Electron microscopic and biochemical characterization of Fraction 1 protein
High resolution electron microscopy of Fraction I protein from plant leaves
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
High resolution electron microscopy of Fraction I protein from plant leaves
Field ion microscopy of stoichiometric platinum and nickel alloys for atomic ordering parameters
Modern digital image processing hardware makes possible quantitative analysis of microscope images at high speed. This paper describes an application to automatic screening for cervical cancer. The system uses twelve MC6809 microprocessors arranged in a pipeline multiprocessor configuration. Each processor executes one part of the algorithm on each cell image as it passes through the pipeline. Each processor communicates with its upstream and downstream neighbors via shared two-port memory. Thus no time is devoted to input-output operations as such. This configuration is expected to be at least ten times faster than previous systems.
In one embodiment of the invention, a microscope or other observational apparatus, comprises a hollow tube, a lens mounted to the tube, a light source and at least one flexible optical fiber having an input end and an output end. The input end is positioned to receive light from the light source, and the output end is positioned within the tube so as to directly project light along a straight path to the lens to illuminate an object to be viewed. The path of projected light is uninterrupted and free of light deflecting elements. By passing the light through the lens, the light can be diffused or otherwise defocused to provide more uniform illumination across the surface of the object, increasing the quality of the image of the object seen by the viewer. The direct undeflected and uninterrupted projection of light, without change of direction, eliminates the need for light-deflecting elements, such as beam-splitters, mirrors, prisms, or the like, to direct the projected light towards the object.
Systems and methods for conducting electron or scanning probe microscopy are provided herein. In a general embodiment, the systems and methods for conducting electron or scanning probe microscopy with an undersampled data set include: driving an electron beam or probe to scan across a sample and visit a subset of pixel locations of the sample that are randomly or pseudo-randomly designated; determining actual pixel locations on the sample that are visited by the electron beam or probe; and processing data collected by detectors from the visits of the electron beam or probe at the actual pixel locations and recovering a reconstructed image of the sample.
This disclosure provides systems, methods, and apparatus related to optical microscopy. In one aspect, an apparatus includes a sample holder, a first objective lens, a plurality of optical components, a second objective lens, and a mirror. The apparatus may directly image a cross-section of a sample oblique to or parallel to the optical axis of the first objective lens, without scanning.
We report a simple chemical precipitation method for the preparation of undoped and cerium doped ZnO nanocrystals. The concentration of cerium in the products can be controlled in the range of 0.025–0.125 mol. The structure and chemical compositions of the products were characterized by X-ray diffraction, X-ray photoelectron spectroscopy; energy dispersive spectrum and Fourier transform infrared spectroscopy. The results demonstrate that Ce{sup 4+} ions were successfully incorporated into the lattice position of Zn{sup 2+} ions in ZnO. The morphology of the products was analyzed by field emission scanning electron microscopy and confirmed by high resolution transmission electron microscope analysis. The optical properties of the products were studied by ultraviolet–visible and room temperature photoluminescence measurements. The photoluminescence emission spectra of Ce-doped ZnO showed enhanced visible emissions as a result of 5d → 4f transition of cerium. In particular, a novel photocatalytic activity of the products was assessed using methylene blue. The obtained result reveals that Ce-doped products show higher reduction efficiency for methylene blue than the undoped ZnO. - Highlights: • Nanocrystals of ZnO and ZnO:Ce{sup 4+} were grown. • XPS results confirmed the incorporated cerium in tetravalence. • PL emission exhibited 5d → 4f transition on cerium doping. • Doped ZnO decolorizes MB faster than undoped ZnO.
We apply an array of correlated spatially-resolved techniques, including μ-Raman/photoluminescence/reflectance/laser-beam-induced-current in conjunction with scanning electron microscopy and atomic force microscopy, to study the impact of the microscopic-scale thickness inhomogeneity of CdS layer in a Cu{sub 2}ZnSnSe{sub 4} thin-film solar cell. Thicker CdS regions are found to cause more light reflecting loss thus yield lower external quantum efficiencies and energy conversion efficiencies than the general area. However, these regions show much less efficiency degradation at high illumination intensity, leading to an inversion of laser-beam-induced-current contrast in the area mapping. While improving the CdS layer uniformity can boost the device performance, the finding further points out the possibility of operating thin-film photovoltaic devices based on the similar materials (such as CuInGaSe{sub 2}, CdTe, Cu{sub 2}ZnSn(S,Se){sub 4}) under a substantially higher illumination density for concentrated photovoltaic and photo-detection.
