Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC RIGIDITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

SAMPEX observations of energetic hydrogen isotopes in the inner zone

We report observations of geomagnetically-trapped hydrogen isotopes at low altitudes, near the feet of field lines in the inner zone, made with the PET instrument aboard the SAMPEX satellite. We have mapped protons from 19 to 500 MeV, and have discovered a collocated belt of deuterons, which we have mapped from 18 to 58 MeV/nucleon. We found deuterium at about 1% of the level of the proton flux at the same energy per nucleon, and no tritium at energies of tens of MeV/nucleon with an upper limit of about 0.1% of the proton flux. Protons and deuterons showed similar time dependence, with fluxes approximately tripling from July 1992 to March 1996, and similar pitch-angle dependence. The high-L limits of the proton and deuteron belts as functions of energy were organized by rigidity, as was to be expected if these limits were set for both species by inability of particles to sustain adiabatic motion and stable trapping.

SAMPEX Project↗

The sweeper spectrometer for neutron invariant-mass spectroscopy at FRIB

Neutron invariant-mass spectroscopy (NIMS) is a key technique for studying unbound and weakly bound nuclei at the limits of stability. At the Facility for Rare Isotope Beams (FRIB), such measurements are performed using the Sweeper spectrometer, a large-gap, high-rigidity dipole system coupled to the MoNA-LISA neutron detector arrays. To meet the demands imposed by higher beam energies (>130 MeV/u) and the broad cocktail-beam selection available at FRIB, the spectrometer has recently been upgraded to improve particle-identification and detection performance. Upstream of the reaction target, a plastic scintillator with Silicon photomultiplier (SiPM) readout provides the global trigger and time reference, two parallel plate avalanche counters (PPACs) track the trajectories of incoming beam particles, and a silicon PIN detector measures the energy loss, ΔE, for charge (Z) identification. After the Sweeper magnet, the trajectories of the reaction products are tracked by two micro-pattern drift chambers (MPDCs), their charge (Z) is identified by a Frisch-grid ionization chamber (FG-IC), and their mass-to-charge ratio (A/Q) is deduced by time-of-flight measurement using a fast plastic scintillator read out by an array of photomultiplier tubes (PMTs). The detection system also incorporates the Modular Neutron Array (MoNA) for neutron detection and the CAESium-iodide scintillator ARray (CAESAR) for high-efficiency γ-ray measurements to enable full kinematic reconstruction. Performance was evaluated using a cocktail beam around 37 Al accelerated at E ≈ 130 MeV/u during the first FRIB campaign, demonstrating the readiness of the upgraded system for future studies of nuclei at and beyond the neutron drip line.

Particle identification methods↗

Flexible Electrostatic Technologies for Capture and Handling, Phase 1

Fundamental to many of NASA's in-space transportation missions is the capture and handling of various objects and vehicles in various orbits for servicing, debris disposal, sample retrieval, and assembly without the benefit of sufficient grapple fixtures and docking ports. To perform similar material handling tasks on Earth, pincher grippers, suction grippers, or magnetic chucks are used, but are unable to reliably grip aluminum and composite spacecraft, insulation, radiators, solar arrays, or extra-terrestrial objects in the vacuum of outer space without dedicated handles in the right places. The electronic Flexible Electrostatic Technologies for space Capture and Handling (FETCH) will enable reliable and compliant gripping (soft dock) of practically any object in various orbits or surfaces without dedicated mechanical features, very low impact capture, and built-in proximity sensing without any conventional actuators. Originally developed to handle semiconductor and glass wafers during vacuum chamber processing without contamination, the normal rigid wafer handling chucks are replaced with thin metal foil segments laminated in flexible insulation driven by commercial off-the-shelf solid state, high-voltage power supplies. Preliminary testing in NASA Marshall Space Flight Center's (MSFC's) Flat Floor Robotics Lab demonstrated compliant alignment and gripping with a full-sized, 150-lb microsat mockup and translation before a clean release with a flip of a switch. The flexible electrostatic gripper pads can be adapted to various space applications with different sizes, shapes, and foil electrode layouts even with openings through the gripper pads for addition of guidance sensors or injection of permanent adhesives. With gripping forces estimated between 0.5 and 2.5 lb/in2 or 70-300 lb/ft2 of surface contact, the FETCH can turn on and off rapidly and repeatedly to enable sample handling, soft docking, in-space assembly, precision relocation, and surface translation for accurate anchoring.

