Search NASA⌕ Search

SEARCH · Search NASA

Results for “Material point method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Method for Selective Thermal Ablation

A method, simulation, and apparatus are provided that are highly suitable for treatment of benign prostatic hyperplasia (BPH). A catheter is disclosed that includes a small diameter disk loaded monopole antenna surrounded by fusion material having a high heat of fusion and a melting point preferably at or near body temperature. Microwaves from the antenna heat prostatic tissue to promote necrosing of the prostatic tissue that relieves the pressure of the prostatic tissue against the urethra as the body reabsorbs the necrosed or dead tissue. The fusion material keeps the urethra cool by means of the heat of fusion of the fusion material. This prevents damage to the urethra while the prostatic tissue is necrosed. A computer simulation is provided that can be used to predict the resulting temperature profile produced in the prostatic tissue. By changing the various control features of the catheter and method of applying microwave energy a temperature profile can be predicted and produced that is similar to the temperature profile desired for the particular patient.

Arndt, G. Dickey↗

Method of Constructing a Microwave Antenna

A method, simulation, and apparatus are provided that are highly suitable for treatment of benign prostatic hyperplasia (BPH). A catheter is disclosed that includes a small diameter disk loaded monopole antenna surrounded by fusion material having a high heat of fusion and a melting point preferably at or near body temperature. Microwaves from the antenna heat prostatic tissue to promote necrosing of the prostatic tissue that relieves the pressure of the prostatic tissue against the urethra as the body reabsorbs the necrosed or dead tissue. The fusion material keeps the urethra cool by means of the heat of fusion of the fusion material. This prevents damage to the urethra while the prostatic tissue is necrosed. A computer simulation is provided that can be used to predict the resulting temperature profile produced in the prostatic tissue. By changing the various control features of the catheter and method of applying microwave energy a temperature profile can be predicted and produced that is similar to the temperature profile desired for the particular patient.

Arndt, G. Dickey↗

Method for selective thermal ablation

A method, simulation, and apparatus are provided that are highly suitable for treatment of benign prostatic hyperplasia (BPH). A catheter is disclosed that includes a small diameter disk loaded monopole antenna surrounded by fusion material having a high heat of fusion and a melting point preferably at or near body temperature. Microwaves from the antenna heat prostatic tissue to promote necrosing of the prostatic tissue that relieves the pressure of the prostatic tissue against the urethra as the body reabsorbs the necrosed or dead tissue. The fusion material keeps the urethra cool by means of the heat of fusion of the fusion material. This prevents damage to the urethra while the prostatic tissue is necrosed. A computer simulation is provided that can be used to predict the resulting temperature profile produced in the prostatic tissue. By changing the various control features of the catheter and method of applying microwave energy a temperature profile can be predicted and produced that is similar to the temperature profile desired for the particular patient.

Arndt, G. Dickey↗

Method of constructing a microwave antenna

A method, simulation, and apparatus are provided that are highly suitable for treatment of benign prostatic hyperplasia (BPH). A catheter is disclosed that includes a small diameter disk loaded monopole antenna surrounded by fusion material having a high heat of fusion and a melting point preferably at or near body temperature. Microwaves from the antenna heat prostatic tissue to promote necrosing of the prostatic tissue that relieves the pressure of the prostatic tissue against the urethra as the body reabsorbs the necrosed or dead tissue. The fusion material keeps the urethra cool by means of the heat of fusion of the fusion material. This prevents damage to the urethra while the prostatic tissue is necrosed. A computer simulation is provided that can be used to predict the resulting temperature profile produced in the prostatic tissue. By changing the various control features of the catheter and method of applying microwave energy a temperature profile can be predicted and produced that is similar to the temperature profile desired for the particular patient.

