Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linearization error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Beam Dynamics Study of PIP-II Superconducting Linac in the Presence of Misalignment Errors

The Proton Improvement Plan (PIP)-II is a proposed high intensity proton facility being developed at the Fermilab. The PIP-II is primarily based on construction of a new superconducting radio frequency (SRF) linear accelerator (linac) that would deliver an average beam current of 2mA with output energy up to 800 MeV. The linac performance is mainly determined by beam sensitivity against various component errors. These errors trigger not only emittance dilution but also a beam loss in worst cases. This paper discusses effects of component misalignments on the beam and presents alignment budget for the PIP-II SRF linac.

43 PARTICLE ACCELERATORS↗

Cone Beam Computed Tomography Number Errors and Consequences for Radiotherapy Planning: An Investigation of Correction Methods

Purpose: The potential of keV cone beam computed tomography (CBCT) for guiding adaptive replanning is well-known. There are impediments to this, one being CBCT number accuracy. The purpose of this study was to investigate CBCT number correction methods and the affect of residual inaccuracies on dose deposition. Four different correction strategies were applied to the same patient data to compare performance and the sophistication of correction-method needed for acceptable dose errors. Methods and Materials: Planning CT and CBCT reconstructions were used for 12 patients (6 brain, 3 prostate, and 3 bladder cancer patients). All patients were treated using Elekta linear accelerators and XVI imaging systems. Two of the CBCT number correction methods investigated were based on an algorithm previously proposed by the authors but only previously applied to phantoms. Two further methods, based on an approach previously suggested in the research literature, were also examined. Dose calculations were performed using scans of a 'worst' subset of patients using the Pinnacle{sup 3} version 9.0 treatment planning system and the patients' clinical plans. Results: All mean errors in CBCT number were <50 HU, and all correction methods performed well or adequately in dose calculations. The worst single dose discrepancy identified for any of the examined methods or patients was 3.0%. Mean errors in the doses to treatment volumes or organs at risk were negatively correlated with the mean error in CT number. That is, a mean CT number that was too large, averaged over the entire CBCT volume, implied an underdosing in a volume-of-interest and vice versa. Conclusions: Results suggest that (1) the correction of CBCT numbers to within a mean error of 50 HU in the scan volume provides acceptable discrepancies in dose (<3%) and (2) this is achievable with even quite unsophisticated correction methods.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laser Phase Errors in Seeded Free Electron Lasers

Harmonic seeding of free electron lasers has attracted significant attention as a method for producing transform-limited pulses in the soft x-ray region. Harmonic multiplication schemes extend seeding to shorter wavelengths, but also amplify the spectral phase errors of the initial seed laser, and may degrade the pulse quality and impede production of transform-limited pulses. In this paper we consider the effect of seed laser phase errors in high gain harmonic generation and echo-enabled harmonic generation. We use simulations to confirm analytical results for the case of linearly chirped seed lasers, and extend the results for arbitrary seed laser envelope and phase.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantifying the generalization error in deep learning in terms of data distribution and neural network smoothness

We report the accuracy of deep learning, i.e., deep neural networks, can be characterized by dividing the total error into three main types: approximation error, optimization error, and generalization error. Whereas there are some satisfactory answers to the problems of approximation and optimization, much less is known about the theory of generalization. Most existing theoretical works for generalization fail to explain the performance of neural networks in practice. To derive a meaningful bound, we study the generalization error of neural networks for classification problems in terms of data distribution and neural network smoothness. We introduce the cover complexity (CC) to measure the difficulty of learning a data set and the inverse of the modulus of continuity to quantify neural network smoothness. A quantitative bound for expected accuracy/error is derived by considering both the CC and neural network smoothness. Although most of the analysis is general and not specific to neural networks, we validate our theoretical assumptions and results numerically for neural networks by several data sets of images. The numerical results confirm that the expected error of trained networks scaled with the square root of the number of classes has a linear relationship with respect to the CC. We also observe a clear consistency between test loss and neural network smoothness during the training process. In addition, we demonstrate empirically that the neural network smoothness decreases when the network size increases whereas the smoothness is insensitive to training dataset size.

