Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

The Marshall Space Flight Center Solar Utraviolet Magnetograph

This paper will describe the objectives of the Marshall Space Flight Center (MSFC) Solar Ultraviolet Magnetograph Investigation (SUMI) and the optical components that have been developed to meet those objectives. In order to test the scientific feasibility of measuring magnetic fields in the W, a sounding rocket payload is being developed. This paper will discuss: (1) the scientific measurements that will be made by the SUMI sounding rocket program, (2) how the optics have been optimized for simultaneous measurements of two magnetic lines CIV (1550 Angstroms) and MgII (2800 Angstroms), and (3) the optical, reflectance, transmission and polarization measurements that have been made on the SUMI telescope mirrors and polarimeter.

West, E. A.↗

The Marshall Space Flight Center Solar Ultraviolet Magnetograph

This paper will describe the objectives of the Marshall Space Flight Center (MSFC) Solar Ultraviolet Magnetograph Investigation (SUMI) and the optical components that have been developed to meet those objectives. In order to test the scientific feasibility of measuring magnetic fields in the UV, a sounding rocket payload is being developed. This paper will discuss: (1) the scientific measurements that will be made by the SUMI sounding rocket program, (2) how the optics have been optimized for simultaneous measurements of two magnetic lines CIV (1550Angstroms) and MgII (2800Angstroms), and (3) the optical, reflectance, transmission and polarization measurements that have been made on the SUMI telescope mirrors and polarimeter.

West, E. A.↗

Reflectance-Based Imaging Spectrometer Error Budget Field Practicum at the Railroad Valley Test Site, Nevada

Calibration and validation determine the quality and integrity of the data provided by sensors and have enormous downstream impacts on the accuracy and reliabilityof the products generated by these sensors. With the imminent launch of the next generation of space borne imaging spectroscopy sensors, the IEEE Geoscience and Remote Sensing Society's (GRSS's) Geoscience Spaceborne Imaging Spectroscopy Technical Committee (GSIS TC) initiated a calibration and validation initiative.This article reports on a recent reflectance-based imaging spectrometer error budget field practicum focused on radiometric calibration of spaceborne imaging spectroscopy sensors. The field exercise, conducted at Railroad Valley in Nevada, provided valuable training for personnel in a variety of Earth observation (EO) areas, from engineers developing future sensors to calibration scientists actively working in the field. Future work in this area will focus on analyzing the data acquired as part of the training to answer numerous scientific questions, e.g., understanding the spatial and spectral homogeneity of the site being measured, identifying the optimal sampling to characterize the site, and optimizating the sampling techniques, including looking into the automation of some measurement protocol aspects. The training exercise was recorded to ensure that the knowledge can be disseminated across the GRSS and wider imaging spectroscopy community.

Ong, Cindy↗

Sizing and Topology Design of an Aeroelastic Wingbox Under Uncertainty

The goals of this work are to use a nested optimizer to conduct simultaneous sizing (inner level) and topology (outer level) design of a wingbox, considering uncertainties in the safety factors used to define the aeroelastic constraints. These uncertainties, propagated via sampling-driven polynomial chaos, are explicitly introduced at the inner level of the method, during gradient-based sizing optimization, resulting in a stochastic optimal sizing distribution. Measures of robustness in the total structural mass are then passed to the outer level, where a global optimizer evolves the topology parameters. The results demonstrate design choices needed to improve robustness in the face of uncertain safety factors, and the various physical mechanisms driving this process.