Arndt, G. Dickey↗

Neutralization of cement-asbestos waste by melting in an arc-resistance furnace

Highlights: • Interesting possibility for cement-asbestos wastes utilisation. • Product of thermal treatment of cement-asbestos may be considered as useful secondary raw material. • Complete destruction of asbestos fibrous structure by melting process in arc-resistance furnace. • Reduction of cement-asbestos waste melting point by flux addition. - Abstract: The paper presents the results of research on asbestos waste disposal by the melting process. The tests were carried out in a laboratory arc-resistance electric furnace. The obtained results showed that the fibrous structure of asbestos contained in cement-asbestos waste was completely destroyed. This led to the formation of new mineral phases without dangerous properties. The melting test was conducted on raw cement-asbestos samples without any additives and with a content of mineral compounds, the aim of which was to support the melting process. The additives were selected among others on the basis of the computer simulation results carried out using FactSage database computing system. The research results indicate that the melting process of asbestos wastes is a potential and interesting method of neutralizing hazardous asbestos waste, which allows for further treatment and material recycling.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Recent advances in materials toxicology

An overview of the fire toxicology program, its principal objectives and approach, is outlined. The laboratory methods of assessing pyrolysis product toxicity for two experiments are presented. The two experiments are: a comparison of test end points; and an evaluation of operant techniques. A third experiment is outlined for a comparison of full-scale and laboratory toxicity tests, with the purpose of determining animal survivability in full-scale tests. Future research plans are also outlined.

Russo, D. M.↗

Multi–length scale characterization of point defects in thermally oxidized, proton irradiated iron oxides

A key for the success of safe nuclear power generation system is to consider structural materials that are economical, meet mechanical property needs, possess good corrosion resistance, and are radiation tolerant. Nevertheless, fundamental insights that elucidate the details of radiation damage on materials corrosion performance are lacking. This includes the behavior of surface oxides which often regulate corrosion. For example, it is unclear how non-equilibrium point defects, oxide structure, mass transport in oxides, and subsequent oxidation behavior are altered by the radiation. Here, in this work, some of the effects of proton irradiation on the attributes of point defects, iron oxide microstructures, and the physical nature of the oxidation product were correlated with corrosion behavior. Iron oxides, fabricated by thermal oxidation in air at 400°C and 800°C for 1 h, were subjected to 200 keV, 0.03 dpa (displacements per atom) of proton irradiation, and subjected to corrosion reactivity assessment using AC and DC electrochemical methods. Experimental methods that target materials information at different length scales, such as positron annihilation spectroscopy (atomistic), transmission electron microscopy (mesoscopic), and electrochemical methods (macroscopic), were coupled to shed light on the impact of radiation-induced defect modifications and structural changes in oxides on corrosion reactivity which ultimately affects durability in harsh environments.

36 MATERIALS SCIENCE↗

The role of electron correlations in the electronic structure of putative Chern magnet TbMn6Sn6

Abstract A member of the RMn 6 Sn 6 rare-earth family materials, TbMn 6 Sn 6 , recently showed experimental signatures of the realization of a quantum-limit Chern magnet. In this work, we use quantum Monte Carlo (QMC) and density functional theory with Hubbard U (DFT + U ) calculations to examine the electronic structure of TbMn 6 Sn 6 . To do so, we optimize accurate, correlation-consistent pseudopotentials for Tb and Sn using coupled-cluster and configuration–interaction (CI) methods. We find that DFT + U and single-reference QMC calculations suffer from the same overestimation of the magnetic moments as meta-GGA and hybrid density functional approximations. Our findings point to the need for improved orbitals/wavefunctions for this class of materials, such as natural orbitals from CI, or for the inclusion of multi-reference effects that capture the static correlations for an accurate prediction of magnetic properties. DFT + U with Mn magnetic moments adjusted to the experiment predict the Dirac crossing in bulk to be close to the Fermi level, within ~120 meV, in agreement with the experiments. Our non-stoichiometric slab calculations show that the Dirac crossing approaches even closer to the Fermi level, suggesting the possible realization of Chern magnetism in this limit.

