Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAX phases”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Effects and correction of magneto-optic spatial light modulator phase errors in an optical correlator

The optical phase errors introduced into an optical correlator by the input and filter plane magnetooptic spatial light modulators have been studied. The magnitude of these phase errors is measured and characterized, their effects on the correlation results are evaluated, and a means of correction by a design modification of the binary phase-only optical-filter function is presented. The efficacy of the phase-correction technique is quantified and is found to restore the correlation characteristics to those obtained in the absence of errors, to a high degree. The phase errors of other correlator system elements are also discussed and treated in a similar fashion.

Downie, John D.↗

Iterative quantum optimization of spin glass problems with rapidly oscillating transverse fields

In this work, we introduce a new iterative quantum algorithm, called Iterative Symphonic Tunneling for Satisfiability problems (IST-SAT), which solves quantum spin glass optimization problems using high-frequency oscillating transverse fields. IST-SAT operates as a sequence of iterations, in which bitstrings returned from one iteration are used to set spin-dependent phases in oscillating transverse fields in the next iteration. Over several iterations, the novel mechanism of the algorithm steers the system toward the problem ground state. We benchmark IST-SAT on sets of hard MAX-3-XORSAT problem instances with exact state vector simulation, and report polynomial speedups over Trotterized adiabatic quantum computation and the best known semi-greedy classical algorithm. When IST-SAT is seeded with a sufficiently good initial approximation, the algorithm converges to exact solution(s) in a polynomial number of iterations. Our numerical results identify a critical Hamming radius, or quality of initial approximation, where the time-to-solution crosses from exponential to polynomial scaling in problem size. This work proposes IST-SAT a new quantum algorithm, which improves upon solutions obtained from initial classical or quantum optimization algorithms. The steering mechanism we introduce through IST-SAT presents a new path toward achieving quantum advantage in optimization.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Short hyperdynamic profiles influence primate temperature regulation

Primates have been shown to be sensitive to hyperdynamic fields. That is, when exposed to + 2Gz, body temperature falls. The purpose of this study was to examine the relative sensitivity of these animals to short centrifugation profiles which mimic the gravitational envelope seen on the Space Shuttle during launch (8 minutes, 2.9 Gz max) and re-entry (19 min, 1.7 Gz max). Four loosely restrained squirrel monkeys, isolated from additional external stimuli, were exposed to these profiles. During launch simulation, the temperatures never fell markedly below control levels. However, subsequent to return to 1G, the recovery phase showed decreases in body temperature in all four animals averaging 0.4 C over the next 10 to 15 minutes. The two animals exposed to the reentry profile showed decreases in body temperature within five minutes of the onset of centrifugation. Maximum fall in body temperature was reached by the end of the centrifugation phase and averaged 0.7 C. Thus, the temperature regulation system of this primate is sensitive to short hyperdynamic field exposures.

Fuller, C. A.↗

Observations of phase changes in monoolein during high viscous injection

Serial crystallography of membrane proteins often employs high-viscosity injectors (HVIs) to deliver micrometre-sized crystals to the X-ray beam. Typically, the carrier medium is a lipidic cubic phase (LCP) media, which can also be used to nucleate and grow the crystals. However, despite the fact that the LCP is widely used with HVIs, the potential impact of the injection process on the LCP structure has not been reported and hence is not yet well understood. The self-assembled structure of the LCP can be affected by pressure, dehydration and temperature changes, all of which occur during continuous flow injection. These changes to the LCP structure may in turn impact the results of X-ray diffraction measurements from membrane protein crystals. To investigate the influence of HVIs on the structure of the LCP we conducted a study of the phase changes in monoolein/water and monoolein/buffer mixtures during continuous flow injection, at both atmospheric pressure and under vacuum. The reservoir pressure in the HVI was tracked to determine if there is any correlation with the phase behaviour of the LCP. The results indicated that, even though the reservoir pressure underwent (at times) significant variation, this did not appear to correlate with observed phase changes in the sample stream or correspond to shifts in the LCP lattice parameter. During vacuum injection, there was a three-way coexistence of the gyroid cubic phase, diamond cubic phase and lamellar phase. During injection at atmospheric pressure, the coexistence of a cubic phase and lamellar phase in the monoolein/water mixtures was also observed. The degree to which the lamellar phase is formed was found to be strongly dependent on the co-flowing gas conditions used to stabilize the LCP stream. A combination of laboratory-based optical polarization microscopy and simulation studies was used to investigate these observations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Laminar/turbulent oscillating flow in circular pipes