Stanford, Bret K.↗

Reducing Errors by Use of Redundancy in Gravity Measurements

A methodology for improving gravity-gradient measurement data exploits the constraints imposed upon the components of the gravity-gradient tensor by the conditions of integrability needed for reconstruction of the gravitational potential. These constraints are derived from the basic equation for the gravitational potential and from mathematical identities that apply to the gravitational potential and its partial derivatives with respect to spatial coordinates. Consider the gravitational potential in a Cartesian coordinate system {x1,x2,x3}. If one measures all the components of the gravity-gradient tensor at all points of interest within a region of space in which one seeks to characterize the gravitational field, one obtains redundant information. One could utilize the constraints to select a minimum (that is, nonredundant) set of measurements from which the gravitational potential could be reconstructed. Alternatively, one could exploit the redundancy to reduce errors from noisy measurements. A convenient example is that of the selection of a minimum set of measurements to characterize the gravitational field at n3 points (where n is an integer) in a cube. Without the benefit of such a selection, it would be necessary to make 9n3 measurements because the gravitygradient tensor has 9 components at each point. The problem of utilizing the redundancy to reduce errors in noisy measurements is an optimization problem: Given a set of noisy values of the components of the gravity-gradient tensor at the measurement points, one seeks a set of corrected values - a set that is optimum in that it minimizes some measure of error (e.g., the sum of squares of the differences between the corrected and noisy measurement values) while taking account of the fact that the constraints must apply to the exact values. The problem as thus posed leads to a vector equation that can be solved to obtain the corrected values.

Kulikov, Igor↗

Optimization of the thrombin generation test components to measure potency of factor VIII concentrates

Introduction The thrombin generation test (TGT) is used both as a global haemostasis assay, and to compare activities of coagulation factor concentrates that have been spiked into patient plasma. However, TGT has not been systematically optimized to evaluate factor VIII (FVIII) product potency. Aims To improve the sensitivity of TGT to FVIII and allow a comparative analysis of the thrombin generating capacities of FVIII concentrates against reference preparations with known FVIII activity. Methods Concentrations of TGT components (analytical variables) were assessed to maximize the linearity and range of responses to the concentration of FVIII. Results We optimized the range and sensitivity of the TGT assay with respect to FVIII through the addition of FXIa to the assay. Other parameters that were adjusted, i.e. tissue factor (TF), procoagulant lipids and plasma concentrations, did not improve the ability of the assay to measure both high and very low levels of FVIII. In the optimized TF/FXIa‐activated TGT assay, all thrombin generation curve parameters were suitable for FVIII quantification, but thrombin peak height and maximal velocity demonstrated better linearity in the desired FVIII range. We found that the optimized TF/FXIa‐activated TGT has a wider range of sensitivity to FVIII than a commercially available TGT. Additionally, we demonstrated that the TF/FXIa‐activated assay performs adequately by comparing potency measurements of five commercially available FVIII products using TGT and traditional chromogenic and one‐stage clotting assays. Conclusions The optimized TGT assay can be used to quantify and compare the thrombin generating capacities of FVIII concentrates.

Jha, N. K.↗

Data-driven optimized control of the COVID-19 epidemics

Optimizing the impact on the economy of control strategies aiming at containing the spread of COVID-19 is a critical challenge. We use daily new case counts of COVID-19 patients reported by local health administrations from different Metropolitan Statistical Areas (MSAs) within the US to parametrize a model that well describes the propagation of the disease in each area. We then introduce a time-varying control input that represents the level of social distancing imposed on the population of a given area and solve an optimal control problem with the goal of minimizing the impact of social distancing on the economy in the presence of relevant constraints, such as a desired level of suppression for the epidemics at a terminal time. We find that with the exception of the initial time and of the final time, the optimal control input is well approximated by a constant, specific to each area, which contrasts with the implemented system of reopening ‘in phases’. For all the areas considered, this optimal level corresponds to stricter social distancing than the level estimated from data. Proper selection of the time period for application of the control action optimally is important: depending on the particular MSA this period should be either short or long or intermediate. We also consider the case that the transmissibility increases in time (due e.g. to increasingly colder weather), for which we find that the optimal control solution yields progressively stricter measures of social distancing. We finally compute the optimal control solution for a model modified to incorporate the effects of vaccinations on the population and we see that depending on a number of factors, social distancing measures could be optimally reduced during the period over which vaccines are administered to the population.

