Simulation of the supercritical CO 2 recompression Brayton power cycle with a high-temperature regenerator

The supercritical carbon dioxide (sCO 2 ) recompression Brayton cycle promises higher efficiency and lower capital cost than traditional steam Rankine power cycles. However, achieving high efficiency requires large, highly effective recuperators. Regenerators may be a low-cost alternative to printed circuit and micro-tube heat exchangers for recuperation in sCO 2 power cycles. Regenerators are a periodic heat exchanger in which thermal energy is extracted from the hot stream, stored in solid media, and then released to the cold stream at a later time. Fixed bed regenerators with valves to direct fluid are the preferred method for implementing regenerators in power cycles, but the inherently transient nature of these systems has not been characterized for this application. This study presents the simulation of a high-temperature regenerator within a 10 MWe sCO 2 recompression Brayton cycle. A transient, one-dimensional regenerator model presented in a previous study is used to simulate the regenerator. Dynamic heat exchanger models are also developed for the precooler, low-temperature recuperator, and primary heat exchanger, and the compressors and the turbine are modeled with off-design performance maps. We assess two regenerator-valve design options; one for fast switching, and one for reduced flow rate fluctuations. System simulation finds that both designs see significant fluctuations in turbomachinery flow rate, turbomachinery and system power, and regenerator discharge process outlet temperature. While designing the regenerator-valve subsystem for lower fluctuations is possible, the regenerator cold discharge temperature and net power still fluctuate by ±77.6°C and 6%, respectively. Increasing buffer volume is not effective at sufficiently reducing these fluctuations, but adding a packed bed in between the regenerator and the primary heat exchanger can reduce regenerator discharge process outlet temperature fluctuations to 6.4°C. Further reductions could be possible by increasing the size of this packed bed.

42 ENGINEERING↗

Start-up and Emergency Shutdown Modeling for a Coal-fired 10MWe sCO₂ Power Plant

As part of a Phase II Front End Engineering Design (FEED) study for the DOE Fossil Fuel Large Scale Pilots program, investigations of novel start-up and emergency shutdown methods for a stoker-fed, coal-fired, 10MWe sCO₂ power plant proposal were performed. These investigations were performed using 1D transient system models of the plant created within the GT-SUITE system modeling platform. The system model components were created using vendor quotation data (heat exchangers), performance maps (turbomachines), or FMU models (fired heater). Previously, Echogen Power Systems (Echogen) has used a sCO₂ power cycle start-up method that fills the system with liquid CO₂ to facilitate easy use of an electrically-driven start pump to transition the system from initial CO₂ fill to turbo-compressor initialization. The novel start-up method presented attempts this transition with a minimal filling of the system with liquid CO₂, to reduce the total CO₂ inventory required. This method leaves the start pump vulnerable to a two phase inlet condition as system pressure is below the CO₂ saturation pressure for the condenser cooling water temperature (Tcw). System model cases at Tcw of 18°C, 26°C, and 32°C, corresponding to cold, design, and hot ambient days, were analyzed to determine if the SP inlet condition could be kept as a subcooled liquid and estimate the CO₂ inventory reduction amount./p> Stoker-fed, coal-fired heaters continue to emit heat for some time even after emergency shutdown from events such as a power failure. This heat emission would lead to a failure of the fired heater, as the metal overheats, if the CO₂ flow is shut off. The emergency shutdown method presented utilizes CO₂ vented by a controllable vent valve (CRV) to provide CO₂ cooling flow to the fired heater. To determine the effectiveness of this method at keeping the fired heater peak tubing metal temperature below the ASME material temperature limit, for pressures below 5 MPa, of 816 °C, system model cases with CRV diameters ranging from 4” to 10”, and an alternative CO₂ vent routing with CRV size of 6”, were investigated./p>

