Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operational amplifier”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Design of the American Mobile Satellite System

This paper presents an overview of the American Mobile Satellite Corporation (AMSC) Mobile Satellite System (MSS). A summary of the mobile satellite (MSAT) design and overall performance is provided. The design and components of both the forward link and return link transponders are described in detail. The design and operation of a unique hybrid matrix amplifier that offers flexible power distribution is outlined. The conceptual design and performance of three types of land mobile antennas are described.

Kittiver, Charles↗

Self-Calibrating and Remote Programmable Signal Conditioning Amplifier System and Method

A self-calibrating, remote programmable signal conditioning amplifier system employs information read from a memory attached to a measurement transducer for automatic calibration. The signal conditioning amplifier is self-calibrated on a continuous basis through use of a dual input path arrangement, with each path containing a multiplexer and a programmable amplifier. A digital signal processor controls operation of the system such that a transducer signal is applied to one of the input paths, while one or more calibration signals are applied to the second input path. Once the second path is calibrated, the digital signal processor switches the transducer signal to the second path. and then calibrates the first path. This process is continually repeated so that each path is calibrated on an essentially continuous basis. Dual output paths are also employed which are calibrated in the same manner. The digital signal processor also allows the implementation of a variety of digital filters which are either programmed into the system or downloaded by an operator, and performs up to eighth order linearization.

Medelius, Pedro J.↗

Field intercomparison of a novel optical sensor for formaldehyde quantification

A one-week in situ intercomparison campaign was completed on the Rice University campus for measuring HCHO using three different techniques, including a novel optical sensor based on difference frequency generation (DFG) operating at room temperature. Two chemical derivatization methods, 2,4-dinitrophenylhydrazine (DNPH) and o-(2,3,4,5,6-pentafluorobenzyl) hydroxylamine (PFBHA), were deployed during the daylight hours for three- to four-hour time-integrated samples. A real-time optical sensor based on laser absorption spectroscopy was operated simultaneously, including nighttime hours. This tunable spectroscopic source based on difference frequency mixing of two fiber-amplified diode lasers in periodically poled LiNb03 (PPLN) was operated at 3.5315 micrometers (2831.64 cm 1) to access a strong HCHO ro-vibrational transition free of interferences from other species. The results showed a bias of -1.7 and -1.2 ppbv and a gross error of 2.6 and 1.5 ppbv for DNPH and PFBHA measurements, respectively, compared with DFG measurements. These results validate the DFG sensor for time-resolved measurements of HCHO in urban areas.

NASA Discipline Life Sciences Technologies↗

Method and system for compact and efficient high energy pulsed laser amplifier

An optical amplifier system includes an input aperture operable to receive light propagating along an optical path in a first direction and a first polarizer disposed along the optical path. The first polarizer is operable to pass light having a polarization state aligned with a first polarization axis. The system also includes a first Pockels cell operable to receive light passing through the first polarizer, an optical gain element disposed along the optical path, a second Pockels cell disposed along the optical path, and a second polarizer disposed along the optical path. The second polarizer is operable to pass light having a polarization state aligned with the first polarization axis. The system further includes a first mirror operable to receive light reflected from the second polarizer, a second mirror operable to receive light reflected from the first polarizer, and an output aperture operable to transmit light passing through the second polarizer.

47 OTHER INSTRUMENTATION↗

Switch device having a non-linear transmission line

Switching devices are provided. The switching devices include an input electrode, having a main electrode and a trigger electrode, and an output electrode. The main electrode and the trigger electrode are separated from the output electrode by a main gap and a trigger gap, respectively. During operation, the trigger electrode compresses and amplifies a trigger voltage signal causing the trigger electrode to emit a pulse of energy. This pulse of energy form plasma near the trigger electrode, either by arcing across the trigger gap, or by arcing from the trigger electrode to the main electrode. This plasma decreases the breakdown voltage of the main gap. Simultaneously, or near simultaneously, a main voltage signal propagates through the main electrode. The main voltage signal emits a main pulse of energy that arcs across the main gap while the plasma formed by the trigger pulse is still present.

