Search NASA⌕ Search

SEARCH · Search NASA

Results for “Model Counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Analysis of the low-energy electron-recoil spectrum of the CDMS experiment

We report on the analysis of the low-energy electron-recoil spectrum from the CDMS II experiment using data with an exposure of 443.2 kg-days. The analysis provides details on the observed counting rate and possible background sources in the energy range of 2-8.5 keV. We find no significant excess of a peaked contribution to the total counting rate above the background model, and compare this observation to the recent DAMA results. In the framework of a conversion of a dark matter particle into electromagnetic energy, our 90% confidence level upper limit of 0.246 events/kg/day at 3.15 keV is lower than the total rate above background observed by DAMA. In absence of any specific particle physics model to provide the scaling in cross section between NaI and Ge, we assume a Z{sup 2} scaling. With this assumption the observed rate in DAMA remains higher than the upper limit in CDMS. Under the conservative assumption that the modulation amplitude is 6% of the total rate we obtain upper limits on the modulation amplitude a factor of {approx}2 lower than observed by DAMA, constraining some possible interpretations of this modulation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-resolution photography of clouds from the surface: Retrieval of optical depth of thin clouds down to centimeter scales: High-Resolution Photography of Clouds

This article describes the approach and presents initial results, for a period of several minutes in north central Oklahoma, of an examination of clouds by high resolution digital photography from the surface looking vertically upward. A commercially available camera having 35-mm equivalent focal length up to 1200 mm (nominal resolution as fine as 6 µrad, which corresponds to 9 mm for cloud height 1.5 km) is used to obtain a measure of zenith radiance of a 30 m × 30 m domain as a two-dimensional image consisting of 3456 × 3456 pixels (12 million pixels). Downwelling zenith radiance varies substantially within single images and between successive images obtained at 4-s intervals. Variation in zenith radiance found on scales down to about 10 cm is attributed to variation in cloud optical depth (COD). Attention here is directed primarily to optically thin clouds, COD less than about 2. A radiation transfer model used to relate downwelling zenith radiance to COD and to relate the counts in the camera image to zenith radiance, permits determination of COD on a pixel-by-pixel basis. COD for thin clouds determined in this way exhibits considerable variation, for example, an order of magnitude within 15 m, a factor of 2 within 4 m, and 25% (0.12 to 0.15) over 14 cm. In conclusion, this approach, which examines cloud structure on scales 3 to 5 orders of magnitude finer than satellite products, opens new avenues for examination of cloud structure and evolution.

54 ENVIRONMENTAL SCIENCES↗

THE CENTRAL BLUE STRAGGLER POPULATION IN FOUR OUTER-HALO GLOBULAR CLUSTERS

Using Hubble Space Telescope/Wide Field Planetary Camera 2 data, we have performed a comparative study of the Blue Straggler Star (BSS) populations in the central regions of the globular clusters (GCs) AM 1, Eridanus, Palomar 3, and Palomar 4. Located at distances R{sub GC} > 50 kpc from the Galactic center, these are (together with Palomar 14 and NGC 2419) the most distant clusters in the halo. We determine their color-magnitude diagrams and centers of gravity. The four clusters turn out to have similar ages (10.5-11 Gyr), significantly smaller than those of the inner-halo globulars, and similar metallicities. By exploiting wide-field ground-based data, we build the most extended radial density profiles from resolved star counts ever published for these systems. These are well reproduced by isotropic King models of relatively low concentration. BSSs appear to be significantly more centrally segregated than red giants in all GCs, in agreement with the estimated core and half-mass relaxation times which are smaller than the cluster ages. Assuming that this is a signature of mass segregation, we conclude that AM 1 and Eridanus are slightly dynamically more evolved than Pal 3 and Pal 4.

