning beam nozzle. Methods: The in-air spot profiles at five beam-axis positions (±200, ±100 and 0 mm) were obtained in trigger mode using a MP3 Water tank (PTW-Freiburg) and a pinpoint ionization chamber (model 31014, PTW-Freiburg). Low dose envelope (below 1% of the center dose) of the spot profile at isocenter was obtained by repeated point measurements to minimize dosimetry uncertainty. The double Gaussian (DG) model was used to fit and obtain optimal σ1, σ2 and their corresponding weightings through our in-house MATLAB (Mathworks) program. σ1, σ2 were assumed to expand linearly along the beam axis from a virtual source position calculated by back projecting fitted sigmas from the single Gaussian (SG) model. Absolute doses in water were validated using an Advanced Markus chamber at the depth of 2cm with Pristine Peak (BP) R90d ranging from 5–32 cm for 10×10 cm2 scanned fields. The field size factors were verified with square fields from 2 to 20 cm at 2cm and before BP depth. Results: The absolute dose outputs were found to be within ±3%. For field size factor, the agreement between calculated and measurement were within ±2% at 2cm and ±3% before BP, except for the field size below 2×2 cm2. Conclusion: The double Gaussian model was found to be sufficient for characterizing the Sumitomo dedicated proton line scanning nozzle. With our effective double Gaussian fitting method, we are able to save significant proton beam time with acceptable output accuracy.

60 APPLIED LIFE SCIENCES↗

Development of Interconnect Technologies for Particle Detectors

This final report covers the three years of this grant, for the funding period 9/1/2010 - 8/31/2013. The project consisted of generic detector R&D work at UC Davis, with an emphasis on developing interconnect technologies for applications in HEP. Much of the work is done at our Facility for Interconnect Technologies (FIT) at UC Davis. FIT was established using ARRA funds, with further studies supported by this grant. Besides generic R&D work at UC Davis, FIT is engaged in providing bump bonding help to several DOE supported detector R&D efforts. Some of the developmental work was also supported by funding from other sources: continuing CMS project funds and the Linear Collider R&D funds. The latter program is now terminated. The three year program saw a good deal of progress on several fronts, which are reported here.

43 PARTICLE ACCELERATORS↗

A Massively Parallel Implementation of the CCSD(T) Method Using the Resolution-of-the-Identity Approximation and a Hybrid Distributed/Shared Memory Parallelization Model

In this work, a parallel algorithm is described for the coupled-cluster singles and doubles method augmented with a perturbative correction for triple excitations [CCSD(T)] using the resolution-of-the-identity (RI) approximation for two-electron repulsion integrals (ERIs). The algorithm bypasses the storage of four-center ERIs by adopting an integral-direct strategy. The CCSD amplitude equations are given in a compact quasi-linear form by factorizing them in terms of amplitude-dressed three-center intermediates. A hybrid MPI/OpenMP parallelization scheme is employed, which uses the OpenMP-based shared memory model for intranode parallelization and the MPI-based distributed memory model for internode parallelization. Parallel efficiency has been optimized for all terms in the CCSD amplitude equations. Two different algorithms have been implemented for the rate-limiting terms in the CCSD amplitude equations that entail and -scaling computational costs, where N O and N V denote the number of correlated occupied and virtual orbitals, respectively. One of the algorithms assembles the four-center ERIs requiring N V 4 and N O 2 N V 2 -scaling memory costs in a distributed manner on a number of MPI ranks, while the other algorithm completely bypasses the assembling of quartic memory-scaling ERIs and thus largely reduces the memory demand. It is demonstrated that the former memory-expensive algorithm is faster on a few hundred cores, while the latter memory-economic algorithm shows a better strong scaling in the limit of a few thousand cores. The program is shown to exhibit a near-linear scaling, in particular for the compute-intensive triples correction step, on up to 8000 cores. The performance of the program is demonstrated via calculations involving molecules with 24–51 atoms and up to 1624 atomic basis functions. As the first application, the complete basis set (CBS) limit for the interaction energy of the π-stacked uracil dimer from the S66 data set has been investigated. This work reports the first calculation of the interaction energy at the CCSD(T)/aug-cc-pVQZ level without local orbital approximation. The CBS limit for the CCSD correlation contribution to the interaction energy was found to be -8.01 kcal/mol, which agrees very well with the value -7.99 kcal/mol reported by Schmitz, Hättig, and Tew [ Phys. Chem. Chem. Phys. 2014 , 16 , 22167-22178]. The CBS limit for the total interaction energy was estimated to be -9.64 kcal/mol.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

iSPECTRON: a simulation interface for linear and nonlinear spectra with ab-initio quantum chemistry software

