Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOCALITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Quantitative estimation of localization errors of 3d transition metal pseudopotentials in diffusion Monte Carlo

The necessarily approximate evaluation of non-local pseudopotentials in diffusion Monte Carlo (DMC) introduces localization errors. In this paper, we estimate these errors for two families of non-local pseudopotentials for the first-row transition metal atoms Sc–Zn using an extrapolation scheme and multideterminant wavefunctions. Sensitivities of the error in the DMC energies to the Jastrow factor are used to estimate the quality of two sets of pseudopotentials with respect to locality error reduction. The locality approximation and T-moves scheme are also compared for accuracy of total energies. After estimating the removal of the locality and T-moves errors, we present the range of fixed-node energies between a single determinant description and a full valence multideterminant complete active space expansion. The results for these pseudopotentials agree with previous findings that the locality approximation is less sensitive to changes in the Jastrow than T-moves yielding more accurate total energies, however not necessarily more accurate energy differences. For both the locality approximation and T-moves, we find decreasing Jastrow sensitivity moving left to right across the series Sc–Zn. The recently generated pseudopotentials of Krogel et al. reduce the magnitude of the locality error compared with the pseudopotentials of Burkatzki et al. by an average estimated 40% using the locality approximation. The estimated locality error is equivalent for both sets of pseudopotentials when T-moves is used. Finally, for the Sc–Zn atomic series with these pseudopotentials, and using up to three-body Jastrow factors, our results suggest that the fixed-node error is dominant over the locality error when a single determinant is used.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Classifying photonic topology using the spectral localizer and numerical K -theory

Recently, the spectral localizer framework has emerged as an efficient approach for classifying topology in photonic systems featuring local nonlinearities and radiative environments. In nonlinear systems, this framework provides rigorous definitions for concepts such as topological solitons and topological dynamics, where a system’s occupation induces a local change in its topology due to nonlinearity. For systems embedded in radiative environments that do not possess a shared bulk spectral gap, this framework enables the identification of local topology and shows that local topological protection is preserved despite the lack of a common gap. However, as the spectral localizer framework is rooted in the mathematics of C*-algebras, and not vector bundles, understanding and using this framework requires developing intuition for a somewhat different set of underlying concepts than those that appear in traditional approaches for classifying material topology. In this tutorial, we introduce the spectral localizer framework from a ground-up perspective and provide physically motivated arguments for understanding its local topological markers and associated local measure of topological protection. In doing so, we provide numerous examples of the framework’s application to a variety of topological classes, including crystalline and higher-order topology. We then show how Maxwell’s equations can be reformulated to be compatible with the spectral localizer framework, including the possibility of radiative boundary conditions. To aid in this introduction, we also provide a physics-oriented introduction to multi-operator pseudospectral methods and numerical K-theory, two mathematical concepts that form the foundation for the spectral localizer framework. Finally, we provide some mathematically oriented comments on the C*-algebraic origins of this framework, including a discussion of real C*-algebras and graded C*-algebras that are necessary for incorporating physical symmetries. Looking forward, we hope that this tutorial will serve as an approachable starting point for learning the foundations of the spectral localizer framework.

97 MATHEMATICS AND COMPUTING↗

The principle of locality: Effectiveness, fate, and challenges

The special theory of relativity and quantum mechanics merge in the key principle of quantum field theory, the principle of locality. We review some examples of its 'unreasonable effectiveness' in giving rise to most of the conceptual and structural frame of quantum field theory, especially in the absence of massless particles. This effectiveness shows up best in the formulation of quantum field theory in terms of operator algebras of local observables; this formulation is successful in digging out the roots of global gauge invariance, through the analysis of superselection structure and statistics, in the structure of the local observable quantities alone, at least for purely massive theories; but so far it seems unfit to cope with the principle of local gauge invariance. This problem emerges also if one attempts to figure out the fate of the principle of locality in theories describing the gravitational forces between elementary particles as well. An approach based on the need to keep an operational meaning, in terms of localization of events, of the notion of space-time, shows that, in the small, the latter must loose any meaning as a classical pseudo-Riemannian manifold, locally based on Minkowski space, but should acquire a quantum structure at the Planck scale. We review the geometry of a basic model of quantum space-time and some attempts to formulate interaction of quantum fields on quantum space-time. The principle of locality is necessarily lost at the Planck scale, and it is a crucial open problem to unravel a replacement in such theories which is equally mathematically sharp, namely, a principle where the general theory of relativity and quantum mechanics merge, which reduces to the principle of locality at larger scales. Besides exploring its fate, many challenges for the principle of locality remain; among them, the analysis of superselection structure and statistics also in the presence of massless particles, and to give a precise mathematical formulation to the measurement process in local and relativistic terms; for which we outline a qualitative scenario which avoids the Einstein, Podolski, and Rosen paradox.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Maximally-localized position, Euclidean path-integral, and thermodynamics in GUP quantum mechanics