79 ASTRONOMY AND ASTROPHYSICS↗

Estimating covariance matrices for two- and three-point correlation function moments in Arbitrary Survey Geometries

ABSTRACT We present configuration-space estimators for the auto- and cross-covariance of two- and three-point correlation functions (2PCF and 3PCF) in general survey geometries. These are derived in the Gaussian limit (setting higher order correlation functions to zero), but for arbitrary non-linear 2PCFs (which may be estimated from the survey itself), with a shot-noise rescaling parameter included to capture non-Gaussianity. We generalize previous approaches to include Legendre moments via a geometry-correction function calibrated from measured pair and triple counts. Making use of importance sampling and random particle catalogues, we can estimate model covariances in fractions of the time required to do so with mocks, obtaining estimates with negligible sampling noise in ∼10 (∼100) CPU-hours for the 2PCF (3PCF) autocovariance. We compare results to sample covariances from a suite of BOSS DR12 mocks and find the matrices to be in good agreement, assuming a shot-noise rescaling parameter of 1.03 (1.20) for the 2PCF (3PCF). To obtain strongest constraints on cosmological parameters, we must use multiple statistics in concert; having robust methods to measure their covariances at low computational cost is thus of great relevance to upcoming surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Systematically improvable multiscale solver for correlated electron systems

The development of numerical methods capable of simulating realistic materials with strongly correlated electrons, with controllable errors, is a central challenge in quantum many-body physics. Here we describe a framework for a general multiscale method based on embedding a self-energy of a strongly correlated subsystem into a self-energy generated by a method able to treat large weakly correlated systems approximately. As an example, we present the embedding of an exact diagonalization self-energy into a self-energy generated from self-consistent second-order perturbation theory. Using a quantum impurity model, generated from a cluster dynamical mean field approximation to the two-dimensional Hubbard model, as a benchmark, we illustrate that our method allows us to obtain accurate results at a fraction of the cost of typical Monte Carlo calculations. We test the method in multiple regimes of interaction strengths and dopings of the model. Here, the general embedding framework we present avoids difficulties such as double counting corrections, frequency-dependent interactions, or vertex functions. As it is solely formulated at the level of the single-particle Green's function, it provides a promising route for the simulation of realistic materials that are currently difficult to study with other methods.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Regression for Radioactive Source Detection

Detection of radioactive sources is an important capability that led to the deployment of networks for detecting and localizing low-level, hazardous radiation sources. It is generally expected that such networks outperform the individual detectors by intelligently fusing information from several dispersed sensors. In this paper, we develop a network detection method that uses the slope of a linear regression fit as a test statistic for detecting a point radioactive source within a field of detectors. In our regression model, we compute a least-squared linear fit between the average radiation counts at the detectors and the inverse-squared distances of known detector locations to an estimated source location. We show that the slope of this regression fit is an estimate of the source intensity and can be used as a threshold for source detection purposes. We compare performance of our proposed detection method with that of a fusion-based Sequential Probability Ratio Test (SPRT) method. For performance analyses, two datasets from the Domestic Nuclear Detection Ofces Intelligence Radiation Sensors Systems (IRSS) outdoor tests are used. Each of these tests consists of several runs of a single radioactive source moving in and out of a detector network. We present receiver operating characteristic (ROC) curves and optimal threshold values for the performance each detection method, and determine that our detection method using linear regression fit has slightly better overall performance than SPRT method.