36 MATERIALS SCIENCE↗

Surface Tension and Viscosity of SCN and SCN-acetone Alloys at Melting Points and Higher Temperatures Using Surface Light Scattering Spectrometer

Succinonitrile has been and is being used extensively in NASA's Microgravity Materials Science and Fluid Physics programs and as well as in several ground-based and microgravity studies including the Isothermal Dendritic Growth Experiment (IDGE). Succinonitrile (SCN) is useful as a model for the study of metal solidification, although it is an organic material, it has a BCC crystal structure and solidifies dendriticly like a metal. It is also transparent and has a low melting point (58.08 C). Previous measurements of succinonitrile (SCN) and alloys of succinonitrile and acetone surface tensions are extremely limited. Using the Surface Light Scattering technique we have determined non invasively, the surface tension and viscosity of SCN and SCN-Acetone Alloys at different temperatures. This relatively new and unique technique has several advantages over the classical methods such as, it is non invasive, has good accuracy and measures the surface tension and viscosity simultaneously. The accuracy of interfacial energy values obtained from this technique is better than 2% and viscosity about 10 %. Succinonitrile and succinonitrile-acetone alloys are well-established model materials with several essential physical properties accurately known - except the liquid/vapor surface tension at different elevated temperatures. We will be presenting the experimentally determined liquid/vapor surface energy and liquid viscosity of succinonitrile and succinonitrile-acetone alloys in the temperature range from their melting point to around 100 C using this non-invasive technique. We will also discuss about the measurement technique and new developments of the Surface Light Scattering Spectrometer.

Tin, Padetha↗

The oxygen stable isotope composition of CRM 125-A UO 2 standard reference material

While there is a clear need for standardized reference materials for analytical calibrations and for inter-laboratory comparisons, there are not currently any for the oxygen stable isotopic composition of uranium oxides. In this paper we summarize the results from four laboratories by seven different methods of oxygen stable isotope analyses using fluorination techniques of CRM 125-A UO 2 Standard Reference Material. We synthesize these data and methods to arrive at a consensus oxygen stable isotope composition for CRM 125-A $δ$ 18 O = -9.63‰ (±0.29‰) VSMOW. We discuss methodological differences between analytical approaches, including furnace vs laser heating, fluorination using BrF 5 or ClF 3 , as well as calibration strategies. We highlight the potential effects of calibration scale compression from single-point calibrations using reference material with $δ$ 18 O values having a large relative difference from the sample being analyzed. We demonstrate how calibration scale compression can yield differences in calibrated $δ$ 18 O values up to ~2‰ for samples with ~20‰ difference from a single reference material, if the calibration slope of different analytical systems differs by 0.1. In conclusion, we suggest the use of liquid water calibration standards sealed in silver capillary tubes for multi-point calibrations of fluorination analysis systems.

07 ISOTOPE AND RADIATION SOURCES↗

Day-to-Day Reproducibility of Prostate Intrafraction Motion Assessed by Multiple kV and MV Imaging of Implanted Markers During Treatment

Purpose: When one is performing online setup correction for prostate positioning displacements prior to daily dose delivery, intrafraction motion can become a limiting factor to prostate targeting accuracy. The aim of this study was to quantify and characterize prostate intrafraction motion assessed by multiple kilovoltage (kV) and megavoltage (MV) imaging of implanted markers during treatment in a large patient group. Methods and Materials: Intrafraction motion in the sagittal plane was studied by retrospective analysis of displacements of implanted gold markers on (nearly) lateral kV and MV images obtained at various time points during the treatment fractions (mean, 27 per patient) in 108 consecutive patients. The effective prostate motion in a fraction was defined as the time-weighted mean displacement. Results: Prostate displacements in the sagittal plane increased during the fraction (mean, 0.2 {+-} 0.2 mm/min). Forty percent of patients had a systematic (i.e., appearing in all fractions) effective displacement in the sagittal plane greater than 2 mm. Observed effective population mean-of-means ({mu}eff) +/- systematic ({Sigma}eff) intrafraction motion ({mu}{sub eff} {+-} {Sigma}{sub eff}) was 0.9 {+-} 1.1 mm and 0.6 {+-} 1.0 mm for the anterior-posterior and superior inferior directions, respectively. Corresponding random motion ({sigma}{sub eff}) was 1.2 mm and 1.1 mm. Mean effective prostate motion in the first 5 fractions was predictive for mean effective displacement in the remaining fractions (p < 0.001). Conclusion: For a large subgroup of patients, the systematic component of intrafraction prostate motion was substantial. Intrafraction motion correction prior to each beam delivery or offline corrections could likely be beneficial for the subgroup of patients with significant motion. The systematic component is well predicted by measurements in the initial fractions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Evaluation of Departmental Radiation Oncology Incident Reports: Anticipating a National Reporting System