Bryan, Thomas↗

QUASI-BIENNIAL MODULATION OF GALACTIC COSMIC RAYS

The time variability of the cosmic-ray (CR) intensity at three different rigidities has been analyzed through the empirical mode decomposition technique for the period 1964-2004. Apart from the {approx}11 yr cycle, quasi-biennial oscillations (QBOs) have been detected as a prominent scale of variability in CR data, as well as in the heliomagnetic field magnitude at 1 AU and in the sunspot area. The superposition of the {approx}11 yr and QBO contributions reproduces the general features of the CR modulation, such as most of the step-like decreases and the Gnevyshev Gap phenomenon. A significant correlation has also been found between QBOs of the heliospheric magnetic field and the CR intensity during even solar activity cycles, suggesting that the former are responsible for step-like decreases in CR modulation, probably dominated by the particle diffusion/convection in such periods. In contrast, during odd-numbered cycles, no significant correlation is found. This could be explained with an enhanced drift effect also during the solar maximum or a greater influence of merged interaction regions at great heliocentric distances during odd cycles. Moreover, the QBOs of CR data are delayed with respect to sunspot activity, the lag being shorter for A > 0 periods of even cycles ({approx}1-4 months) than for A < 0 periods of odd cycles ({approx}7-9 months); we suggest that solar QBOs also affect the recovery of the CR intensity after the solar activity maximum.

79 ASTRONOMY AND ASTROPHYSICS↗

Magnetic Resonance Image Guided Radiation Therapy for External Beam Accelerated Partial-Breast Irradiation: Evaluation of Delivered Dose and Intrafractional Cavity Motion

Purpose: To use magnetic resonance image guided radiation therapy (MR-IGRT) for accelerated partial-breast irradiation (APBI) to (1) determine intrafractional motion of the breast surgical cavity; and (2) assess delivered dose versus planned dose. Methods and Materials: Thirty women with breast cancer (stages 0-I) who underwent breast-conserving surgery were enrolled in a prospective registry evaluating APBI using a 0.35-T MR-IGRT system. Clinical target volume was defined as the surgical cavity plus a 1-cm margin (excluding chest wall, pectoral muscles, and 5 mm from skin). No additional margin was added for the planning target volume (PTV). A volumetric MR image was acquired before each fraction, and patients were set up to the surgical cavity as visualized on MR imaging. To determine the delivered dose for each fraction, the electron density map and contours from the computed tomography simulation were transferred to the pretreatment MR image via rigid registration. Intrafractional motion of the surgical cavity was determined by applying a tracking algorithm to the cavity contour as visualized on cine MR. Results: Median PTV volume was reduced by 52% when using no PTV margin compared with a 1-cm PTV margin used conventionally. The mean (± standard deviation) difference between planned and delivered dose to the PTV (V95) was 0.6% ± 0.1%. The mean cavity displacement in the anterior–posterior and superior–inferior directions was 0.6 ± 0.4 mm and 0.6 ± 0.3 mm, respectively. The mean margin required for at least 90% of the cavity to be contained by the margin for 90% of the time was 0.7 mm (5th-95th percentile: 0-2.7 mm). Conclusion: Minimal intrafractional motion was observed, and the mean difference between planned and delivered dose was less than 1%. Assessment of efficacy and cosmesis of this MR-guided APBI approach is under way.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Is There an Additional Value of {sup 11}C-Choline PET-CT to T2-weighted MRI Images in the Localization of Intraprostatic Tumor Nodules?