Cordone, G.↗

TRIPLICATE SODIUM IODIDE GAMMA RAY MONITORS FOR THE SMALL COLUMN ION EXCHANGE PROGRAM

This technical report contains recommendations from the Analytical Development (AD) organization of the Savannah River National Laboratory (SRNL) for a system of triplicate Sodium Iodide (NaI) detectors to be used to monitor Cesium-137 ({sup 137}Cs) content of the Decontaminated Salt Solution (DSS) output of the Small Column Ion Exchange (SCIX) process. These detectors need to be gain stabilized with respect to temperature shifts since they will be installed on top of Tank 41 at the Savannah River Site (SRS). This will be accomplished using NaI crystals doped with the alpha-emitting isotope, Americium-241({sup 241}Am). Two energy regions of the detector output will be monitored using single-channel analyzers (SCAs), the {sup 137}Cs full-energy {gamma}-ray peak and the {sup 241}Am alpha peak. The count rate in the gamma peak region will be proportional to the {sup 137}Cs content in the DSS output. The constant rate of alpha decay in the NaI crystal will be monitored and used as feedback to adjust the high voltage supply to the detector in response to temperature variation. An analysis of theoretical {sup 137}Cs breakthrough curves was used to estimate the gamma activity expected in the DSS output during a single iteration of the process. Count rates arising from the DSS and background sources were predicted using Microshield modeling software. The current plan for shielding the detectors within an enclosure with four-inch thick steel walls should allow the detectors to operate with the sensitivity required to perform these measurements. Calibration, testing, and maintenance requirements for the detector system are outlined as well. The purpose of SCIX is to remove and concentrate high-level radioisotopes from SRS salt waste resulting in two waste streams. The concentrated high-level waste containing {sup 137}Cs will be sent to the Defense Waste Processing Facility (DWPF) for vitrification and the low-level DSS will be sent to the Saltstone Production Facility (SPF) to be incorporated into grout.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Seismic Fire Evaluation

This report describes an approach for modeling the number of ignitions (fires) following an earthquake. It is an update from a previous calculation (March 2012), “Modeling the Number of Ignitions Following an Earthquake: Developing Prediction Limits for Overdispersed Count Data,” performed by Elizabeth Kelly and Raymond Tell. This update incorporates comments from two reviews conducted by Douglas Honneger (March 2011) and Shane Reese (February 2013). Also, a comparison is made here with the Nuclear Regulatory Commission methodology developed by John Lambright for prediction of the likelihood of a seismically-induced fire for the resolution of Generic Issue 57, “Evaluation of Generic Issue 57: Effects of Fire Protection System Actuation on Safety-Related Equipment,” NUREG-5580.

42 ENGINEERING↗

GADRAS Batch Inject Tool User Guide

Gamma Detector Response and Analysis Software (GADRAS) is used by the radiation detection and emergency response community to perform modeling and spectral analysis for gamma detector systems. Built into GADRAS is the ability to define a detector, geometry, background characteristics and source composition to generate synthetic spectra for drills and exercises (injects). Consequence Management is currently in development of a sample result data simulator tool in which a deposition model is probed for source conditions at moments in time and locations in space. These values are used to generate realistic sample results for use in drills and exercises. In addition to sample results, there is a need to simulate the actual spectra that would be observed in the field by downlooking HPGe instruments given a deposition activity. This way, the FRMAC Gamma Spectroscopist can practice their process of generating quantified results from spectra on realistic data as well. Recognizing the decades of work done in GADRAS to accurately generate synthetic spectra, this team decided to build a link between the new simulator and GADRAS to generate these spectra quickly and easily. The simulator tool will generate a file that specifies the name of the spectra, its location, date/time of measurement, duration of measurement, height off the ground, and the deposition activity and age for every radionuclide in the simulation. Then, a new tool within the Inject Tab of GADRAS was developed to read in this file given a detector selection and generate In-Situ spectra for each row in the file in any file format the user chooses. This way, simulation cell staff can take these files and then upload them to the appropriate data system (RAMS or RadResponder) for use during drills and exercises. An advanced feature of this tool allows for generating any spectra given an appropriate model and mapping of source to model layer in the batch inject tool. This way, spectra from field sample counts, mobile laboratories, or even fixed laboratories can be generated in bulk given an estimate of the radioactivity concentration or total radioactivity in an import file. This expands the capabilities of this tool a great deal and will make it a more useful tool for CM and others to help estimate detector response for nearly any situation. This user guide will explain the steps needed to perform a batch inject file generation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Parameter Sensitivity Analysis of the SparTen High Performance Sparse Tensor Decomposition Software (Extended Analysis)

Tensor decomposition models play an increasingly important role in modern data science applications. One problem of particular interest is fitting a low-rank Canonical Polyadic (CP) tensor decomposition model when the tensor has sparse structure and the tensor elements are nonnegative count data. SparTen is a high-performance C++ library which computes a low-rank decomposition using different solvers: a first-order quasi-Newton or a second-order damped Newton method, along with the appropriate choice of runtime parameters. Since default parameters in SparTen are tuned to experimental results in prior published work on a single real-world dataset conducted using MATLAB implementations of these methods, it remains unclear if the parameter defaults in SparTen are appropriate for general tensor data. Furthermore, it is unknown how sensitive algorithm convergence is to changes in the input parameter values. This report addresses these unresolved issues with large-scale experimentation on three benchmark tensor data sets. Experiments were conducted on several different CPU architectures and replicated with many initial states to establish generalized profiles of algorithm convergence behavior.