01 COAL, LIGNITE, AND PEAT↗

Benchmark Specification for FFTF LOFWOS Test #13

The Fast Flux Test Facility (FFTF) at the Hanford site in Washington was designed by the Westinghouse Electric Corporation for the U.S. Department of Energy. FFTF was a 400 MW thermal, oxide-fueled, liquid sodium cooled test reactor, built to assist development and testing of advanced fuels and materials for fast breeder reactors. After reaching criticality in 1980, FFTF operated until 1992, providing the U.S. Department of Energy (DOE) with the means to test fuels, materials, and other components in a fast neutron flux environment. In July 1986, a series of unprotected transients (with the plant protection system intentionally disabled) were performed in FFTF as part of the passive safety demonstration program. Among these were thirteen loss of flow without scram (LOFWOS) tests. The goals of this program included confirming the liquid metal reactor safety margins, providing data for computer code validation, and demonstrating the inherent and passive safety benefits of specific design features. The test defined in this benchmark is LOFWOS Test #13, which was initiated at 50% power and 100% flow with the pump pony motors turned off. This benchmark specification is intended to support collaborative efforts within international partnerships on the validation of simulation tools and models in the area of Sodium-cooled Fast Reactor (SFR) safety. Validated tools and models are needed to evaluate SFR inherent safety characteristics and assess the impact of passive design features in response to accident initiators. Comparisons with experimental data and the results of safety analyses from other groups create unique opportunities to improve predictive capabilities of computational codes and methods for SFR modeling and simulation. The conditions of the LOFWOS test along with the feedback from FFTF’s limited free bow core restraint system and the novel passive reactivity control Gas-Expansion Modules (GEMs) pose a very challenging and uniquely valuable benchmark exercise.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The revised FLORIDyn model: implementation of heterogeneous flow and the Gaussian wake

In this paper, a new version of the FLOw Redirection and Induction Dynamics (FLORIDyn) model is presented. The new model uses the three-dimensional parametric Gaussian FLORIS model and can provide dynamic wind farm simulations at a low computational cost under heterogeneous and changing wind conditions. Both FLORIS and FLORIDyn are parametric models which can be used to simulate wind farms, evaluate controller performance and can serve as a control-oriented model. One central element in which they differ is in their representation of flow dynamics: FLORIS neglects these and provides a computationally very cheap approximation of the mean wind farm flow. FLORIDyn defines a framework which utilizes this low computational cost of FLORIS to simulate basic wake dynamics. This is achieved by creating so-called observation points (OPs) at each time step at the rotor plane which inherit the turbine state. In this work, we develop the initial FLORIDyn framework further considering multiple aspects. The underlying FLORIS wake model is replaced by a Gaussian wake model. The distribution and characteristics of the OPs are adapted to account for the new parametric model but also to take complex flow conditions into account. To achieve this, a mathematical approach is developed to combine the parametric model and the changing, heterogeneous world conditions and link them with each OP. We also present a computationally lightweight wind field model to allow for a simulation environment in which heterogeneous flow conditions are possible. FLORIDyn is compared to Simulator for Offshore Wind Farm Applications (SOWFA) simulations in three- and nine-turbine cases under static and changing environmental conditions. The results show a good agreement with the timing of the impact of upstream state changes on downstream turbines. They also show a good agreement in terms of how wakes are displaced by wind direction changes and when the resulting velocity deficit is experienced by downstream turbines. A good fit of the mean generated power is ensured by the underlying FLORIS model. In the three-turbine case, FLORIDyn simulates 4 s simulation time in 24.49 ms computational time. The resulting new FLORIDyn model proves to be a computationally attractive and capable tool for model-based dynamic wind farm control.

17 WIND ENERGY↗

A vortex sheet based analytical model of the curled wake behind yawed wind turbines

Motivated by the need for compact descriptions of the evolution of non-classical wakes behind yawed wind turbines, we develop an analytical model to predict the shape of curled wakes. Interest in such modelling arises due to the potential of wake steering as a strategy for mitigating power reduction and unsteady loading of downstream turbines in wind farms. We first estimate the distribution of the shed vorticity at the wake edge due to both yaw offset and rotating blades. By considering the wake edge as an ideally thin vortex sheet, we describe its evolution in time moving with the flow. Vortex sheet equations are solved using a power series expansion method, and an approximate solution for the wake shape is obtained. The vortex sheet time evolution is then mapped into a spatial evolution by using a convection velocity. Apart from the wake shape, the lateral deflection of the wake including ground effects is modelled. Our results show that there exists a universal solution for the shape of curled wakes if suitable dimensionless variables are employed. For the case of turbulent boundary layer inflow, the decay of vortex sheet circulation due to turbulent diffusion is included. Finally, we modify the Gaussian wake model by incorporating the predicted shape and deflection of the curled wake, so that we can calculate the wake profiles behind yawed turbines. Model predictions are validated against large-eddy simulations and laboratory experiments for turbines with various operating conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Motorette Thermal Performance Testing and Modeling for an Electric Motor with Additively Manufactured Hollow Conductors with Integrated Heat Pipes