A two-dimensional oscillating flow analysis was conducted simulating the gas flow inside Stirling engine heat exchangers. Both laminar and turbulent oscillating pipe flow were investigated numerically for Re(max) = 1920 (Va = 80), 10,800 (Va = 272), 19,300 (Va = 272), and 60,800 (Va = 126). The results are compared with experimental results of previous investigators. Predictions of the flow regime are also checked by comparing velocity amplitudes and phase difference with those from laminar theory and quasi-steady profile. A high Reynolds number k-epsilon turbulence model was used for turbulent oscillating pipe flow. Finally, the performance of the k-epsilon model was evaluated to explore the applicability of quasi-steady turbulent models to unsteady oscillating flow analysis.

Ahn, Kyung H.↗

XIPE the X-Ray Imaging Polarimetry Explorer

X-ray polarimetry, sometimes alone, and sometimes coupled to spectral and temporal variability measurements and to imaging, allows a wealth of physical phenomena in astrophysics to be studied. X-ray polarimetry investigates the acceleration process, for example, including those typical of magnetic reconnection in solar flares, but also emission in the strong magnetic fields of neutron stars and white dwarfs. It detects scattering in asymmetric structures such as accretion disks and columns, and in the so-called molecular torus and ionization cones. In addition, it allows fundamental physics in regimes of gravity and of magnetic field intensity not accessible to experiments on the Earth to be probed. Finally, models that describe fundamental interactions (e.g. quantum gravity and the extension of the Standard Model) can be tested. We describe in this paper the X-ray Imaging Polarimetry Explorer (XIPE), proposed in June 2012 to the first ESA call for a small mission with a launch in 2017. The proposal was, unfortunately, not selected. To be compliant with this schedule, we designed the payload mostly with existing items. The XIPE proposal takes advantage of the completed phase A of POLARIX for an ASI small mission program that was cancelled, but is different in many aspects: the detectors, the presence of a solar flare polarimeter and photometer and the use of a light platform derived by a mass production for a cluster of satellites. XIPE is composed of two out of the three existing JET-X telescopes with two Gas Pixel Detectors (GPD) filled with a He-DME mixture at their focus. Two additional GPDs filled with a 3-bar Ar-DME mixture always face the Sun to detect polarization from solar flares. The Minimum Detectable Polarization of a 1 mCrab source reaches 14 in the 210 keV band in 105 s for pointed observations, and 0.6 for an X10 class solar flare in the 1535 keV energy band. The imaging capability is 24 arcsec Half Energy Width (HEW) in a Field of View of 14.7 arcmin 14.7 arcmin. The spectral resolution is 20 at 6 keV and the time resolution is 8 s. The imaging capabilities of the JET-X optics and of the GPD have been demonstrated by a recent calibration campaign at PANTER X-ray test facility of the Max-Planck-Institut fr extraterrestrische Physik (MPE, Germany). XIPE takes advantage of a low-earth equatorial orbit with Malindi as down-link station and of a Mission Operation Center (MOC) at INPE (Brazil). The data policy is organized with a Core Program that comprises three months of Science Verification Phase and 25 of net observing time in the following 2 years. A competitive Guest Observer program covers the remaining 75 of the net observing time.