97 MATHEMATICS AND COMPUTING↗

Harsh environments electronics : downhole applications.

The development and operational sustainment of renewable (geothermal) and non-renewable (fossil fuel) energy resources will be accompanied by increasingly higher costs factors: exploration and site preparation, operational maintenance and repair. Increased government oversight in the wake of the Gulf oil spill will only add to the cost burden. It is important to understand that downhole conditions are not just about elevated temperatures. It is often construed that military electronics are exposed to the upper limit in terms of extreme service environments. Probably the harshest of all service conditions for electronics and electrical equipment are those in oil, gas, and geothermal wells. From the technology perspective, advanced materials, sensors, and microelectronics devices are benefificial to the exploration and sustainment of energy resources, especially in terms of lower costs. Besides the need for the science that creates these breakthroughs - there is also a need for sustained engineering development and testing. Downhole oil, gas, and geothermal well applications can have a wide range of environments and reliability requirements: Temperature, Pressure, Vibration, Corrosion, and Service duration. All too frequently, these conditions are not well-defifined because the application is labeled as 'high temperature'. This ambiguity is problematic when the investigation turns to new approaches for electronic packaging solutions. The objective is to develop harsh environment, electronic packaging that meets customer requirements of cost, performance, and reliability. There are a number of challenges: (1) Materials sets - solder alloys, substrate materials; (2) Manufacturing process - low to middle volumes, low defect counts, new equipment technologies; and (3) Reliability testing - requirements documents, test methods and modeling, relevant standards documents. The cost to develop and sustain renewable and non-renewable energy resources will continue to escalate within the industry. Downhole electronics can provide a very cost-effective approach for well exploration and sustainment (data logging). However, the harsh environments are a 'game-changer' in terms defining materials, assembly processes and the long-term reliability of downhole electronic systems. The system-level approach will enable the integration of each of these contributors - materials, processes, and reliability - in order to deliver cost-effective electronics that meet customer requirements.

02 PETROLEUM↗

Afterpulsing in Silicon Photomultipliers: Impact on the Photodetectors Characterization

Novel generation of silicon-based photodetectors are attractive alternatives to the traditional phototubes. They offer significant advantages but they present new challenges too. Presence of afterpulses may affect many characteristics of the photodetectors. Simple statistical model of afterpulsing is used to evaluate the contribution to the observed dark count rates, to examine the contribution to the pulse height resolution and to demonstrate the modification of the observed timing properties of the SiPMs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Delayed Gamma-Ray Spectroscopy for Non-Destructive Assay of Nuclear Materials

High-­energy, beta-delayed gamma-­ray spectroscopy is a potential, non-­destructive assay techniques for the independent verification of declared quantities of special nuclear materials at key stages of the fuel cycle and for directly assaying nuclear material inventories for spent fuel handling, interim storage, reprocessing facilities, repository sites, and final disposal. Other potential applications include determination of MOX fuel composition, characterization of nuclear waste packages, and challenges in homeland security and arms control verification. Experimental measurements were performed to evaluate fission fragment yields, to test methods for determining isotopic fractions, and to benchmark the modeling code package. Experimental measurement campaigns were carried out at the IAC using a photo-­neutron source and at OSU using a thermal neutron beam from the TRIGA reactor to characterize the emission of high-­energy delayed gamma rays from 235 U, 239 Pu, and 241 Pu targets following neutron induced fission. Data were collected for pure and combined targets for several irradiation/spectroscopy cycle times ranging from 10/10 seconds to 15/30 minutes.The delayed gamma-ray signature of 241 Pu, a significant fissile constituent in spent fuel, was measured and compared to 239 Pu. The 241 Pu/ 239 Pu ratios varied between 0.5 and 1.2 for ten prominent lines in the 2700-­3600 keV energy range. Such significant differences in relative peak intensities make it possible to determine relative fractions of these isotopes in a mixed sample. A method for determining fission product yields by fitting the energy and time dependence of the delayed gamma-­ray emission was developed and demonstrated on a limited 235 U data set. De-­convolution methods for determining fissile fractions were developed and tested on the experimental data. The use of high count-­rate LaBr 3 detectors was investigated as a potential alternative to HPGe detectors. Modeling capabilities were added to an existing framework and codes were adapted as needed for analyzing experiments and assessing application-­specific assay concepts. A de-­convolution analysis of the delayed gamma-­ray response spectra modeled for spent fuel assemblies was performed using the same method that was applied to the experimental spectra.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Image-based spectral distortion correction for photon-counting x-ray detectors