47 OTHER INSTRUMENTATION↗

Techniques for Achieving High Reliability Operation of the Spallation Neutron Source High Power Radio-Frequency System

The Spallation Neutron Source (SNS) high power radiofrequency (HPRF) system operates with high reliability to support the goals of the SNS user program. In recent operational periods the availability of the HPRF system has exceeded 97 percent while the neutron source availability overall is typically greater than 90 percent. SNS has a unique set of 92 HPRF stations that operate at either 402.5 MHz or 805 MHz with peak output power ranging from 550 kW to 5 MW and average power ranging from 49.5 kW to 450 kW. The HPRF transmitters consist of chassis-mounted power supplies, solid-state amplifiers and other equipment that support the operation of the klystrons that ultimately provide the RF power to the accelerating structures. Management of the operation and maintenance of the HPRF system has increasingly focused on reliability and sustainability in recent years. Techniques for klystron lifetime preservation and optimization of transmitter reliability have been developed and will be described.

Moss, John↗

A Likelihood Search for Low-mass Dark Matter via Inelastic Scattering in SuperCDMS

An abundance of evidence suggests that most of the Universe is composed of nonluminous matter. This "dark matter” is believed to be a new elementary particle and experiments around the world are attempting to directly detect rare collisions with terrestrial detectors.The properties of dark matter have yet to be identified, thus efforts are ongoing to explore a range of possible masses and interaction cross-sections. For the latter, experiments can increase exposure by scaling up the detector mass and operating for a longer time. To search for dark matter with less mass than a nucleon, new technologies and analysis techniques need to be developed to be sensitive to energy deposits less than a few keV.SuperCDMS is a direct detection experiment that measures ionization and phonon energy in cryogenic germanium crystal detectors. A special mode of operating the SuperCDMS detectors, called CDMSlite, amplifies the ionization signal via phonon creation. This amplification leads to a lower energy threshold, which provides sensitivity to smaller dark matter masses.Typically, direct detection experiments assume dark matter scatters elastically off the nuclei in the detector. In this thesis, I will highlight the most recent CDMSlite elastic dark matter search. Then I will describe how inelastic dark matter collisions can manifest in the detector and be useful for extending experimental sensitivity to lower dark matter masses. Finally, I will present a re-analysis of CDMSlite data using a profile likelihood to search for low-mass dark matter through two inelastic scattering channels: Bremsstrahlung radiation, and the Migdal Effect.

79 ASTRONOMY AND ASTROPHYSICS↗

Higher-order dispersion compensating pulse shaper via amplitude spectral filtering and nonlinear phase accumulation

A method of pulse shaping using spectral filtering, positive chirp, and self-phase modulation to control the accumulated higher-order phase terms of the spectral phase. This pulse shaping method has particular advantage in fiber chirped pulse amplification (FCPA) systems, where there are two effects: (1) an offsetting of the fourth order phase via nonlinear phase accumulation, allowing for a higher Strehl ratio (i.e., a cleaner pulse), higher peak power pulse and (2) enabling power scaling to higher pulse energies without the increased nonlinear phase accumulation leading to pulse breakup. This technique can be used both in a passive system with no amplification to clean up an existing pulse, and in an amplifier system to enable higher performance operation (shorter pulses, cleaner pulses, higher energy pulses).

Domingue, Scott R.↗

Development of a semi-adiabatic isoperibol solution calorimeter

A semi-adiabatic isoperibol solution calorimeter has been indigenously developed. The measurement system comprises modules for sensitive temperature measurement probe, signal processing, data collection, and joule calibration. The sensitivity of the temperature measurement module was enhanced by using a sensitive thermistor coupled with a lock-in amplifier based signal processor. A microcontroller coordinates the operation and control of these modules. The latter in turn is controlled through personal computer (PC) based custom made software developed with LabView. An innovative summing amplifier concept was used to cancel out the base resistance of the thermistor. The latter was placed in the dewar. The temperature calibration was carried out with a standard platinum resistance (PT100) sensor coupled with an 8½ digit multimeter. The water equivalent of this calorimeter was determined by using electrical calibration with the joule calibrator. The experimentally measured values of the quantum of heat were validated by measuring heats of dissolution of pure KCl (for endotherm) and tris (hydroxyl methyl) amino-methane (for exotherm). The uncertainity in the measurements was found to be within ±3%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A wavelength scannable XeCl oscillator-ring amplifier laser system

A holographic grating at grazing angle of incidence was used to achieve tunable, narrow bandwidth (0.005 nm) operation of a XeCl oscillator for injection locking of a ring amplifier. The amplifier's narrow bandwidth output energy was constant and equal to the untuned, broadband output (approximately 15 mJ) in regions where injection locking was achieved. Scanning was provided by use of a stepping motor-driven differential micrometer on the tuning mirror. This system was used to produce a laser excitation spectrum of hydroxyl radicals (OH) in a flame.