97 MATHEMATICS AND COMPUTING↗

Linear point and sound horizon as purely geometric standard rulers

The baryon acoustic oscillations feature (BAO) imprinted in the clustering correlation function is known to furnish us cosmic distance determinations that are independent of the cosmological-background model and the primordial perturbation parameters. These measurements can be accomplished rigorously by means of the purely geometric BAO methods. To date two different purely geometric BAO approaches have been proposed. The first exploits the linear-point standard ruler. The second, called correlation-function model-fitting, exploits the sound-horizon standard ruler. A key difference between them is that, when estimated from clustering data, the linear point makes use of a cosmological-model-independent procedure to extract the ratio of the ruler to the cosmic distance, while the correlation-function model-fitting relies on a phenomenological cosmological model for the correlation function. Nevertheless the two rulers need to be precisely defined independently of any specific observable (e.g., the BAO). We define the linear point and sound horizon and we fully characterize and compare the two rulers’ cosmological-parameter dependence. We find that they are both geometrical (i.e., independent of the primordial cosmological parameters) within the required accuracy, and that they have the same parameter dependence for a wide range of parameter values. We estimate the rulers’ best-fit values and errors, given the cosmological constraints obtained by the Planck Satellite team from their measurements of the cosmic microwave background temperature and polarization anisotropies. We do this for three different cosmological models encompassed by the purely geometric BAO methods. In each case we find that the relative errors of the two rulers coincide and they are insensitive to the assumed cosmological model. Interestingly both the linear point and the sound horizon shift by 0.5σ when we do not fix the spatial geometry to be flat in Λ CDM. Finally, this points toward a sensitivity of the rulers to different cosmological models when they are estimated from the cosmic microwave background.

79 ASTRONOMY AND ASTROPHYSICS↗

Deterministic polarization-entanglement purification using spatial entanglement

We present an efficient entanglement purification protocol with hyperentanglement in which additional spatial entanglement is utilized to purify the two-particle polarization-entangled state. The bit-flip error and phase-flip error can be corrected and eliminated in one step. Two remote parties can obtain maximally entangled polarization states deterministically and only passive linear optics are employed. We also discuss the protocol with practical quantum source and noisy channel.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical metrology at the NSLS-II

Rapid progress in synchrotron optics performance places a high demand on optical characterization techniques used to validate surface parameters prior to installation of the X-ray optics. It is now necessary to characterize optical surface figure and slope errors and roughness on meter-long optics over spatial frequencies as short as 0.1 {micro}m The new NSLS-II Optical Metrology Laboratory (OML) includes instruments for measuring: (1) long spatial frequency figure errors with a ZYGO MST Fizeau-type 4* interferometer, capable of 0.1 nm sensitivity, (2) mid spatial frequencies with an upgraded ZYGO NewView 6300 white light interferometric microscope, capable of reaching 0.1 nm accuracy at a lateral resolution of 1 {micro}m, (3) high frequency roughness with an AFM (Nanosurf AG) with linearity better than 0.2% over the 80 {micro}m measurement area and sensitivity approaching 0.01 nm, and (4) slope errors with a long trace profiler currently under development that will be able to reach 50 nrad slope error accuracy. At present, the OML supports the NSLS-II R&D efforts and provides ongoing testing for NSLS optics. Future plans include the construction of a specialized metrology beamline for at-wavelength metrology, radiometry, in situ surface figuring, crystal optics characterization, and instrumentation development.

43 PARTICLE ACCELERATORS↗

Effect of Various Errors on the Spin Tune and Stable Spin Axis

Even though RHIC has two full Siberian snakes in each ring, there are various perturbations to the ideal case including orbit errors at the snakes, experiment solenoids, injection bumps, and interlaced horizontal-vertical bumps at the hydrogen jet polarimeter. These errors can cause depolarization by shifting the spin tune and tilting the stable spin direction away from vertical. Tilting of the stable spin axis can enhance horizontal depolarizing resonances. This paper presents preliminary results for some of these error scenarios, as well as their impact on the stable spin directions at STAR and PHENIX.