Purpose: To investigate the feasibility of using an image-based method to correct for distortions induced by various artifacts in the x-ray spectrum recorded with photon-counting detectors for their application in breast computed tomography (CT). Methods: The polyenergetic incident spectrum was simulated with the tungsten anode spectral model using the interpolating polynomials (TASMIP) code and carefully calibrated to match the x-ray tube in this study. Experiments were performed on a Cadmium-Zinc-Telluride (CZT) photon-counting detector with five energy thresholds. Energy bins were adjusted to evenly distribute the recorded counts above the noise floor. BR12 phantoms of various thicknesses were used for calibration. A nonlinear function was selected to fit the count correlation between the simulated and the measured spectra in the calibration process. To evaluate the proposed spectral distortion correction method, an empirical fitting derived from the calibration process was applied on the raw images recorded for polymethyl methacrylate (PMMA) phantoms of 8.7, 48.8, and 100.0 mm. Both the corrected counts and the effective attenuation coefficient were compared to the simulated values for each of the five energy bins. The feasibility of applying the proposed method to quantitative material decomposition was tested using a dual-energy imaging technique with a three-material phantom that consisted of water, lipid, and protein. The performance of the spectral distortion correction method was quantified using the relative root-mean-square (RMS) error with respect to the expected values from simulations or areal analysis of the decomposition phantom. Results: The implementation of the proposed method reduced the relative RMS error of the output counts in the five energy bins with respect to the simulated incident counts from 23.0%, 33.0%, and 54.0% to 1.2%, 1.8%, and 7.7% for 8.7, 48.8, and 100.0 mm PMMA phantoms, respectively. The accuracy of the effective attenuation coefficient of PMMA estimate was also improved with the proposed spectral distortion correction. Finally, the relative RMS error of water, lipid, and protein decompositions in dual-energy imaging was significantly reduced from 53.4% to 6.8% after correction was applied. Conclusions: The study demonstrated that dramatic distortions in the recorded raw image yielded from a photon-counting detector could be expected, which presents great challenges for applying the quantitative material decomposition method in spectral CT. The proposed semi-empirical correction method can effectively reduce these errors caused by various artifacts, including pulse pileup and charge sharing effects. Furthermore, rather than detector-specific simulation packages, the method requires a relatively simple calibration process and knowledge about the incident spectrum. Therefore, it may be used as a generalized procedure for the spectral distortion correction of different photon-counting detectors in clinical breast CT systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scalable self attraction and loading calculations for unstructured ocean tide models

Self attraction and earth-loading effects are important for accurately modeling global tides. A common approach of handling this forcing is to expand mass anomalies into spherical harmonics, which are scaled by load Love numbers to account for elastic earth deformation. We investigate two different approaches to perform these calculations for ocean models that employ unstructured meshes and distributed memory parallelization. The first approach leverages a highly efficient spherical harmonics library, but requires all-to-one and one-to-all communications and interpolation operations between the unstructured and a structured mesh. This approach is compared to a parallel algorithm that computes the spherical harmonic transformations directly on the unstructured mesh with an all-reduce communication. Here, our results show that although the unstructured mesh calculations are more expensive, the scalability of the unstructured mesh approach allows for more efficient spherical harmonics transforms for high-resolution meshes and large processor counts. This methodology enables the efficient inclusion of tidal dynamics large-scale Earth system model simulations.

