Search NASA⌕ Search

SEARCH · Search NASA

Results for “PROPELLANT TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32

Design and performance verification of a passive propellant management system

This paper describes the design and verification testing of a reusable passive propellant management system. The system was designed to acquire propellant in low- or zero-g environments and also retain this propellant under high axially directed accelerations that may be experienced during launch and orbit-to-orbit transfer. The system design requirements were established to satisfy generally the requirements for a large number of potential NASA and military applications, such as orbit-to-orbit shuttles and satellite vehicles. The resulting concept was a multicompartmented tank with independent surface tension acquisition channels in each compartment. The tank was designed to provide a minimum expulsion efficiency of 98 percent when subjected to the simultaneous conditions of acceleration, vibration, and outflow. The system design has the unique capability to demonstrate low-g performance in a 1-g test environment, and the test program summarized was structured around this capability.

Hess, D. A.↗

Electromagnetic Pumps for Conductive-Propellant Feed Systems

There has been a recent, renewed interest in high-power electric thrusters for application in nuclear-electric propulsion systems. Two of the most promising thrusters utilize liquid metal propellants: the lithium-fed magnetoplasmadynamic thruster and the bismuth-fed Hall thruster. An important element of part of the maturation of these thrusters will be the development of compact, reliable conductive-propellant feed system components. In the present paper we provide design considerations and experimental calibration data for electromagnetic (EM) pumps. The role of an electromagnetic pump in a liquid metal feed system is to establish a pressure gradient between the propellant reservoir and the thruster - to establish the requisite mass flow rate. While EM pumps have previously been used to a limited extent in nuclear reactor cooling loops, they have never been implemented in electric propulsion (EP) systems. The potential benefit of using EM pumps for EP are reliability (no moving parts) and the ability to precisely meter the propellant flow rate. We have constructed and tested EM pumps that use gallium, lithium, and bismuth propellants. Design details, test results (pressure developed versus current), and material compatibility issues are reported. It is concluded that EM pumps are a viable technology for application in both laboratory and flight EP conductive-propellant feed systems.

Markusic, T. E.↗

Propulsion System Development for the Iodine Satellite (iSAT) Demonstration Mission

The development and testing of a 200-W iodine-fed Hall thruster propulsion system that will be flown on a 12-U CubeSat is described. The switch in propellant from more traditional xenon gas to solid iodine yields the advantage of high density, low pressure propellant storage but introduces new requirements that must be addressed in the design and operation of the propulsion system. The thruster materials have been modified from a previously-flown xenon Hall thruster to make it compatible with iodine vapor. The cathode incorporated into this design additionally requires little or no heating to initiate the discharge, reducing the power needed to start the thruster. The feed system produces iodine vapor in the propellant reservoir through sublimation and then controls the flow to the anode and cathode of the thruster using a pair of proportional flow control valves. The propellant feeding process is controlled by the power processing unit, with feedback control on the anode flow rate provided through a measure of the thruster discharge current. Thermal modeling indicates that it may be difficult to sufficiently heat the iodine if it loses contact with the propellant reservoir walls, serving to motivate future testing of that scenario to verify the modeling result and develop potential mitigation strategies. Preliminary, short-duration materials testing has thus-far indicated that several materials may be acceptable for prolonged contact with iodine vapor, motivating longer-duration testing. A propellant loading procedure is presented that aims to minimize the contaminants in the feed system and propellant reservoir. Finally, an 80-hour duration test being performed to gain experience operating the thruster over long durations and multiple restarts is discussed.

Polzin, Kurt A.↗

Low and high speed propellers for general aviation - Performance potential and recent wind tunnel test results

A survey is presented of current research efforts in general aviation, low-speed propeller design and high-speed propfan design, with attention on such features as (1) advanced blade shapes, with novel airfoils and sweep, (2) tip devices, (3) integrated propeller/nacelle designs, (4) area-ruled spinners, (5) lightweight, all-composite blade construction, and (6) contra-rotating propfan systems. The potential overall improvements associated with these design modifications are calculated to lie at 10-15% for low-speed rotors and 15-30% for high-speed ones. Emphasis is placed on noise reduction, blade drag, performance prediction methods and wind tunnel testing of alternative rotor configurations. Extensive use of graphs is made in performance comparisons between alternative blade and rotor designs.

Jeracki, R. J.↗

The effects of various cure cycles upon the viability of Bacillus subtillis var. niger spores within solid propellant.

Saturethane solid propellant was used in all tests. The spore inoculum was evenly distributed in the propellant. Samples weighing approximately 5 g were aseptically removed, placed into curing ovens, and exposed to cure temperatures. Initial tests were conducted at 82 and 93 C. Analysis of the obtained data indicated that the survivor curves were not linear. Exposure of the inoculated propellant samples to 93 C reduced the initial population to less than 0.01% in about 20 hours. At 82 C, approximately 168 hours were required for a similar reduction. Tests involving curing temperatures of 105 and 115 C were also conducted. It is pointed out that changes in the mechanism of spore inactivation due to chemical and physical changes in the propellant could account for the nonlinear survivor curves obtained.