We introduce iSPECTRON, an open source (under the Educational Community License version 2.0) program that parses data from common quantum chemistry software (NWChem, OpenMolcas, Gaussian, Cobramm, etc.), produces the input files for the simulation of linear and nonlinear spectroscopy of molecules with the Spectron code, and analyzes the spectra with a broad range of tools. Vibronic spectra are expressed in term of the electronic eigenstates, obtained through quantum chemistry computations, and vibrational/bath effects are incorporated in the framework of the displaced harmonic oscillator model, where all required quantities are computed at the Franck-Condon point. The code capabilities are illustrated by simulating linear absorption, transient absorption and two dimensional electronic spectra of the pyrene molecule. Two levels of electronic structure theory, TDDFT (with NWChem) and RASSCF/RASPT2 (with OpenMolcas), are compared where possible. Acknowledgements: F.S., A.N., D.R.N., N.G., S.M, M.G. acknowledge support from the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences, Chemical Sciences, Geosciences, and Biosciences Division under Award Nos. DE-SC0019484, KC-030103172684. The Spectron code was developed with support from the National Science Foundation (Grant CHE- 1953045). This research benefited from computational resources provided by EMSL, a DOE Office of Science User Facility sponsored by the Office of Biological and Environmental Research and located at PNNL. PNNL is operated by Battelle Memorial Institute for the United States Department of Energy under DOE Contract No. DE-AC05-76RL1830.

Segatta, Francesco↗

TH-EF-BRB-04: 4π Dynamic Conformal Arc Therapy Dynamic Conformal Arc Therapy (DCAT) for SBRT

Purpose: To develop an efficient and effective trajectory optimization methodology for 4π dynamic conformal arc treatment (4π DCAT) with synchronized gantry and couch motion; and to investigate potential clinical benefits for stereotactic body radiation therapy (SBRT) to breast, lung, liver and spine tumors. Methods: The entire optimization framework for 4π DCAT inverse planning consists of two parts: 1) integer programming algorithm and 2) particle swarm optimization (PSO) algorithm. The integer programming is designed to find an optimal solution for arc delivery trajectory with both couch and gantry rotation, while PSO minimize a non-convex objective function based on the selected trajectory and dose-volume constraints. In this study, control point interaction is explicitly taken into account. Beam trajectory was modeled as a series of control points connected together to form a deliverable path. With linear treatment planning objectives, a mixed-integer program (MIP) was formulated. Under mild assumptions, the MIP is tractable. Assigning monitor units to control points along the path can be integrated into the model and done by PSO. The developed 4π DCAT inverse planning strategy is evaluated on SBRT cases and compared to clinically treated plans. Results: The resultant dose distribution of this technique was evaluated between 3D conformal treatment plan generated by Pinnacle treatment planning system and 4π DCAT on a lung SBRT patient case. Both plans share the same scale of MU, 3038 and 2822 correspondingly to 3D conformal plan and 4π DCAT. The mean doses for most of OARs were greatly reduced at 32% (cord), 70% (esophagus), 2.8% (lung) and 42.4% (stomach). Conclusion: Initial results in this study show the proposed 4π DCAT treatment technique can achieve better OAR sparing and lower MUs, which indicates that the developed technique is promising for high dose SBRT to reduce the risk of secondary cancer.

60 APPLIED LIFE SCIENCES↗

Factors Affecting Override Behavior during Demand Flexibility from High-Resolution Smart Thermostat Data

In this study, we delineate key weather and demographic predictors of override behavior in residential buildings during connected thermostats demand response events. Anticipating and reducing overrides is critical to demand flexibility (DF) program success. We use high- dimensional fixed effects linear regression techniques on a large ecobee dataset for about 5,000 enrolled households in the United States. We identify critical weather (indoor and outdoor temperature), building (housing type), and occupant (previous DF overrides and previous DF event exposure) factors influencing the override patterns of customers during thermostat demand response. We also differentiate DF events by season to understand the different indoor and outdoor conditions that might influence seasonal override rates. We found significant differences in override rates between building types, with single-family semi-detached homes generally having the highest overrides. Having a history of overrides was additionally a critical factor in predicting occupant response to future DF events. Understanding these override differences is necessary for rural electric cooperatives and emerging DF programs without access to large DR historical data. Overall, we provide critical information on technical and local demographic characteristics that may be correlated to building type to influence strategies to reduce overrides and improve the adoption of DF technologies.