Purpose: To investigate the additional value of {sup 11}C-choline positron emission tomography (PET)-computed tomography (CT) to T2-weighted (T2w) magnetic resonance imaging (MRI) for localization of intraprostatic tumor nodules. Methods and Materials: Forty-nine prostate cancer patients underwent T2w MRI and {sup 11}C-choline PET-CT before radical prostatectomy and extended lymphadenectomy. Tumor regions were outlined on the whole-mount histopathology sections and on the T2w MR images. Tumor localization was recorded in the basal, middle, and apical part of the prostate by means of an octant grid. To analyze {sup 11}C-choline PET-CT images, the same grid was used to calculate the standardized uptake values (SUV) per octant, after rigid registration with the T2w MR images for anatomic reference. Results: In total, 1,176 octants were analyzed. Sensitivity, specificity, and accuracy of T2w MRI were 33.5%, 94.6%, and 70.2%, respectively. For {sup 11}C-choline PET-CT, the mean SUV{sub max} of malignant octants was significantly higher than the mean SUV{sub max} of benign octants (3.69 {+-} 1.29 vs. 3.06 {+-} 0.97, p < 0.0001) which was also true for mean SUV{sub mean} values (2.39 {+-} 0.77 vs. 1.94 {+-} 0.61, p < 0.0001). A positive correlation was observed between SUV{sub mean} and absolute tumor volume (Spearman r = 0.3003, p = 0.0362). No correlation was found between SUVs and prostate-specific antigen, T-stage or Gleason score. The highest accuracy (61.1%) was obtained with a SUV{sub max} cutoff of 2.70, resulting in a sensitivity of 77.4% and a specificity of 44.9%. When both modalities were combined (PET-CT or MRI positive), sensitivity levels increased as a function of SUV{sub max} but at the cost of specificity. When only considering suspect octants on {sup 11}C-choline PET-CT (SUV{sub max} {>=} 2.70) and T2w MRI, 84.7% of these segments were in agreement with the gold standard, compared with 80.5% for T2w MRI alone. Conclusions: The additional value of {sup 11}C-choline PET-CT next to T2w MRI in detecting tumor nodules within the prostate is limited.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetic suspension system for an Annular Momentum Control Device (AMCD)

A technique to control a rim suspended in a magnetic field was developed. A complete system was developed, incorporating a support structure, magnetic actuators, a rim drive mechanism, an emergency fail-safe system, servo control system, and control electronics. Open loop and closed loop response of the system at zero speed and at 500 revolutions per minute (r/min) of the rim was obtained and analyzed. The rim was then dynamically balanced and a rim speed of 725 r/min was achieved. An analog simulation of the hardware was developed and tested with the actual control electronics connected to the analog computer. The system under development is stable at rim speeds below 700 r/min. Test results indicate that the rim under test is not rigid. The rim has a warp and a number of binding modes which prevented achievement of higher speeds. Further development efforts are required to achieve higher rim speeds.

Source record↗

Structure of the extended solar magnetic field and the sunspot cycle variation in cosmic ray intensity

It is proposed that a relation exists between the extent of interplanetary-magnetic-field sectors and observed variations in cosmic-ray intensity at earth. Changes that take place in the sector magnetic fields and solar polar fields during a sunspot cycle are described. It is argued that a geometrical effect arising from changes in sector-field and polar-field extent during sunspot cycles may be the principal cause of the 11-yr modulation of cosmic-ray intensity observed at earth. The fraction of the heliosphere occupied by sector fields is estimated as a function of time through an average sunspot cycle, the solid angle of the heliosphere occupied by the extended solar polar fields is plotted through the same cycle, and monthly averages of observed absolute intensities of primary cosmic rays with a rigidity greater than 0.5 GV are compared with the plot of polar-field extent. It is found that the average sunspot-cycle variation of the solid angle of the extended polar fields is rather similar to the observed variation in the flux of the cosmic rays considered.

Svalgaard, L.↗

Specific heat of Ce{sub x}La{sub 1-x}B{sub 6} in the low cerium concentration limit (x {<=} 0.03)

The specific heat of high-quality Ce{sub x}La{sub 1-x}B{sub 6} (x = 0, 0.01, 0.03) single crystals is studied in the temperature range 0.4-300 K. LaB{sub 6} samples with various boron isotope compositions ({sup 10}B, {sup 11}B, {sup nat}B) are analyzed to estimate the effect of boron vacancies. The experimental data are used to take into account the electron component correctly under the renormalization of the density of states at T < 8 K, the contribution of the quasi-local vibrational mode of a rare-earth ion with the Einstein temperature {Theta}{sub E} Almost-Equal-To 152 K, the Debye contribution from the rigid cage of boron atoms with the Debye temperature {Theta}{sub D} Almost-Equal-To 1160 K, and the low-temperature Schottky contribution related to the presence of 1.5-2.3% boron vacancies in the rare-earth hexaborides. The detected low-temperature anomalies in the specific heat are shown to be interpreted in terms of the formation of two-level systems with an energy {Delta}E = 92-98 K caused by the displacement of rare-earth ions from their centrosymmetric positions. A scenario of heavy fermion formation that is alternative to the Kondo mechanism is proposed for the systems with a magnetic impurity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A functional fragment of Tau forms fibers without the need for an intermolecular cysteine bridge

Highlights: • A functional fragment of Tau forms bundled ribbon-like fibrils. • Nucleation of its fibril formation is faster than for full-length Tau. • In contrast to full-length Tau, without cysteines, the fragment still forms fibers. - Abstract: We study the aggregation of a fragment of the neuronal protein Tau that contains part of the proline rich domain and of the microtubule binding repeats. When incubated at 37 °C with heparin, the fragment readily forms fibers as witnessed by Thioflavin T fluorescence. Electron microscopy and NMR spectroscopy show bundled ribbon like structures with most residues rigidly incorporated in the fibril. Without its cysteines, this fragment still forms fibers of a similar morphology, but with lesser Thioflavin T binding sites and more mobility for the C-terminal residues.

