Performance characteristics of a 14.3-kilovolt-ampere modified Lundell alternator for 1200 hertz Brayton-cycle space-power system
Performance characteristics of 14.3 kVA modified Lundell alternator for 1200 Hz Brayton cycle space power system
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Performance characteristics of 14.3 kVA modified Lundell alternator for 1200 Hz Brayton cycle space power system
A conventional Volkswagen transporter, a Renault 5, a Pacer, and a U. S. Postal Service general DJ-5 delivery van were treated to an electric vehicle test procedure in order to allow direct comparison of conventional and electric vehicles. Performance test results for the four vehicles are presented.
A module integrated converter (MIC) for a photovoltaic (PV) cell is important part of power conditioning system (PCS). It performs maximum power point tracking of a PV cell to generate the power as much as possible from solar energy. There are several methods for connection between the PV modules and the MICs. In order to avoid partial shading effects, converter-per-module approach was proposed. The MIC that performs maximum power point tracking (MPPT), if it is low efficiency, is no use. The MIC whose output is connected to the output of PV module was proposed for high efficiency. However, there are some problems. In this study, an asymmetrical half-bridge flyback converter is proposed instead of the original flyback converter with same method to solve the problems. The proposed MIC was built to verify the performance. The new topology using soft switching technique showed good performance for the efficiency. At the higher power, the efficiency of the proposed converter is higher than existing converter. (author)
Electrical performance and defect characterization of vertical GaN P-i-N diodes before and after irradiation with 2.5 MeV protons and neutrons is investigated. Devices exhibit increase in specific on-resistance following irradiation with protons and neutrons, indicating displacement damage introduces defects into the p-GaN and n- drift regions of the device that impact on-state device performance. The breakdown voltage of these devices, initially above 1700 V, is observed to decrease only slightly for particle fluence <; 10 13 cm -2 . Furthermore, the unipolar figure of merit for power devices indicates that while the on-resistance and breakdown voltage degrade with irradiation, vertical GaN P-i-Ns remain superior to the performance of the best available, unirradiated silicon devices and on-par with unirradiated modern SiC-based power devices.
The Safe & Precise Landing Integrated Capabilities Evolution (SPLICE) program continues to push the development of advanced descent and landing technologies. This paper will focus on the improvements made to the SPLICE Dual Quaternion Guidance (DQG) algorithm, which is a critical software component for generating approach phase and hazard avoidance trajectories. The trajectory performance of SPLICE DQG will be evaluated in preparation for a terrestrial flight test that incorporates a hazard avoidance maneuver. Additionally, the implementation of a customized first order Proportional-Integral Projected Gradient solver will be reviewed, along with preliminary execution results on the SPLICE Descent and Landing Computer (DLC).
As the capacity of high performance computing (HPC) systems continues to grow, small changes in energy management have the potential to produce significant energy savings. In this paper, we employ an extensive informatics system for aggregating and analyzing real-time performance and power use data to evaluate energy footprints of jobs running in an HPC data center. We look at the effects of algorithmic choices for a given job on the resulting energy footprints, and analyze application-specific power consumption, and summarize average power use in the aggregate. All of these views reveal meaningful power variance between classes of applications as well as chosen methods for a given job. Using these data, we discuss energy-aware cost-saving strategies based on reordering the HPC job schedule. Using historical job and power data, we present a hypothetical job schedule reordering that: (1) reduces the facility's peak power draw and (2) manages power in conjunction with a large-scale photovoltaic array. Lastly, we leverage this data to understand the practical limits on predicting key power use metrics at the time of submission.
An evaluation of simplifications for the thruster power processor interface for a 30 cm Hg ion thruster is presented. Tests on the engine, thruster control, and the power supplies are performed. Reduced power processors requirements are defined and the impact on thruster design, performance, and lifetime are assessed.