Astronomy X-ray Polarimetry↗

Fluorescence Studies of Protein Crystal Nucleation

We have postulated that, in the case of tetragonal chicken egg white lysozyme, crystal growth occurs by the addition of pre-critical nuclei sized n-mers that form in the bulk solution, and that the n-mer growth units were multiples of the tetrameric 4(sub 3) helical structure. These have the strongest intermolecular bonds in the crystal and are therefore likely to be the first species formed. High resolution AFM studies provide strong supporting evidence for this model, but the data also suggest that the actual species in solution may not be identical in structure to that found in the crystal. We are using fluorescence resonance energy transfer (FRET) to study the initial solution phase self-assembly process, using covalent fluorescent derivatives which crystallize in the characteristic P4(sub 3)2(sub 1)2(sub 1) space group. FRET studies are being carried out between the cascade blue (CB-lys, donor, Ex(sub max) 366 nm, Em 420 nm) and lucifer yellow (LY-lys, acceptor, Ex(sub max) 430 nm, Em 528 nm) asp101 derivatives. The estimated R(sub 0) for this probe pair, the distance where 50% of the donor energy is transferred to the acceptor, is approx. 1.2 nm, compared to 2.2 nm between the side chain carboxyls of adjacent asp101's in the crystalline 4(sub 3) helix. The short donor lifetime of 2.80 ns (chi(sup 2) = 0.644), coupled with the large average distances between the molecules (greater than or equal to 50 nm) in solution, ensure that any energy transfer observed is not due to random diffusive interactions. Lifetime data show that CB-lys has a single lifetime when it is the only species in solution. Similarly, LY-lys also exhibits a single lifetime of 4.63 ns (chi(sup 2) = 0.42) when alone in solution. Addition of LY-lys to CB-lys results in the appearance of a third lifetime component of 0.348ns for the CB-lys. The fractional intensities of the different species present can be used to estimate the distribution of monomer and n-mers in solution. The self-association process is a function of the protein concentration relative to the saturation concentration, and observing it in dilute solution (conc. less than or equal to 10(exp -5)M) requires that the experiments be performed under low solubility conditions, i.e., low temperatures and high salt concentrations. Data from preliminary steady state FRET studies with N-terminal bound pyrene acetic acid (PAA-lys, donor, Ex 340 nm, Em 376 nm) and asp101 LY-lys as an acceptor showed a consistent trend of decreasing donor fluorescence intensity with increasing total protein concentration. The FRET data have been obtained at pH 4.6, 0.1M NaAc buffer, at 5 and 7% NaCl, 4 C. The corresponding C(sub sat) values are 0.471 and 0.362 mg/ml (approx. 3.3 and approx. 2.5 x 10(exp -5)M respectively). The donor fluorescence decrease is more pronounced at7% NaCl, consistent with the expected increased intermolecular interactions at higher salt concentrations as reflected in the lower solubility. Results from these and other ongoing studies will be discussed in conjunction with an emerging model for how tetragonal lysozyme crystals nucleate and the relevance of that model to other proteins.

Pusey, Marc↗

Changes in the X-Ray Emission from the Magnetar Candidate 1E 2259+586 During its 2002 Outburst

An outburst of more than 80 individual bursts, similar to those seen from Soft Gamma Repeaters (SGRs), was detected from the anomalous X-ray pulsar (AXP) 1E 2259+586 in 2002 June. Coincident with this burst activity were gross changes in the pulsed flux, persistent flux, energy spectrum, pulse profile, and spin-down of the underlying X-ray source. We present Rossi X-Ray Timing Explorer and X-Ray Multi-Mirror Mission observations of 1E 2259+586 that show the evolution of the aforementioned source parameters during and following this episode and identify recovery timescales for each. Specifically, we observe an X-ray flux increase (pulsed and phase-averaged) by more than an order of magnitude having two distinct components. The first component is linked to the burst activity and decays within approx. 2 days, during which the energy spectrum is considerably harder than during the quiescent state of the source. The second component decays over the year following the glitch according to a power law in time with an exponent -0.22 +/- 0.01. The pulsed fraction decreased initially to approx. 15% rms but recovered rapidly to the preoutburst level of approx. 23% within the first 3 days. The pulse profile changed significantly during the outburst and recovered almost fully within 2 months of the outburst. A glitch of size Delta(sib (nu)max) = (4.24 +/- 0.11) x 10(exp -6) was observed in 1E 2259+586, which preceded the observed burst activity. The glitch could not be well fitted with a simple partial exponential recovery. An exponential rise of approx. 20% of the frequency jump with a timescale of approx. 14 days results in a significantly better fit to the data; however, contamination from a systematic drift in the phase of the pulse profile cannot be excluded. A fraction of the glitch (approx. 19%) was recovered in a quasi-exponential manner having a recovery timescale of approx. 16 days. The long-term postglitch spin-down rate decreased in magnitude relative to the preglitch value. The changes in the source properties of 1E 2259+586 during its 2002 outburst are shown to be qualitatively similar to changes seen during or following burst activity in two SGRs, thus further solidifying the common nature of SGRs and AXP's as magnetars. The changes in persistent emission properties of 1E 2259+586 suggest that the star underwent a plastic deformation of the crust that simultaneously impacted the superfluid interior (crustal and possibly core superfluid) and the magnetosphere. Finally, the changes in persistent emission properties coincident with burst activity in 1E 2259+586 enabled us to infer previous burst-active episodes from this and other AXP's. The nondetection of these outbursts by all-sky gamma-ray instruments suggests that the number of active magnetar candidates in our Galaxy is larger than previously thought.

