Search NASA⌕ Search

SEARCH · Search NASA

Results for “PROFILE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

FoXS: a web server for rapid computation and fitting of SAXS profiles

Small angle X-ray scattering (SAXS) is an increasingly common technique for low-resolution structural characterization of molecules in solution. SAXS experiment determines the scattering intensity of a molecule as a function of spatial frequency, termed SAXS profile. SAXS profiles can contribute to many applications, such as comparing a conformation in solution with the corresponding X-ray structure, modeling a flexible or multi-modular protein, and assembling a macromolecular complex from its subunits. These applications require rapid computation of a SAXS profile from a molecular structure. FoXS (Fast X-Ray Scattering) is a rapid method for computing a SAXS profile of a given structure and for matching of the computed and experimental profiles. Here, we describe the interface and capabilities of the FoXS web server (http://salilab.org/foxs).

59 BASIC BIOLOGICAL SCIENCES↗

Shock compression of silver to 300 GPa: Wave profile measurements and melting transition

Recent in-situ x-ray diffraction (XRD) measurements on laser-shock compressed Ag foils demonstrated a face-centered-cubic to body-centered-cubic transformation at ~150 GPa and melting between 172 and 197 GPa [Phys. Rev. Lett. 124, 235701 (2020)]. As a complement to the XRD work, we conducted plate impact experiments to obtain shock velocity and wave profile measurements on thicker Ag samples shock-compressed to peak stresses between 30 and 300 GPa. The shock velocity–particle velocity results were fitted very well by a linear relation over the entire stress range, providing an accurate determination of the Ag Hugoniot (locus of the stress-volume states achieved under shock compression). For peak stresses below 187 GPa and above 210 GPa—corresponding to the solid and liquid phases, respectively—the wave profiles show clean single waves. No wave profile features related to the fcc-bcc transformation at ~150 GPa were observed, implying minimal volume change for the transformation. For stresses between 187 and 210 GPa, an initial jump was followed by a time-dependent increase in the particle velocity (20–80 ns risetime) to the peak state—corresponding to the solid-liquid mixed phase response. Unlike the solid and liquid response, the mixed-phase response cannot be readily analyzed analytically. Instead, numerical simulations incorporating an accurate multiphase equation of state for Ag—not currently available—are required to analyze the wave profiles measured at 187–210 GPa stresses. Furthermore, the present work shows the potential for using wave profile measurements to examine the melting transition under shock compression.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Strong gravity extruding peaks in speed of sound profiles of massive neutron stars

The speed of sound squared (SSS) s 2 in massive neutron stars (NSs) characterizes not only the stiffness of supradense neutron-rich matter within but also equivalently properties of the curved geometry due to the strong-field gravity and matter-geometry coupling. A peaked density or radius profile of s 2 has been predicted for massive NSs using various NS equation of state (EOS) models. However, the nature, cause, location and size of the peak in s 2 profiles are still very EOS model dependent. In this work, we investigate systematically s 2 profiles in massive NSs in a new approach that is independent of the nuclear EOS model and without any presumption about the NS structure and/or composition. In terms of the small quantities (reduced radius, the energy density and pressure scaled by their central values), we perform double-element perturbative expansions in solving perturbatively the scaled Tolman-Oppenheimer-Volkoff (TOV) equations and analyzing s 2 profiles from the Newtonian limit to the general relativistic (GR) case. The GR term in the TOV equations plays a twofold role: it compresses NS matter and modifies the pressure/energy density ratio from small values in Newtonian stars showing no s 2 peak to large ones for massive NSs possessing a peak in their s 2 profiles, and eventually takes away the peak in extremely compact/massive NSs approaching the causality limit. In particular, the peaked behavior in s 2 is expected to emerge near the center of massive NSs like PSR J⁢0740+6620, while a sharp phase transition is unlikely to occur there. Furthermore, these features revealed from our analyses are universal as they are intrinsic properties of the GR stellar structure equations independent of the still very uncertain EOS of supradense neutron-rich matter in NSs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Imprint of primordial non-Gaussianity on dark matter halo profiles

We study the impact of primordial non-Gaussianity on the density profile of dark matter halos by using the semi-analytical model introduced recently by Dalal {\it et al.} which relates the peaks of the initial linear density field to the final density profile of dark matter halos. Models with primordial non-Gaussianity typically produce an initial density field that differs from that produced in Gaussian models. We use the path-integral formulation of excursion set theory to calculate the non-Gaussian corrections to the peak profile and derive the statistics of the peaks of non-Gaussian density field. In the context of the semi-analytic model for halo profiles, currently allowed values for primordial non-Gaussianity would increase the shapes of the inner dark matter profiles, but only at the sub-percent level except in the very innermost regions.