Brewer, W. A.↗

LOX/Methane Main Engine Igniter Tests and Modeling

The LOX/methane propellant combination is being considered for the Lunar Surface Access Module ascent main engine propulsion system. The proposed switch from the hypergolic propellants used in the Apollo lunar ascent engine to LOX/methane propellants requires the development of igniters capable of highly reliable performance in a lunar surface environment. An ignition test program was conducted that used an in-house designed LOX/methane spark torch igniter. The testing occurred in Cell 21 of the Research Combustion Laboratory to utilize its altitude capability to simulate a space vacuum environment. Approximately 750 ignition test were performed to evaluate the effects of methane purity, igniter body temperature, spark energy level and frequency, mixture ratio, flowrate, and igniter geometry on the ability to obtain successful ignitions. Ignitions were obtained down to an igniter body temperature of approximately 260 R with a 10 torr back-pressure. The data obtained is also being used to anchor a CFD based igniter model.

Breisacher, Kevin J.↗

Design and Testing of Demonstration Unit for Maintaining Zero Cryogenic Propellant Boiloff

Launching of cryogenic propellants into earth orbit and beyond is very expensive. Each additional pound of payload delivered to low earth orbit requires approximately 35 pounds of additional weight at liftoff. There is therefore a critical need to minimize boiloff in spacecraft long term missions/systems. Various methods have been used to date, including superinsulation and thermodynamic vents to reduce boiloff. A system was designed and tested as described herein that will totally eliminate boiloff. This system is based on a closed-loop, two-stage pulse tube refrigerator with a net refrigeration of four watts at 15k for the recovery of hydrogen propellant. It is designed to operate at 30 Hz which is an order of magnitude higher than other typical pulse tube refrigerators. This high frequency allows the use of a much smaller, lighter weight compressor, This paper describes the system design, fabrication and test results.

Dean, W. G.↗

A 2000-hour cyclic endurance test of a laboratory model multipropellant resistojet

The technological readiness of a long-life multipropellant resistojet for space station auxiliary propulsion is demonstrated. A laboratory model resistojet made from grain-stabilized platinum served as a test bed to evaluate the design characteristics, fabrication methods, and operating strategies for an engineering model multipropellant resistojet developed under contract by the Rocketdyne Division of Rockwell International and Technion Incorporated. The laboratory model thruster was subjected to a 2000-hr, 2400-thermal-cycle endurance test using carbon dioxide propellant. Maximum thruster temperatures were approximately 1400 C. The post-test analyses of the laboratory model thruster included an investigation of component microstructures. Significant observations from the laboratory model thruster are discussed as they relate to the design of the engineering model thruster.

Morren, W. Earl↗

2000-hour cyclic endurance test of a laboratory model multipropellant resistojet

The technological readiness of a long-life multipropellant resistojet for space station auxiliary propulsion is demonstrated. A laboratory model resistojet made from grain-stabilized platinum served as a test bed to evaluate the design characteristics, fabrication methods, and operating strategies for an engineering model multipropellant resistojet developed under contract by the Rocketdyne Division of Rockwell International and Technion Incorporated. The laboratory model thruster was subjected to a 2000-hr, 2400-thermal-cycle endurance test using carbon dioxide propellant. Maximum thruster temperatures were approximately 1400 C. The post-test analyses of the laboratory model thruster included an investigation of component microstructures. Significant observations from the laboratory model thruster are discussed as they relate to the design of the engineering model thruster.

Morren, W. Earl↗

Advanced launch system Component Test Facility

Upgrading of existing test facilities required for development of liquid fuel rocket engines for advanced launch systems is discussed. The Component Test Facility (CTF) for testing generators and turbopumps assemblies of the future engine is presented with emphasis on design criteria, design, test frequency, test duration, safety, and operational issues of the cryogenic propellant and high-pressure gas systems. Attention is also given to methods of controlling propellant temperatures and flows to the test components; pressurization of propellants accomplished with high-pressure hydrogen and nitrogen gases; and use of high-pressure pumps and vaporizers, which convert liquid nitrogen and hydrogen to gases at pressures up to 15,000 psig.

Pitalo, Gerald A.↗

Qualitative Results from a Flight Investigation to Determine Aileron Effectiveness of Two Rocket-Propelled 1/20-Scale Models of the MX -76 Missile

Free-flight tests of two rocket-propelled l/20-scale models of the Bell MX-776 missile have been conducted to obtain measurements of the aileron deflection required to counteract the induced rolling moments caused by combined angles of attack and sideslip and thus to determine whether the ailerons provided were capable of controlling the model at the attitudes produced by the test conditions. Inability to obtain reasonably steady-state conditions and superimposed high-frequency oscillations in the data precluded any detailed analysis of the results obtained from the tests. For these reasons, the data presented are limited largely to qualitative results.

Stevens, Joseph E.↗

Long-term storage test of a Syncom solid rocket motor

After 7.5 years of storage at ambient temperature, a solid propellant apogee motor was tested successfully. The performance of the motor did not deteriorate as a result of prolonged storage. Tabular performance data and graphic thrust and pressure variations are given.

Ray, R. L.↗