This paper discusses the design, build and test of a motorette to characterize the thermal performance of an additively manufactured coil integrated with heat pipes. The motorette is powered using a variable frequency AC power supply and cooled through two independent cooling systems. The first cooling system cools the stator core using forced convection of air flowing over a finned heat sink mounted on the stator outer diameter. The second cooling system cools the heat pipes using forced convection of 50-50 water ethylene glycol (WEG) mixture flowing through condenser chambers. A 3D thermal FEA model of the setup is built and heat transfer coefficients (HTC) of convective boundaries are computed using coolant flow rates from test data and empirical equations. Temperature at locations on the coil and heat sink are recorded and compared to thermal model predicted values. A maximum temperature error of 22.7% occurs at 180ARMS and 800 Hz operating point for the AM dual coil. The thermal model provides higher temperatures compared to test results and hence it is on the conservative side but in general, there is good correlation between test and model results. Lastly, opportunities for improvement to both test data measurement and 3D thermal FEA modeling are discussed.

additive manufacturing↗

Conjugate Heat Transfer Modeling of Salt-Filled Fuel Pins for Stable Salt Reactor Safety Analysis

The Stable Salt Reactor (SSR) combines the proven structural design of light water reactor fuel assemblies with the inherent safety and fuel-cycle advantages of molten salt technology. In its fast reactor configuration, the SSR utilizes recycled nuclear waste as fuel, sealed within narrow salt-filled fuel pins and cooled by a surrounding liquid salt coolant. Reliable transfer of heat from the molten fuel salt through the cladding to the external coolant is essential for both reactor safety and performance. This work investigates conjugate heat transfer (CHT) in the SSR’s salt-filled fuel pins using NekRS, a high-fidelity spectral element computational fluid dynamics (CFD) solver. The analyses capture internal natural convection within the molten fuel salt and external forced convection in the coolant, under steady-state and transient operating conditions. Parametric studies evaluate how variations in reactor power and coolant flow rate influence heat transfer distributions and system response. The high-fidelity CFD results are time-averaged and post-processed for direct comparison with moderate-fidelity Reynolds-averaged Navier–Stokes (RANS) models, and for the development of reduced-order models within the SAM system code. These validated models support fast-running safety analyses of normal and off-normal transients, improving predictive capability for key safety margins. By integrating advanced CFD with system-level safety tools, this study strengthens the modeling framework for SSR design, reduces uncertainty in molten salt CHT simulations, and accelerates the engineering and licensing of next-generation nuclear reactors.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Computational modelling and experimental tank testing of the multi float WaveSub under regular wave forcing

A submerged wave device generates energy from the relative motion of floating bodies. In WaveSub, three floats are joined to a reactor; each connected to a spring and generator. Electricity generated damps the orbital movements of the floats. The forces are non-linear and each float interacts with the others. Tuning to the wave climate is achieved by changing the line lengths, so there is a need to understand the performance trade-offs for a large number of configurations. This requires an efficient, large displacement, multidirectional, multi-body numerical scheme. Results from a 1/25 scale wave basin experiment are described. Here, we show that a time domain linear potential flow formulation (Nemoh, WEC-Sim) can match the tank testing provided that suitably tuned drag coefficients are employed. Inviscid linear potential models can match some wave device experiments; however, additional viscous terms generally provide better accuracy. Scale experiments are also prone to mechanical friction, and we estimate friction terms to improve the correlation further. The resulting error in mean power between numerical and physical models is approximately 10%. Predicted device movement shows a good match. Overall, drag terms in time domain wave energy modelling will improve simulation accuracy in wave renewable energy device design. to understand the performance trade-offs for a large number of configurations. This requires an efficient, large displacement, multidirectional, multi-body numerical scheme. Results from a 1/25 scale wave basin experiment are described. Here, we show that a time domain linear potential flow formulation (Nemoh, WEC-Sim) can match the tank testing provided that suitably tuned drag coefficients are employed. Inviscid linear potential models can match some wave device experiments; however, additional viscous terms generally provide better accuracy. Scale experiments are also prone to mechanical friction, and we estimate friction terms to improve the correlation further. The resulting error in mean power between numerical and physical models is approximately 10%. Predicted device movement shows a good match. Overall, drag terms in time domain wave energy modelling will improve simulation accuracy in wave renewable energy device design.

