Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optical sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Optical Device for Converting a Laser Beam into Two Co-aligned but Oppositely Directed Beams

Optical systems consisting of a series of optical elements require alignment from the input end to the output end. The optical elements can be mirrors, lenses, sources, detectors, or other devices. Complex optical systems are often difficult to align from end-to-end because the alignment beam must be inserted at one end in order for the beam to traverse the entire optical path to the other end. The ends of the optical train may not be easily accessible to the alignment beam. Typically, when a series of optical elements is to be aligned, an alignment laser beam is inserted into the optical path with a pick-off mirror at one end of the series of elements. But it may be impossible to insert the beam at an end-point. It can be difficult to locate the pick-off mirror at the desired position because there is not enough space, there is no mounting surface, or the location is occupied by a source, detector, or other component. Alternatively, the laser beam might be inserted at an intermediate location (not at an end-point) and sent, first in one direction and then the other, to the opposite ends of the optical system for alignment. However, in this case, alignment must be performed in two directions and extra effort is required to co-align the two beams to make them parallel and coincident, i.e., to follow the same path as an end-to-end beam. An optical device has been developed that accepts a laser beam as input and produces two co-aligned, but counter-propagating beams. In contrast to a conventional alignment laser placed at one end of the optical path, this invention can be placed at a convenient position within the optical train and aligned to send its two beams simultaneously along precisely opposite paths that, taken together, trace out exactly the same path as the conventional alignment laser. This invention allows the user the freedom to choose locations within the optical train for placement of the alignment beam. It is also self-aligned by design and requires almost no adjustment.

Jennings, Donald↗

Optical observations of HEAO-B objects

Positions and error circles of optically unidentified X-ray sources near the galactic plane were used to carry out searches within and around the error circles for optical counterparts for these sources. Forty-nine X-ray fields were searched in the course of 42 nights of observation and 62 individual stellar objects were studied. No optical identifications of the X-ray sources were made.

Mook, D. E.↗

Spatial Light Modulators as Optical Crossbar Switches

A proposed method of implementing cross connections in an optical communication network is based on the use of a spatial light modulator (SLM) to form controlled diffraction patterns that connect inputs (light sources) and outputs (light sinks). Sources would typically include optical fibers and/or light-emitting diodes; sinks would typically include optical fibers and/or photodetectors. The sources and/or sinks could be distributed in two dimensions; that is, on planes. Alternatively or in addition, sources and/or sinks could be distributed in three dimensions -- for example, on curved surfaces or in more complex (including random) three-dimensional patterns.

Juday, Richard↗

Temporal resolution and fidelity enhancement of arbitrary waveforms

An apparatus, comprising: Mach-Zehnder modulators (MZMs) numbered MZM #1 to MZM #n that exhibit nonlinearity between an input electrical domain signal and an output optical domain signal; a waveform source for applying a first voltage waveform to a first optical arm of said MZM #1; a laser source configured to direct laser light into the two arms of at least said MZM #1 to produce a first output optical domain signal; the apparatus being provided for utilizing said first output optical signal and the nonlinearities of MZMs numbered MZM #2 to said MZM #n to produce a final output voltage waveform that, compared to said input voltage, comprises at least one of: a shorter rise time, a shorter fall time, an increased signal temporal resolution or small signal dynamic range, an increased vertical resolution for small signals or large signals, a reduced noise on small signals or large signals and an increased bandwidth.

Muir, Ryan D.↗

Deep-space optical channel. 1: Noise mechanisms

The noise due to various sources in the deep space optical channel with a space based receiver is analyzed. It is found that the worst case conditions occur during the encounter phase with planets.

Katz, J.↗

Optical systolic solutions of linear algebraic equations

The philosophy and data encoding possible in systolic array optical processor (SAOP) were reviewed. The multitude of linear algebraic operations achievable on this architecture is examined. These operations include such linear algebraic algorithms as: matrix-decomposition, direct and indirect solutions, implicit and explicit methods for partial differential equations, eigenvalue and eigenvector calculations, and singular value decomposition. This architecture can be utilized to realize general techniques for solving matrix linear and nonlinear algebraic equations, least mean square error solutions, FIR filters, and nested-loop algorithms for control engineering applications. The data flow and pipelining of operations, design of parallel algorithms and flexible architectures, application of these architectures to computationally intensive physical problems, error source modeling of optical processors, and matching of the computational needs of practical engineering problems to the capabilities of optical processors are emphasized.