In dealing with quantum mechanics at very high energies, it is essential to adapt to a quasiposition representation using the maximally-localized states because of the generalized uncertainty principle. In this paper, we look at maximally-localized states as eigenstates of the operator ξ=X+iβP that we refer to as the maximally-localized position. We calculate the overlap between maximally-localized states and show that the identity operator can be expressed in terms of the maximally-localized states. Furthermore, we show that the maximally-localized position is diagonal in momentum-space and that the maximally-localized position and its adjoint satisfy commutation and anti-commutation relations reminiscent of the harmonic oscillator commutation and anti-commutation relations. As application, we use the maximally-localized position in developing the Euclidean path-integral and introduce the compact form of the propagator for maximal localization. The free particle momentum-space propagator and the propagator for maximal localization are analytically evaluated up to quadratic-order in β. Finally, we obtain a path-integral expression for the partition function of a thermodynamic system using the maximally-localized states. The partition function of a gas of noninteracting particles is evaluated. At temperatures exceeding the Planck energy, we obtain the gas’ maximum internal energy N∕2β and recover the zero heat capacity of an ideal gas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cdc6 localizes to S- and G2-phase centrosomes in a cell cycle-dependent manner

Highlights: • Cdc6 protein is a component of the pre-replicative complex required for chromosomal replication initiation. • Cdc6 localized to centrosomes of S and G2 phases in a cell cycle-dependent manner. • The centrosomal localization was governed by centrosomal localization signal sequences of Cdc6. • Deletions or substitution mutations on the centrosomal localization signal interfered with centrosomal localization of the Cdc6 proteins. - Abstract: The Cdc6 protein has been primarily investigated as a component of the pre-replicative complex for the initiation of chromosome replication, which contributes to maintenance of chromosomal integrity. Here, we show that Cdc6 localized to the centrosomes during S and G2 phases of the cell cycle. The centrosomal localization was mediated by Cdc6 amino acid residues 311–366, which are conserved within other Cdc6 homologues and contains a putative nuclear export signal. Deletions or substitutions of the amino acid residues did not allow the proteins to localize to centrosomes. In contrast, DsRed tag fused to the amino acid residues localized to centrosomes. These results indicated that a centrosome localization signal is contained within amino acid residues 311–366. The cell cycle-dependent centrosomal localization of Cdc6 in S and G2 phases suggest a novel function of Cdc6 in centrosomes.

60 APPLIED LIFE SCIENCES↗

Cellular localization of ATBF1 protein and its functional implication in breast epithelial cells

ATBF1, a large transcription factor, was normally localized in nuclei, and its mislocalization to cytoplasm was reported in multiple cancers. However, localization of ATBF1 in breast epithelial cells and its potential functions were unknown. Here, we investigated ATBF1 localization via immunofluorescence staining in different kinds of breast epithelial cells. In MCF10A cells and normal mice mammary gland tissues, ATBF1 was mainly localized in nuclei. Knockdown of ATBF1 expression in MCF10A cells by siRNA promoted cell proliferation. Moreover, ATBF1 was co-localized with chromosome during mitosis, indicating its potential function in mitosis. In an estrogen receptor (ER)-positive breast cancer cell line (MCF7), estrogen induced ATBF1 translocation from cytoplasm to nuclei in an ER dependent pathway. In ER-negative cells (Hs578T and MDA-MB-231), ATBF1 was co-localized with GM130 in cytoplasm, indicating ATBF1 localization was associated with protein modification in golgi body. The results were beneficial for intensive investigation of ATBF1's function with different cellular localization in breast cancer. - Highlights: • Cellular localization of ATBF1 is correlated with its function in breast cancer. • Nuclear ATBF1 was co-localized with chromosome during mitosis normally. • Estrogen induced translocation of cytoplasmic ATBF1 to nuclei in MCF7. • Translocation of ATBF1 in ER{sup +} breast cancer cells was ER dependent. • Cytoplasmic ATBF1 was co-localized with golgi body in ER{sup −} breast cancer cells.

