Search NASA⌕ Search

SEARCH · Search NASA

Results for “PV variability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

561 records · Page 32

High-Temperature Linear Receiver Enabled by Multicomponent Aerogels

Concentrating solar thermal (CST) technology has significant potential mainly due to its dispatchability and low cost of storage. However, to compete with other sources, including utility-scale solar PV, its final cost (cents/kWh) still needs to be lowered. Cost reduction can be achieved by improving the system level efficiency of the CST plants through the deployment of advanced power cycles, which operate at high temperatures of ~700°C. However, optical, and thermal losses pose a major challenge to the efficiency of such CST systems. The overall aim of this project is to investigate and de-risk a linear solar receiver concept called an Aerogel Insulated Receiver (AIR) that generates high temperatures (up to 700°C) at a low solar concentration ratio (<100) and with a high collection efficiency (optical × receiver). Our prior work has demonstrated the thermal stability1 and optical and heat-insulating properties2,3 of transparent aerogel insulation at a one-inch scale. The focus of this work is on (1) co-optimization of the geometry of the aerogel tile and receiver enclosure to fit a standard parabolic collector (PTC), (2) scale-up of aerogels into 4-inch tiles while preserving key properties, (3) experimental measurement of receiver heat loss (W/m) in a >70-cm test stand and validation of anticipated receiver performance at high temperatures. Regarding (1), appropriate optical and thermal models for a parabolic trough receiver (PTR) are developed and validated. The geometry of the aerogels and the receiver enclosure are co-optimized to maximize the collection efficiency. The model predicts a 54% collection efficiency at 700°C for an AIR design based on flat aerogels. By combining the collection efficiency with the power block efficiency of supercritical CO 2 cycles, we predict >10% improvements in peak plant efficiency relative to existing line-focusing CST systems. The application of curved plasmonic aerogels is predicted to further increase the collection efficiency to 64%. Regarding (2), we demonstrate the successful development of 6-inch-long refractory aerogel tiles with optical, thermal, and stability characteristics consistent with our prior work. This scale-up requires a transition to a larger ALD station and modifying the ALD process variables such as exposure time and the number of precursor doses. Regarding (3), we design and develop an AIR test stand measuring 3 feet in length. Heat loss performance analysis is carried out using the test stand. The results indicate that aerogel insulation can significantly reduce receiver thermal losses at the high operating temperatures required for next-generation PTRs. The experimental results agree with the heat loss performance predicted by our receiver model. Lastly, we conducted preliminary failure mode and effects (FMEA) and techno-economic (TEA) analyses to identify failure mitigation strategies and commercial opportunities, respectively. Overall, this project identifies key opportunities and challenges in deploying aerogel insulating receivers in next-generation line-focusing CST technologies.

14 SOLAR ENERGY↗

Drivers of the Resource Adequacy Contribution of Solar and Storage for Florida Municipal Utilities

Solar’s variable generation limits its contribution to reliably meeting peak demand, or its resource adequacy contribution. Energy storage is a leading option to increase solar’s resource adequacy contribution, yet the contribution from different configurations of solar and storage is not widely understood. We develop methods for exploring the primary drivers of an estimate of the resource adequacy contribution of solar and storage, and we apply the methods to a case study in Florida, where demand peaks in winter and summer. We find that the portion of solar nameplate capacity that contributes to resource adequacy—its capacity credit—is less than 50% and that it declines with increasing solar penetration. The capacity credit of storage, even though it is fully controllable by the system operator, strongly depends on the duration of storage. The capacity credit of 1 hour of storage can be less than the capacity credit of solar. Achieving a 90% capacity credit requires at least 4–5 hours of storage when storage capacity is small relative to the system peak. As storage deployment increases to 20% of the peak demand, 9 hours—and sometimes more than 10 hours—of storage are needed to achieve a 90% capacity credit. Increased solar deployment at the system level can increase storage’s capacity credit. Directly pairing solar and storage can also impact the capacity credit. Storage with a power rating similar to the solar inverter rating loses capacity credit when coupled with solar if its duration is more than 1–2 hours, because storage competes with solar for use of the inverter. On the other hand, there is no reduction in capacity credit when the storage is small relative to the solar inverter. The approach and tools developed here for exploratory analysis can be useful for many other utilities and regions grappling with similar preliminary questions, prior to evaluation of specific cases using more detailed and resource-intensive modeling.