The purpose of these Guidelines is to provide direction for conducting performance acceptance testing for large power tower solar systems that can yield results of a high level of accuracy consistent with good engineering knowledge and practice. The recommendations have been developed under a National Renewable Energy Laboratory (NREL) subcontract and reviewed by stakeholders representing concerned organizations and interests throughout the concentrating solar power (CSP) community. An earlier NREL report provided similar guidelines for parabolic trough systems. These Guidelines recommend certain methods, instrumentation, equipment operating requirements, and calculation methods. When tests are run in accordance with these Guidelines, we expect that the test results will yield a valid indication of the actual performance of the tested equipment. But these are only recommendations--to be carefully considered by the contractual parties involved in the Acceptance Tests--and we expect that modifications may be required to fit the particular characteristics of a specific project.
This paper evaluates a state-space methodology of a multi-input multi-output (MIMO) control strategy using a 2 × 2 tightly coupled scenario applied to a physical gas turbine fuel cell hybrid power system. A centralized MIMO controller was preferred compared to a decentralized control approach because previous simulation studies showed that the coupling effect identified during the simultaneous control of the turbine speed and cathode airflow was better minimized. The MIMO controller was developed using a state-space dynamic model of the system that was derived using first-order transfer functions empirically obtained through experimental tests. The controller performance was evaluated in terms of disturbance rejection through perturbations in the gas turbine operation, and setpoint tracking maneuver through turbine speed and cathode airflow steps. The experimental results illustrate that a multicoordination control strategy was able to mitigate the coupling of each actuator to each output during the simultaneous control of the system, and improved the overall system performance during transient conditions. On the other hand, the controller showed different performance during validation in simulation environment compared to validation in the physical facility, which will require a better dynamic modeling of the system for the implementation of future multivariable control strategies.
In this paper, two second-generation high power density DC/DC converter modules have been evaluated at low operating temperatures. The power rating of one converter (Module 1) was specified at 150 W with an input voltage range of 36 to 75 V and output voltage of 12 V. The other converter (Module 2) was specified at 100 W with the same input voltage range and an output voltage of 3.3 V. The converter modules were evaluated in terms of their performance as a function of operating temperature in the range of 25 to -140 C. The experimental procedures along with the experimental data obtained are presented and discussed in this paper.
A performance analysis has been made to determine whether boundary-layer control by suction might reduce the minimum take-off and landing distances of a four-place or five-place airplane or a liaison type of airplane below those obtainable with conventional high-lift devices. The airplane was assumed to have a cruise duration of 5 hours at 60-percent power and to be operating from airstrips having a ground friction coefficient of 0.2 or a combined ground and braking coefficient of 0.4. The payload was fixed at 1500 pounds, the wing span was varied from 25 to 100 feet, the aspect ratio was varied from 5 to 15, and the power was varied from 300 to 1300 horsepower. Maximum lift coefficients of 5.0 and 2.8 were assumed for the airplanes with and without boundary-layer-control --equipment weight was included. The effects of the boundary-layer control on total take-off distance, total power-off landing distance, landing and take-off ground run, stalling speed, sinking speed, and gliding speed were determined.
Abstract not provided.
High temperature concentrating solar power plants require suitable thermal energy storage systems to produce electric power efficiently. Thermochemical energy storage based on metal hydrides represents a very appealing prospect for low cost and high efficient solar storage systems. The objective of the paper is to assess the properties required by the metal hydride systems to achieve the U.S. Department of Energy’s SunShot techno-economic targets. A simplified model has been developed to evaluate the cost and the exergetic efficiency of hydridebased storage systems. Results demonstrate that metal hydride materials, operating at temperatures higher than 650 °C, with reaction enthalpy on the order of 95-110 kJ/molH 2 , raw material cost on the order of 1.4-2 $/kg, weight capacities on the order of 3-4% and operating pressures on the order of tens of bars have the potential to closely approach the targets. Selected sensitivity analyses have also been carried out showing that the raw material cost, the material weight capacity and the metal hydride reaction enthalpy are the properties that strongly affect the performance of the storage system.