Pacala, T. J.↗

Improved traveling wave tubes

Techniques, pioneered by NASA, which will allow substantial improvements in traveling wave tube (TWT) amplifier efficiency, are described. It is shown that using design techniques developed at the Lewis Research Center, it is possible to approximately double the efficiency of the critical amplifier TWT. Attention is given to a quick method of computing the expected improvement to an ECM TWT. The benefits of such improvements such as less input power, a smaller and lighter power supply, and easier cooling are surveyed, and it noted that it is now possible to build efficient TWT's which rather than operating at saturation, can be very linear amplifiers. Finally, a new approach to power supplies is also covered.

Buck, E.↗

Range Resolved CO2 Atmospheric Backscattering Measurements Using Fiber Lasers and RZPN Code Modulation

We report the use of a return-to- zero (RZPN) pseudo noise modulation technique for making range resolved measurements of CO2 within the planetary boundary layer (PBL) using commercial, off-the-shelf, components. Conventional, range resolved, DIAL measurements require laser pulse widths that are significantly shorter than the desired spatial resolution and necessitate using pulses whose temporal spacing is such that scattered returns from only a single pulse are observed by the receiver at any one time (for the PBL pulse separations must be greater than approximately 20 microseconds). This imposes significant operational limitations when using currently available fiber lasers because of the resulting low duty cycle (less than approximately 0.0005) and consequent low average laser output power. The RZPN modulation technique enables a fiber laser to operate at much higher duty cycles (approaching 0.04) thereby more effectively utilizing the amplifier's output. This increases the counts received by approximately two orders of magnitude. Our approach involves employing two distributed feedback lasers (DFB), each modulated by a different RPZN code, whose outputs are then amplified by a CW fiber amplifier. One laser is tuned to a CO2 absorption line; the other operates offline thereby permitting the simultaneous acquisition of both on and offline signals using independent RZPN codes. This minimizes the impact of atmospheric turbulence on the measurement. The on and offline signals are retrieved by deconvolving the return signal using the appropriate kernels.

Burris, John↗

Advanced radiographic imaging techniques.

Examination of the nature and operational constraints of conventional X-radiographic and neutron imaging methods, providing a foundation for a discussion of advanced radiographic imaging systems. Two types of solid-state image amplifiers designed to image X rays are described. Operational theory, panel construction, and performance characteristics are discussed. A closed-circuit television system for imaging neutrons is then described and the system design, operational theory, and performance characteristics are outlined. Emphasis is placed on a description of the advantages of these imaging systems over conventional methods.

Beal, J. B.↗

New detection system and signal processing for the tokamak ISTTOK heavy ion beam diagnostic

The tokamak ISTTOK heavy ion beam diagnostic (HIBD) operates with a multiple cell array detector (MCAD) that allows for the plasma density and the plasma density fluctuations measurements simultaneously at different sampling volumes across the plasma. To improve the capability of the plasma density fluctuations investigations, a new detection system and new signal conditioning amplifier have been designed and tested. The improvements in MCAD design are presented which allow for nearly complete suppression of the spurious plasma background signal by applying a biasing potential onto special electrodes incorporated into MCAD. The new low cost and small size transimpedance amplifiers are described with the parameters of 400 kHz, 10{sup 7} V/A, 0.4 nA of RMS noise, adequate for the plasma density fluctuations measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical amplifier based on guided polaritons in GaN and ZnO

We propose a scheme of an optical amplifier based on GaN and ZnO waveguides operating in the regime of strong coupling between photonic modes and excitonic resonances. Amplification of the guided exciton-polaritons is obtained by stimulated scattering from the excitonic reservoir, which is found to be fast enough compared with the large velocity of the guided polariton modes. We analyze the device parameters at different temperatures. We find that an 80 μm-long amplifier can provide a gain of 10 dB at room temperature, being supplied by 5 mA current in the cw regime.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fiber-Based Laser MOPA Transmitter Packaging for Space Environment