16 TIDAL AND WAVE POWER↗

FY22 Status Report on the ART-GCR CMVB and CNWG International Collaborations

This work presents the numerical model for the high temperature test reactor (HTTR) loss of forced cooling (LOFC) experiment with the INL codes Griffin, BISON, and RELAP-7, based on the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework. Promising results were obtained, with the overall behavior of the reactor successfully captured. Changes in the heat transfer coupling, as compared to the fiscal year (FY)-21 model, enabled drastic improvement of the steady-state solution, both in terms of computational time and global energy discrepancies. The former was reduced by a factor of roughly 60, whereas the latter decreased from 11% to less than 2%. Furthermore, the discrepancy in the steady-state multiplication factor was improved from +2,300 and +2,900 pcm (for the 30 and 9 MW cases) to -700 and +1,200 pcm, respectively, and now falls well within the large measurement uncertainties stemming from graphite impurities. Validation of the Monte Carlo model used to generate cross sections was also performed against available measurements. Though significant, the discrepancies remain acceptable overall in light of the large uncertainty. Numerous improvements are still needed to better compare with the experiment involving the 9 MW case and to instill greater confidence in the model’s ability to accurately predict the 30 MW behavior. Specifically, the power levels predicted by the 9 MW transient simulation following re-criticality remain low, pointing to an underestimation of the passive cooling of the core. A key aspect of future work will be to better understand the flow pattern during the LOFC event, particularly to determine if natural or forced convection is occurring inside the reactor pressure vessel (RPV). More generally, additional validation data would be immensely useful for further enhancing the numerical model and better matching the experiments. In addition, a more sophisticated thermal-hydraulics model that simulates all the channels as a single system model should be considered to take into account the rest of the primary loop. Finally, even if the results are in better agreement with the experiments, sensitivity analysis and uncertainty quantification will be necessary to evaluate the model uncertainty.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Printed circuit primary heat exchanger for power conversion in heat pipe microreactor applications

Here, in the present study, a model was developed for a recuperated air Brayton cycle for heat pipe microreactors, and the effect of the primary heat exchanger type assessed. An annular flow heat exchanger and a printed circuit heat exchanger (PCHE) were evaluated. A sub-sized diffusion bonded, PCHE test specimen was manufactured and tested with nitrogen as the working fluid to validate and improve the PCHE model. A comparison of the thermal cycle efficiency for the Brayton cycle coupled to a heat pipe microreactor using each of the two primary heat exchangers showed competitive performance for both options, with achievable cycle efficiencies of 34 % and 35 % for the annular and printed circuit heat exchangers, respectively. The impact of heat pipe length and additional reheating stages on cycle efficiency was studied. Increasing the heat pipe condenser length from 0.8 to 2.0 m resulted in an increase in cycle efficiency of 3.5 % and 3.2 % for the annular and printed circuit heat exchangers, respectively. The use of additional reheating stages showed a reduction in cycle efficiency since the heat pipe surface area limits the primary heat exchanger size and effectiveness. These results highlight the importance of the primary heat exchanger on the performance of a heat pipe microreactor. Overall, the cycle model, testing, and heat exchanger model showed the potential for the PCHE to improve the economics of a heat pipe microreactor relative to the annular flow heat exchanger, which also opens the possibility to use different heat transfer fluids such as supercritical CO 2 .