The performance of a jet power plant consisting of a compressor and a turbine is determined by the characteristic curves of these component parts and is controllable by the characteristics of the compressor and the turbine i n relation t o each other. The normal. output, overload, and throttled load of the Jet power plant are obtained on the basis of assumed straight-line characteristics.
Reconfigurable architectures like Field Programmable Gate Arrays (FPGAs) have been used for accelerating computations from several domains because of their unique combination of flexibility, performance, and power efficiency. However, FPGAs have not been widely used for high-performance computing, primarily because of their programming complexity and difficulties in optimizing performance. In this paper, we present a directive-based, high-level optimization framework for high-performance computing with FPGAs, built on top of an OpenACC-to-FPGA translation framework called OpenARC. We propose directive extensions and correspond- ing compile-time optimization techniques to enable the compiler to generate more efficient FPGA hardware configuration files. Empirical evaluation of the proposed framework on an Intel Stratix V with five OpenACC benchmarks from various application domains shows that FPGA-specific optimizations can lead to significant increases in performance across all tested applications. We also demonstrate that applying these high-level directive-based optimizations can allow OpenACC applications to perform similarly to lower-level OpenCL applications with hand-written FPGA-specific optimizations, and offer runtime and power performance benefits compared to CPUs and GPUs.
The need for simple, but accurate performance models of wind turbine generators (WTGs), photovoltaic (PV) plants, and battery energy storage systems (BESS) for various hybrid power plant (HPP) studies motivates the present work. Particularly, the development and verification stage of HPP controls requires reduced-order models to minimize the complexity and computation effort of simulation platforms. In this paper, such models are proposed, and the most essential parts of the models are validated through field measurements. The models target power system integration studies involving active and reactive power, as well as frequency and voltage regulation where detailed models, as proposed in the standards, can be cumbersome. Field measurements of two Vestas WTGs, one 1-MW PV plant, and one 1-MW/1-MWh BESS are used for model validation. The results show that the WTG and PV performance models correctly estimate the power generation variability according to fluctuations in wind speed and solar irradiance. The BESS performance model provides satisfactory results related to grid-forming control performance and estimation of state-of-charge. The presented validation work enables using the proposed performance models for power system studies and HPP control design in all model-based design stages, that is, preliminary analysis, design, verification, and validation with a high level of confidence.
Performance and operating characteristics are presented for a solar powered aircraft intended to remain aloft for long periods. The critical technologies which limit the performance are identified. By using the techniques presented, the effects of variation in the system parameters are studied. Practical design consideration are discussed.
Despite advances in the programmable logic capabilities of modern trigger systems, a significant bottleneck remains in the amount of data to be transported from the detector to off-detector logic where trigger decisions are made. We demonstrate that a neural network (NN) autoencoder model can be implemented in a radiation-tolerant application-specific integrated circuit (ASIC) to perform lossy data compression alleviating the data transmission problem while preserving critical information of the detector energy profile. For our application, we consider the high-granularity calorimeter from the Compact Muon Solenoid (CMS) experiment at the CERN Large Hadron Collider. The advantage of the machine learning approach is in the flexibility and configurability of the algorithm. By changing the NN weights, a unique data compression algorithm can be deployed for each sensor in different detector regions and changing detector or collider conditions. To meet area, performance, and power constraints, we perform quantization-aware training to create an optimized NN hardware implementation. The design is achieved through the use of high-level synthesis tools and the hls4ml framework and was processed through synthesis and physical layout flows based on a low-power (LP)-CMOS 65-nm technology node. The flow anticipates 200 Mrad of ionizing radiation to select gates and reports a total area of 3.6 mm 2 and consumes 95 mW of power. The simulated energy consumption per inference is 2.4 nJ. Furthermore, this is the first radiation-tolerant on-detector ASIC implementation of an NN that has been designed for particle physics applications.