79 ASTRONOMY AND ASTROPHYSICS↗

Self-consistent, high-order spatial profiles in a model for two-fluid turbulent mixing

A Reynolds-averaged Navier-Stokes model is presented with the property that it admits self-consistent, high-order spatial profiles in simulations of two-fluid turbulent mixing layers. Whereas previous models have been limited by the assumption of a linear mixing profile, the present paper relaxes this assumption and, as a result, is shown to achieve much better agreement with experimental profiles. Similarity analysis is presented to derive constraints on model coefficients to enforce desired self-similar growth rates that are fully consistent with the high-order spatial profiles. Through this similarity analysis, it is shown that care must be taken in model construction, as it is possible to construct certain terms in such a way as to leave growth rates unconstrained. This model, termed the k-Φ-L-a-V model, is then applied in simulations of Rayleigh-Taylor, Richtmyer-Meshkov, and Kelvin-Helmholtz mixing layers. Overall, these simulations confirm that the expected growth parameters are recovered and high-order spatial profiles are maintained.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Logarithmic profile of temperature in sheared and unstably stratified atmospheric boundary layers

The impact of buoyancy on the mean velocity, temperature, and scalar concentration profiles in the lower atmosphere is typically investigated within the framework of Monin-Obukhov similarity theory (MOST). MOST is the theoretical foundation for parametrizing surface-atmosphere exchanges in nearly all weather, climate, and hydrological models.According to MOST, the classic logarithmic profiles of mean velocity and temperature break down as the buoyancy effects become important. However, recent studies on turbulent Rayleigh-Bénard convection and natural convection along vertical walls suggest that the mean temperature in the near-surface region still follows a logarithmic profile.Motivated by these new results, we study the mean potential temperature profile in sheared and unstably stratified atmospheric boundary layers using direct numerical simulations and field observations. We find that the mean potential temperature profile remains logarithmic across a wide range of stability parameters, which characterizes the relative importance of buoyancy versus shear effects. Compared to MOST, our results suggest that the buoyancy force does not modify the logarithmic nature of the mean potential temperature profile, but instead modulates its slope, which is no longer universal and differs from 1/κ,whereκisthe von Kármán constant. Furthermore, this study provides another perspective on scalar turbulence in the atmospheric boundary layer

58 GEOSCIENCES↗

Main-ion intrinsic toroidal rotation profile driven by residual stress torque from ion temperature gradient turbulence in the DIII-D tokamak

Intrinsic toroidal rotation of the deuterium main ions in the core of the DIII-D tokamak is observed to transition from flat to hollow, forming an off-axis peak, above a threshold level of direct electron heating. Nonlinear gyrokinetic simulations show that the residual stress associated with electrostatic ion temperature gradient turbulence possesses the correct radial location and stress structure to cause the observed hollow rotation profile. Residual stress momentum flux in the gyrokinetic simulations is balanced by turbulent momentum diffusion, with negligible contributions from turbulent pinch. Finally, the prediction of the velocity profile by integrating the momentum balance equation produces a rotation profile that qualitatively and quantitatively agrees with the measured main-ion profile, demonstrating that fluctuation-induced residual stress can drive the observed intrinsic velocity profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Semi-Supervised Disaggregation of Load Profiles at Transmission Buses with Significant Behind-the-Meter Solar Generations

It is of imperative interests for regional transmission organizations (RTOs) to effectively extract daily load profiles at transmission buses, which remains a gap in existing technology paradigm. This digest proposes an explicit yet efficient linear estimator, to disaggregate metered load profiles at buses with significant behind-the-meter (BTM) solar generations in a data driven manner. The proposed estimator is based on utility zonal load profiles and proxy solar irradiance profiles, which in reality is the aggregated waveform at each transmission bus and equivalent to the mix of summed load profiles minus actual BTM solar generation. To overcome technical challenges in the lack of “ground truth” and validate the performance of supervised learning algorithms, we propose semi-supervised mechanisms with parameter tuning, and leverage the unique characteristics of zero-crossing points in BTM solar peaking behaviors.