43 PARTICLE ACCELERATORS↗

How noise affects quantum detector tomography

We determine the full photon number response of a NbN superconducting nanowire single photon detector via quantum detector tomography, and the results show the separation of linear, effective absorption efficiency from the internal detection efficiencies. In addition, we demonstrate an error budget for the complete quantum characterization of the detector. We find that for short times, the dominant noise source is shot noise, while laser power fluctuations limit the accuracy for longer timescales. The combined standard uncertainty of the internal detection efficiency derived from our measurements is about 2%.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A high-fidelity realization of the Euclid code comparison N-body simulation with Abacus

Abstract We present a high-fidelity realization of the cosmological N-body simulation from the Schneider et al. code comparison project. The simulation was performed with our AbacusN-body code, which offers high-force accuracy, high performance, and minimal particle integration errors. The simulation consists of 20483 particles in a $500\ h^{-1}\, \mathrm{Mpc}$ box for a particle mass of $1.2\times 10^9\ h^{-1}\, \mathrm{M}_\odot$ with $10\ h^{-1}\, \mathrm{kpc}$ spline softening. Abacus executed 1052 global time-steps to z = 0 in 107 h on one dual-Xeon, dual-GPU node, for a mean rate of 23 million particles per second per step. We find Abacus is in good agreement with Ramses and Pkdgrav3 and less so with Gadget3. We validate our choice of time-step by halving the step size and find sub-percent differences in the power spectrum and 2PCF at nearly all measured scales, with ${\lt }0.3{{\ \rm per\ cent}}$ errors at $k\lt 10\ \mathrm{Mpc}^{-1}\, h$. On large scales, Abacus reproduces linear theory better than 0.01 per cent. Simulation snapshots are available at http://nbody.rc.fas.harvard.edu/public/S2016.

79 ASTRONOMY AND ASTROPHYSICS↗

Figures of merit for present and future dark energy probes

We compare current and forecasted constraints on dynamical dark energy models from Type Ia supernovae and the cosmic microwave background using figures of merit based on the volume of the allowed dark energy parameter space. For a two-parameter dark energy equation of state that varies linearly with the scale factor, and assuming a flat universe, the area of the error ellipse can be reduced by a factor of {approx}10 relative to current constraints by future space-based supernova data and CMB measurements from the Planck satellite. If the dark energy equation of state is described by a more general basis of principal components, the expected improvement in volume-based figures of merit is much greater. While the forecasted precision for any single parameter is only a factor of 2-5 smaller than current uncertainties, the constraints on dark energy models bounded by -1{<=}w{<=}1 improve for approximately 6 independent dark energy parameters resulting in a reduction of the total allowed volume of principal component parameter space by a factor of {approx}100. Typical quintessence models can be adequately described by just 2-3 of these parameters even given the precision of future data, leading to a more modest but still significant improvement. In addition to advances in supernova and CMB data, percent-level measurement of absolute distance and/or the expansion rate is required to ensure that dark energy constraints remain robust to variations in spatial curvature.