60 APPLIED LIFE SCIENCES↗

Correlation of Local Failure With Measures of Dose Insufficiency in the High-Dose Single-Fraction Treatment of Bony Metastases

Purpose: In the setting of high-dose single-fraction image-guided radiotherapy of spine metastases, the delivered dose is hypothesized to be a significant factor in local control. We investigated the dependence of local control on measures of dose insufficiency. Methods and Materials: The minimum doses received by the hottest 100%, 98%, and 95% (D{sub min}, D{sub 98}, and D{sub 95}) of the gross target volume (GTV) were computed for 91 consecutively treated lesions observed in 79 patients. Prescribed doses of 18-24 Gy were delivered in a single fraction. The spinal cord and cauda equina were constrained to a maximum dose of 12-14 Gy and 16 Gy, respectively. A rank-sum test was used to assess the differences between radiographic local failure and local control. Results: With a median follow-up of 18 months, seven local failures have occurred. The distributions of GTV D{sub min}, D{sub 98}, and D{sub 95} for treatments resulting in local failure were found to be statistically different from the corresponding distributions of the patient group as a whole. Taking no account of histology, p values calculated for D{sub min}, D{sub 98}, and D{sub 95} were 0.004, 0.012, and 0.031, respectively. No correlations between local failure and target volume or between local failure and anatomic location were found. Conclusions: The results indicate that D{sub min}, D{sub 98}, and D{sub 95} may be important risk factors for local failure. No local failures in any histology were observed when D{sub min} was >15 Gy, suggesting that this metric may be an important predictor of local control.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Local Setup Errors in Image-Guided Radiotherapy for Head and Neck Cancer Patients Immobilized With a Custom-Made Device

Purpose: To evaluate the local positioning uncertainties during fractionated radiotherapy of head-and-neck cancer patients immobilized using a custom-made fixation device and discuss the effect of possible patient correction strategies for these uncertainties. Methods and Materials: A total of 45 head-and-neck patients underwent regular control computed tomography scanning using an in-room computed tomography scanner. The local and global positioning variations of all patients were evaluated by applying a rigid registration algorithm. One bounding box around the complete target volume and nine local registration boxes containing relevant anatomic structures were introduced. The resulting uncertainties for a stereotactic setup and the deformations referenced to one anatomic local registration box were determined. Local deformations of the patients immobilized using our custom-made device were compared with previously published results. Several patient positioning correction strategies were simulated, and the residual local uncertainties were calculated. Results: The patient anatomy in the stereotactic setup showed local systematic positioning deviations of 1-4 mm. The deformations referenced to a particular anatomic local registration box were similar to the reported deformations assessed from patients immobilized with commercially available Aquaplast masks. A global correction, including the rotational error compensation, decreased the remaining local translational errors. Depending on the chosen patient positioning strategy, the remaining local uncertainties varied considerably. Conclusions: Local deformations in head-and-neck patients occur even if an elaborate, custom-made patient fixation method is used. A rotational error correction decreased the required margins considerably. None of the considered correction strategies achieved perfect alignment. Therefore, weighting of anatomic subregions to obtain the optimal correction vector should be investigated in the future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predictors of Individual Tumor Local Control After Stereotactic Radiosurgery for Non-Small Cell Lung Cancer Brain Metastases