60 APPLIED LIFE SCIENCES↗

Bi-Level Dynamic Optimization with Feedback

This paper considers a bi-level real-time algorithmic framework for networked systems, consisting of several local controllers and a central controller. The central controller issues setpoints to the local controllers to optimize their operational objectives while satisfying system-wide constraints. In this context, the paper develops an online algorithm for tracking the optimal solution of the underlying dynamic optimization problem. The design of the algorithm is based on a projected-gradient method, suitably modified to accommodate appropriate measurements (i.e., feedback). Optimality claims are established in terms of the dynamic regret of the algorithm; the latter is a natural performance criterion in nonstationary environments associated with real-time control problems. Finally, the application of the algorithm to real-time control of power setpoints in an electrical grid is illustrated.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Test of CP-invariance of the Higgs boson in vector-boson fusion production and in its decay into four leptons

A search for CP violation in the decay kinematics and vector-boson fusion production of the Higgs boson is performed in the H → ZZ * → 4 ℓ ( ℓ = e, μ ) decay channel. The results are based on proton-proton collision data produced at the LHC at a centre-of-mass energy of 13 TeV and recorded by the ATLAS detector from 2015 to 2018, corresponding to an integrated luminosity of 139 fb –1 . Matrix element-based optimal observables are used to constrain CP-odd couplings beyond the Standard Model in the framework of Standard Model effective field theory expressed in the Warsaw and Higgs bases. Differential fiducial cross-section measurements of the optimal observables are also performed, and a new fiducial cross-section measurement for vector-boson-fusion production is provided. All measurements are in agreement with the Standard Model prediction of a CP-even Higgs boson.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hypothesis-driven classification of materials using nuclear magnetic resonance relaxometry

Technologies related to identification of a substance in an optimized manner are provided. A reference group of known materials is identified. Each known material has known values for several classification parameters. The classification parameters comprise at least one of T.sub.1, T.sub.2, T.sub.1.rho., a relative nuclear susceptibility (RNS) of the substance, and an x-ray linear attenuation coefficient (LAC) of the substance. A measurement sequence is optimized based on at least one of a measurement cost of each of the classification parameters and an initial probability of each of the known materials in the reference group.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal Conductivity and Diffusivity for SiC Fibers for Use in ATF Cladding Composites

As part of the accident tolerant fuels (ATF) initiative, there is a need to understand the thermophysical properties of cladding for these fuels. One potential cladding material is silicon carbide (SiC) ceramic matrix composite reinforced with SiC fibers because of the corrosion resistance, resistance to hydrogen formation, high bulk thermal conductivity, and favorable mechanical properties of SiC. However, data about the thermal properties of individual SiC fibers in these composites is absent in the literature. This paper presents the measured axial thermal conductivity and thermal diffusivity of a leading SiC fiber (HiNicalon Type S) via a thermal measurement technique (transient electrothermal technique, TET) optimized for thin fibers. The results show that the measured properties are significantly lower than bulk values for SiC. Because of the low neutron absorption, as well as excellent thermal and mechanical properties, zircaloy has primarily been used for the fuel cladding in many nuclear reactors. A major drawback of the zircaloy is its hydrogen generation vulnerability. This issue has been known for some time, but the explosion of hydrogen accident in the Fukushima Daiichi nuclear disaster has motivated efforts for accident tolerant fuels (ATF) and their cladding as suitable substitutes for zircaloy. Fuel cladding made of silicon carbide (SiC) ceramic matrix composite (CMC) is an attractive alternative to the zircaloy. Investigation on the tubular monolithic a-SiC polytropes indicates that it has superior oxidation (hydrogen production) resistance (three orders of magnitude slower) than zircaloy. Additionally, it has well-documented, favorable mechanical properties, along with high temperature corrosion resistance. However, its bulk thermal properties can vary significantly depending on polytrope, the grain size, grain boundary, or impurities. At room temperature, SiC has a thermal conductivity as high as 490 Wm{sup -1}K{sup -1}, where the {sup 6}H polytrope has the highest conductivity. Thermal measurements of the SiC CMC are usually accomplished by laser flash method for thermal diffusivity (a) and thermal conductivity is indirectly calculated through the relationship k=aρcp. Depending on the manufacturing method and the reinforced fiber, the composite thermal conductivity varies from <10 Wm{sup -1}K{sup -1} to ∼70 Wm{sup -1}K{sup -1}. While the flash method is convenient for the measurement of the composite, it is difficult to apply to the measurement of individual fibers. Because of this, the thermal properties of individual SiC fibers is not present in the literature. Because the SiC fiber manufacturing process is different than that of the SiC matrix in the CMC, the properties of the bulk material might be erroneous when applied to the fiber. Being able to measure the fiber properties independently and directly allows for an understanding of the effect of the manufacturing process on the fiber and the opportunity to potentially improve or control the thermal properties of the composite. This improved accuracy can be achieved by measuring the fiber with a technique optimized for individual fiber measurement, known as the Transient Electrothermal Technique or TET. This paper presents the thermal conductivity and diffusivity of a leading SiC fiber (HiNicalon Type S). Measurements are performed with the TET, with the resulting properties being significantly lower than the bulk values of SiC, which is one possible explanation for relatively low CMC values. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of current density measurement methods for high-current, low-beta electron beams