79 ASTRONOMY AND ASTROPHYSICS↗

Light flavor-singlet scalars and walking signals in N f = 8 QCD on the lattice

Based on the highly improved staggered quark action, we perform in this paper lattice simulations of N f = 8 QCD and confirm our previous observations, both of a flavor-singlet scalar meson (denoted as σ) as light as the pion and of various “walking signals” through the low-lying spectra, with higher statistics, smaller fermion masses m f , and larger volumes. We measure M π , F π , M ρ , M a 0 , M a 1 , M b 1 , M N , M σ , F σ , (φφ) (both directly and through the Gell-Mann-Oakes-Renner relation), and the string tension. The data are consistent with the spontaneously broken phase of the chiral symmetry, in agreement with the previous results: Ratios of the quantities to M π monotonically increase in the smaller m f region towards the chiral limit similarly to N f = 4 QCD, in sharp contrast to N f = 12 QCD where the ratios become flattened. We perform fits to chiral perturbation theory, with the value of F π found in the chiral limit extrapolation reduced dramatically to roughly 2/3 of the previous result, suggesting the theory is much closer to the conformal window. In fact, each quantity obeys the respective hyperscaling relation throughout a more extensive m f region compared with earlier works. The hyperscaling relation holds with roughly a universal value of the anomalous dimension, γ m ≃ 1, with the notable exception of M π with γ m ≃ 0.6 as in the previous results, which reflects the above growing up of the ratios towards the chiral limit. This is a salient feature (walking signal) of N f = 8, unlike either N f = 4, which has no hyperscaling relation at all, or N f = 12 QCD, which exhibits universal hyperscaling. The effective γ m Ξ γ m (m f ) of M π defined for each m f region has a tendency to grow towards unity near the chiral limit, in conformity with the Nambu-Goldstone boson nature, as opposed to the case of N f = 12 QCD where it is almost constant. We further confirm the previous observation of the light σ with mass comparable to the pion in the studied m f region. In a chiral limit extrapolation of the σ mass using the dilaton chiral perturbation theory and also using the simple linear fit, we find the value consistent with the 125 GeV Higgs boson within errors. Finally, our results suggest that the theory could be a good candidate for walking technicolor model, having anomalous dimension γ m ≃ 1 and a light flavor-singlet scalar meson as a technidilaton, which can be identified with the 125 GeV composite Higgs in the N f = 8 one-family model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Novel spirometry based on optical surface imaging

Purpose: To evaluate the feasibility of using optical surface imaging (OSI) to measure the dynamic tidal volume (TV) of the human torso during free breathing. Methods: We performed experiments to measure volume or volume change in geometric and deformable phantoms as well as human subjects using OSI. To assess the accuracy of OSI in volume determination, we performed experiments using five geometric phantoms and two deformable body phantoms and compared the values with those derived from geometric calculations and computed tomography (CT) measurements, respectively. To apply this technique to human subjects, an institutional review board protocol was established and three healthy volunteers were studied. In the human experiment, a high-speed image capture mode of OSI was applied to acquire torso images at 4–5 frames per second, which was synchronized with conventional spirometric measurements at 5 Hz. An in-house MATLAB program was developed to interactively define the volume of interest (VOI), separate the thorax and abdomen, and automatically calculate the thoracic and abdominal volumes within the VOIs. The torso volume change (TV C = ΔV{sub torso} = ΔV{sub thorax} + ΔV{sub abdomen}) was automatically calculated using full-exhalation phase as the reference. The volumetric breathing pattern (BP{sub v} = ΔV{sub thorax}/ΔV{sub torso}) quantifying thoracic and abdominal volume variations was also calculated. Under quiet breathing, TVC should equal the tidal volume measured concurrently by a spirometer with a conversion factor (1.08) accounting for internal and external differences of temperature and moisture. Another MATLAB program was implemented to control the conventional spirometer that was used as the standard. Results: The volumes measured from the OSI imaging of geometric phantoms agreed with the calculated volumes with a discrepancy of 0.0% ± 1.6% (range −1.9% to 2.5%). In measurements from the deformable torso/thorax phantoms, the volume differences measured using OSI imaging and CT imaging were 1.2% ± 2.1% (range −0.5% to 3.6%), with a linear regression fitting (slope = 1.02 and R{sup 2} = 0.999). In volunteers, the relative error in OSI tidal volume measurement was −2.2% ± 4.9% (range −9.2% to 4.8%) and a correlation of r = 0.98 was found with spirometric measurement. The breathing pattern values of the three volunteers were substantially different from each other (BP{sub v} = 0.15, 0.45, and 0.32). Conclusions: This study demonstrates the feasibility of using OSI to measure breathing tidal volumes and breathing patterns with adequate accuracy. This is the first time that dynamic breathing tidal volume as well as breathing patterns is measured using optical surface imaging. The OSI-observed movement of the entire torso could serve as a new respiratory surrogate in the treatment room during radiation therapy.