Ternary nanocomposite silicon carbonitride (Si-C-N) ceramic coatings have shown potential for wear resistance, oxidation resistance, hardness, tunable band gap, and chemical inertness applications. A systematic investigation on the deposition of Si-C-N nanocomposite coatings by sputtering under varying deposition conditions such as chamber pressure, substrate temperature by structural, nanoindentation, and microstructural studies of optimized condition has been presented. Significant role of different deposition parameter on the mechanical and structural properties were observed. The structural characterizations of the coatings were carried out using Fourier transformed infra red (FTIR), transmission electron microscopy, Raman spectroscopy, and field emission scanning electron microscope. An increase in argon-nitrogen pressure in the range of 1-5 Pa led to lowering of particle size and surface smoothening and growth of hard phases of {beta}-C{sub 3}N{sub 4} and {beta}-Si{sub 3}N{sub 4}. An increase in substrate temperature from room temperature to 500 deg. C led to nucleation and growth of hard phases of {beta}-C{sub 3}N{sub 4} and Si{sub 3}N{sub 4} in the amorphous Si-C-N matrix. The nanoindentation studies showed the variation in hardness and Young's modulus from 8 to 22 GPa and from 100 to 240 GPa, respectively, dependent on the deposition conditions. The FTIR studies confirmed the presence of C-N, Si-N, Si-Si, Si-O, and Si-C in different films.
An alkali-free series of bioactive glasses has been designed and developed in the glass system CaO-MgO-SiO2-P2O5-CaF2 along diopside (CaMgSi2O6) – fluorapatite [Ca5(PO4)3F] – tricalcium phosphate (3CaO•P2O5) join. The silicate network in all the investigated glasses is predominantly coordinated in Q2 (Si) units while phosphorus tends to remain in orthophosphate (Q0) environment. The in vitro bioactivity analysis of glasses has been made by immersion of glass powders in simulated body fluid (SBF) while chemical degradation has been studied in Tris-HCl in accordance with ISO-10993-14. Some of the investigated glasses exhibit hydroxyapatite (HA) formation on their surface with in 1-12 h of their immersion in SBF solution. The sintering and crystallization kinetics of glasses has been investigated by differential thermal analysis (DTA) and hot-stage microscopy (HSM), respectively while the crystalline phase evolution in resultant glass-ceramics (GCs) has been studied in the temperature range of 800-900 oC using powder X-ray diffraction (XRD) and scanning electron microscope (SEM). The cell growth and osteogenic differentiation for glasses has been studied in vitro on sintered glass powder compacts using rat bone marrow mesenchymal stem cells. The as designed glasses are ideal candidates for their potential applications in bone tissue engineering in the form of bioactive glasses as well as glass/GC scaffolds.
Calibration of the optical lever sensitivities of atomic force microscope (AFM) cantilevers is especially important for determining the force in AFM measurements. These sensitivities depend critically on the cantilever mode used and are known to differ for static and dynamic measurements. Here, we calculate the ratio of the dynamic and static sensitivities for several common AFM cantilevers, whose shapes vary considerably, and experimentally verify these results. The dynamic-to-static optical lever sensitivity ratio is found to range from 1.09 to 1.41 for the cantilevers studied – in stark contrast to the constant value of 1.09 used widely in current calibration studies. This analysis shows that accuracy of the thermal noise method for the static spring constant is strongly dependent on cantilever geometry – neglect of these dynamic-to-static factors can induce errors exceeding 100%. We also discuss a simple experimental approach to non-invasively and simultaneously determine the dynamic and static spring constants and optical lever sensitivities of cantilevers of arbitrary shape, which is applicable to all AFM platforms that have the thermal noise method for spring constant calibration.
Hollow nanocubes of spinel Co{sub 3}O{sub 4} with the dimension of 20 nm were successfully prepared via a facile and reproducible solvothermal route. The structure and morphology of Co{sub 3}O{sub 4} nanoboxes were characterized by powder X-ray diffraction (XRD), scanning electron microscopy (SEM) and high-resolution transmission electron microscope (HRTEM) techniques. And a possible growth mechanism of Co{sub 3}O{sub 4} nanoboxes were suggested that solid Co{sub 3}O{sub 4} nanocubes nucleate in-situ and grow epitaxially from hexagonal {beta}-Co(OH){sub 2} precursors with the structural matching relationship of [0 0 1] {beta}-Co(OH){sub 2}//[1 1 1] Co{sub 3}O{sub 4}, and then solid Co{sub 3}O{sub 4} nanocubes gradually hollow and convert to single-crystal nanoboxes owing to Ostwald ripening. - Graphical abstract: The formation mechanism of Co{sub 3}O{sub 4} nanoboxes can be expressed as epitaxial growth of Co{sub 3}O{sub 4} nanocubes from {beta}-Co(OH){sub 2} nanoflakes due to a topotactic transformation and hollowing process owing to Ostwald ripening. Highlights: > Co{sub 3}O{sub 4} nanoboxes were prepared by a convenient, economical and controllable hydrothermal route. > Morphology and structure of Co{sub 3}O{sub 4} nanoboxes were characterized by XRD, SEM, and TEM techniques. > Co{sub 3}O{sub 4} nanoboxes grow epitaxially from Co(OH){sub 2} by topotactic transformation was suggested.