Neuman, C. P.↗

The discovery of an X-ray selected, radio-loud quasar at z = 3.9

About 600 weak X-ray sources from a data base of about 100,000 2-4sigma fluctuations derived from Einstein Observatory imaging proportional counter X-ray images are selected on the basis of a flux-limited catalog of radio sources in the northern sky. Optical spectroscopy of only six of these sources resulted in the discovery of a quasar with an emission-line redshift of 3.87. Subsequent VLA observations reveal the source to have a flat-spectrum radio core plus an unresolved radio lobe 2.5 arcsec away with a spectral index of 1.45. The lobe is connected to the core by a weak jet. The integrated flux density of the source at 20 cm is 0.66 Jy. The v magnitude of the quasar is 19.5, and the tentative X-ray sources has a very soft spectrum. The properties of this object are discussed in the context of known high-redshift radio sources and existing X-ray selected quasar samples, and the potential of the present discovery technique for examining the properties of very distant active galaxies is explored.

Becker, R. H.↗

Multisensor Instrument for Real-Time Biological Monitoring

The figure schematically depicts an instrumentation system, called a fiber optic-based integration system (FOBIS), that is undergoing development to enable real-time monitoring of fluid cell cultures, bioprocess flows, and the like. The FOBIS design combines a micro flow cytometer (MFC), a microphotometer (MP), and a fluorescence-spectrum- or binding-force-measuring micro-sensor (MS) in a single instrument that is capable of measuring multiple biological parameters simultaneously or sequentially. The fiber-optic-based integration system is so named because the MFC, the MP, and the MS are integrated into a single optical system that is coupled to light sources and photometric equipment via optical fibers. The optical coupling components also include a wavelength-division multiplexer and diffractive optical elements. The FOBIS includes a laserdiode- and fiber-optic-based optical trapping subsystem (optical tweezers ) with microphotometric and micro-sensing capabilities for noninvasive confinement and optical measurement of relevant parameters of a single cell or other particle. Some of the measurement techniques implemented together by the FOBIS have long been used separately to obtain basic understanding of the optical properties of individual cells and other organisms, the optical properties of populations of organisms, and the interrelationships among these properties, physiology of the organisms, and physical processes that govern the media that surround the organisms. For example, flow cytometry yields information on numerical concentrations, cross-sectional areas, and types of cells or other particles. Micro-sensing can be used to measure pH and concentrations of oxygen, carbon dioxide, glucose, metabolites, calcium, and antigens in a cell-culture fluid, thereby providing feedback that can be helpful in improving control over a bioprocess. Microphotometry (including measurements of scattering and fluorescence) can yield further information about optically trapped individual particles. In addition to the multifunctionality not previously available in a single biological monitoring system, the FOBIS offers advantages of low mass, sensitivity, accuracy, portability, low cost, compactness (the overall dimensions of the fully developed FOBIS sensor head are expected to be less than 1 by 1 by 2 cm), and immunity to electromagnetic interference at suboptical frequencies. FOBIS could be useful in a variety of laboratory and field settings in such diverse endeavors as medical, veterinary, and general biological research; medical and veterinary diagnosis monitoring of industrial bioprocesses; and analysis of biological contaminants in air, water, and food.

Zhang, Sean (Zhanxiang)↗

Optimization of neutron chopper and optics for CENTAUR, the SANS/WANS diffractometer at the spallation neutron source second target station

Herein this report presents the physics design and optimization of the neutron chopper and optics systems for the CENTAUR instrument, a multifunctional small-angle and wide-angle neutron scattering diffractometer for the Spallation Neutron Source Second Target Station. This instrument will offer a wide range of capabilities, including small-angle neutron scattering with wide Q coverage (e.g., 0.001–20 Å –1 ), providing a tool to investigate structures from atomic to mesoscopic scales simultaneously. To efficiently transport desired neutrons from the compact high-brightness cold source, several innovative designs are utilized: a time-zero chopper with a straight guide system for short-wavelength neutrons, octagonal guides for higher flux, and a correlation chopper to reduce inelastic scattering. The optimization process considers factors such as useable time-integrated flux, instrument resolution, brilliance transfer, divergence, and acceptance diagram uniformity. The overall design prioritizes flexibility to accommodate diverse user requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Long term X-ray observations of systems with unusual optical counterparts and modulation measurement of selected astronomical sources

The OAO-3 satellite was used for several months' observation of the loss mass X-ray binary sources 2A18822-371 and 4U2129+47 in a search for variability similar to the 35 day on-off cycle observed in Her X-1. The related system Cyg X-2 was observed both optically and in X-rays covering one complete binary cycle of 9.8 days. The UCL X-ray telescope observations revealed no periodities nor obvious variability other than the known orbital periods; however, the ground-based optical spectroscopy supports the interpretation of the photometry periodicities as representing orbital motion in 2A1822-371 and detected radial velocity motions on the photometric period in 4U2129+47. The shape and the length of the 4.8 hour periodicity in the X-ray emission from Cyg X-3 was also studied. The quality OAO-3 data obtained to measure the light curve and look for a change in the period and/or obtain improved measurement of the slope of the light curve was insufficient.