Purpose: To evaluate local control rates and predictors of individual tumor local control for brain metastases from non-small cell lung cancer (NSCLC) treated with stereotactic radiosurgery (SRS). Methods and Materials: Between June 1998 and May 2011, 401 brain metastases in 228 patients were treated with Gamma Knife single-fraction SRS. Local failure was defined as an increase in lesion size after SRS. Local control was estimated using the Kaplan-Meier method. The Cox proportional hazards model was used for univariate and multivariate analysis. Receiver operating characteristic analysis was used to identify an optimal cutpoint for conformality index relative to local control. A P value <.05 was considered statistically significant. Results: Median age was 60 years (range, 27-84 years). There were 66 cerebellar metastases (16%) and 335 supratentorial metastases (84%). The median prescription dose was 20 Gy (range, 14-24 Gy). Median overall survival from time of SRS was 12.1 months. The estimated local control at 12 months was 74%. On multivariate analysis, cerebellar location (hazard ratio [HR] 1.94, P=.009), larger tumor volume (HR 1.09, P<.001), and lower conformality (HR 0.700, P=.044) were significant independent predictors of local failure. Conformality index cutpoints of 1.4-1.9 were predictive of local control, whereas a cutpoint of 1.75 was the most predictive (P=.001). The adjusted Kaplan-Meier 1-year local control for conformality index ≥1.75 was 84% versus 69% for conformality index <1.75, controlling for tumor volume and location. The 1-year adjusted local control for cerebellar lesions was 60%, compared with 77% for supratentorial lesions, controlling for tumor volume and conformality index. Conclusions: Cerebellar tumor location, lower conformality index, and larger tumor volume were significant independent predictors of local failure after SRS for brain metastases from NSCLC. These results warrant further investigation in a prospective setting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnitude of pseudopotential localization errors in fixed node diffusion quantum Monte Carlo

Growth in computational resources has lead to the application of real space diffusion quantum Monte Carlo to increasingly heavy elements. Although generally assumed to be small, we find that when using standard techniques, the pseudopotential localization error can be large, on the order of an electron volt for an isolated cerium atom. We formally show that the localization error can be reduced to zero with improvements to the Jastrow factor alone, and we define a metric of Jastrow sensitivity that may be useful in the design of pseudopotentials. We employ an extrapolation scheme to extract the bare fixed node energy and estimate the localization error in both the locality approximation and the T-moves schemes for the Ce atom in charge states 3+/4+. The locality approximation exhibits the lowest Jastrow sensitivity and generally smaller localization errors than T-moves although the locality approximation energy approaches the localization free limit from above/below for the 3+/4+ charge state. We find that energy minimized Jastrow factors including three-body electron-electron-ion terms are the most effective at reducing the localization error for both the locality approximation and T-moves for the case of the Ce atom. Less complex or variance minimized Jastrows are generally less effective. Finally, our results suggest that further improvements to Jastrow factors and trial wavefunction forms may be needed to reduce localization errors to chemical accuracy when medium core pseudopotentials are applied to heavy elements such as Ce.

36 MATERIALS SCIENCE↗

Error analysis of marker-based object localization using a single-plane XRII

The role of imaging and image guidance is increasing in surgery and therapy, including treatment planning and follow-up. Fluoroscopy is used for two-dimensional (2D) guidance or localization; however, many procedures would benefit from three-dimensional (3D) guidance or localization. Three-dimensional computed tomography (CT) using a C-arm mounted x-ray image intensifier (XRII) can provide high-quality 3D images; however, patient dose and the required acquisition time restrict the number of 3D images that can be obtained. C-arm based 3D CT is therefore limited in applications for x-ray based image guidance or dynamic evaluations. 2D-3D model-based registration, using a single-plane 2D digital radiographic system, does allow for rapid 3D localization. It is our goal to investigate - over a clinically practical range - the impact of x-ray exposure on the resulting range of 3D localization precision. In this paper it is assumed that the tracked instrument incorporates a rigidly attached 3D object with a known configuration of markers. A 2D image is obtained by a digital fluoroscopic x-ray system and corrected for XRII distortions ({+-}0.035 mm) and mechanical C-arm shift ({+-}0.080 mm). A least-square projection-Procrustes analysis is then used to calculate the 3D position using the measured 2D marker locations. The effect of x-ray exposure on the precision of 2D marker localization and on 3D object localization was investigated using numerical simulations and x-ray experiments. The results show a nearly linear relationship between 2D marker localization precision and the 3D localization precision. However, a significant amplification of error, nonuniformly distributed among the three major axes, occurs, and that is demonstrated. To obtain a 3D localization error of less than {+-}1.0 mm for an object with 20 mm marker spacing, the 2D localization precision must be better than {+-}0.07 mm. This requirement was met for all investigated nominal x-ray exposures at 28 cm FOV, and for all but the lowest two at 40 cm FOV. However, even for those two nominal exposures, the expected 3D localization error is less than {+-}1.2 mm. The tracking precision was {+-}0.65 mm for the out-of-plane translations, {+-}0.05 mm for in-plane translations, and {+-}0.05 deg. for the rotations. The root mean square (RMS) difference between the true and projection-Procrustes calculated location was 1.07 mm. It is believed these results show the potential of this technique for dynamic evaluations or real-time image guidance using a single x-ray source and XRII detector.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Feasibility of using cone-beam CT to verify and reposition the optically guided target localization of linear accelerator based stereotactic radiosurgery

