Search NASA⌕ Search

SEARCH · Search NASA

Results for “Monte Carlo Simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Understanding of Ethanol Decomposition on Rh(111) From Density Functional Theory and Kinetic Monte Carlo Simulations

Reaction mechanisms of ethanol decomposition on Rh(1 1 1) were elucidated by means of periodic density functional theory (DFT) calculations and kinetic Monte Carlo (KMC) simulations. We propose that the most probable reaction pathway is via CH{sub 3}CH{sub 2}O* on the basis of our mechanistic study: CH{sub 3}CH{sub 2}OH* {yields} CH{sub 3}CH{sub 2}O* {yields} CH{sub 2}CH{sub 2}O* {yields} CH{sub 2}CHO* {yields} CH{sub 2}CO* {yields} CHCO* {yields} CH* + CO* {yields} C* + CO*. In contrast, the contribution from the pathway via CH{sub 3}CHOH* is relatively small, CH{sub 3}CH{sub 2}OH* {yields} CH{sub 3}CHOH* {yields} CH{sub 3}CHO* {yields} CH{sub 3}CO* {yields} CH{sub 2}CO* {yields} CHCO* {yields} CH* + CO* {yields} C* + CO*. According to our calculations, one of the slow steps is the formation of the oxametallacycle CH{sub 2}CH{sub 2}O* species, which leads to the production of CHCO*, the precursor for C-C bond breaking. Finally, the decomposition of ethanol leads to the production of C and CO. Our calculations, for ethanol combustion on Rh, the major obstacle is not C-C bond cleavage, but the C contamination on Rh(1 1 1). The strong C-Rh interaction may deactivate the Rh catalyst. The formation of Rh alloys with Pt and Pd weakens the C-Rh interaction, easing the removal of C, and, as expected, in accordance with the experimental findings, facilitating ethanol combustion.

30 DIRECT ENERGY CONVERSION↗

Application of adaptive multilevel splitting on coupled neutron-photon TRIPOLI-4{sup R} Monte Carlo simulations - 25427

In the context of radiation protection simulations, the Adaptive Multilevel Splitting (AMS) algorithm is a challenging variance reduction (VR) technique that has been recently investigated in the field of particle transport simulation. It has been implemented in the forthcoming version 11 of the Monte Carlo code TRIPOLI-4{sup R} and successfully tested in neutron-only and photon-only configurations. This paper addresses the application of the AMS algorithm to coupled simulations, and particularly to neutron-photon Monte Carlo calculations. The branching process occurring during the Monte Carlo coupled transport is taken into account in the new coupled-AMS algorithm and is explained in this paper. Two different neutron-photon configurations are then investigated, leading to a comparison of the coupled-AMS algorithm with the analog simulation on the one hand, and with the Exponential Transform (ET) on the other hand, which is the standard VR technique of TRIPOLI-4. Gains up to 30 are obtained in terms of Figure of Merit relatively to the analog simulation, which is about 4 to 6 times more efficient than the ET method for these configurations. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Morphological evolution of growing crystals - A Monte Carlo simulation

The combined effects of nutrient diffusion and surface kinetics on the crystal morphology were investigated using a Monte Carlo model to simulate the evolving morphology of a crystal growing from a two-component gaseous nutrient phase. The model combines nutrient diffusion, based on a modified diffusion-limited aggregation process, with anisotropic surface-attachment kinetics and surface diffusion. A variety of conditions, ranging from kinetic-controlled to diffusion-controlled growth, were examined. Successive transitions from compact faceted (dominant surface kinetics) to open dendritic morphologies (dominant volume diffusion) were obtained.