machine leaning, behind-the-meter, power grid anal↗

Power Profile Monitoring and Tracking Evolution of System-Wide HPC Workloads

The power & energy demands of HPC machines have grown significantly. Modern exascale HPC systems require tens of megawatts of combined power for computing resources and cooling facilities at full capacity. The current energy trend is not sustainable for future HPC systems, and there is a need to work toward the energy efficiency aspect of HPC performance. Energy awareness of the HPC applications at the job level is essential for running an efficient HPC system. This work aims to develop a pipeline to provide a production-level system-wide overview of the HPC workloads' power profile while handling evolving workloads exhibiting new power trends. We developed an open-set classification model for HPC jobs based on the properties of power profiles to continuously provide a system-wide holistic view of recently completed jobs. The pipeline helps continuously monitor the job-level power usage pattern of HPC and enables us to capture the new trends in applications' power behavior. We employed a comprehensive set of techniques to generate job-level data, custom-designed feature extraction methods to extract critical features from jobs' power profiles, clustering techniques powered by generative modeling, and open-set classification for identifying job profiles into known classes or an unknown set. With extensive evaluations, we demonstrate the effectiveness of each component in our pipeline. We provide an analysis of the resulting clusters that characterize the power profile landscape of the Summit supercomputer from more than 60K jobs executed in a year. The open-set classification classifies the known data sets into known classes with high accuracy and identifies unknown data noints with over 85% accuracy.

Karimi, Ahmad Maroof↗

Understanding Measurement Artifacts Causing Inherent Cation Gradients in Depth Profiles of Perovskite Photovoltaics with TOF-SIMS

Time-of-flight secondary-ion mass spectrometry (TOF-SIMS) is one of the few techniques that can obtain chemical information from the hybrid organic-inorganic perovskite solar cells (PSCs) in one dimension (standard depth profiling), two dimensions (high-resolution 100-nm imaging), as well as three dimensions (tomography combining high-resolution imaging with depth profiling). We have very recently developed thermo-mechanical methods to cleave perovskite samples at the back transparent conducting oxide/PSC interface. This allowed for depth-profiling from the back of the device to the front. The resultant profiles answered the lingering question of the apparent A-site cation gradient typically seen in TOF-SIMS depth profiles. In fact, this gradient is a measurement artifact due to beam damage that the community should be informed of as TOF-SIMS data become more commonly employed. Methods of mitigating this artifact by altering the measurement conditions are also presented.

14 SOLAR ENERGY↗

Deep Factorization Machine Learning for Disaggregation of Transmission Load Profiles with High Penetration of Behind-The-Meter Solar

The ever-growing integration of distributed energy resources (DERs), especially behind-the-meter (BTM) solar generations, poses imperative operational challenges to system operators such as regional transmission organizations (RTOs). It is important for RTOs to effectively and accurately extract actual load profiles at the transmission level for a single node with significant BTM solar injection. This paper first illustrates the necessity of disaggregating the daily actual load profile of a single node. Furthermore, by segmenting nodes with selected timeseries features, nodes with significant BTM solar generation are identified. Lastly, a bi-level framework is proposed, comprising reference node disaggregation and DeepFM nodal disaggregation, aimed at disaggregating the nodal load profiles from which system operators require more information. By adopting a hybrid Deep Factorization Machine (DeepFM) model, the model achieve accurate results by extracting both linear and nonlinear relations between nodes in the same region and the zonal load and nodal load profile. To overcome the lack of ground truth, this paper segments the load profile into daytime, nighttime, and zero-crossing points and utilizes the latter two for evaluation purposes. The proposed disaggregation procedure is validated using real world, minute-level, normalized, and anonymized nodal data in the PJM service territory.