connected thermostats (CTs)↗

Iterative Linearization for Phasor-Defined Optimal Power Dispatch

Optimal power flow (OPF) problems, which dispatch power targets to controllable generating units across a network, must generally account for non-convex constraints on power flow. Furthermore, adapting those problems so as to make them solvable with convex optimization techniques is an area of much academic and operational interest. In this paper, we present a method for solving OPF as a quadratic program by iteratively refining and re-initializing a linearized model of power flow based on the outputs of an associated nonlinear solver. The linear model on which we demonstrate this method is an adapted version of an approximation designed for use with unbalanced distribution networks. As an important benefit, the model allows for the explicit inclusion of nodal voltage phasor values in both the OPF problem's objective and its constraints, which opens the door to the idea of phasor-based control (PBC) design. We show in simulations on the IEEE 13-node test feeder that our method quickly converges to a set of phasor targets that are sufficiently precise for use in operations at the distribution level.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High Power Superconducting Electron Linear Accelerators For Industrial Application

Fermilab is executing a technology development program to develop a compact yet powerful electron accelerator. We are leveraging R&D breakthroughs in SRF cavities, cost-effective radio-frequency sources, modern cryo-coolers, and high average current electron guns. We show that a single accelerator module can deliver average beam power as high as 1 MW through detailed thermal, RF, and particle simulations.

Thangaraj, Jayakar Tobin↗

Infrared Metamaterials

This document serves as the final report for the AFRL SBIR Program "Directionally-Tailored Infrared Emission and/or Transmission" AF 1 O-BT30 The focus of this program was in the development and design of a thermal emission surface with thermal emission directed away from broadside in the L WIR band. In the report, a basic overview is provided covering past research efforts in thermal emission surfaces and the fundamental science of directional emitters. Multiple sets of designs are investigated as candidate directional emission surfaces: dark element, image, and end-fire linear array, broadside emitter, and waveguide emitter. Based on program results, both the broadside emitter and waveguide emitter designs appear to meet the needs of the AF directional emission requirements. These designs offer a range of directional emission behavior (controllable emission beamwidth and bandwidth) and scale well to mass production. The designs require additional environmental testing, but appear to be suitable for space application as well. All goals of the program appear to have been met and the team is looking forward to future development.

36 MATERIALS SCIENCE↗

Neutron Cross Section Measurements at ORELA for Improved Nuclear Data and Their Application

Many older neutron cross-section evaluations from libraries such as ENDF/B-VI or JENDL-3.2 exhibit deficiencies or do not cover energy ranges that are important for criticality safety applications. These deficiencies may occur in the resolved and unresolved-resonance regions. Consequently, these evaluated data may not be adequate for nuclear criticality calculations where effects such as self-shielding, multiple scattering, or Doppler broadening are important. To support the Nuclear Criticality Predictability Program, neutron cross-section measurements have been initiated at the Oak Ridge Electron Linear Accelerator (ORELA). ORELA is the only high-power white neutron source with excellent time resolution still operating in the United States. It is ideally suited to measure fission, neutron total, and capture cross sections in the energy range from 1 eV to {approx}600 keV, which is important for many nuclear criticality safety applications.

43 PARTICLE ACCELERATORS↗

The Material Plasma Exposure eXperiment: Mission and conceptual design

Mastering Plasma Material Interactions (PMI) is key for obtaining a high performance, high duty-cycle and safe operating fusion reactor. Numerous gaps exist in PMI which have to be addressed before a reactor can be built. In particular the lack of data at high ion fluence, fusion reactor divertor relevant plasma conditions and neutron displacement damage requires new experimental devices to be able to develop plasma facing materials and components. This has been recognized in the community and the U.S. fusion program is addressing this need with a new linear plasma device—the Material Plasma Exposure eXperiment (MPEX). MPEX will be a superconducting linear plasma device with magnetic fields of up to 2.5 T. The plasma source is a high-power helicon source (200 kW, 13.56 MHz). The electrons will be heated via Electron Bernstein Waves with microwaves using multiple 70 GHz gyrotrons (up to 600 kW in total). Ions will be heated via ion cyclotron heating in the so-called “magnetic beach heating” scheme in the frequency range of 6–9 MHz (up to 400 kW in total). An overview of the conceptual design and the project/design requirements is given in this paper.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of 95 GHz gyrotron based on continuous operation copper solenoid with water cooling