PCHE↗

Effect of net direct current on the properties of radio frequency sheaths: simulation and cross-code comparison

In order to understand, predict and control ion cyclotron range of frequency (ICRF) interactions with tokamak scrape-off layer plasmas, computational tools which can model radio frequency (RF) sheaths are needed. In particular, models for the effective surface impedance and DC rectified sheath potentials may be coupled with full wave RF simulation codes to predict self-consistent wave fields near surfaces and the resulting power dissipation and plasma-material interactions from ion sputtering. In this study, previous work assuming zero net DC current flow through the sheath is generalized to allow the surface to collect net positive or negative current, as is often observed in experiments. The waveforms, DC potential and RF admittance are investigated by means of analytical theory, nonlinear fluid and particle-in-cell (PIC) codes. Cross-code comparisons provide detailed model verification and elucidate the roles of ion and electron kinetics. When the sheath draws negative (positive) DC current, the voltage rectification is reduced (increased) compared with the zero-current case, and the magnitude of both the real and imaginary parts of the admittance are increased (reduced). In conclusion, a previous four-input parametrization of the sheath rectification and admittance properties is generalized to include a fifth parameter describing the DC sheath current.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of carbon incorporation in laser-assisted MOCVD of GaN

Background carbon (C) impurity incorporation in metalorganic chemical vapor deposition (MOCVD) grown gallium nitride (GaN) represents one of the major issues in further improving GaN vertical power device performance. This work presents a laser-assisted MOCVD (LA-MOCVD) technique to address the high-C issue in MOCVD homoepitaxial GaN under different growth rate (Rg) regimes and studies the correlations between [C] and Rg. [C] in LA-MOCVD GaN is reduced by 50%–90% as compared to the conventional MOCVD GaN for a wide growth rate range between 1 and 16 μm/h. A mass-transport based model is developed to understand the C incorporation at different Rg regimes. The results obtained from the developed model are in good agreement with experimental data. The model further reveals that LA-MOCVD effectively suppresses C incorporation by reducing the active C species in the gas phase. Moreover, high step velocity in step flow growth mode can facilitate C incorporation at fast Rg, exhibiting steeper C increase. The theoretical model indicates that [C] can be suppressed below 1016 cm−3 with a fast growth rate (Rg) of 10 μm/h by utilizing higher power LA-MOCVD and freestanding GaN substrates with larger off-cut angles.

Physics↗

FY22 Progress on Computational Modeling of the Water-Based NSTF

This report summarizes the system-level modeling effort by Argonne National Laboratory (Argonne) of the Natural convection Shutdown heat removal Test Facility (NSTF) in FY22. As an extension of the effort from FY21, this year’s work focuses primarily on the two-phase modeling of the NSTF using RELAP5-3D, particularly with the inclusion of the cavity model. The results from simulations were used to compare against experimental data for benchmarking purposes of the RELAP5 deck. Additionally, RELAP5 was used as a predictive tool to guide planned test operations and identify expected system behaviors. In the first part of this report, details are provided of the cavity omitted model where heat flux is applied directly as a boundary condition to the risers. The general trend predicted by the RELAP5 model matches that from the experimental data when a single-phase natural circulation flow is first established, followed by an oscillatory two-phase period and finally a stable two-phase flow. However, the onset of oscillations is predicted early by the model due to the smaller thermal mixing region in the tank. However, by expanding the simulated thermal mixing region in the tank, the onset of oscillations predicted by the model is able to match that from the experiment. These oscillations where studied in depth and are deduced to be flashing-induced instability. The model was then modified to simulate an accident scenario case where a representative heat load based on the full-scale Framatome’s 625 MW t SC-HTGR was applied directly to the riser channels. The simulated initial and boundary conditions were identical to those performed experimentally, facilitating direct comparisons between the predicted and experimental results. It was determined that the results showed some discrepancies remain, likely due to the overprediction of vapor generation rate by the computer model. In the second part of this report, the cavity model is re-introduced where it is observed that the RELAP5 prediction is now able to capture the major trends of the observed flow commonly observed during two-phase conditions. However, the onset of oscillations is once again predicted early by the model, possibly caused by the underprediction of heat loss from the heater and cavity. This is likely due to the omission of support structures in the cavity that can act as additional pathways for heat to escape to the environment. To overcome the underprediction of heat loss, part of the insulation surrounding the cavity side panels and the back of the heaters are removed to allow heat to escape directly to the environment, which then improves the RELAP5 prediction. Parametric studies are also performed to investigate the effects of heater power, tank inventory level, and tank gas space pressure on flow behaviors, also in direct comparison to conditions tested experimentally. User option-61 in the RELAP5-3D input deck, which changes the heat transfer coefficient correlations used for calculating the vapor generation, is also investigated where it is found that by enabling the option, the overall duration of oscillations is increased and matches that from the experiment better. The RELAP5 model is further benchmarked with a header inlet- throttling case where it is observed that the prediction from the model fails to capture some major features observed in the experiment. By using a modified loss coefficient curve for the valve, the accuracy of the prediction is improved where most of the major features observed in the experiment are predicted by the model. Lastly, the model is benchmarked with an inventory depletion scenario where it is observed that despite the modeling limitation of RELAP5, the prediction shows good agreement with the experimental data where major trends and features are captured by the model. Future work will see continued development of the current RELAP5-3D input deck of the NSTF to both improve the accuracy of the model’s predictive capability and continuing serving the experimental program. The mutually beneficial relationship between analysis and experimental efforts has become integral to the parent NSTF program, and the greater objective to fully understand and accurately predict the heat removal performance of a full scale RCCS concept.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Optimizing Power Generation of a Bottom-Raised Oscillating Surge Wave Energy Converter Using a Theoretical Model: Preprint