Xiao, Rong-Fu↗

WE-DE-BRA-05: Monte Carlo Simulation of a Novel Multi-Layer MV Imager

Purpose: To develop and validate a Monte Carlo (MC) model of a novel multi-layer imager (MLI) for megavolt (MV) energy beams. The MC model will enable performance optimization of the MLI design for clinical applications including patient setup verification, tumor tracking and MVCBCT. Methods: The MLI is composed of four layers of converter, scintillator and light detector, each layer similar to the current clinical AS1200 detector (Varian Medical Systems, Inc). The MLI model was constructed using the Geant4 Application for Tomographic Emission (GATE v7.1) and includes interactions for x-ray photons, charged particles and optical photons. Computational experiments were performed to assess Modulation Transfer Function (MTF), Detective Quantum Efficiency (DQE) and Noise Power Spectrum normalized by photon fluence and average detector signal (qNNPS). Results were compared with experimental measurements. The current work incorporates, in one model, the complete chain of events occurring in the imager; i.e. starting from x-ray interaction to charged particle transport and energy deposition to subsequent generation, interactions and detection of optical photons. Results: There is good agreement between measured and simulated MTF, qNNPS and DQE values. Normalized root mean squared error (NRMSE) between measured and simulated values over all four layers was 2.18%, 2.43% and 6.05% for MTF, qNNPS and DQE respectively. The relative difference between simulated and measured values for qNNPS(0) was 1.68% and 1.57% for DQE(0). Current results were obtained using a 6MV Varian Truebeam™ spectrum. Conclusion: A comprehensive Monte Carlo model of the MLI prototype was developed to allow optimization of detector components. The model was assessed in terms of imaging performance using standard metrics (i.e. MTF, qNNPS, DQE). Good agreement was found between simulated and measured values. The model will be used to assess alternative detector constructions to facilitate advanced clinical imaging applications including MV-CBCT and tumor tracking. The project was supported, partially, by a grant from Varian Medical Systems, Inc., and Award No. R01CA188446-01 from the National Cancer Institute. The content is solely the responsibility of the authors and does not necessarily represent the official views of the National Cancer Institute or the National Institutes of Health.

60 APPLIED LIFE SCIENCES↗

Monte Carlo Simulations of Defect Recovery within a 10 keV Collision Cascade in 3C-SiC

A kinetic lattice Monte Carlo (KLMC) model is developed to investigate the recovery and clustering of defects during annealing of a single 10 keV cascade in cubic silicon carbide. The 10 keV Si cascade is produced by molecular dynamics (MD), and a method of transferring the defects created by MD simulations to the KLMC model is developed. The KLMC model parameters are obtained from molecular dynamics simulations and ab initio calculations of defect migration, recombination and annihilation. The defects are annealed isothermally from 100 K to 1000 K in the KLMC model. Two distinct recovery stages for close Frenkel pairs are observed at about 200 and 550 K, and the growth of complex clusters is observed above 400 K. These simulation results are in good agreement with available experimental results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Monte-Carlo simulation of galactic cosmic ray effects in the lunar regolith

A Monte-Carlo soil mixing computer code was used to evaluate isotopic effects induced by galactic cosmic rays in samples on the top surface of the lunar regolith and in lunar core tubes. For surface samples, good agreement was found between theoretical predictions of Ne-21 concentrations, neutron fluences, and Xe-131/Xe-126 ratios, and the corresponding observations.

Langevin, Y.↗

Dosimetric accuracy of a deterministic radiation transport based {sup 192}Ir brachytherapy treatment planning system. Part III. Comparison to Monte Carlo simulation in voxelized anatomical computational models

Purpose: To compare TG43-based and Acuros deterministic radiation transport-based calculations of the BrachyVision treatment planning system (TPS) with corresponding Monte Carlo (MC) simulation results in heterogeneous patient geometries, in order to validate Acuros and quantify the accuracy improvement it marks relative to TG43. Methods: Dosimetric comparisons in the form of isodose lines, percentage dose difference maps, and dose volume histogram results were performed for two voxelized mathematical models resembling an esophageal and a breast brachytherapy patient, as well as an actual breast brachytherapy patient model. The mathematical models were converted to digital imaging and communications in medicine (DICOM) image series for input to the TPS. The MCNP5 v.1.40 general-purpose simulation code input files for each model were prepared using information derived from the corresponding DICOM RT exports from the TPS. Results: Comparisons of MC and TG43 results in all models showed significant differences, as reported previously in the literature and expected from the inability of the TG43 based algorithm to account for heterogeneities and model specific scatter conditions. A close agreement was observed between MC and Acuros results in all models except for a limited number of points that lay in the penumbra of perfectly shaped structures in the esophageal model, or at distances very close to the catheters in all models. Conclusions: Acuros marks a significant dosimetry improvement relative to TG43. The assessment of the clinical significance of this accuracy improvement requires further work. Mathematical patient equivalent models and models prepared from actual patient CT series are useful complementary tools in the methodology outlined in this series of works for the benchmarking of any advanced dose calculation algorithm beyond TG43.

60 APPLIED LIFE SCIENCES↗

Path integral Monte Carlo simulations of warm dense aluminum

Here, we perform first-principles path integral Monte Carlo (PIMC) and density functional theory molecular dynamics (DFT-MD) calculations to explore warm dense matter states of aluminum. Our equation of state (EOS) simulations cover a wide density-temperature range of $0.1-32.4$~g$\,$cm$^{-3}$ and $10^4-10^8$~K. Since PIMC and DFT-MD accurately treat effects of the atomic shell structure, we find two compression maxima along the principal Hugoniot curve attributed to K-shell and L-shell ionization. The results provide a benchmark for widely used EOS tables, such as SESAME, QEOS, and models based on Thomas-Fermi and average-atom techniques. A subsequent multi-shock analysis provides a quantitative assessment for how much heating occurs relative to an isentrope in multi-shock experiments. Finally, we compute heat capacity, pair-correlation functions, the electronic density of states, and Z to reveal the evolution of the plasma structure and ionization behavior.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Monte Carlo simulation of a biological object with optical coherent tomography structural images using a voxel-based geometry of a medium