Purpose: The optically guided target localization had been developed for linear accelerator based stereotactic radiosurgery (SRS). Unlike the traditional laser localization, the optical guided target localization utilizes a digital system to position patient. Although the system has been proven accurate and robust, it takes away the capability of physicist to directly double check the target position prior to irradiation. Any error from system calibration, data transformation, or head ring position maintenance will not be caught. The purpose of this work is to investigate the possibility of using cone-beam CT (CBCT) to double check the optically guided SRS target localization and reposition the patient. Methods: A SRS quality assurance (QA) phantom was used in the study. The phantom mounted with SRS head frame was scanned by computer tomography (CT) and planned according to the SRS radiation treatment planning process. A target isocenter is defined and transferred to the optically guided target localization system. The phantom was then transported to the linear accelerator room and localized at the initial position agreed by the optically guided target localization system and the CBCT system. Tests were conducted by moving/rotating the phantom to a set of preset offsets and taking CBCT images. Shifts detected by CBCT were compared with the preset offsets. Agreements between them were studied to see how well the CBCT was in discovering the optically guided target localization error. Results: Experiment results demonstrated good agreement between the CBCT detected phantom shift and the preset offset, when the offset is above 1 mm shift or 0.2 degree rotation. Offset less than 1 mm shift or 0.2 degree rotation was not detectable by CBCT. Conclusions: The study concludes that the CBCT is able to discover the optically guided target localization error due to the system calibration or had ring migration. It is a valuable second check tool for SRS target localization quality assurance. The accuracy of CBCT in estimating patient positioning deviation satisfies the SRS procedures with generous tumor size and margin that can tolerate 1 mm or 0.2 degree accuracy. This avoids sending patient home without treatment. CBCT can be neither used as a primary SRS target localization nor can it be used to reposition the patient that cannot tolerate 1 mm shift or 0.2 degree rotation.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP2-05: Effect of Localizer Type and Patient Off-Centering On CT Radiation Dose with Use of Automatic Tube Current Modulation

Purpose: Apparent patient size in CT localizers varies with localizer type and patient positioning, resulting in variation in effective mAs as guided by Tube Current Modulation (TCM). Our aim was to investigate the effects of vertical off-centering on CTDI-vol when using different localizer types and TCM strengths. Methods: A CTDI body phantom was scanned using an abdominal protocol with three TCM strengths (Siemens Definition AS40, CAREDose4D; very weak, average, very strong). Data was acquired at 11 table height positions; with phantom center at isocenter and at 10 other positions between 142mm below and 53mm above. At each position, scans were acquired using 5 different localizer types: PA, AP, Lateral, PA+Lateral, and Lateral+PA. CTDI-vol was recorded for the 165 combinations of table height, localizer type, and TCM strength, and magnification factors measured from localizer images. Results: Magnification factors from AP and PA localizers ranged from 0.79–1.11 and 1.35–0.91, respectively from lowest to highest positions (highest with phantom located closest to X-ray tube), with a smaller impact when using Lateral, PA+Lateral, Lateral+PA localizer types, all of which behaved similarly. For an average TCM strength and PA localizer, CTDI-vol ranged from 75% higher to 12% lower than the isocenter value for the lowest to highest table positions, respectively. For table positions ranging from lowest to highest, CTDI-vol ranged from −23% to 17% for AP, from −8% to 0.3% for lateral and from −7% to 1% for a combination of PA and Lateral in either order. Similar behavior was found for different TCM strengths, but effects were more pronounced for very strong compared with very weak modulation strengths. Conclusion: Patient off-centering substantially impacts radiation dose, which depends on the amount of vertical offcentering and type of the localizer used. The combination of PA and Lateral localizers is most robust against effects of patient off-centering.