Preliminary sizing of an oscillating surge wave energy converter (OSWEC) is an iterative process that relies on knowledge of the relevant hydrodynamic coefficients for a given geometry. Often, the complex definition of the device geometry requires coefficients to be obtained through experiments or numerical boundary element solvers such as WAMIT. These techniques demand significant user and computational effort, therefore inhibiting the fine scale parametrization of object dimensions. In this study, a theoretical model, originally presented in Michele et al. (2016), is developed and demonstrated to efficiently optimize the power production for an OSWEC device (subjected to certain environmental conditions) with variations in device widths, heights, and distances from the seabed. Assuming negligible device thickness, the OSWEC motions are modelled as a bottom-raised two-dimensional flap in regular waves using potential flow theory formulated in elliptical coordinates. The solutions to this diffraction-radiation problem are obtained using Mathieu functions with appropriate boundary conditions. The resulting potentials are then used to derive frequency-dependent expressions for the added mass and radiation damping coefficients, along with wave excitation magnitude in surge, pitch, and coupled surge-pitch motions. Good agreement in hydrodynamic coefficient curves is shown between the theoretical model and the numerical results obtained from the boundary element-based program WAMIT. The theoretical model is then employed to maximize the time-averaged output power while maintaining or reducing the hinge reaction force, with variations in device dimensions, wave frequency and amplitude.

ACE↗

Optimizing Power Generation of a Bottomraised Oscillating Surge Wave Energy Converter Using a Theoretical Model

Preliminary sizing of an oscillating surge wave energy converter (OSWEC) is an iterative process that relies on knowledge of the relevant hydrodynamic coefficients for a given geometry. Often, the complex definition of the device geometry requires coefficients to be obtained through experiments or numerical boundary element solvers such as WAMIT. These techniques demand significant user and computational effort, therefore inhibiting the fine scale parametrization of object dimensions. In this study, a theoretical model, originally presented in Michele et al. (2016), is developed and demonstrated to efficiently optimize the power production for an OSWEC device (subjected to certain environmental conditions) with variations in device widths, heights, and distances from the seabed. Assuming negligible device thickness, the OSWEC motions are modelled as a bottom-raised two-dimensional flap in regular waves using potential flow theory formulated in elliptical coordinates. The solutions to this diffraction-radiation problem are obtained using Mathieu functions with appropriate boundary conditions. The resulting potentials are then used to derive frequency-dependent expressions for the added mass and radiation damping coefficients, along with wave excitation magnitude in surge, pitch, and coupled surge-pitch motions. Good agreement in hydrodynamic coefficient curves is shown between the theoretical model and the numerical results obtained from the boundary element-based program WAMIT. The theoretical model is then employed to maximize the time-averaged output power while maintaining or reducing the hinge reaction force, with variations in device dimensions, wave frequency and amplitude.