Bowyer, C. S.↗

A precise position and optical identification for 4U 2129+47 - X-ray heating and a 5.2 hour binary period

A precise (20 arcsec) position and an optical counterpart are presented for the weak X-ray source 4U 2129+47. The optical counterpart shows weak but distinct He II 4686-A and C III-N III 4640-4650-A emission. Both H-beta and Ca II H and K are sometimes visible in absorption. Numerous plates and spectrophotometric observations from the 1978 observing season show that the blue magnitude varies from 16.7 to 18.0 in a period of 5.2382 hours. The light curve is sinusoidal in appearance, but with sharply defined V-shaped minima. It is proposed that most of the optical emission from this system originates at the X-ray heated face of the normal star and hence that this system is analogous to HZ Her/Her X-1. This is one of the few intrinsically faint optical counterparts of X-ray sources that show clear evidence of binary nature. The observations suggest a distance of 1.2-1.6 kpc for the source, and a consequent X-ray luminosity of approximately 10 to the 34.8 ergs/s.

Thorstensen, J.↗

A Modified Algorithm and Open-Source Computational Package for the Determination of Infrared Optical Constants Relevant to Astrophysics

Infrared (IR) telescopes, such as Spitzer and SOFIA, have revealed a rich variety of chemical species trapped in interstellar ices. The most fundamental parameters to be derived from observed IR spectra are the identity and abundance of each component. Several compounds have been conclusively or tentatively identified, but the band strengths and optical constants needed to derive accurate abundances for many of these are poorly constrained. We have developed a modified approach to the extraction of the real and imaginary parts of the refractive index (optical constants) of a thin film from a single transmission spectrum measured in the IR spectral range. Our algorithm is similar to those implemented by previous authors, with some major changes that yield results for strong absorptions where previous approaches fail: (1) an adaptive k-correction step size, (2) the use of a root-finding algorithm to obtain a more accurate k-correction at each iteration, and (3) a k-correction step that prevents non-physical results such as negative n-values that prevent convergence in the calculation algorithm. The algorithm is presented and described, with examples to show agreement with some existing results and improvements upon others. New optical-constants calculations for CH3OH, CO2, N2O, and CH4 are presented, and potential implications for the modeling of interstellar and planetary ice data from space telescopes are discussed. With the objective of being open-source and transparent, the full source code in the free Python programming language is made available along with the compiled version and the laboratory data used to produce the results shown.

Perry A. Gerakines↗

Selectively accessing the hotspots of optical nanoantennas by self-aligned dry laser ablation

Plasmonic nanostructures serve as optical antennas for concentrating the energy of incoming light in localized hotspots close to their surface. By positioning nanoemitters in the antenna hotspots, energy transfer is enabled, leading to novel hybrid antenna-emitter-systems, where the antenna can be used to manipulate the optical properties of the nano-objects. The challenge remains how to precisely position emitters within the hotspots. We report a self-aligned process based on dry laser ablation of a calixarene that enables the attachment of molecules within the electromagnetic hotspots at the tips of gold nanocones. Within the laser focus, the ablation threshold is exceeded in nanoscale volumes, leading to selective access of the hotspot areas. A first indication of the site-selective functionalization process is given by attaching fluorescently labelled proteins to the nanocones. In a second example, Raman-active molecules are selectively attached only to nanocones that were previously exposed in the laser focus, which is verified by surface enhanced Raman spectroscopy. Enabling selective functionalization is an important prerequisite e.g. for preparing single photon sources for quantum optical technologies, or multiplexed Raman sensing platforms.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Measurements of X-ray source positions by the scanning modulation collimator on HEAO 1

This paper reports preliminary results on the positions of X-ray sources obtained with the modulation collimator on the first NASA High Energy Astronomy Observatory, HEAO 1. Calibration on Sco X-1 establishes the experiment capabilities to be within 7 sec as limited by aspect errors. For the reported X-ray sources certain ambiguities in their positions are resolved and the previous optical identifications of four sources are confirmed, two of which are X-ray bursters and one of which is the black hole candidate Cir X-1. An accurate position for a new transient source is also presented.