Woods, P. M.↗

Bi-modal particle size distribution for high energy product hybrid Nd–Fe–B—Sm–Fe–N bonded magnets

In this work, we have demonstrated high energy product bonded magnet by leveraging the variation in sizes between Nd-Fe-B and Sm-Fe-N, as well as their hard magnetic properties. The hybrid anisotropic bonded magnets contain 70 vol% of magnet powder (Dy-free Nd-Fe-B and Sm-Fe-N) and 30 vol% of nylon. The objective of the work was to create bi-modal and bi-compositional bonded magnets in which the fine (3μm) particles of Sm-Fe-N would be used to fill the voids between the bigger Nd-Fe-B (105μm) particles, thus improve packing density. The magnetic hysteresis loop did not show significant signs of decoupled interactions between the magnetic phases. It was also found that the performance of the bonded magnet was most enhanced at 1:4 ratio of Nd-Fe-B and Sm-Fe-N. At that ratio, maximum density of 5 g/cm 3 and the highest (BH) max value of 18.5 MGOe were obtained, although the intrinsic coercivity decreased, relative to the trend seen for other ratios. This work advances the opportunity to expand the use of Sm-Fe-N in bonded magnet applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scaling relations in the phase-space structure of dark matter haloes

We present new scaling relations for the isotropic phase-space distribution functions (DFs) and energy distributions of simulated dark matter haloes. These relations are inspired by those for the singular isothermal sphere with density profile $\rho (r)\propto r^{-2}$, for which the DF satisfies $f(E) \propto r_{\mathrm{max}}^{-2}(E)$ and the energy distribution satisfies $\mathrm{ d}M/\mathrm{ d}E \propto r_{\mathrm{max}}(E)$, with $r_{\mathrm{max}}(E)$ being the radius where the gravitational potential equals energy $E$. For the simulated haloes, we find $f(E)\propto r_{\mathrm{max}}^{-2.08}(E)$ and $\mathrm{ d}M/\mathrm{ d}E \propto r_{\mathrm{max}}(E)$ across broad energy ranges. In addition, the proportionality coefficients depend on the gravitational constant and the parameters of the best-fitting Navarro–Frenk–White density profile. These scaling relations are satisfied by haloes over a wide mass range and provide an efficient method to approximate their DFs and energy distributions. Understanding the origin of these relations may shed more light on halo formation.

galaxies: haloes↗

Alignment and phasing of deployable telescopes

The experiences in coaligning and phasing the Multi-Mirror Telescope (MMT), together with studies in setting up radio telescopes, are presented. These experiences are discussed, and on the basis they furnish, schemes are suggested for coaligning and phasing four large future telescopes with complex primary mirror systems. These telescopes are MT2, a 15-m-equivalent MMT, the University of California Ten Meter Telescope, the 10 m sub-mm wave telescope of the University of Arizona and the Max Planck Institute for Radioastronomy, and the Large Deployable Reflector, a future space telescope for far-IR and sub-mm waves.

Woolf, N. J.↗

A 2-D oscillating flow analysis in Stirling engine heat exchangers

A two dimensional oscillating flow analysis was conducted, simulating the gas flow inside Stirling heat exchangers. Both laminar and turbulent oscillating pipe flow were investigated numerically for Re(max) = 1920 (Va = 80), 10800 (Va = 272), 19300 (Va = 272), and 60800 (Va = 126). The results are compared with experimental results of previous investigators. Also, predictions of the flow regime on present oscillating flow conditions were checked by comparing velocity amplitudes and phase differences with those from laminar theory and quasi-steady profile. A high Reynolds number k-epsilon turbulence model was used for turbulent oscillating pipe flow. Finally, performance evaluation of the K-epsilon model was made to explore the applicability of quasi-steady turbulent models to unsteady oscillating flow analysis.

Ahn, Kyung H.↗

A 2-D oscillating flow analysis in Stirling engine heat exchangers

A two-dimensional oscillating flow analysis was conducted, simulating the gas flow inside Stirling heat exchangers. Both laminar and turbulent oscillating pipe flow were investigated numerically for Re(max) = 1920 (Va = 80), 10800 (Va = 272), 19300 (Va = 272), and 60800 (Va = 126). The results are compared with experimental results of previous investigators. Also, predictions of the flow regime on present oscillating flow conditions were checked by comparing velocity amplitudes and phase differences with those from laminar theory and quasi-steady profile. A high Reynolds number k-epsilon turbulence model was used for turbulent oscillating pipe flow. Finally, performance evaluation of the K-epsilon model was made to explore the applicability of quasi-steady turbulent models to unsteady oscillating flow analysis.