Purpose: Systems to ensure patient safety are of critical importance. The electronic incident reporting systems (IRS) of 2 large academic radiation oncology departments were evaluated for events that may be suitable for submission to a national reporting system (NRS). Methods and Materials: All events recorded in the combined IRS were evaluated from 2007 through 2010. Incidents were graded for potential severity using the validated French Nuclear Safety Authority (ASN) 5-point scale. These incidents were categorized into 7 groups: (1) human error, (2) software error, (3) hardware error, (4) error in communication between 2 humans, (5) error at the human-software interface, (6) error at the software-hardware interface, and (7) error at the human-hardware interface. Results: Between the 2 systems, 4407 incidents were reported. Of these events, 1507 (34%) were considered to have the potential for clinical consequences. Of these 1507 events, 149 (10%) were rated as having a potential severity of ≥2. Of these 149 events, the committee determined that 79 (53%) of these events would be submittable to a NRS of which the majority was related to human error or to the human-software interface. Conclusions: A significant number of incidents were identified in this analysis. The majority of events in this study were related to human error and to the human-software interface, further supporting the need for a NRS to facilitate field-wide learning and system improvement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determinants of Patient Satisfaction During Receipt of Radiation Therapy

Purpose: To evaluate the correlations and relative contributions of components of a radiation oncology-specific patient satisfaction survey to their overall satisfaction scores. Methods and Materials: From September 2006 through August 2012, we prospectively collected data from 8069 patients receiving radiation treatments with a 26-question survey. Each question was rated on a 10-point Likert scale. We analyzed the correlation between scores for each question and the overall satisfaction question. We also dichotomized the scores to reflect satisfaction versus dissatisfaction and used logistic regression to assess the relationship between items in 4 domains (the patient–provider relationship, access and environmental issues, wait times, and educational information) and overall satisfaction. Results: Scores on all questions correlated with overall patient satisfaction scores (P<.0001). Satisfaction with patient–provider relationships had the greatest influence on overall satisfaction (R{sup 2}=0.4219), followed by wait times (R{sup 2}=0.4000), access/environment (R{sup 2}=0.3837), and patient education (R{sup 2}=0.3700). The specific variables with the greatest effect on patient satisfaction were the care provided by radiation therapists (odds ratio 1.91) and pain management (odds ratio 1.29). Conclusions: We found that patients' judgment of provider relationships in an outpatient radiation oncology setting were the greatest contributors to their overall satisfaction ratings. Other measures typically associated with patient satisfaction (phone access, scheduling, and ease of the check-in process) correlated less strongly with overall satisfaction. These findings may be useful for other practices preparing to assess patient ratings of quality of care.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nickel-cobalt alloy nanosheets obtained from reductive hydrothermal-treatment of nickel-cobalt hydroxide carbonate

Highlights: Black-Right-Pointing-Pointer An anionic layered material, nickel-cobalt hydroxide carbonate was synthesized. Black-Right-Pointing-Pointer Reductive hydrothermal-treatment of the layered precursor produced an alloy. Black-Right-Pointing-Pointer The alloy is a bimetallic nanostructured nickel-cobalt and a soft magnet material. -- Abstract: Nickel-cobalt hydroxide carbonate, a layered material was synthesized by the co-precipitation method using urea as precipitant agent. This anionic layered material with hexagonal structure is constructed from nickel and cobalt ions within the layers and carbonate anions between the layers. Nickel-cobalt alloy with pure cubic phase was obtained by a reductive hydrothermal-treatment of the layered precursor. Powder X-ray diffraction pattern and Fourier transform infrared spectroscopy confirmed the formation of the initial layered material and its metallic alloy product. That is, the nickel-cobalt alloy has really produced via a wet chemical route for the first time. Magnetic measurement revealed that the alloy sample is a soft magnet material.

