Search NASA⌕ Search

SEARCH · Search NASA

Results for “PHASE CHANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Pump-probe X-ray Diffraction Technique for Irreversible Phase Change Materials

We have developed a pump-probe X-ray diffraction measurement system for a sample with irreversible reaction at BL40XU in the SPring-8. The system mainly consists of a time-resolved measurement system, a sample disk rotation system, and an X-ray microbeam system. The time-resolved measurement system gives time resolution of 50 ps in laser-pump and X-ray probe method. A sample disk rotation system for repetitive measurements was made to give a virgin sample for every measurement. The number of repetitions for one sample disk was increased by using the X-ray microbeam technique. To keep the overlap of the X-ray microbeam and the laser beam on the sample surface during the disk rotation, the sample disk rotation system was constructed by a low-eccentric spindle motor. By using this system, the pump-probe X-ray diffraction measurement was demonstrated for a crystallization process of a DVD material.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electrical Control of Magnetic Resonance in Phase Change Materials

Metal–insulator transitions (MITs) in resistive switching materials can be triggered by an electric stimulus that produces significant changes in the electrical response. When these phases have distinct magnetic characteristics, dramatic changes in the spin excitations are also expected. The transition metal oxide La 0.7 Sr 0.3 MnO 3 (LSMO) is a ferromagnetic metal at low temperatures and a paramagnetic insulator above room temperature. When LSMO is in its metallic phase, a critical electrical bias has been shown to lead to an MIT that results in the formation of a paramagnetic resistive barrier transverse to the applied electric field. Using spin-transfer ferromagnetic resonance spectroscopy, we show that even for electrical biases less than the critical value that triggers the MIT, there is magnetic phase separation, with the spin-excitation resonances varying systematically with applied bias. Therefore, voltage-triggered MITs in LSMO can alter magnetic resonance characteristics, offering an effective method for tuning synaptic weights in neuromorphic circuits.

36 MATERIALS SCIENCE↗

Multifidelity methods for uncertainty quantification of a nonlocal model for phase changes in materials

This study is devoted to the construction of a multifidelity Monte Carlo (MFMC) method for the uncertainty quantification of a nonlocal, non-mass-conserving Cahn-Hilliard model for phase transitions with an obstacle potential. Here, we are interested in estimating the expected value of an output of interest (OoI) that depends on the solution of the nonlocal Cahn-Hilliard model. As opposed to its local counterpart, the nonlocal model captures sharp interfaces without the need for significant mesh refinement. However, the computational cost of the nonlocal Cahn-Hilliard model is higher than that of its local counterpart with similar mesh refinement, inhibiting its use for outer-loop applications such as uncertainty quantification. The MFMC method augments the desired high-fidelity, high-cost OoI with a set of lower-fidelity, lower-cost OoIs to alleviate the computational burden associated with nonlocality. Most of the computational budget is allocated to sampling the cheap surrogate models to achieve speedup, whereas the high-fidelity model is sparsely sampled to maintain accuracy. For the non-mass-conserving nonlocal Cahn-Hilliard model, the use of the MFMC method results in, for a given computational budget, about an order of magnitude reduction in the mean-squared error of the expected value of the OoI relative to that of the Monte Carlo method.

97 MATHEMATICS AND COMPUTING↗

Paraffin Phase Change Material for Maintaining Temperature Stability of IceCube Type of CubeSats in LEO

The MLA and IFA of the instrument on the IceCube require a 20 C temperature and a thermal stability of +/-1 C. The thermal environment of the ISS orbit for the IceCube is very unstable due to solar beta angles in the -75deg to +75deg range. Additionally the instrument is powered off in every eclipse to conserve electrical power. These two factors cause thermal instability to the MLA and IFA. This paper presents a thermal design of using mini paraffin PCM packs to meet the thermal requirements of these instrument components. With a 31 g mass plus a 30% margin of n-hexadecane, the MLA and IFA are powered on for 32.3 minutes in sunlight at a 0deg beta angle to melt the paraffin. The powered-on time increases to 38 minutes at a 75deg (+/-) beta angle. When the MLA and IFA are powered off, the paraffin freezes.

CubeState↗