60 APPLIED LIFE SCIENCES↗

SU-C-207-07: Quantification of Coronary Artery Cross-Sectional Area in CT Angiography Using Integrated Density: A Phantom Study

Purpose: To investigate the feasibility of quantifying the cross-sectional area (CSA) of coronary arteries using integrated density in a physics-based model with a phantom study. Methods: In this technique the total integrated density of the object as compared with its local background is measured so it is possible to account for the partial volume effect. The proposed method was compared to manual segmentation using CT scans of a 10 cm diameter Lucite cylinder placed inside a chest phantom. Holes with cross-sectional areas from 1.4 to 12.3 mm{sup 2} were drilled into the Lucite and filled with iodine solution, producing a contrast-to-noise ratio of approximately 26. Lucite rods 1.6 mm in diameter were used to simulate plaques. The phantom was imaged with and without the Lucite rods placed in the holes to simulate diseased and normal arteries, respectively. Linear regression analysis was used, and the root-mean-square deviations (RMSD) and errors (RMSE) were computed to assess the precision and accuracy of the measurements. In the case of manual segmentation, two readers independently delineated the lumen in order to quantify the inter-reader variability. Results: The precision and accuracy for the normal vessels using the integrated density technique were 0.32 mm{sup 2} and 0.32 mm{sup 2}, respectively. The corresponding results for the manual segmentation were 0.51 mm{sup 2} and 0.56 mm{sup 2}. In the case of diseased vessels, the precision and accuracy of the integrated density technique were 0.46 mm{sup 2} and 0.55 mm{sup 2}, respectively. The corresponding results for the manual segmentation were 0.75 mm{sup 2} and 0.98 mm{sup 2}. The mean percent difference for the two readers was found to be 8.4%. Conclusion: The CSA based on integrated density had improved precision and accuracy as compared with manual segmentation in a Lucite phantom. The results indicate the potential for using integrated density to improve CSA measurements in CT angiography.

60 APPLIED LIFE SCIENCES↗

ML Enhancements via the Calculation of Rigid Body Modes (RBMs) for Mechanics Problems Implemented within the Albany Code Base

The algebraic multigrid approach known as smoothed aggregation is very efficient at solving systems that arise from elasticity problems. In order to construct an efficient algebraic multilevel method, a multigrid solver should be provided with a small set of vectors that represent the error components that are difficult to resolve. It is well-known that for linear elasticity problems, these components correspond to the the so-called rigid body modes (RBMs). The present document summarizes some new development within the Albany code base that has enabled the application of algebraic multigrid preconditioners from the ML package of Trilinos to mechanics problems implemented within Albany via a new function that calculates the RBMs using information about the problem's underlying mesh. The performance of these preconditioners is evaluated on four problems: a 3D static elasticity problem, a 3D non-linear elasticity problem, a 3D thermo-elasticity problem, and a 3D thermo-poro-plasticity problem. The tests reveal the superiority of the ML preconditioners over ILU preconditioners from the Trilinos Ifpack package for mechanics problems in Albany.

97 MATHEMATICS AND COMPUTING↗

Magnetic Microcalorimeter (MMC) Gamma-Ray Detectors with Ultra-High Energy Resolution. Comprehensive Technology Readiness Assessment

Magnetic Microcalorimeter (MMC) gamma ray detectors have demonstrated very high energy resolution of 38 eV FWHM for gamma ray energies below 100 keV. This is an order or magnitude better than conventional HPGe detector and can remove most line-overlap problems in NDA by gamma spectroscopy below ~130 keV. Unlike superconducting transition edge sensors (TESs), MMCs have a reproducible and almost perfectly linear response, which greatly simplifies adding spectra from different detector pixels and reduces systematic errors in quantitative assays. The instrument is currently at TRL-5 but could advance to TRL-6 by improving the signal processing software and using the system for the quantitative analysis of a safeguards sample provided by e.g. the IAEA. Making MMC detectors commercially viable and used more widely then depends on making the technology more reliable, specifically by increasing the device uniformity and yield, and by developing commercial software. This situation is often only half-jokingly referred to as the “valley of death” and could be addressed though the SBIR program. Our collaborators at STAR Cryoelectronics LLC are well qualified to further advance MMC development, and XIA LLC is well-positioned to develop the data acquisition system and write the software for MMC readout. In addition, the advance to TRL-6 would be desirable to increase the visibility and showcase the value of MMC spectrometers, e.g. by placing one of them into the Safeguards Analytical Laboratory (SAL) at the IAEA, whose NDA experts have recently started to show interest in cryogenic detector technology. As a result of this LCP, we also now have an instrument at LLNL that we will use for various applications of MMCs in nuclear safeguards and science. We are confident that as the number of high-profile results increases, so will the interest in and commercial viability of this technology.