The design work for 2nd harmonic 95 GHz, 50 kW gyrotron based on continuous operation copper solenoid is presented. Thermionic magnetron injection gun specifications were calculated according to the linear trade off equation, and simulated with CST program. Numerical code is used for cavity design using the non-uniform string equation as well as particle motion in the “cold” cavity field. The mode TE02 with low Ohmic losses in the cavity walls was chosen as the operating mode. The Solenoid is designed to induce magnetic field of 1.8 T over a length of 40 mm in the interaction region with homogeneity of ±0.34%. The solenoid has six concentric cylindrical segments (and two correction segments) of copper foil windings separated by water channels for cooling. The predicted temperature in continuous operation is below 93 °C. The parameters of the design together with simulation results of the electromagnetic cavity field, magnetic field, electron trajectories, and thermal analyses are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-AB-BRA-12: Experimental Results From the First High-Field Inline MRI-Linac

Purpose: The pursuit of real-time image guided radiotherapy using optimal tissue contrast has seen the development of several hybrid MRI-treatment systems, high field and low field, and inline and perpendicular configurations. As part of a new MRI-Linac program, an MRI scanner was integrated with a linear accelerator to enable investigations of a coupled inline MRI-Linac system. This work describes our experimental results from the first high-field inline MRI-Linac. Methods: A 1.5 Tesla magnet (Sonata, Siemens) was located in a purpose built RF cage enabling shielding from and close proximity to a linear accelerator with inline orientation. A portable linear accelerator (Linatron, Varian) was installed together with a multi-leaf collimator (Millennium, Varian) to provide dynamic field collimation and the whole assembly built onto a stainless-steel rail system. A series of MRI-Linac experiments was performed to investigate: (1) image quality with beam on measured using a macropodine (kangaroo) ex vivo phantom; (2) the noise as a function of beam state measured using a 6-channel surface coil array and; (3) electron focusing measured using GafChromic film. Results: (1) The macropodine phantom image quality with the beam on was almost identical to that with the beam off. (2) Noise measured with a surface RF coil produced a 25% elevation of background noise when the radiation beam was on. (3) Film measurements demonstrated electron focusing occurring at the center of the radiation field. Conclusion: The first high-field MRI-Linac has been built and experimentally characterized. This system has allowed us to establish the efficacy of a high field in-line MRI-Linac and study a number of the technical challenges and solutions. Supported by the Australian National Health and Medical Research Council, the Australian Research Council, the Australian Cancer Research Foundation and the Health and Hospitals Fund.

60 APPLIED LIFE SCIENCES↗

Technical Note: Experimental results from a prototype high-field inline MRI-linac

Purpose: The pursuit of real-time image guided radiotherapy using optimal tissue contrast has seen the development of several hybrid magnetic resonance imaging (MRI)-treatment systems, high field and low field, and inline and perpendicular configurations. As part of a new MRI-linac program, an MRI scanner was integrated with a linear accelerator to enable investigations of a coupled inline MRI-linac system. This work describes results from a prototype experimental system to demonstrate the feasibility of a high field inline MR-linac. Methods: The magnet is a 1.5 T MRI system (Sonata, Siemens Healthcare) was located in a purpose built radiofrequency (RF) cage enabling shielding from and close proximity to a linear accelerator with inline (and future perpendicular) orientation. A portable linear accelerator (Linatron, Varian) was installed together with a multileaf collimator (Millennium, Varian) to provide dynamic field collimation and the whole assembly built onto a stainless-steel rail system. A series of MRI-linac experiments was performed to investigate (1) image quality with beam on measured using a macropodine (kangaroo) ex vivo phantom; (2) the noise as a function of beam state measured using a 6-channel surface coil array; and (3) electron contamination effects measured using Gafchromic film and an electronic portal imaging device (EPID). Results: (1) Image quality was unaffected by the radiation beam with the macropodine phantom image with the beam on being almost identical to the image with the beam off. (2) Noise measured with a surface RF coil produced a 25% elevation of background intensity when the radiation beam was on. (3) Film and EPID measurements demonstrated electron focusing occurring along the centerline of the magnet axis. Conclusions: A proof-of-concept high-field MRI-linac has been built and experimentally characterized. This system has allowed us to establish the efficacy of a high field inline MRI-linac and study a number of the technical challenges and solutions.

60 APPLIED LIFE SCIENCES↗