42 ENGINEERING↗

Development of Pseudorandom Binary Arrays for Calibration of Surface Profile Metrology Tools

Optical metrology tools, especially for short wavelengths (extreme ultraviolet and x-ray), must cover a wide range of spatial frequencies from the very low, which affects figure, to the important mid-spatial frequencies and the high spatial frequency range, which produces undesirable scattering. A major difficulty in using surface profilometers arises due to the unknown point-spread function (PSF) of the instruments [G. D. Boreman, Modulation Transfer Function in Optical and Electro-Optical Systems (SPIE, Bellingham, WA, 2001)] that is responsible for distortion of the measured surface profile. Generally, the distortion due to the PSF is difficult to account for because the PSF is a complex function that comes to the measurement via the convolution operation, while the measured profile is described with a real function. Accounting for instrumental PSF becomes significantly simpler if the result of measurement of a profile is presented in the spatial frequency domain as a power spectral density (PSD) distribution [J. W. Goodman, Introduction to Fourier Optics, 3rd ed. (Roberts and Company, Englewood, CO, 2005)]. For example, measured PSD distributions provide a closed set of data necessary for three-dimensional calculations of scattering of light by the optical surfaces [E. L. Church et al., Opt. Eng. (Bellingham) 18, 125 (1979); J. C. Stover, Optical Scattering, 2nd ed. (SPIE Optical Engineering Press, Bellingham, WA, 1995)]. The distortion of the surface PSD distribution due to the PSF can be modeled with the modulation transfer function (MTF), which is defined over the spatial frequency bandwidth of the instrument. The measured PSD distribution can be presented as a product of the squared MTF and the ideal PSD distribution inherent for the system under test. Therefore, the instrumental MTF can be evaluated by comparing a measured PSD distribution of a known test surface with the corresponding ideal numerically simulated PSD. The square root of the ratio of the measured and simulated PSD distributions gives the MTF of the instrument. The applicability of the MTF concept to phase map measurements with optical interferometric microscopes needs to be experimentally verified as the optical tool and algorithms may introduce nonlinear artifacts into the process. In previous work [V. V. Yashchuk et al., Proc. SPIE 6704, 670408 (2007); Valeriy V. Yashchuk et al., Opt. Eng. (Bellingham) 47, 073602 (2008)] the instrumental MTF of a surface profiler was precisely measured using reference test surfaces based on binary pseudorandom (BPR) gratings. Here, the authors present results of fabricating and using two-dimensional (2D) BPR arrays that allow for a direct 2D calibration of the instrumental MTF. BPR sequences are widely used in engineering and communication applications such as global position systems and wireless communication protocols. The ideal BPR pattern has a flat 'white noise' response over the entire range of spatial frequencies of interest. The BPR array used here is based on the uniformly redundant array (URA) prescription [E. E. Fenimore and T. M. Cannon, Appl. Opt. 17, 337 (1978)] initially used for x-ray and gamma ray astronomy applications. The URA's superior imaging capability originates from the fact that its cyclical autocorrelation function very closely approximates a delta function, which produces a flat PSD. Three different size BPR array patterns were fabricated by electron beam lithography and induction coupled plasma etching of silicon. The basic size units were 200, 400, and 600 nm. Two different etch processes were used, CF{sub 4}/Ar and HBr, which resulted in undercut and vertical sidewall profiles, respectively. The 2D BPR arrays were used as standard test surfaces for MTF calibration of the MicroMap{trademark}-570 interferometric microscope using all available objectives. The MicroMap{trademark}-570 interferometric microscope uses incoherent illumination from a tungsten filament source and common path modulated phase shifting interference to produce a set of interferograms detected on a change coupled device. Mathematical algorithms applied to the datasets yield the surface phase map. The HBr etched two-dimensional BPR arrays have proven to be a very effective calibration standard making possible direct calibration corrections without the need of additional calculation considerations, while departures from the ideal vertical sidewall require an additional correction term for the CF{sub 4}/Ar etched samples [Samuel K. Barber et al., Abstract to Optics and Photonics 2009: Optical Engineering and Applications Symposium, San Diego, CA, 2-6 August 2009]. Initial surface roughness of low cost 'prime' wafers limits low magnification calibration but should not be a limitation if better polished samples are used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combining dynamic and static depth profiling in low energy ion scattering

The advantages of combining dynamic and static depth profiling in low energy ion scattering are demonstrated for an Si/SiO{sub x}/W/Al{sub 2}O{sub 3} ALD stack. Dynamic depth profiling can be used to calibrate static depth profiling. Energy losses of 152 and 215 eV/nm were found for 3 keV {sup 4}He{sup +} and 5 keV {sup 4}He{sup +} primary ions, respectively, for the experimental configuration used. This is in good agreement with the values used in the field. Static depth profiling can be used to recognize sputter artifacts in dynamic depth profiles.