Recent current density measurements with a low-beta electron beam (β=0.5-0.75) are strongly affected by electron scatter and Cherenkov limits. These invasive measurements are heavily influenced by the electron energy and the intercepting material properties: density, index of refraction, and atomic number. We evaluate various measurement methods, including x-ray scintillation and Cherenkov emission. To optimize the x-ray scintillation technique for this energy regime, metal foils of differing atomic number (Z) and thickness were placed upstream of a scintillation screen. We have selected Cherenkov emitters, based on a material refractive index, in order to differentiate the contributions from electron scatter and produced fluorescence, Cherenkov emission, and total internal reflection. The observed distributions for both approaches are verified through MCNP6®. Additionally, the simulations provide insight as to what physical processes dominate the measured distribution. We conclude by determining the limits and optimal measurement range for each measurement technique.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Data-Driven Performance Optimization of Gamma Spectrometers With Many Channels

In gamma spectrometers with variable spectroscopic performance across many channels (e.g., many pixels or voxels), a tradeoff exists between including data from successively worse-performing readout channels and increasing efficiency. Brute-force calculation of the optimal set of included channels is exponentially infeasible as the number of channels grows, and approximate methods are required. In this work, we present a data-driven framework for attempting to find near-optimal sets of included detector channels. The framework leverages non-negative matrix factorization (NMF) to learn the behavior of gamma spectra across the detector and clusters similarly-performing detector channels together. Performance comparisons are then made between spectra with channel clusters removed, which is more feasible than brute force. The framework is general and can be applied to arbitrary, user-defined performance metrics depending on the application. We apply this framework to optimizing gamma spectra measured by H3D M400 CdZnTe (CZT) spectrometers, which exhibit variable performance across their crystal volumes. In particular, we show several examples optimizing various performance metrics for uranium and plutonium gamma spectra in non-destructive assay (NDA) for nuclear safeguards, and explore trends in performance versus parameters such as clustering algorithm type. We also compare the NMF + clustering pipeline to several non-machine-learning (ML) algorithms, including several greedy algorithms. Although, we find that the NMF + clustering pipeline tends to find the best-performing set of detector voxels, significantly improving over the unoptimized spectra, but that a greedy accumulation of spectra segmented by detector depth can, in some cases, give similar performance improvements in much less computation time.

Energy resolution↗

SU-F-T-620: Development of a Convolution/Superposition Dose Engine for CyberKnife System

Purpose: Current CyberKnife treatment planning system (TPS) provided two dose calculation algorithms: Ray-tracing and Monte Carlo. Ray-tracing algorithm is fast, but less accurate, and also can’t handle irregular fields since a multi-leaf collimator system was recently introduced to CyberKnife M6 system. Monte Carlo method has well-known accuracy, but the current version still takes a long time to finish dose calculations. The purpose of this paper is to develop a GPU-based fast C/S dose engine for CyberKnife system to achieve both accuracy and efficiency. Methods: The TERMA distribution from a poly-energetic source was calculated based on beam’s eye view coordinate system, which is GPU friendly and has linear complexity. The dose distribution was then computed by inversely collecting the energy depositions from all TERMA points along 192 collapsed-cone directions. EGSnrc user code was used to pre-calculate energy deposition kernels (EDKs) for a series of mono-energy photons The energy spectrum was reconstructed based on measured tissue maximum ratio (TMR) curve, the TERMA averaged cumulative kernels was then calculated. Beam hardening parameters and intensity profiles were optimized based on measurement data from CyberKnife system. Results: The difference between measured and calculated TMR are less than 1% for all collimators except in the build-up regions. The calculated profiles also showed good agreements with the measured doses within 1% except in the penumbra regions. The developed C/S dose engine was also used to evaluate four clinical CyberKnife treatment plans, the results showed a better dose calculation accuracy than Ray-tracing algorithm compared with Monte Carlo method for heterogeneous cases. For the dose calculation time, it takes about several seconds for one beam depends on collimator size and dose calculation grids. Conclusion: A GPU-based C/S dose engine has been developed for CyberKnife system, which was proven to be efficient and accurate for clinical purpose, and can be easily implemented in TPS.