Ahn, Kyung H.↗

On-board Limb-based Shape Modeling for Small Body Navigation

Missions to small bodies within our solar system are becoming more frequent. Generally, shape models of the target body are required to perform proximity operations as demonstrated by the OSIRIS-REx, Hayabusa2, and Rosetta missions. However, these missions required image downlinking to create high-resolution models on the ground. In some missions, especially small-sats, there may be data downlink data constraints, resulting in the inability to provide the large number of images needed for high-resolution shape models. A solution to this is the ability to generate shape models on-board during the approach to the target or initial proximity surveying. Current work implements a limb-based shape model routine that is able to be executed on a Raspberry Pi 1, which is similar to the processing capability to the flight computer on OSIRIS-REx, and that does not require low phase angle geometries. Initial shape model results generated from Bennu approach (Nov 2-3, 2018) show that the limb-based shape model agrees well with a 75-cm SPC shape model generated after Preliminary Survey; Results are: min difference -7.047m, max difference 17.347m, mean 1.122m, and RMS 3.219m. Further scenarios are presented herein.

Limb-based↗

Microstructure refinement of hot deformed Dy-free NdFeB magnets through a novel cold sintering approach by pressure-assisted spark plasma sintering

Anisotropic fine-grained Dy-free NdFeB high-performance magnets were produced using a novel cold sintering approach by pressure-assisted spark plasma sintering (SPS). The NdFeB nanocrystalline ribbon powders were subjected to cold sintering below 450 °C using pressure-assisted SPS, followed by hot deformation at 710 °C and 810 °C via SPS. Results indicate that cold sintering below 450 °C effectively restricts grain growth in the NdFeB magnets, yielding sub-100 nm scale grains across both fine-grained regions and most coarse-grained regions. The refined grain structure achieved through cold sintering allows for a lower hot deformation temperature as compared with the magnet by conventional sintering, as finer grains allow easier deformation and grain sliding/rotation. This process produces a highly fine-grained and anisotropic microstructure to achieve high magnetic performance (i.e., high intrinsic coercivity, remanence, and maximum energy product) in the magnets. The cold sintering (at 350 °C) and lower hot deformation temperatures required (e.g., 710 °C) help control grain coarsening and limit grain size that is commensurate with the size of a single magnetic domain of the Nd 2 Fe 14 B magnetic matrix phase, resulting in high intrinsic coercivity (H ci =11.4 kOe). Furthermore, the reduced hot deformation temperature mitigates the formation of coarse grain bands, leading to improved magnetic properties, specifically an increased remanence (B r = 14.3 kGs) and a high maximum energy product ((BH) max = 48 MGOe). In conclusion, cold sintered hot deformed NdFeB magnet also shows good thermal stability with reversible temperature coefficient α(B r )= -0.097 %/K and α(H ci )= -0.616 %/K at elevated temperatures up to 400 K.

Cold Sintering↗

Nonequilibrium Crystal Growth During Laser Annealing of Silicon

The Systematic studies of dopant (Group III, IV, or V) incorporation into silicon as a result of pulsed-laser annealing are reviewed. At low concentrations, dopant profiles measured after laser annealing can be compared to model calculations for redistribution by liquid-phase diffusion in order to determine the interfacial distribution coefficient K('). At high concentrations there is a limit (C sub s) to dopant incorporation into substitutional lattice sites. The mechanisms which limit dopant incorporation are discussed as well as the dependence of K(') and (max) on crystal orientation. Finally, measurements of interface temperatures, temperature profiles, and thermal gradients during rapid solidification are summarized.

White, C. W.↗

Compressor Has No Moving Macroscopic Parts

Compressor containing no moving macroscopic parts functions by alternating piston and valve actions of successive beds of magnetic particles. Fabricated easily because no need for precisely fitting parts rotating or sliding on each other. Also no need for lubricant fluid contaminating fluid to be compressed. Compressor operates continuously, eliminating troublesome on/off cycling of other compressors, and decreasing consumption of energy. Phased cells push fluid from bottom to top, adding increments of pressure. Each cell contains magnetic powder particles loose when electromagnet coil deenergized, but tightly packed when coil energized.

Gasser, Max↗