Gursky, H.↗

Sparse Matrix-Based HPC Tomography

Tomographic imaging has benefited from advances in X-ray sources, detectors and optics to enable novel observations in science, engineering and medicine. These advances have come with a dramatic increase of input data in the form of faster frame rates, larger fields of view or higher resolution, so high performance solutions are currently widely used for analysis. Tomographic instruments can vary significantly from one to another, including the hardware employed for reconstruction: from single CPU workstations to large scale hybrid CPU/GPU supercomputers. Furthermore, flexibility on the software interfaces and reconstruction engines are also highly valued to allow for easy development and prototyping. This paper presents a novel software framework for tomographic analysis that tackles all aforementioned requirements. The proposed solution capitalizes on the increased performance of sparse matrix-vector multiplication and exploits multi-CPU and GPU reconstruction over MPI. Furthermore, the solution is implemented in Python and relies on CuPy for fast GPU operators and CUDA kernel integration, and on SciPy for CPU sparse matrix computation. As opposed to previous tomography solutions that are tailor-made for specific use cases or hardware, the proposed software is designed to provide flexible, portable and high-performance operators that can be used for continuous integration at different production environments, but also for prototyping new experimental settings or for algorithmic development. The experimental results demonstrate how our implementation can even outperform state-of-the-art software packages used at advanced X-ray sources worldwide.

97 MATHEMATICS AND COMPUTING↗

Three-dimensional range imaging apparatus and method

A three-dimensional range imager includes a light source for providing a modulated light signal, a multiplexer, an optical fiber connecting the light source to the multiplexer, a plurality of optical fibers connected at first ends to the multiplexer and at second ends to a first fiber array, and a transmitter optic disposed adjacent the first fiber array for projecting a pixel pattern of the array onto a target.

Scott, Vibart Stan↗

The scanning modulation collimator experiment on the HEAO-1

The purpose of this experiment is to localize celestial sources of X-rays to a precision of 5 to 20 arcsec, so that they may be identified with optical or radio counterparts. We also study their angular size and structure, to elucidate the X-ray emission mechanism. Four grids, wound with nickel alloy wires, are aligned to produce a modulated X-ray signal when the spacecraft rotation carries the collimator field of view across an X-ray source. An image dissector star camera and rate integrating gyroscopes are used to deduce the celestial position from which a peak X-ray signal arises. On-orbit performance and thermal stability have been very good. Based on the first six weeks of quick look data, we have the following results: the location of an X-ray burst source within a globular cluster; the location of 4U1608-52, a unique object which shows bursting, transient, and steady X-ray behavior and is also an optical source; the location of the X-ray transient H1705-25, which provided Anglo-Australian astronomers the basis for an optical identification with a nova-like object; the location of the X-ray transient H1743-32 in the galactic center; and a precise measurement of the angular extent of the Crab Nebula.

Schwartz, D. A.↗

Designing high-power, octave spanning entangled photon sources for quantum spectroscopy

Entangled photon spectroscopy is a nascent field that has important implications for measurement and imaging across chemical, biology, and materials fields. Entangled photon spectroscopy potentially offers improved spatial and temporal-frequency resolutions, increased cross sections for multiphoton and nonlinear measurements, and new abilities in inducing or measuring quantum correlations. A critical step in enabling entangled photon spectroscopies is the creation of high-flux entangled sources that can use conventional detectors as well as provide redundancy for the losses in realistic samples. Here, we report a periodically poled, chirped, lithium tantalate platform that generates entangled photon pairs with ~10 -7 efficiency. For a near watt level diode laser, this results in a near μW-level flux. The single photon per mode limit that is necessary to maintain non-classical photon behavior is still satisfied by distributing this power over up to an octave-spanning bandwidth. The spectral–temporal photon correlations are observed via a Michelson-type interferometer that measures the broadband Hong–Ou–Mandel two-photon interference. A coherence time of 245 fs for a 10 nm bandwidth in the collinear case and a coherence time of 62 fs for a 125 nm bandwidth in the non-collinear case are measured using a CW pump laser and, essentially, collecting the full photon cone. We outline in detail the numerical methods used for designing and tailoring the entangled photons source, such as changing center wavelength or bandwidth, with the ultimate aim of increasing the availability of high-flux UV–Vis entangled photon sources in the optical spectroscopy community.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