60 APPLIED LIFE SCIENCES↗

FULL ACCEPTANCE INTERACTION REGION DESIGN OF JLEIC

Nuclear physics experiments envisioned at a proposed future Electron-Ion Collider (EIC) require high luminosity of 10^33-10^34 cm^-2s^-1 and a full-acceptance detector capable of reconstruction of a whole electron-ion collision event. Due to a large asymmetry in the electron and ion momenta in an EIC, the particles associated with the initial ion tend to go at very small angles and have small rigidity offsets with respect to the initial ion beam. They are detected after they pass through the apertures of the final focusing quadrupoles. Therefore, the apertures must be sufficiently large to provide the acceptance required by experiments. In addition, to maximize the luminosity, the final focusing quadrupoles must be placed as close to the interaction point as possible. A combination of these requirements presents serious detection, optics and engineering design challenges. We present a design of a full-acceptance interaction region of Jefferson Lab Electron-Ion Collider (JLEIC). The paper presents how this design addresses the above requirements up to an ion momentum of 200 GeV/c. We summarize the magnet parameters, which are kept consistent with the Nb-Ti superconducting magnet technology.

Morozov, V.S.↗

Characterizing spatiotemporal information loss in sparse-sampling-based dynamic MRI for monitoring respiration-induced tumor motion in radiotherapy

Purpose: Sparse-sampling and reconstruction techniques represent an attractive strategy to achieve faster image acquisition speeds, while maintaining adequate spatial resolution and signal-to-noise ratio in rapid magnetic resonance imaging (MRI). The authors investigate the use of one such sequence, broad-use linear acquisition speed-up technique (k-t BLAST) in monitoring tumor motion for thoracic and abdominal radiotherapy and examine the potential trade-off between increased sparsification (to increase imaging speed) and the potential loss of “true” information due to greater reliance on a priori information. Methods: Lung tumor motion trajectories in the superior–inferior direction, previously recorded from ten lung cancer patients, were replayed using a motion phantom module driven by an MRI-compatible motion platform. Eppendorf test tubes filled with water which serve as fiducial markers were placed in the phantom. The modeled rigid and deformable motions were collected in a coronal image slice using balanced fast field echo in conjunction with k-t BLAST. Root mean square (RMS) error was used as a metric of spatial accuracy as measured trajectories were compared to input data. The loss of spatial information was characterized for progressively increasing acceleration factor from 1 to 16; the resultant sampling frequency was increased approximately from 2.5 to 19 Hz when the principal direction of the motion was set along frequency encoding direction. In addition to the phantom study, respiration-induced tumor motions were captured from two patients (kidney tumor and lung tumor) at 13 Hz over 49 s to demonstrate the impact of high speed motion monitoring over multiple breathing cycles. For each subject, the authors compared the tumor centroid trajectory as well as the deformable motion during free breathing. Results: In the rigid and deformable phantom studies, the RMS error of target tracking at the acquisition speed of 19 Hz was approximately 0.3–0.4 mm, which was smaller than the reconstructed pixel resolution of 0.67 mm. In the patient study, the dynamic 2D MRI enabled the monitoring of cycle-to-cycle respiratory variability present in the tumor position. It was seen that the range of centroid motion as well as the area covered due to target motion during each individual respiratory cycle was underestimated compared to the entire motion range observed over multiple breathing cycles. Conclusions: The authors’ initial results demonstrate that sparse-sampling- and reconstruction-based dynamic MRI can be used to achieve adequate image acquisition speeds without significant information loss for the task of radiotherapy guidance. Such monitoring can yield spatial and temporal information superior to conventional offline and online motion capture methods used in thoracic and abdominal radiotherapy.

60 APPLIED LIFE SCIENCES↗

Electron cyclotron emission reconstruction image and m/n=3/2 mode in HT-7 tokamak

Electron cyclotron emission reconstruction image has been used for flux surface reconstruction. The reconstruction image is based on plasma rigid rotation which is obtained from Mirnov diagnostic. From the reconstructed two-dimensional flux surface, the classical m/n=3/2 mode is visualized, which is of similar spatial structure as neoclassical 3/2 mode observed in some other tokamaks [B. Esposito et al., Phys. Rev. Lett. 100, 045006 (2008)].