We describe a Monte Carlo algorithm for simulating an interference signal and constructing a structural image of a biological object using optical coherent tomography (OCT). The algorithm is specific in that the object geometry is described by using a three-dimensional array of voxels combined into parallelograms, and the border cross checking is carried out by using an improved Smith algorithm. The geometry of the simulated object is reconstructed based on the structure of real biological tissues obtained by OCT. The algorithm efficiency is estimated by comparing experimental and corresponding simulated images of a subcutaneous blood vessel and upper layer of human skin in vivo . (biophotonics)

60 APPLIED LIFE SCIENCES↗

TH-A-19A-08: Intel Xeon Phi Implementation of a Fast Multi-Purpose Monte Carlo Simulation for Proton Therapy

Purpose: Recent studies have demonstrated the capability of graphics processing units (GPUs) to compute dose distributions using Monte Carlo (MC) methods within clinical time constraints. However, GPUs have a rigid vectorial architecture that favors the implementation of simplified particle transport algorithms, adapted to specific tasks. Our new, fast, and multipurpose MC code, named MCsquare, runs on Intel Xeon Phi coprocessors. This technology offers 60 independent cores, and therefore more flexibility to implement fast and yet generic MC functionalities, such as prompt gamma simulations. Methods: MCsquare implements several models and hence allows users to make their own tradeoff between speed and accuracy. A 200 MeV proton beam is simulated in a heterogeneous phantom using Geant4 and two configurations of MCsquare. The first one is the most conservative and accurate. The method of fictitious interactions handles the interfaces and secondary charged particles emitted in nuclear interactions are fully simulated. The second, faster configuration simplifies interface crossings and simulates only secondary protons after nuclear interaction events. Integral depth-dose and transversal profiles are compared to those of Geant4. Moreover, the production profile of prompt gammas is compared to PENH results. Results: Integral depth dose and transversal profiles computed by MCsquare and Geant4 are within 3%. The production of secondaries from nuclear interactions is slightly inaccurate at interfaces for the fastest configuration of MCsquare but this is unlikely to have any clinical impact. The computation time varies between 90 seconds for the most conservative settings to merely 59 seconds in the fastest configuration. Finally prompt gamma profiles are also in very good agreement with PENH results. Conclusion: Our new, fast, and multi-purpose Monte Carlo code simulates prompt gammas and calculates dose distributions in less than a minute, which complies with clinical time constraints. It has been successfully validated with Geant4. This work has been financialy supported by InVivoIGT, a public/private partnership between UCL and IBA.

07 ISOTOPE AND RADIATION SOURCES↗

Role of collisional broadening in Monte Carlo simulations of terahertz quantum cascade lasers

Using a generalized version of Fermi's golden rule, collisional broadening is self-consistently implemented into ensemble Monte Carlo carrier transport simulations, and its effect on the transport and optical properties of terahertz quantum cascade lasers is investigated. The inclusion of broadening yields improved agreement with the experiment, without a significant increase of the numerical load. Specifically, this effect is crucial for a correct modeling at low biases. In the lasing regime, broadening can lead to significantly reduced optical gain and output power, affecting the obtained current-voltage characteristics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Overcoming the Memory Bottleneck in Auxiliary Field Quantum Monte Carlo Simulations with Interpolative Separable Density Fitting

We investigate the use of interpolative separable density fitting (ISDF) as a means to reduce the memory bottleneck in auxiliary field quantum Monte Carlo (AFQMC) simulations of real materials in Gaussian basis sets. Here, we find that ISDF can reduce the memory scaling of AFQMC simulations from O(M 4 ) to O(M 2 ) . We test these developments by computing the structural properties of carbon in the diamond phase, comparing to results from existing computational methods and experiment. (LLNL-JRNL-759024)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spatially Continuous Depletion Algorithm for Monte Carlo Simulations