60 APPLIED LIFE SCIENCES↗

Quantum state tomography with fully symmetric measurements and product measurements

We introduce random-matrix theory to study the tomographic efficiency of a wide class of measurements constructed out of weighted 2-designs, including symmetric informationally complete (SIC) probability operator measurements (POMs). In particular, we derive analytic formulas for the mean Hilbert-Schmidt distance and the mean trace distance between the estimator and the true state, which clearly show the difference between the scaling behaviors of the two error measures with the dimension of the Hilbert space. We then prove that the product SIC POMs, the multipartite analog of the SIC POMs, are optimal among all product measurements in the same sense as the SIC POMs are optimal among all joint measurements. We further show that, for bipartite systems, there is only a marginal efficiency advantage of the joint SIC POMs over the product SIC POMs. In marked contrast, for multipartite systems, the efficiency advantage of the joint SIC POMs increases exponentially with the number of parties.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

System design of the ATS-F RFI measurement experiment.

Description of the system design of an RFI measurement experiment regarding optimal sharing of the 5.925- to 6.425-GHz frequency band between the ATS-F synchronous satellite and terrestrial telecommunication systems. The parametric measurements made will include transmitted and received power levels, propagation-path loss and variations as a function of range, elevation angle, RF polarization, and geographical location of interference sources. The technical objectives of the C-band RFI experiment are outlined, a functional diagram of the total system for the RFI measurement experiment is presented, and the design features of the receiver RF and IF circuits, the filters and detectors, and the computer control are summarized. A basic RFI measurement plan is presented which defines and briefly states the measurement procedure, which involves a number of different measurement modes, each of which is described in detail.

Henry, V. F.↗

Stochastic Waveform Estimation at the Fundamental Quantum Limit

Although measuring the deterministic waveform of a weak classical force is a well-studied problem, estimating a random waveform, such as the spectral density of a stochastic signal field, is much less well understood despite it being a widespread task at the frontier of experimental physics. State-of-the-art precision sensors of random forces must account for the underlying quantum nature of the measurement but the optimal quantum protocol for interrogating such linear sensors is not known. We derive the fundamental precision limit: the extended-channel quantum Cramér-Rao bound. In the experimentally relevant regime in which losses dominate, we prove that non-Gaussian-state preparation and measurement are required to achieve this fundamental limit and we determine numerically the optimal non-Gaussian protocol. We discuss how this scheme could accelerate searches for signatures of quantum gravity, stochastic gravitational waves, and axionic dark matter.

Axions↗

High-throughput feedback-enabled optogenetic stimulation and spectroscopy in microwell plates

Abstract The ability to perform sophisticated, high-throughput optogenetic experiments has been greatly enhanced by recent open-source illumination devices that allow independent programming of light patterns in single wells of microwell plates. However, there is currently a lack of instrumentation to monitor such experiments in real time, necessitating repeated transfers of the samples to stand-alone analytical instruments, thus limiting the types of experiments that could be performed. Here we address this gap with the development of the optoPlateReader (oPR), an open-source, solid-state, compact device that allows automated optogenetic stimulation and spectroscopy in each well of a 96-well plate. The oPR integrates an optoPlate illumination module with a module called the optoReader, an array of 96 photodiodes and LEDs that allows 96 parallel light measurements. The oPR was optimized for stimulation with blue light and for measurements of optical density and fluorescence. After calibration of all device components, we used the oPR to measure growth and to induce and measure fluorescent protein expression in E. coli . We further demonstrated how the optical read/write capabilities of the oPR permit computer-in-the-loop feedback control, where the current state of the sample can be used to adjust the optical stimulation parameters of the sample according to pre-defined feedback algorithms. The oPR will thus help realize an untapped potential for optogenetic experiments by enabling automated reading, writing, and feedback in microwell plates through open-source hardware that is accessible, customizable, and inexpensive.

59 BASIC BIOLOGICAL SCIENCES↗