36 MATERIALS SCIENCE↗

A comparative study of small field total scatter factors and dose profiles using plastic scintillation detectors and other stereotactic dosimeters: The case of the CyberKnife

Purpose: Small-field dosimetry is challenging, and the main limitations of most dosimeters are insufficient spatial resolution, water nonequivalence, and energy dependence. The purpose of this study was to compare plastic scintillation detectors (PSDs) to several commercial stereotactic dosimeters by measuring total scatter factors and dose profiles on a CyberKnife system. Methods: Two PSDs were developed, having sensitive volumes of 0.196 and 0.785 mm{sup 3}, and compared with other detectors. The spectral discrimination method was applied to subtract Cerenkov light from the signal. Both PSDs were compared to four commercial stereotactic dosimeters by measuring total scatter factors, namely, an IBA dosimetry stereotactic field diode (SFD), a PTW 60008 silicon diode, a PTW 60012 silicon diode, and a microLion. The measured total scatter factors were further compared with those of two independent Monte Carlo studies. For the dose profiles, two commercial detectors were used for the comparison, i.e., a PTW 60012 silicon diode and Gafchromics EBT2. Total scatter factors for a CyberKnife system were measured in circular fields with diameters from 5 to 60 mm. Dose profiles were measured for the 5- and 60-mm cones. The measurements were performed in a water tank at a 1.5-cm depth and an 80-cm source-axis distance. Results: The total scatter factors measured using all the detectors agreed within 1% with the Monte Carlo values for cones of 20 mm or greater in diameter. For cones of 10-20 mm in diameter, the PTW 60008 silicon diode was the only dosimeter whose measurements did not agree within 1% with the Monte Carlo values. For smaller fields (<10 mm), each dosimeter type showed different behaviors. The silicon diodes over-responded because of their water nonequivalence; the microLion and 1.0-mm PSD under-responded because of a volume-averaging effect; and the 0.5-mm PSD was the only detector within the uncertainties of the Monte Carlo simulations for all the cones. The PSDs, the PTW 60012 silicon diode, and the Gafchromics EBT2 agreed within 2% and 0.2 mm (gamma evaluation) for the measured dose profiles except in the tail of the 60-mm cone. Conclusions: Silicon diodes can be used to accurately measure small-field dose profiles but not to measure total scatter factors, whereas PSDs can be used to accurately measure both. The authors' measurements show that the use of a 1.0-mm PSD resulted in a negligible volume-averaging effect (under-response of Almost-Equal-To 1%) down to a field size of 5 mm. Therefore, PSDs are strong candidates to become reference radiosurgery detectors for beam characterization and quality assurance measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technical Note: Measurement of bow tie profiles in CT scanners using radiochromic film

Purpose: To provide a noninvasive technique to measure the intensity profile of the fan beam in a computed tomography (CT) scanner that is cost effective and easily implemented without the need to access proprietary scanner information or service modes. Methods: The fabrication of an inexpensive aperture is described, which is used to expose radiochromic film in a rotating CT gantry. A series of exposures is made, each of which is digitized on a personal computer document scanner, and the resulting data set is analyzed to produce a self-consistent calibration of relative radiation exposure. The bow tie profiles were analyzed to determine the precision of the process and were compared to two other measurement techniques, direct measurements from CT gantry detectors and a dynamic dosimeter. Results: The radiochromic film method presented here can measure radiation exposures with a precision of ∼6% root-mean-square relative error. The intensity profiles have a maximum 25% root-mean-square relative error compared with existing techniques. Conclusions: The proposed radiochromic film method for measuring bow tie profiles is an inexpensive (∼$100 USD + film costs), noninvasive method to measure the fan beam intensity profile in CT scanners.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP1-10: Predicting Photon Percentage Depth Dose From Profile Due to Changes in Beam Quality