A serial block-face scanning electron microscopy (SBFSEM) system, composed of a scanning electron microscope (SEM) and an ultra-microtome installed within the SEM vacuum chamber, has been used to characterize the three-dimensional (3D) microstructure of tricalcium silicate (C 3 S) grains embedded in epoxy resin. A selection of C 3 S grains were segmented and rendered with 3D-image processing software, which allowed the C 3 S grains to be clearly visualized and enabled statistically quantitative analysis. The results show that about 5% of the C 3 S grains have volumes larger than 1 μm 3 and the average volume of the grains is 25 μm 3 . Pores can also be clearly seen in the biggest C 3 S grain, the volume of which is 3.6 × 10 4 μm 3 , and the mean volume and total volume of all the pores within this grain are 4.8 μm 3 and 3.0 × 10 3 μm 3 , respectively. This work provides a new approach for the characterization of the 3D spatial structure of raw C 3 S materials, and the resulting 3D structure of the raw C 3 S is important for further systematic research on the relationships between the spatial microstructure and the hydration kinetics of C 3 S and other cement minerals.
Modern transmission electron microscopes can image individual atoms and molecules. But to unlock new science, the next generation of instruments must look beyond just higher spatial resolution.
At the NASA Glenn Research Center, the Microgravity Science Program is planning to conduct a large number of experiments on the International Space Station in both the Fluid Physics and Combustion Science disciplines, and is developing flight experiment hardware for use within the International Space Station's Fluids and Combustion Facility. Four fluids physics experiments that require an optical microscope will be sequentially conducted within a subrack payload to the Fluids Integrated Rack of the Fluids and Combustion Facility called the Light Microscopy Module, which will provide the containment, changeout, and diagnostic capabilities to perform the experiments. The Light Microscopy Module is planned as a fully remotely controllable on-orbit microscope facility, allowing flexible scheduling and control of experiments within International Space Station resources. This paper will focus on the four microscope-based experiments, specifically, their objectives and the sample cell and instrument hardware to accommodate their requirements.
The goal of this project is to build a multimodal optical microscope to measure the binding, processive degradation, and pausing behaviors of cellulases as they interact with and degrade both synthetic and naturally occurring lignocellulosic walls. To achieve this, we will use high spatio-temporal single-molecule imaging to track cellulases, while visualizing specific molecular components of cellulose, lignin and hemicellulose, that make up their lignocellulose substrate. The microscope will combine Interferometric Scattering (iSCAT), which provides unprecedented spatiotemporal resolution; Total Internal Reflection Fluorescence (TIRF), which provides single-molecule resolution of multiple fluorophore-labeled molecules; and Stochastic Reconstruction (STORM), which allows for three-dimensional super-resolution imaging of intact plant cell walls during degradation. Initial studies will investigate cellulase dynamics on in vitro-assembled cell wall analogs, and later work will progress to using native plant cell walls.
Analytical tools of nanometre-scale resolution are indispensable in the fields of biology, physics and chemistry. One suitable tool, the soft X-ray microscope, provides high spatial resolution of visible light for wet specimens. For biological specimens, X-rays of water-window wavelength between carbon (284 eV; 4.3 nm) and oxygen (540 eV; 2.3 nm) absorption edges provide high-contrast imaging of biological samples in water. Among types of X-ray microscope, the transmission X-ray microscope using a synchrotron radiation source with diffractive zone plates offers the highest spatial resolution, approaching 15-10 nm. However, even higher resolution is required to measure proteins and protein complexes in biological specimens; therefore, a new type of X-ray microscope with higher resolution that uses a simple light source is desirable. Here we report a novel scanning-electron generation X-ray microscope (SGXM) that demonstrates direct imaging of unstained wet biological specimens. We deposited wet yeasts in the space between two silicon nitride (Si{sub 3}N{sub 4}) films. A scanning electron beam of accelerating voltage 5 keV and current 1.6 nA irradiates the titanium (Ti)-coated Si{sub 3}N{sub 4} film, and the soft X-ray signal from it is detected by an X-ray photodiode (PD) placed below the sample. The SGXM can theoretically achieve better than 5 nm resolution. Our method can be utilized easily for various wet biological samples of bacteria, viruses, and protein complexes.
'l'he relative value of different methods for combined light and electron microscopical studies of glycogen in the nervous tissue was investigated. Picroalcoholic fixatives preserve glycogen in a considerable amount but give an inadequate morphological image of glycogen distribution and are unsuitable for ultrastructural studies. Fixation by perfusion, with Dalton's chromeosmic fluid seems adequate for ultrastructural cytochemistry of glycogen. Furthermore it permits routine paraffin embedding of brain slices adjacent to those used for electron microscopy. Dimedone blocking is a necessary step for a selective staining of glycogen with PAS after osmic fixation. Enzymatic removal of glycogen in osmic fixed nervous tissue can be done In paraffin-embedded tissue. It can also be performed in glycolmethacrylate-embedded tissue without removal of the embedding medium. Paraphenylenediamine stains glycogen following periodic acid oxidation.