60 APPLIED LIFE SCIENCES↗

An explainable variational autoencoder model for three-dimensional acoustic emission source localization in hollow cylindrical structures

We introduce an explainable variational autoencoder for three-dimensional (3D) localization of acoustic emission sources in hollow cylindrical structures, with an unsupervised approach. This research capitalizes on multi-arrival waveforms generated by helical path propagation in cylindrical geometries to enable efficient two-receiver localization. By integrating the modal characteristics of Lamb modes under multi-path conditions, we demonstrate that two sets of time-of-arrival differences and peak amplitudes extracted from one receiver can serve as effective localization features. This initial approach identifies four potential source locations, highlighting the feasibility of two-receiver source localization using traditional feature extraction methods. However, direct extraction can be challenging when mode overlaps occur, complicating the localization process. To address this, our work proposes a novel waveform-based method. This method leverages the consistent dispersion characteristics within isotropic materials, where each unique combination of mode arrival times and peak amplitudes constructs a distinct waveform. This distinctiveness overcomes the ambiguities associated with mode overlaps, significantly enhancing the method’s precision and robustness. Our approach adopts a data-driven strategy for waveform-based localization using variational autoencoder (VAE). VAE discerns waveform patterns for localization, while also addressing data uncertainties. The VAE’s encoder and decoder networks capture the localization process and the source’s influence on waveform generation, respectively, guiding latent variables to segregate waveforms by source in the latent space. The design of the learning process focuses on specific localization characteristics to enhance result explainability. Localization predictions are generated by projecting test waveforms, not included in the training set, onto a trained latent space. The prediction is determined using a nearest-neighbor approach based on the closest latent representation of a source. Validation with pencil-lead-break tests on a metallic pipe confirmed our method’s effectiveness, achieving an averaged 3D localization accuracy of 0.84.

Lee, Guan-Wei↗

Systematic Quantum Cluster Typical Medium Method for the Study of Localization in Strongly Disordered Electronic Systems

Great progress has been made in recent years towards understanding the properties of disordered electronic systems. In part, this is made possible by recent advances in quantum effective medium methods which enable the study of disorder and electron-electronic interactions on equal footing. They include dynamical mean-field theory and the Coherent Potential Approximation, and their cluster extension, the dynamical cluster approximation. Despite their successes, these methods do not enable the first-principles study of the strongly disordered regime, including the effects of electronic localization. The main focus of this review is the recently developed typical medium dynamical cluster approximation for disordered electronic systems. This method has been constructed to capture disorder-induced localization and is based on a mapping of a lattice onto a quantum cluster embedded in an effective typical medium, which is determined self-consistently. Unlike the average effective medium-based methods mentioned above, typical medium-based methods properly capture the states localized by disorder. The typical medium dynamical cluster approximation not only provides the proper order parameter for Anderson localized states, but it can also incorporate the full complexity of Density-Functional Theory (DFT)-derived potentials into the analysis, including the effect of multiple bands, non-local disorder, and electron-electron interactions. After a brief historical review of other numerical methods for disordered systems, we discuss coarse-graining as a unifying principle for the development of translationally invariant quantum cluster methods. Together, the Coherent Potential Approximation, the Dynamical Mean-Field Theory and the Dynamical Cluster Approximation may be viewed as a single class of approximations with a much-needed small parameter of the inverse cluster size which may be used to control the approximation. We then present an overview of various recent applications of the typical medium dynamical cluster approximation to a variety of models and systems, including single and multiband Anderson model, and models with local and off-diagonal disorder. We then present the application of the method to realistic systems in the framework of the DFT and demonstrate that the resulting method can provide a systematic first-principles method validated by experiment and capable of making experimentally relevant predictions. We also discuss the application of the typical medium dynamical cluster approximation to systems with disorder and electron-electron interactions. Most significantly, we show that in the limits of strong disorder and weak interactions treated perturbatively, that the phenomena of 3D localization, including a mobility edge, remains intact. However, the metal-insulator transition is pushed to larger disorder values by the local interactions. We also study the limits of strong disorder and strong interactions capable of producing moment formation and screening, with a non-perturbative local approximation. Here, we find that the Anderson localization quantum phase transition is accompanied by a quantum-critical fan in the energy-disorder phase diagram.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lysine 271 but not lysine 210 of XRCC4 is required for the nuclear localization of XRCC4 and DNA ligase IV