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-point position dependence of edge intrinsic toroidal rotation on the Tokamak à Configuration Variable

Recent theoretical work predicts intrinsic toroidal rotation in the tokamak edge to depend strongly on the normalized major radial position of the X-point. With this motivation, we conducted a series of Ohmic L-mode shots on the Tokamak à Configuration Variable, moving the X-point from the inboard to the outboard edge of the last closed flux surface in both lower and upper single null configurations. The edge toroidal rotation evolved from strongly co-current for an inboard X-point to either vanishing or counter-current for an outboard X-point, in agreement with the theoretical expectations. The whole rotation profile shifted roughly rigidly with the edge rotation, resulting in variation of the peak core rotation by more than a factor of two. Core rotation reversals had little effect on the edge rotation. Edge rotation was slightly more counter-current for unfavorable than favorable ∇B drift discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Some Considerations and Techniques for the Predictive Simulation of Global Instabilities in Tokamaks

This is a write-up of a lecture given at the Fourth ITER International Summer School held at the IFS, U. Texas in June 2010. A simple rigid plasma model is used to show that axisymmetric plasma instabilities (in two-dimensions) will occur on a resistive timescale and do not depend on the plasma mass. This is the justification for ignoring the inertial term in two-dimensional studies of plasma shape control and vertical stability. In three dimensions, it is not normally possible to ignore the inertial terms when computing plasma instabilities. This results in a stiff system of equations (with multiple timescales) in which the driving terms causing plasma instabilities are small compared with the stable compressive terms. Techniques are described for implicit time integration and for representing the vector fields in a way to facilitate obtaining accurate solutions for plasma instabilities when a strong background magnetic field is present.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Position tracking of moving liver lesion based on real-time registration between 2D ultrasound and 3D preoperative images

Purpose: Registration between 2D ultrasound (US) and 3D preoperative magnetic resonance (MR) (or computed tomography, CT) images has been studied recently for US-guided intervention. However, the existing techniques have some limits, either in the registration speed or the performance. The purpose of this work is to develop a real-time and fully automatic registration system between two intermodal images of the liver, and subsequently an indirect lesion positioning/tracking algorithm based on the registration result, for image-guided interventions. Methods: The proposed position tracking system consists of three stages. In the preoperative stage, the authors acquire several 3D preoperative MR (or CT) images at different respiratory phases. Based on the transformations obtained from nonrigid registration of the acquired 3D images, they then generate a 4D preoperative image along the respiratory phase. In the intraoperative preparatory stage, they properly attach a 3D US transducer to the patient’s body and fix its pose using a holding mechanism. They then acquire a couple of respiratory-controlled 3D US images. Via the rigid registration of these US images to the 3D preoperative images in the 4D image, the pose information of the fixed-pose 3D US transducer is determined with respect to the preoperative image coordinates. As feature(s) to use for the rigid registration, they may choose either internal liver vessels or the inferior vena cava. Since the latter is especially useful in patients with a diffuse liver disease, the authors newly propose using it. In the intraoperative real-time stage, they acquire 2D US images in real-time from the fixed-pose transducer. For each US image, they select candidates for its corresponding 2D preoperative slice from the 4D preoperative MR (or CT) image, based on the predetermined pose information of the transducer. The correct corresponding image is then found among those candidates via real-time 2D registration based on a gradient-based similarity measure. Finally, if needed, they obtain the position information of the liver lesion using the 3D preoperative image to which the registered 2D preoperative slice belongs. Results: The proposed method was applied to 23 clinical datasets and quantitative evaluations were conducted. With the exception of one clinical dataset that included US images of extremely low quality, 22 datasets of various liver status were successfully applied in the evaluation. Experimental results showed that the registration error between the anatomical features of US and preoperative MR images is less than 3 mm on average. The lesion tracking error was also found to be less than 5 mm at maximum. Conclusions: A new system has been proposed for real-time registration between 2D US and successive multiple 3D preoperative MR/CT images of the liver and was applied for indirect lesion tracking for image-guided intervention. The system is fully automatic and robust even with images that had low quality due to patient status. Through visual examinations and quantitative evaluations, it was verified that the proposed system can provide high lesion tracking accuracy as well as high registration accuracy, at performance levels which were acceptable for various clinical applications.

60 APPLIED LIFE SCIENCES↗