42 ENGINEERING↗

Magnetic Microcalorimeter (MMC) Gamma-Ray Detectors with Ultra-High Energy Resolution. Comprehensive Technology Readiness Assessment

Magnetic Microcalorimeter (MMC) gamma ray detectors have demonstrated very high energy resolution of 38 eV FWHM for gamma ray energies below 100 keV. This is an order or magnitude better than conventional HPGe detector and can remove most line-overlap problems in NDA by gamma spectroscopy below ~130 keV. Unlike superconducting transition edge sensors (TESs), MMCs have a reproducible and almost perfectly linear response, which greatly simplifies adding spectra from different detector pixels and reduces systematic errors in quantitative assays. The instrument is currently at TRL-5 but could advance to TRL-6 by improving the signal processing software and using the system for the quantitative analysis of a safeguards sample provided by e.g. the IAEA. Making MMC detectors commercially viable and used more widely then depends on making the technology more reliable, specifically by increasing the device uniformity and yield, and by developing commercial software. This situation is often only half-jokingly referred to as the “valley of death” and could be addressed though the SBIR program. Our collaborators at STAR Cryoelectronics LLC are well qualified to further advance MMC development, and XIA LLC is well-positioned to develop the data acquisition system and write the software for MMC readout. In addition, the advance to TRL-6 would be desirable to increase the visibility and showcase the value of MMC spectrometers, e.g. by placing one of them into the Safeguards Analytical Laboratory (SAL) at the IAEA, whose NDA experts have recently started to show interest in cryogenic detector technology. As a result of this LCP, we also now have an instrument at LLNL that we will use for various applications of MMCs in nuclear safeguards and science. We are confident that as the number of high-profile results increases, so will the interest in and commercial viability of this technology.

42 ENGINEERING↗

Analytics of Radioactive Materials Released in the Fukushima Daiichi Nuclear Accident

The 2011 Fukushima Daiichi nuclear accident in Japan resulted in the release of radioactive materials into the atmosphere, the nearby sea, and the surrounding land. Following the accident, several meteorological models were used to predict the transport of the radioactive materials to other continents such as North America and Europe. Also of high importance is the dispersion of radioactive materials locally and within Japan. Based on the International Atomic Energy Agency (IAEA) Convention on Early Notification of a nuclear accident, several radiological data sets were collected on the accident by the Japanese authorities. Among the radioactive materials monitored, are I-131 and Cs-137 which form the major contributions to the contamination of drinking water. The radiation dose in the atmosphere was also measured. It is impractical to measure contamination and radiation dose in every place of interest. Therefore, modeling helps to predict contamination and radiation dose. Some modeling studies that have been reported in the literature include the simulation of transport and deposition of I-131 and Cs-137 from the accident, Cs-137 deposition and contamination of Japanese soils, and preliminary estimates of I-131 and Cs-137 discharged from the plant into the atmosphere. In this paper, we present statistical analytics of I-131 and Cs-137 with the goal of predicting gamma dose from the Fukushima Daiichi nuclear accident. The data sets used in our study were collected from the IAEA Fukushima Monitoring Database. As part of this study, we investigated several regression models to find the best algorithm for modeling the gamma dose. The modeling techniques used in our study include linear regression, principal component regression (PCR), partial least square (PLS) regression, and ridge regression. Our preliminary results on the first set of data showed that the linear regression model with one variable was the best with a root mean square error of 0.0133 μSv/h, compared to 0.0210 μSv/h for PCR, 0.231 μSv/h for ridge regression L-curve, 0.0856 μSv/h for PLS, and 0.0860 μSv/h for ridge regression cross validation. Complete results using the full datasets for these models will also be presented. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