36 MATERIALS SCIENCE↗

Disorder effects on the band structure of ZnGeN 2 : Role of exchange defects

The role of exchange defects on the band structure of ZnGeN 2 is investigated. Exchange defects are defined through the exchange of cations Zn and Ge starting from the ideal Pna2 1 crystal structure, which obeys the local octet rule. Each such exchange creates several nitrogen-centered tetrahedra which violate the local octet rule, although overall charge neutrality is preserved. We study several distributions of exchange defects, some with all antisites making up the exchange defect close to each other and with increasing numbers of exchange defects, and others where the two types of antisites Zn Ge and Ge Zn are kept separated from each other. We also compare the results for these models with a fully random distribution of Zn and Ge on the cation sites. We show that for a single-nearest-neighbor exchange defect, the band gap is narrowed by about 0.5 eV due to two effects: (1) the Zn Ge antisites form filled acceptor states just above and merging with the valence-band maximum (VBM) of perfect crystal ZnGeN 2 and (2) the Ge Zn antisites form a resonance in the conduction band which lowers the conduction-band minimum (CBM). When more exchange defects are created, these acceptor states broaden into bands which can lower the gap further. When tetrahedra occur surrounded completely by four Zn atoms, states even deeper in the gap are found localized all near these tetrahedra, forming a separate intermediate band. Finally, for phase-segregated Zn Ge and Ge Zn , the gap is significantly more reduced, but no separate band is found to occur. The Zn Ge acceptorlike states now form a percolating defect band which is significantly wider and hence reaches deeper into the gap. In all cases, the wave functions near the top of the new VBM remain, to some extent, localized near the Zn Ge sites. For a fully random case, the gap is even more severely reduced by almost 3 eV. The total energy of the system increases with the number of octet-rule-violating tetrahedra and the energy cost per exchange defect of order 2 eV is quite high.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nuclear-physical analysis methods in medical geology: Assessment of the impact of environmental factors on human health

The procedure for geomedical studies is outlined, and the niche occupied by the nuclear-physical analysis methods in these studies is pointed out. The necessity of construction of an efficient complex of the most modern analytical methods is demonstrated. The metrological parameters of methods applied in the analysis of natural environments and biological materials are evaluated. The current state of pollution of natural environments with heavy and toxic metals is characterized in two specific industrial hubs: the towns of Gus-Khrustalny and Podolsk. The levels of pollution of diagnostic biological materials (hair and blood) from children living in various urban districts are studied in the light of specific features of the manufacturing industry in these towns and the life environment of child population. The results of studies focused on evaluating the effect of environment on the health of child population are detailed. The actual damage to child health, their neuropsychic development and behavior, and the effect of socioeconomic factors are determined. Preventive problems among the child population exposed to lead and other toxic metals are evaluated, and ways to solve them are proposed. A system of early diagnosis and preventive measures for the mitigation of adverse effect of toxic metals (Pb, Cu, Mn, Zn, Cr, Ni, As, etc.) on the neuropsychic development of children is developed based on an actual ecogeochemical estimation of the state of the region under study.

54 ENVIRONMENTAL SCIENCES↗

Photoelastic techniques for the complete determination of stresses in composite structures

Three methods of photoelastic analysis are examined. The first method is an extension of the oblique incidence technique in which the model (or the light beam) is rotated about one of the material symmetry axes. In the second method, transmission and reflection photoelastic responses are combined. The third method requires the drilling of small holes and the determination of the fringe orders at selected points on the hole boundary. The three methods are applied to an orthotropic circular disk under diametral compression. Results are compared with strain gage data.

Prabhakaran, R.↗

Least Squares Best Fit Method for the Three Parameter Weibull Distribution: Analysis of Tensile and Bend Specimens with Volume or Surface Flaw Failure

Material characterization parameters obtained from naturally flawed specimens are necessary for reliability evaluation of non-deterministic advanced ceramic structural components. The least squares best fit method is applied to the three parameter uniaxial Weibull model to obtain the material parameters from experimental tests on volume or surface flawed specimens subjected to pure tension, pure bending, four point or three point loading. Several illustrative example problems are provided.

Gross, Bernard↗