NASA’s Goddard Space Flight Center has been developing lidar to remotely measure CO2 and CH4 in the Earth’s atmosphere. The ultimate goal is to make space-based satellite measurements with global coverage. We are working on maturing the technology readiness of a fiber-based, 1.57-micron wavelength laser transmitter designed for use in atmospheric CO2 remote-sensing. To this end, we are building a ruggedized prototype to demonstrate the required power and performance and survive the required environment. We are building a fiber-based master oscillator power amplifier (MOPA) laser transmitter architecture. The laser is a wavelength-locked, single frequency, externally modulated DBR operating at 1.57-micron followed by erbium-doped fiber amplifiers. The last amplifier stage is a polarization-maintaining, very-large-mode-area fiber with ~1000 μm2 effective area pumped by a Raman fiber laser. The optical output is single-frequency, one microsecond pulses with >450 μJ pulse energy, 7.5 KHz repetition rate, single spatial mode, and > 20 dB polarization extinction.

Lasers and Masers↗

Performance of the HIRS/2 instrument on TIROS-N

The High Resolution Infrared Radiation Sounder (HIRS/2) was developed and flown on the TIROS-N satellite as one means of obtaining atmospheric vertical profile information. The HIRS/2 receives visible and infrared spectrum radiation through a single telescope and selects 20 narrow radiation channels by means of a rotating filter wheel. A passive radiant cooler provides an operating temperature of 106.7 K for the HgCdTe and InSb detectors while the visible detector operates at instrument frame temperature. Low noise amplifiers and digital processing provide 13 bit data for spacecraft data multiplexing and transmission. The qualities of system performance that determine sounding capability are the dynamic range of data collection, the noise equivalent radiance of the system, the registration of the air columns sampled in each channel and the ability to upgrade the calibration of the instrument to maintain the performance standard throughout life. The basic features, operating characteristics and performance of the instrument in test are described. Early orbital information from the TIROS-N launched on October 13, 1978 is given and some observations on system quality are made.

Koenig, E. W.↗

MMIC DHBT Common-Base Amplifier for 172 GHz

Figure 1 shows a single-stage monolithic microwave integrated circuit (MMIC) power amplifier in which the gain element is a double-heterojunction bipolar transistor (DHBT) connected in common-base configuration. This amplifier, which has been demonstrated to function well at a frequency of 172 GHz, is part of a continuing effort to develop compact, efficient amplifiers for scientific instrumentation, wide-band communication systems, and radar systems that will operate at frequencies up to and beyond 180 GHz. The transistor is fabricated from a layered structure formed by molecular beam epitaxy in the InP/InGaAs material system. A highly doped InGaAs base layer and a collector layer are fabricated from the layered structure in a triple mesa process. The transistor includes two separate emitter fingers, each having dimensions of 0.8 by 12 m. The common-base configuration was chosen for its high maximum stable gain in the frequency band of interest. The input-matching network is designed for high bandwidth. The output of the transistor is matched to a load line for maximum saturated output power under large-signal conditions, rather than being matched for maximum gain under small-signal conditions. In a test at a frequency of 172 GHz, the amplifier was found to generate an output power of 7.5 mW, with approximately 5 dB of large-signal gain (see Figure 2). Moreover, the amplifier exhibited a peak small-signal gain of 7 dB at a frequency of 176 GHz. This performance of this MMIC single-stage amplifier containing only a single transistor represents a significant advance in the state of the art, in that it rivals the 170-GHz performance of a prior MMIC three-stage, four-transistor amplifier. [The prior amplifier was reported in "MMIC HEMT Power Amplifier for 140 to 170 GHz" (NPO-30127), NASA Tech Briefs, Vol. 27, No. 11 (November 2003), page 49.] This amplifier is the first heterojunction- bipolar-transistor (HBT) amplifier built for medium power operation in this frequency band. The performance of the amplifier as measured in the aforementioned tests suggests that InP/InGaAs HBTs may be superior to high-electron-mobility (HEMT) transistors in that the HBTs may offer more gain per stage and more output power per transistor.

Paidi, Vamsi↗