ACE↗

1D Modeling for the Development of a Digital Twin for Hydropower Systems with Applications for a Testing Rig

Modeling and simulation constitute two important parts in constructing a sensible digital twin to mimic the dynamics of hydropower systems. Because of the physical nature of a hydropower system, the basic modeling should cover the water flow systems from the reservoir to the penstock (inlet water pipes), penstock to hydro turbine, and hydro turbine to generator and from the linkage of the hydropower systems to the grid. This report describes initial attempts to model these dynamic components, including the formulation of the linearized state space model for hydro turbine systems using the well-known six-coefficients linearization method and the formulation of the voltage and power dynamical models of a synchronous generator. To validate the accuracy of the proposed model, data collected from Norwegian University of Science and Technology were used to obtain relevant parameters for the model, and the desired simulation results were obtained. Additionally, neural network modeling and learning were also developed and applied to model the generation torque and water flow rate subsystems to demonstrate a potential learning scheme, which can be used in the development of a digital twin.

13 HYDRO ENERGY↗

A whole-core steady-state thermal-hydraulic model for annular fuel type fluoride-salt-cooled reactors

A whole-core, steady-state thermal-hydraulic model is developed for the fluoride-salt-cooled small modular advanced high-temperature reactor (SmAHTR) that employs an annular fuel configuration. This pre-conceptual reactor design by Oak Ridge National Laboratory (ORNL) has the annular fuel and moderator pins arranged in a hexagonal layout. The FLiBe coolant flows from the bottom to the top of the core, parallel to the hexagonal bundle. The fuel and moderator pins in the core are discretized into finite volumes and the 3-D heat conduction equation is solved to obtain the temperature profile. Inter-fuel assembly conduction is also addressed. For this fuel assembly configuration, the coolant flows through two distinct regions – the hexagonal pin bundle and the annulus between the fuel pin and the tie rod. The fluid flow through the hexagonal bundles is modeled using the subchannel approach, in which the coolant region is discretized into corner, edge and interior subchannels and the resulting conservation equations are systematically solved. The 1-D mass, momentum and energy equations are solved for the annulus channels between the fuel pin and the tie rod. Pertinent closure models from the literature are employed to close the system of equations. We also performed a preliminary code-to-code comparison between the present model and a CFD model.. The resulting thermal-hydraulic model can provide temperature, flow rate and pressure drop profiles for the different solid and fluid regions throughout the entire core. Whole-core thermal-hydraulic results for a representative power profile are presented and discussed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Control of core–shell nanoparticles properties through plasma synthesis: a computational study

The improved properties of core–shell nanoparticles (CSNPs) over homogeneous nanoparticles (NPs) have expanded and diversified the applications of these nanomaterials. However, controlling the properties of CSNPs can be a challenging task. Low temperature plasmas have proven to be an effective method of producing NPs with uniform size and morphology, and high yield. That said, NP transport and growth dynamics are sensitive to LTP properties. We report on a computational investigation of the evolution of Ge–Si CSNP properties as a function of operating conditions through the modeling of a flowing, two-zone inductively coupled plasma (ICP) reactor. Ar/GeH 4 and Ar/SiH 4 gas mixtures were supplied to separate plasma zones at a pressure of 1 Torr to promote growth of Ge cores and Si shells. The negatively charged CSNPs are trapped electrostatically in the vicinity of the antennas where the plasma is generated and where the majority of particle growth occurs. Particles that grow to a critical size are then de-trapped by fluid drag due to neutral gas flow. A two-dimensional hybrid plasma model coupled with a three-dimensional kinetic NP transport model were utilized to resolve plasma chemistry and NP growth processes that take place on distinct timescales. The trends in CSNP properties and trapping mechanisms associated with flow rate, applied ICP power and inlet precursor fraction are discussed. While the spatial distribution of plasma produced radical species can have significant impact on the NP growth process, the NP transport dynamics are what ultimately dictates the growth environment that is unique to each particle and so determines their final dimension and composition. The key to optimizing reactor conditions involves controlling the spatial density of growth species and plasma profile as a means to tailor particle trapping dynamics suitable to produce CSNPs for a specific application.