To correctly predict reactor behavior during cycle operations, the evolution of nuclide number densities throughout the core must be accurately modeled. The time-varying spatial distribution of nuclide number densities is typically resolved by discretizing the Monte Carlo geometry into smaller cells over which number densities are assumed to be spatially invariant. The nuclide number densities in these smaller cells are integrated through time using reaction rate tallies on the same discretized geometry. However, detailed distributions of nuclide number densities in a full three dimensional simulation can require a prohibitive amount of tallies, and the spatial discretization of the base geometry makes coupling to external multi-physics tools difficult. In this paper a method for solving for spatially continuous number density distributions during depletion calculations will be described. The spatially continuous number densities can be used in the transport method proposed by Brown and Martin which allows for transporting neutrons through a material with continuously varying properties such as temperature and nuclide number densities. Coupled with the ability of Functional Expansion Tallies (FETs) to represent tallied quantities as continuous functions, it is possible to both solve for and make use of spatially continuous nuclide number densities. The need for this capability was alluded to by Brown et. al., but no solution has yet been proposed. With a continuous depletion method, recent work which utilized FETs and continuous material tracking to incorporate multi-physics feedback in Monte Carlo simulations can be extended to simulations that include depletion analysis. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A comparison of HDR near source dosimetry using a treatment planning system, Monte Carlo simulation, and radiochromic film

This study aimed to investigate the high-dose rate Iridium-192 brachytherapy, including near source dosimetry, of a catheter-based applicator from 0.5 mm to 1 cm along the transverse axis. Radiochromic film and Monte Carlo (MC) simulation were used to generate absolute dose for the catheter-based applicator. Results from radiochromic film and MC simulation were compared directly to the treatment planning system (TPS) based on the American Association of Physicists in Medicine Updated Task Group 43 (TG-43U1) dose calculation formalism. The difference between dose measured using radiochromic film along the transverse plane at 0.5 mm from the surface and the predicted dose by the TPS was 24%±13%. The dose difference between the MC simulation along the transverse plane at 0.5 mm from the surface and the predicted dose by the TPS was 22.1%±3%. For distances from 1.5 mm to 1 cm from the surface, radiochromic film and MC simulation agreed with TPS within an uncertainty of 3%. The TPS under-predicts the dose at the surface of the applicator, i.e., 0.5 mm from the catheter surface, as compared to the measured and MC simulation predicted dose. MC simulation results demonstrated that 15% of this error is due to neglecting the beta particles and discrete electrons emanating from the sources and not considered by the TPS, and 7% of the difference was due to the photon alone, potentially due to the differences in MC dose modeling, photon spectrum, scoring techniques, and effect of the presence of the catheter and the air gap. Beyond 1 mm from the surface, the TPS dose algorithm agrees with the experimental and MC data within 3%.

61 RADIATION PROTECTION AND DOSIMETRY↗

OBJECT KINETIC MONTE CARLO SIMULATIONS OF RADIATION DAMAGE IN TUNGSTEN

We used our recently developed lattice-based object kinetic Monte Carlo code; KSOME [1] to carryout simulations of radiation damage in bulk tungsten at temperatures of 300, and 2050 K for various dose rates. Displacement cascades generated from molecular dynamics (MD) simulations for PKA energies at 60, 75 and 100 keV provided residual point defect distributions. It was found that the number density of vacancies in the simulation box does not change with dose rate while the number density of vacancy clusters slightly decreases with dose rate indicating that bigger clusters are formed at larger dose rates. At 300 K, although the average vacancy cluster size increases slightly, the vast majority of vacancies exist as mono-vacancies. At 2050 K no accumulation of defects was observed during irradiation over a wide range of dose rates for all PKA energies studied in this work.

Nandipati, Giridhar↗

Kinetic Monte Carlo simulation of dopant-defect systems under submicrosecond laser thermal processes

An innovative Kinetic Monte Carlo (KMC) code has been developed, which rules the post-implant kinetics of the defects system in the extremely far-from-the equilibrium conditions caused by the laser irradiation close to the liquid-solid interface. It considers defect diffusion, annihilation and clustering. The code properly implements, consistently to the stochastic formalism, the fast varying local event rates related to the thermal field T(r,t) evolution. This feature of our numerical method represents an important advancement with respect to current state of the art KMC codes. The reduction of the implantation damage and its reorganization in defect aggregates are studied as a function of the process conditions. Phosphorus activation efficiency, experimentally determined in similar conditions, has been related to the emerging damage scenario.

36 MATERIALS SCIENCE↗

Molecular-Atomic Transition along the Deuterium Hugoniot Curve with Coupled Electron-Ion Monte Carlo Simulations

We have performed accurate simulations of the Deuterium Hugoniot using Coupled Electron Ion Monte Carlo (CEIMC). Using highly accurate quantum Monte Carlo methods for the electrons, we study the region of maximum compression along the principal Hugoniot, where the system undergoes a continuous transition from a molecular fluid to a monatomic fluid. We include all relevant physical corrections so that a direct comparison to experiment can be made. Around 50 GPa we found a maximum compression of 4.85, roughly 10% larger than previous theoretical predictions and experimental data but still compatible with the latter because of their large uncertainty.

74 ATOMIC AND MOLECULAR PHYSICS↗