XRCC4 and DNA Ligase IV (LIG4) cooperate to join two DNA ends at the final step of DNA double-strand break (DSB) repair through non-homologous end-joining (NHEJ). However, it is not fully understood how these proteins are localized to the nucleus. Here we created XRCC4{sup K271R} mutant, as Lys271 lies within the putative nuclear localization signal (NLS), and XRCC4{sup K210R} mutant, as Lys210 was reported to undergo SUMOylation, implicated in the nuclear localization of XRCC4. Wild-type and mutated XRCC4 with EGFP tag were introduced into HeLa cell, in which endogenous XRCC4 had been knocked down using siRNA directed to 3′-untranslated region, and tested for the nuclear localization function by fluorescence microscopy. XRCC4{sup K271R} was defective in the nuclear localization of itself and LIG4, whereas XRCC4{sup K210R} was competent for the nuclear localization with LIG4. To examine DSB repair function, wild-type and mutated XRCC4 were introduced into XRCC4-deficient M10. M10-XRCC4{sup K271R}, but not M10-XRCC4{sup K210R}, showed significantly reduced surviving fraction after 2 Gy γ-ray irradiation as compared to M10-XRCC4{sup WT}. The number of γ-H2AX foci remaining 2 h after 2 Gy γ-ray irradiation was significantly greater in M10-XRCC4{sup K271R} than in M10-XRCC4{sup WT}, whereas it was only marginally increased in M10-XRCC4{sup K210R} as compared to M10-XRCC4{sup WT}. The present results collectively indicated that Lys271, but not Lys210, of XRCC4 is required for the nuclear localization of XRCC4 and LIG4 and that the nuclear localizing ability is essential for DSB repair function of XRCC4. - Highlights: • XRCC4{sup K271R} is defective in the nuclear localization of itself and LIG4. • XRCC4{sup K210R} is competent for the nuclear localization of itself and LIG4. • XRCC4{sup K271R} is deficient in DSB repair function. • XRCC4{sup K210R} is mostly normal in DSB repair function.

60 APPLIED LIFE SCIENCES↗

Quantifying Local Radiation-Induced Lung Damage From Computed Tomography

Purpose: Optimal implementation of new radiotherapy techniques requires accurate predictive models for normal tissue complications. Since clinically used dose distributions are nonuniform, local tissue damage needs to be measured and related to local tissue dose. In lung, radiation-induced damage results in density changes that have been measured by computed tomography (CT) imaging noninvasively, but not yet on a localized scale. Therefore, the aim of the present study was to develop a method for quantification of local radiation-induced lung tissue damage using CT. Methods and Materials: CT images of the thorax were made 8 and 26 weeks after irradiation of 100%, 75%, 50%, and 25% lung volume of rats. Local lung tissue structure (S{sub L}) was quantified from local mean and local standard deviation of the CT density in Hounsfield units in 1-mm{sup 3} subvolumes. The relation of changes in S{sub L} (DELTAS{sub L}) to histologic changes and breathing rate was investigated. Feasibility for clinical application was tested by applying the method to CT images of a patient with non-small-cell lung carcinoma and investigating the local dose-effect relationship of DELTAS{sub L}. Results: In rats, a clear dose-response relationship of DELTAS{sub L} was observed at different time points after radiation. Furthermore, DELTAS{sub L} correlated strongly to histologic endpoints (infiltrates and inflammatory cells) and breathing rate. In the patient, progressive local dose-dependent increases in DELTAS{sub L} were observed. Conclusion: We developed a method to quantify local radiation-induced tissue damage in the lung using CT. This method can be used in the development of more accurate predictive models for normal tissue complications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Local conservation of energy in fully implicit PIC algorithms

We consider the issue of strict, fully discrete local energy conservation for a whole class of fully implicit local-charge- and global-energy-conserving particle-in-cell (PIC) algorithms. Earlier studies demonstrated these algorithms feature strict global energy conservation. However, whether a local energy conservation theorem exists (in which the local energy update is governed by a flux balance equation at every mesh cell) for these schemes is unclear. In this study, we show that a local energy conservation theorem indeed exists. We begin our analysis with the 1D electrostatic PIC model without orbit-averaging, and then generalize our conclusions to account for orbit averaging, multiple dimensions, and electromagnetic models (Darwin). In all cases, a temporally, spatially, and particle-discrete local energy conservation theorem is shown to exist, proving that these formulations (as originally proposed in the literature), in addition to being locally charge conserving and globally energy conserving, are strictly locally energy conserving as well. In contrast to earlier proofs of local conservation in the literature, which only considered continuum time, our result is valid for the fully implicit time-discrete version of all models considered, including important features such as orbit averaging. We demonstrate the local-energy-conservation property numerically with a paradigmatic numerical example.

97 MATHEMATICS AND COMPUTING↗