14 SOLAR ENERGY↗

Packages of Distributed Energy Technologies Demonstrating Demand Flexibility at Community Scale

The combination of increased electric load growth across all sectors, deferred electrical infrastructure investment, and other factors resulting in variable electric power supply, has created technical challenges to maintaining a resilient and reliable grid. Many federal, regional, and local efforts are in play to modernize the electric grid, including advancing building technologies and distributed energy resources (DERs) that are utilizing smarter controls to become responsive to both occupant and grid needs. This report reviews ten pilot projects demonstrating how groups of buildings combined with behind-the-meter (BTM) DERs such as electric vehicle (EV) charging, battery storage, flexible HVAC and domestic hot water systems, and photovoltaic systems can reliably and cost effectively provide grid services. Each of the ten pilot projects aim to deliver both energy efficiency and demand flexibility (DF) while supporting load growth. The ten demonstration teams are piloting flexible DER packages across diverse communities of residential and commercial buildings to address a variety of regional grid needs. The outcomes of these pilot projects will be used to inform future scaling through utility program development. This paper characterizes the ten teams, showcasing the decision-making process used by each group to develop their packages (Section 2), the grid services they plan to deliver (Section 3), the types of DER packages selected for deployment within building sectors (Section 4) and trends between building sector, DER types, and grid services In order to achieve community scale benefits, the pilot projects must utilize aggregated control mechanisms for coordinating buildings and DERs together. Several types of coordinated control architectures have evolved amongst the teams, influenced by use type, existing market conditions, and integration type. Three coordinated controls architectures have been characterized, highlighting their use cases, benefits, challenges, and tradeoffs in their design. These insights can aid utilities, control vendors, and developers in scaling community-level energy systems (Paul, 2024). Ultimately, the technology packages selected by the ten teams will be coordinated to provide power system services, also known as grid services. Insights from these demonstrations will be useful for grid operators, regulators, aggregators and other stakeholders as they look to deploy demand flexible resources as grid services in the future. The grid services that each team is targeting for demonstration are described in Section 3 and Section 4. Methods for evaluating the grid services have been described in the paper Metrics for Evaluating Grid Service Provision from Communities of Grid-interactive and Efficient Buildings and other DER (MacDonald, 2023). To identify technology packages for demonstration, Section 2 shows that project teams used a range of analysis approaches, including building energy modeling, AMI data analysis, cost-benefit frameworks, and utility pilot data. Some teams emphasized technical modeling to quantify grid impacts and demand reduction potential, while others prioritized economic evaluations, stakeholder input, or exploratory pilots to inform deployment decisions. This diversity reflects the need to tailor selection methods to project goals, available data, and organizational context. Section 5 discusses trends between the DER technologies deployed and the grid service provisions from each team. Residential buildings (multifamily and single family) lean towards technologies that enhance energy efficiency (e.g. weatherization upgrades, smart thermostats) and onsite power generation integration (e.g. solar PV). Commercial building demonstrations prioritize technologies that ensure operational reliability (e.g. battery storage) and centralized energy management systems and optimization solutions. Teams that are deploying controllable storage-based technologies are more likely to provide grid services that require a near real-time response. Teams incorporating load shifting technologies like smart thermostats with HEMs are likely to include energy markets participation and customer bill management offerings. Campus demonstrations are adopting diverse sets of DERs to emphasize renewable generation, paired with centralized control. This section also describes technologies that were considered during project planning but ultimately excluded from final deployment. These demonstrations reveal that effective DER package design should be tailored to building type, customer segment, and construction vintage. Multifamily buildings benefit from centralized HVAC upgrades and supervisory controls, while single-family homes are well-suited for individualized technologies like solar, storage, and smart home energy monitors. Commercial and campus settings prioritize EMIS integration and load optimization. New construction enables cost-effective integration of DER-ready infrastructure, whereas retrofits require deployments aligned with owner and tenant value streams. For utility program planners, early coordination with developers and building owners, paired with segmented and modular program offerings, can improve adoption, scalability, and grid impact.

24 POWER TRANSMISSION AND DISTRIBUTION↗