Purpose: To predict photon percentage depth dose (PDD) from profile due to a change in flattened (FF) and flattening-filter-free (FFF) beam quality. Methods: 6MV photon beam PDDs and profiles in a 3D water tank (3DW) and profiles in an ionization chamber array (ICP) were collected for different field sizes and depths with FF and FFF beams in a Versa HD (Elekta Ltd.). The energy was adjusted by changing the bending magnet current (BMC) ±15% from the clinical beam (6MV) in 5% increments. For baseline establishment, PDDs(depth≥3cm) were parameterized with bi-exponential functions and the PDD 20 to 10cm ratios (PDD{sub 20,10}) were calculated. Then, the FF profile at 10cm from the central axis (Pr{sub 10}) and the slope of the FFF central linear region (SFFF) were calculated. Calibration curves were established: (1) change in Pr{sub 10} and SFFF as functions of the change in PDD{sub 20,10} and (2) change in PDD(depth=3, 15 and 30cm) as function of the change in PDD{sub 20,10}. The differences between Pr{sub 10} and SFFF from baseline were calculated and, from calibration curves, changes in PDD{sub 20,10} and PDD(depth=3, 15 and 30cm) were obtained. Then, absolute PDD(depth=3, 15 and 30cm) values were input into a least-square-optimization algorithm to calculate the bi-exponential function’s optimal coefficients and generate the PDD(depths≥3cm). Results: The change in PDD{sub 20,10} relative to baseline increased (<±4%) with BMC. Pr{sub 10} increased (±6%) and SFFF decreased (±11%) with BMC. Relative differences between measured and calculated (i.e. PDD calculation from Pr{sub 10} and SFFF) PDDs were less than 1%. Results apply to FF and FFF beams measured in 3DW and ICP. Conclusion: Pr{sub 10} and SFFF are more sensitive than PDD to changes in beam energy and PDD information can be accurately generated from them. With known 3DW and ICP profile relationship, ICP can be used to obtain PDD for current photon beam.

61 RADIATION PROTECTION AND DOSIMETRY↗

MO-FG-CAMPUS-IeP2-01: Characterization of Beam Shaping Filters and Photon Spectra From HVL Profiles in CT

Purpose: Advanced dosimetry in CT (e.g. the Monte Carlo method) requires an accurate characterization of the shaped filter and radiation quality used during a scan. The purpose of this work was to develop a method where half value layer (HVL) profiles along shaped filters could be made. From the HVL profiles the beam shaping properties and effective photon spectrum for a particular scan can be inferred. Methods: A measurement rig was developed to allow determinations of the HVL under a scatter-free narrow-beam geometry and constant focal spot to ionization chamber distance for different fan angles. For each fan angle the HVL is obtained by fitting the transmission of radiation through different thicknesses of an Al absorber (type 1100) using an appropriate model. The effective Al thickness of shaped filters and effective photon spectra are estimated using a model of photon emission from a Tungsten anode. This method is used to obtain the effective photon spectra and effective Al thickness of shaped filters for a CT scanner recently introduced to the market. Results: This study resulted in a set of effective photon spectra (central ray) for each kVp along with effective Al thicknesses of the different shaped filters. The effective photon spectra and effective Al thicknesses of shaped filters were used to obtain numerically approximated HVL profiles and compared to measured HVL profiles (mean absolute percentage error = 0.02). The central axis HVL found in the vendor’s technical documentation were compared to approximated HVL values (mean absolute percentage error = 0.03). Conclusion: This work has resulted in a unique method of measuring HVL profiles along shaped filters in CT. Further the effective photon spectra and the effective Al thicknesses of shaped filters that were obtained can be incorporated into Monte Carlo simulations.

61 RADIATION PROTECTION AND DOSIMETRY↗

Algorithms in Diffraction Profile Analysis

This chapter introduces several approaches to crystallographic structure refinement from diffraction profile data including the Rietveld method, global optimization methods, and Bayesian modeling. First, the Rietveld method and related nonlinear least squares approaches to analyzing diffraction profiles are briefly discussed. We then review the most common algorithms within global optimization as alternative methods of structure solution: grid search, simulated annealing, and genetic algorithms. As the Rietveld method is the standard tool for analyzing diffraction profile data, we catalogue its challenges and limitations. A Bayesian approach to diffraction profile analysis is presented as an alternative, along with several sampling algorithms including Gibbs sampling, variants of Metropolis sampling, Hamiltonian Monte Carlo, and approximate Bayesian computing. These sampling algorithms are applied to the fitting of a neutron diffraction profile from a National Institute of Standards and Technology silicon standard reference material, and their results are compared.

Singh, Susheela↗