54 ENVIRONMENTAL SCIENCES↗

Long-term timing and glitch characteristics of anomalous X-ray pulsar 1RXS J170849.0–400910

We present the results of our detailed timing studies of an anomalous X-ray pulsar, 1RXS J170849.0–400910, using Rossi X-ray Timing Explorer (RXTE) observations spanning over ∼6 yr from 2005 until the end of the RXTE mission. We constructed the long-term spin characteristics of the source and investigated the time and energy dependence of the pulse profile and pulsed count rates. We find that the pulse profile and pulsed count rates in the 2-10 keV band do not show any significant variations in ∼6 yr. 1RXS J170849.0–400910 has been the most frequently glitching anomalous X-ray pulsar: three spin-up glitches and three candidate glitches were observed prior to 2005. Our extensive search for glitches later in the timeline resulted in no unambiguous glitches, though we identified two glitch candidates (with Δν/ν ∼ 10{sup –6}) in two data gaps: a strong candidate around MJD 55532 and another one around MJD 54819, which is slightly less robust. We discuss our results in the context of pulsar glitch models and expectancy of glitches within the vortex unpinning model.

79 ASTRONOMY AND ASTROPHYSICS↗

A Robot for Nondestructive Assay of Holdup Deposits in Gaseous Diffusion Piping - 19504

Miles of contaminated pipe must be characterized as part of the decommissioning effort at deactivated gaseous diffusion enrichment facilities. The current method requires cutting away asbestos- lined thermal enclosures and performing repeated, elevated operations to manually perform nondestructive assay (NDA) on pipe from the outside. The RadPiper robot, part of the Pipe Crawling Activity Measurement System (PCAMS) developed by Carnegie Mellon University and commissioned for use at the DOE Portsmouth Gaseous Diffusion Enrichment Facility, automatically measures U-235 in pipes from the inside. This improves certainty, increases safety, and greatly reduces measurement time. The heart of the RadPiper robot is a sodium iodide scintillation detector in an innovative disc-collimated assembly. By measuring from inside pipes, the robot significantly increases its count rate relative to external through-pipe measurements. The robot also provides imagery, models interior pipe geometry, and precisely measures distance in order to localize radiation measurements. Data collected by this system provides insight into pipe interiors that is simply not possible from exterior measurements, all while keeping operators safer. This paper describes the technical details of the PCAMS RadPiper robot. Key features for this robot include precision distance measurement, in-pipe obstacle detection, ability to transform for two pipe sizes, and robustness in autonomous operation. Test results demonstrating the robot's functionality are presented, including deployment tolerance tests, safeguarding tests, and localization tests. Integrated robot tests are also shown. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hierarchy of N-point functions in the {Lambda}CDM and ReBEL cosmologies

In this work we investigate higher-order statistics for the {Lambda}CDM and ReBEL scalar-interacting dark matter models by analyzing 180h{sup -1} Mpc dark matter N-body simulation ensembles. The N-point correlation functions and the related hierarchical amplitudes, such as skewness and kurtosis, are computed using the counts-in-cells method. Our studies demonstrate that the hierarchical amplitudes S{sub n} of the scalar-interacting dark matter model significantly deviate from the values in the {Lambda}CDM cosmology on scales comparable and smaller than the screening length r{sub s} of a given scalar-interacting model. The corresponding additional forces that enhance the total attractive force exerted on dark matter particles at galaxy scales lower the values of the hierarchical amplitudes S{sub n}. We conclude that hypothetical additional exotic interactions in the dark matter sector should leave detectable markers in the higher-order correlation statistics of the density field. We focused in detail on the redshift evolution of the dark matter field's skewness and kurtosis. From this investigation we find that the deviations from the canonical {Lambda}CDM model introduced by the presence of the 'fifth' force attain a maximum value at redshifts 0.5<z<2. We therefore conclude that moderate redshift data are better suited for setting observational constraints on the investigated ReBEL models.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